This COD analyzer measures chemical oxygen demand (COD) by the potassium dichromate method and is supplied with a COD digestor/reactor. Two LED wavelengths cover low-range and high-range determinations, and an in-built thermal printer and 2000-set memory support wastewater, effluent and environmental testing.
Key Features
- COD analyzer supplied together with COD digestor / reactor
- 5.7" LCD photometer and 4.5" touch-screen digestor
- 420 nm and 620 nm LED light source for LR and HR CODCr
- Data capacity of up to 2000 sets (GLP-compliant) with user ID, date/time and sample ID
- In-built thermal printer; data export option available
- Customized printing data; sample cell type can be modified
- Heating indication light (green/orange), heating and timing alarm
- Pre-defined CODCr program (150 °C, 120 min)
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | COD analyzer with digestor / reactor |
| Method | LR CODCr and HR CODCr, potassium dichromate method |
| LR CODCr range | 0 to 150 mg/L (420 nm) |
| HR CODCr range | 150 to 1500 mg/L (620 nm) |
| Accuracy | ± 8 % |
| Repeatability | ≤ 3 % |
| Fluctuation | < 6 mg/L (20 min) |
| Wavelengths | 420 nm and 620 nm LED, accuracy ± 4 nm |
| Sample cells | 16 mm round cell holder |
| Photometer display | 5.7" LCD |
| Data storage | Up to 2000 sets with user ID, date/time, sample ID |
| Printer | In-built thermal printer |
| Digestor display | 4.5" touch screen |
| Digestor holes | 8 holes x 16 mm |
| Digestor temperature range | 45 to 165 °C, resolution 1 °C, accuracy ± 2 °C |
| Heating rate | 20 to 165 °C in 10 min |
| Heating mode | Continuous and intermittent |
| Digestor time range | 0 to 120 min |
| Pre-defined program | CODCr (150 °C, 120 min) |
| Digestor power | 250 W |
| Ambient temperature | 10 to 40 °C |
| Power supply | AC 220 V, 50–60 Hz |
| Packing dimensions | 370 x 325 x 220 mm (analyzer and digestor each) |
| Net / gross weight | Analyzer 1.5 / 2 kg; digestor 2 / 3 kg |
Supplied With
- Main instrument (COD analyzer)
- COD digestor / reactor
- COD vials 0–150 mg/L – 25 nos
- COD vials 0–1500 mg/L – 25 nos
- Power cable and adaptor
- Instruction manual
- Test certificate
Delivery Period – 10 days
Frequently Asked Questions
Do you provide a GST invoice and bulk or institutional quotation?
Yes. A GST invoice is provided with every order, and quotations for colleges, hospitals, pharma companies and government labs, including bulk orders, are available on request.
What is the HSN code?
To confirm. Please contact us and we will share the applicable HSN code on your quotation.
What COD ranges can it measure?
Low range 0–150 mg/L at 420 nm and high range 150–1500 mg/L at 620 nm, by the potassium dichromate method.
Is the digestor included?
Yes. The COD digestor / reactor is supplied as standard with the analyzer.
What warranty is provided?
12 months from the date of dispatch against manufacturing defects. Fragile parts and third-party parts are excluded.
What is the delivery time?
Delivery period is 10 days. Freight is charged extra.
What is supplied with the product?
See the Supplied With list above.
What are the power requirements?
AC 220 V, 50 Hz
Is installation support available?
Yes. Online installation and operating guidance is provided.
Can your team help me choose the right model?
Yes. Our technical team can help you compare models and choose the right capacity or class for your application.
- Regular price
- Rs.292,299.00
- Sale price
- Rs.182,699.00
Sale
This COD analyzer measures chemical oxygen demand (COD) by the potassium dichromate method and is supplied with a COD digestor/reactor. Two LED wavelengths cover low-range and high-range determinations, and an in-built thermal printer and 2000-set memory support wastewater, effluent and environmental testing.
Key Features
- COD analyzer supplied together with COD digestor / reactor
- 5.7" LCD photometer and 4.5" touch-screen digestor
- 420 nm and 620 nm LED light source for LR and HR CODCr
- Data capacity of up to 2000 sets (GLP-compliant) with user ID, date/time and sample ID
- In-built thermal printer; data export option available
- Customized printing data; sample cell type can be modified
- Heating indication light (green/orange), heating and timing alarm
- Pre-defined CODCr program (150 °C, 120 min)
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | COD analyzer with digestor / reactor |
| Method | LR CODCr and HR CODCr, potassium dichromate method |
| LR CODCr range | 0 to 150 mg/L (420 nm) |
| HR CODCr range | 150 to 1500 mg/L (620 nm) |
| Accuracy | ± 8 % |
| Repeatability | ≤ 3 % |
| Fluctuation | < 6 mg/L (20 min) |
| Wavelengths | 420 nm and 620 nm LED, accuracy ± 4 nm |
| Sample cells | 16 mm round cell holder |
| Photometer display | 5.7" LCD |
| Data storage | Up to 2000 sets with user ID, date/time, sample ID |
| Printer | In-built thermal printer |
| Digestor display | 4.5" touch screen |
| Digestor holes | 8 holes x 16 mm |
| Digestor temperature range | 45 to 165 °C, resolution 1 °C, accuracy ± 2 °C |
| Heating rate | 20 to 165 °C in 10 min |
| Heating mode | Continuous and intermittent |
| Digestor time range | 0 to 120 min |
| Pre-defined program | CODCr (150 °C, 120 min) |
| Digestor power | 250 W |
| Ambient temperature | 10 to 40 °C |
| Power supply | AC 220 V, 50–60 Hz |
| Packing dimensions | 370 x 325 x 220 mm (analyzer and digestor each) |
| Net / gross weight | Analyzer 1.5 / 2 kg; digestor 2 / 3 kg |
Supplied With
- Main instrument (COD analyzer)
- COD digestor / reactor
- COD vials 0–150 mg/L – 25 nos
- COD vials 0–1500 mg/L – 25 nos
- Power cable and adaptor
- Instruction manual
- Test certificate
Delivery Period – 10 days
Frequently Asked Questions
Do you provide a GST invoice and bulk or institutional quotation?
Yes. A GST invoice is provided with every order, and quotations for colleges, hospitals, pharma companies and government labs, including bulk orders, are available on request.
What is the HSN code?
To confirm. Please contact us and we will share the applicable HSN code on your quotation.
What COD ranges can it measure?
Low range 0–150 mg/L at 420 nm and high range 150–1500 mg/L at 620 nm, by the potassium dichromate method.
Is the digestor included?
Yes. The COD digestor / reactor is supplied as standard with the analyzer.
What warranty is provided?
12 months from the date of dispatch against manufacturing defects. Fragile parts and third-party parts are excluded.
What is the delivery time?
Delivery period is 10 days. Freight is charged extra.
What is supplied with the product?
See the Supplied With list above.
What are the power requirements?
AC 220 V, 50 Hz
Is installation support available?
Yes. Online installation and operating guidance is provided.
Can your team help me choose the right model?
Yes. Our technical team can help you compare models and choose the right capacity or class for your application.
- Regular price
- Rs.292,299.00
- Sale price
- Rs.182,699.00
Sale
GST Invoice included
(Save 18% on business purchases)
Need Quote ?
Get Bulk Order Quotation for your lab or Tender Quotation at special discounts !
Contact our support team at support@labmart.in to get the best quote for your bulk order requirement.
Sales Support - +918920746300
Technical Support- +919667893959
Kindly allow us a time of 2-3 days to properly match all the inquired specs, we will also provide authorization(s) to dealers for particular tenders (on tender basis)

-
Free Shipping
Orders above Rs. 1000.
-
On Time Delivery
Within 7 days.
-
Money Back Guarantee
14 day Return*
-
Service Support
Online Installation Support.
Product Description
This COD analyzer measures chemical oxygen demand (COD) by the potassium dichromate method and is supplied with a COD digestor/reactor. Two LED wavelengths cover low-range and high-range determinations, and an in-built thermal printer and 2000-set memory support wastewater, effluent and environmental testing.
Key Features
- COD analyzer supplied together with COD digestor / reactor
- 5.7" LCD photometer and 4.5" touch-screen digestor
- 420 nm and 620 nm LED light source for LR and HR CODCr
- Data capacity of up to 2000 sets (GLP-compliant) with user ID, date/time and sample ID
- In-built thermal printer; data export option available
- Customized printing data; sample cell type can be modified
- Heating indication light (green/orange), heating and timing alarm
- Pre-defined CODCr program (150 °C, 120 min)
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | COD analyzer with digestor / reactor |
| Method | LR CODCr and HR CODCr, potassium dichromate method |
| LR CODCr range | 0 to 150 mg/L (420 nm) |
| HR CODCr range | 150 to 1500 mg/L (620 nm) |
| Accuracy | ± 8 % |
| Repeatability | ≤ 3 % |
| Fluctuation | < 6 mg/L (20 min) |
| Wavelengths | 420 nm and 620 nm LED, accuracy ± 4 nm |
| Sample cells | 16 mm round cell holder |
| Photometer display | 5.7" LCD |
| Data storage | Up to 2000 sets with user ID, date/time, sample ID |
| Printer | In-built thermal printer |
| Digestor display | 4.5" touch screen |
| Digestor holes | 8 holes x 16 mm |
| Digestor temperature range | 45 to 165 °C, resolution 1 °C, accuracy ± 2 °C |
| Heating rate | 20 to 165 °C in 10 min |
| Heating mode | Continuous and intermittent |
| Digestor time range | 0 to 120 min |
| Pre-defined program | CODCr (150 °C, 120 min) |
| Digestor power | 250 W |
| Ambient temperature | 10 to 40 °C |
| Power supply | AC 220 V, 50–60 Hz |
| Packing dimensions | 370 x 325 x 220 mm (analyzer and digestor each) |
| Net / gross weight | Analyzer 1.5 / 2 kg; digestor 2 / 3 kg |
Supplied With
- Main instrument (COD analyzer)
- COD digestor / reactor
- COD vials 0–150 mg/L – 25 nos
- COD vials 0–1500 mg/L – 25 nos
- Power cable and adaptor
- Instruction manual
- Test certificate
Delivery Period – 10 days
Frequently Asked Questions
Do you provide a GST invoice and bulk or institutional quotation?
Yes. A GST invoice is provided with every order, and quotations for colleges, hospitals, pharma companies and government labs, including bulk orders, are available on request.
What is the HSN code?
To confirm. Please contact us and we will share the applicable HSN code on your quotation.
What COD ranges can it measure?
Low range 0–150 mg/L at 420 nm and high range 150–1500 mg/L at 620 nm, by the potassium dichromate method.
Is the digestor included?
Yes. The COD digestor / reactor is supplied as standard with the analyzer.
What warranty is provided?
12 months from the date of dispatch against manufacturing defects. Fragile parts and third-party parts are excluded.
What is the delivery time?
Delivery period is 10 days. Freight is charged extra.
What is supplied with the product?
See the Supplied With list above.
What are the power requirements?
AC 220 V, 50 Hz
Is installation support available?
Yes. Online installation and operating guidance is provided.
Can your team help me choose the right model?
Yes. Our technical team can help you compare models and choose the right capacity or class for your application.
Similar Products
-
Sale
Vendor: Labman
COD2000 COD Analyzer with Digestor – 420 & 620 nm, 0–1500 mg/L, 4.5" Touch Screen Digestor, 2000 Data Sets, Free Onsite Installation
No reviewsSale price Rs.202,999.00Regular price Rs.303,999.00 -
Sale
Vendor: Quantis
COD Digestion Apparatus, 15 Cavity, 200°C
No reviewsSale price Rs.54,599.00Regular price Rs.87,399.00 -
Sale
Vendor: Quantis
COD Digestion Apparatus, 6 Cavity, 200°C
No reviewsSale price Rs.36,999.00Regular price Rs.59,199.00 -
Sale
Vendor: Quantis
COD Digestion Apparatus, 12 Cavity, 200°C
No reviewsSale price Rs.45,799.00Regular price Rs.73,299.00