Hanna HI83749-02 Turbidity and Bentonite Check Meter
  • Free Shipping

    Orders above Rs. 1000.

  • On Time Delivery

    Within 7 days.

  • Money Back Guarantee

    14 day Return*

  • Service Support

    Online Installation Support.

Product Description

The Hanna HI83749-02 is a portable turbidity meter for monitoring protein stability and bentonite in wine. It is supplied with Bentocheck reagent and uses a ratio nephelometric method with 90° scattered-light and 180° transmitted-light detectors.

Key features

  • 2-, 3- or 4-point calibration (<0.1, 10, 100, 500 NTU)
  • Fast Tracker tag identification system for time and location
  • GLP data; internal logging of up to 200 records
  • USB or RS232 transfer with HI92000 software
  • Backlit LCD; battery or line operation
  • Colour interference correction and lamp-intensity compensation

Technical specifications

Model HI83749-02
Range 0.00 to 9.99; 10.0 to 99.9; 100 to 1200 NTU
Resolution 0.01; 0.1; 1 NTU
Accuracy ±2 % of reading + 0.05 NTU
Repeatability ±1 % of reading or 0.02 NTU, whichever is greater
Stray light <0.05 NTU
Method Ratio nephelometric
Light source / detector Tungsten filament lamp / silicon photocell
Auto-off After 15 minutes of non-use
Memory / connectivity 200 records / USB or RS232
Power 4 x 1.5 V AA alkaline; AC/DC adapter (rating to confirm)
Environment 0 to 50 °C; max RH 95 % non-condensing
Dimensions / weight 224 x 87 x 77 mm / 512 g

Supplied in the box

  • Six sample cuvettes with caps; four HI83749-11 calibration cuvettes
  • Bentocheck reagent HI83749-20 and silicone oil HI93703-58
  • 1000 µL automatic pipette with two tips; 1 mL syringe with two tips
  • Four 25 mL glass vials with caps; funnel and 25 filter papers
  • Cuvette cleaning cloth, AC adapter and batteries
  • Five tag holders with tags
  • Instruction manual, quality certificate, rugged carrying case

Frequently asked questions

What is it used for?

Monitoring protein stability and bentonite in wine.

What is the range?

0.00 to 1200 NTU.

What is the accuracy?

±2 % of reading + 0.05 NTU.

Which calibration standards are supplied?

AMCO AEPA-1 standards up to 500 NTU; the range extends to 1200 NTU.

Can it store data?

Yes, up to 200 records, with USB or RS232 transfer.

Is Bentocheck reagent included?

Yes, HI83749-20.

What power does it use?

Four AA alkaline batteries or an AC/DC adapter; Hanna lists 110 VAC, so confirm for India.

Which model code is correct?

Hanna's title says HI83749-02 while its spec table says HI83749-01 - to confirm.

What is the delivery lead time?

Hanna's page shows a pre-order, ships in 5 to 6 weeks - confirm with us before ordering.

Will I get a GST invoice, and can I get a bulk or institutional quotation?

Yes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.