The LABMAN BOD4000 BOD Analyzer measures biochemical oxygen demand (BOD), an environmental pollution index used to judge organic pollution in water and to evaluate the efficiency of sewage treatment plants and ETPs. It uses pressure measurement (differential pressure, manometric) in a closed system and reads BOD directly in mg/L, with up to six samples per run.
Key features
- Free onsite installation
- Measuring principle: differential pressure (manometric)
- BOD value can be read at any time during or after the 5-day incubation
- BOD ranges up to 4000 mg/L using different sample volumes
- Six measurements at once with 580 ml culture bottles
- Measurement period 1–30 days; working temperature 20 ± 1°C
- Stores 10-year BOD5 result values; backlit display with date and time
Technical specifications
| Parameter | Specification |
|---|---|
| Model | BOD4000 |
| Make | LABMAN |
| Parameter | BOD |
| BOD range | 0–4000 mg/L |
| Accuracy | Qualified for BOD5 (glucose-glutamic acid standard solution BOD5 = 180–230 mg/L) |
| Measurement days | 1–30 days |
| Number of sample measurements | 6 |
| Volume of container | 580 ml |
| Working temperature | 20 ± 1°C |
| Data management / storage | 10-year BOD5 result value |
| Display backlight | Yes |
| Date and time | Yes |
| General | Power AC adapter, 100–240 V AC input |
| Machine dimension (L×W×H) | 272 × 185 × 75 mm |
| Packing dimension (L×W×H) | 495 × 420 × 225 mm |
| Power supply | Adaptor, using AC 220 V, 50/60 Hz |
| Gross weight | 8 kg |
Supplied with
Main instrument, BOD test terminal, 6 BOD culture bottles (580 ml), stirrer, chemical cup, culture bottle holder, instruction manual, test certificate.
Frequently asked questions
How does the BOD4000 measure BOD?
By pressure measurement in a closed system: micro-organisms consume oxygen and release CO2, which is absorbed, creating a vacuum that the BOD sensor reads directly in mg/L.
How many samples can it test at once?
Six, using six 580 ml BOD culture bottles.
What is the measuring range and how do I choose sample volume?
0–4000 mg/L. The catalogue gives a sample volume table, for example 500 ml for 0–20 mg/L, 400 ml for 0–80 mg/L and 25 ml for 0–4000 mg/L.
How long is the test?
The standard test is 5 days; measurement days can be set from 1 to 30 days.
What temperature is required?
The working temperature is 20 ± 1°C.
What power supply does it need?
Adaptor, using AC 220 V, 50/60 Hz.
What is supplied with it?
Main instrument, BOD test terminal, 6 BOD culture bottles (580 ml), stirrer, chemical cup, culture bottle holder, instruction manual, test certificate.
What are the packing size and weight?
495 × 420 × 225 mm (L×W×H as per catalogue), gross weight 8 kg.
Can I get a GST invoice and a bulk or institutional quotation?
Yes. Labmart (Chemlab Equipment) supplies against a GST invoice and provides quotations for colleges, hospitals, pharma companies and government labs, including bulk and tender requirements. Contact us with your requirement for a formal quotation.
What is the warranty and delivery time?
LABMAN instruments supplied by Labmart carry a standard 13-month warranty. Delivery time depends on your location and stock, so please contact Labmart for a delivery estimate.
- Regular price
- Rs.200,000.00
- Sale price
- Rs.159,999.00
Sale
The LABMAN BOD4000 BOD Analyzer measures biochemical oxygen demand (BOD), an environmental pollution index used to judge organic pollution in water and to evaluate the efficiency of sewage treatment plants and ETPs. It uses pressure measurement (differential pressure, manometric) in a closed system and reads BOD directly in mg/L, with up to six samples per run.
Key features
- Free onsite installation
- Measuring principle: differential pressure (manometric)
- BOD value can be read at any time during or after the 5-day incubation
- BOD ranges up to 4000 mg/L using different sample volumes
- Six measurements at once with 580 ml culture bottles
- Measurement period 1–30 days; working temperature 20 ± 1°C
- Stores 10-year BOD5 result values; backlit display with date and time
Technical specifications
| Parameter | Specification |
|---|---|
| Model | BOD4000 |
| Make | LABMAN |
| Parameter | BOD |
| BOD range | 0–4000 mg/L |
| Accuracy | Qualified for BOD5 (glucose-glutamic acid standard solution BOD5 = 180–230 mg/L) |
| Measurement days | 1–30 days |
| Number of sample measurements | 6 |
| Volume of container | 580 ml |
| Working temperature | 20 ± 1°C |
| Data management / storage | 10-year BOD5 result value |
| Display backlight | Yes |
| Date and time | Yes |
| General | Power AC adapter, 100–240 V AC input |
| Machine dimension (L×W×H) | 272 × 185 × 75 mm |
| Packing dimension (L×W×H) | 495 × 420 × 225 mm |
| Power supply | Adaptor, using AC 220 V, 50/60 Hz |
| Gross weight | 8 kg |
Supplied with
Main instrument, BOD test terminal, 6 BOD culture bottles (580 ml), stirrer, chemical cup, culture bottle holder, instruction manual, test certificate.
Frequently asked questions
How does the BOD4000 measure BOD?
By pressure measurement in a closed system: micro-organisms consume oxygen and release CO2, which is absorbed, creating a vacuum that the BOD sensor reads directly in mg/L.
How many samples can it test at once?
Six, using six 580 ml BOD culture bottles.
What is the measuring range and how do I choose sample volume?
0–4000 mg/L. The catalogue gives a sample volume table, for example 500 ml for 0–20 mg/L, 400 ml for 0–80 mg/L and 25 ml for 0–4000 mg/L.
How long is the test?
The standard test is 5 days; measurement days can be set from 1 to 30 days.
What temperature is required?
The working temperature is 20 ± 1°C.
What power supply does it need?
Adaptor, using AC 220 V, 50/60 Hz.
What is supplied with it?
Main instrument, BOD test terminal, 6 BOD culture bottles (580 ml), stirrer, chemical cup, culture bottle holder, instruction manual, test certificate.
What are the packing size and weight?
495 × 420 × 225 mm (L×W×H as per catalogue), gross weight 8 kg.
Can I get a GST invoice and a bulk or institutional quotation?
Yes. Labmart (Chemlab Equipment) supplies against a GST invoice and provides quotations for colleges, hospitals, pharma companies and government labs, including bulk and tender requirements. Contact us with your requirement for a formal quotation.
What is the warranty and delivery time?
LABMAN instruments supplied by Labmart carry a standard 13-month warranty. Delivery time depends on your location and stock, so please contact Labmart for a delivery estimate.
- Regular price
- Rs.200,000.00
- Sale price
- Rs.159,999.00
Sale
GST Invoice included
(Save 18% on business purchases)
Need Quote ?
Get Bulk Order Quotation for your lab or Tender Quotation at special discounts !
Contact our support team at support@labmart.in to get the best quote for your bulk order requirement.
Sales Support - +918920746300
Technical Support- +919667893959
Kindly allow us a time of 2-3 days to properly match all the inquired specs, we will also provide authorization(s) to dealers for particular tenders (on tender basis)

-
Free Shipping
Orders above Rs. 1000.
-
On Time Delivery
Within 7 days.
-
Money Back Guarantee
14 day Return*
-
Service Support
Online Installation Support.
Product Description
The LABMAN BOD4000 BOD Analyzer measures biochemical oxygen demand (BOD), an environmental pollution index used to judge organic pollution in water and to evaluate the efficiency of sewage treatment plants and ETPs. It uses pressure measurement (differential pressure, manometric) in a closed system and reads BOD directly in mg/L, with up to six samples per run.
Key features
- Free onsite installation
- Measuring principle: differential pressure (manometric)
- BOD value can be read at any time during or after the 5-day incubation
- BOD ranges up to 4000 mg/L using different sample volumes
- Six measurements at once with 580 ml culture bottles
- Measurement period 1–30 days; working temperature 20 ± 1°C
- Stores 10-year BOD5 result values; backlit display with date and time
Technical specifications
| Parameter | Specification |
|---|---|
| Model | BOD4000 |
| Make | LABMAN |
| Parameter | BOD |
| BOD range | 0–4000 mg/L |
| Accuracy | Qualified for BOD5 (glucose-glutamic acid standard solution BOD5 = 180–230 mg/L) |
| Measurement days | 1–30 days |
| Number of sample measurements | 6 |
| Volume of container | 580 ml |
| Working temperature | 20 ± 1°C |
| Data management / storage | 10-year BOD5 result value |
| Display backlight | Yes |
| Date and time | Yes |
| General | Power AC adapter, 100–240 V AC input |
| Machine dimension (L×W×H) | 272 × 185 × 75 mm |
| Packing dimension (L×W×H) | 495 × 420 × 225 mm |
| Power supply | Adaptor, using AC 220 V, 50/60 Hz |
| Gross weight | 8 kg |
Supplied with
Main instrument, BOD test terminal, 6 BOD culture bottles (580 ml), stirrer, chemical cup, culture bottle holder, instruction manual, test certificate.
Frequently asked questions
How does the BOD4000 measure BOD?
By pressure measurement in a closed system: micro-organisms consume oxygen and release CO2, which is absorbed, creating a vacuum that the BOD sensor reads directly in mg/L.
How many samples can it test at once?
Six, using six 580 ml BOD culture bottles.
What is the measuring range and how do I choose sample volume?
0–4000 mg/L. The catalogue gives a sample volume table, for example 500 ml for 0–20 mg/L, 400 ml for 0–80 mg/L and 25 ml for 0–4000 mg/L.
How long is the test?
The standard test is 5 days; measurement days can be set from 1 to 30 days.
What temperature is required?
The working temperature is 20 ± 1°C.
What power supply does it need?
Adaptor, using AC 220 V, 50/60 Hz.
What is supplied with it?
Main instrument, BOD test terminal, 6 BOD culture bottles (580 ml), stirrer, chemical cup, culture bottle holder, instruction manual, test certificate.
What are the packing size and weight?
495 × 420 × 225 mm (L×W×H as per catalogue), gross weight 8 kg.
Can I get a GST invoice and a bulk or institutional quotation?
Yes. Labmart (Chemlab Equipment) supplies against a GST invoice and provides quotations for colleges, hospitals, pharma companies and government labs, including bulk and tender requirements. Contact us with your requirement for a formal quotation.
What is the warranty and delivery time?
LABMAN instruments supplied by Labmart carry a standard 13-month warranty. Delivery time depends on your location and stock, so please contact Labmart for a delivery estimate.
Similar Products
-
Sale
Vendor: Labman
COD2000 COD Analyzer with Digestor – 420 & 620 nm, 0–1500 mg/L, 4.5" Touch Screen Digestor, 2000 Data Sets, Free Onsite Installation
No reviewsSale price Rs.202,999.00Regular price Rs.303,999.00 -
Sale
Vendor: Systonic
Chemical Oxygen Demand (COD) Digester Apparatus-S-9315
Sale price Rs.52,000.00Regular price Rs.78,000.00 -
Sale
Vendor: Systonic
COD Digesters-S-9306
Sale price Rs.34,000.00Regular price Rs.54,000.00 -
Sale
Vendor: Systonic
Systonic COD Digester S-9312
Sale price Rs.44,000.00Regular price Rs.74,000.00