You need to choose options for product.
Sale
-
files/LMCM2P_Clean_White_Background.png
-
files/LMCM2P_Realistic_Laboratory_Environment.png
-
files/LMCM2P_Key_Features.png
The Labmart LMCM2P Portable Conductivity Meter is a compact, battery-operated instrument for measuring conductivity, TDS and temperature. It features a backlit LCD, automatic temperature compensation, 1–3 point conductivity calibration, selectable cell constants and memory for up to 100 data sets. The portable design and carrying case make it suitable for laboratory, field and water-quality testing applications.
Product Overview
The Labmart LMCM2P Portable Conductivity Meter is designed for convenient measurement of electrical conductivity, TDS and temperature across a broad measurement range. The meter automatically ranges across conductivity measurement scales and supports selectable cell constants of K = 0.1, 1 and 10, allowing configuration for different conductivity measurement requirements.
The instrument provides 1 to 3-point conductivity calibration with selectable conductivity standard options and incorporates automatic or manual temperature compensation. Its backlit LCD display provides clear measurement visibility, while the Auto-Read function detects and locks the measurement endpoint.
For data handling, the LMCM2P can store and recall up to 100 data sets and provides a USB interface for data transfer or connection to a power adapter. The supplied carrying case supports convenient transportation for field and on-site testing.
Key Features and Benefits
- Wide conductivity measurement range: Auto-ranging from µS/cm to mS/cm supports different conductivity testing requirements.
- 1–3 point calibration: Provides flexible conductivity calibration using selectable standard solutions.
- Selectable cell constant: K = 0.1, 1 or 10 allows the meter to be configured for different conductivity measurement conditions.
- Automatic temperature compensation: Supports temperature-compensated conductivity readings from 0 to 100°C.
- Auto-Read function: Detects and locks the measurement endpoint for convenient testing.
- Backlit LCD display: White backlight improves readability during laboratory and field measurements.
- 100-data memory: Stores up to 100 data sets for convenient result recall.
- USB interface: Supports data transfer or connection to a power adapter.
- Portable operation: Operates using 3 × 1.5V AA batteries, with 5V DC power-adapter support.
- Automatic power-off: Shuts down after 15 minutes when not in use to conserve battery power.
- Carrying case included: Supplied as standard for transportation and field use.
4. Technical Specifications
| Specification | Details |
|---|---|
| Product Type | Portable Conductivity Meter |
| Model | LMCM2P |
| Brand | Labmart |
| Manufacturer | Not specified for the Labmart customer-facing listing |
| Conductivity Range | 0 to 20.00, 200.0, 2000 µS/cm; 20.00, 200.0 mS/cm, auto range |
| Conductivity Resolution | 0.01, 0.1, 1 |
| Conductivity Accuracy | ±0.5% F.S. |
| Conductivity Calibration | 1 to 3 points |
| Conductivity Buffer Options | 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS |
| TDS Range | 0~10.00, 100.0, 1000 ppm; 10.00, 200.0 ppt |
| TDS Resolution | 0.01, 0.1, 1 |
| TDS Accuracy | ±1% F.S. |
| Temperature Range | 0 to 105°C / 32 to 221°F |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.5°C / ±0.9°F |
| Temperature Compensation | 0 to 100°C / 32 to 212°F, manual or automatic |
| Conductivity Cell | Cell Constant K = 0.1 / 1 / 10 |
| Display | LCD with white backlight |
| Hold Function | Yes |
| Auto-Power OFF | 15 minutes if not in use |
| Memory | Stores up to 100 data sets |
| Interface | USB |
| Connector | 6-pin mini-DIN, 3.5 mm jack socket |
| Power Supply | 3 × 1.5V AA batteries or 5V DC power adapter |
| Packing Dimension (L × W × H) | 350 × 90 × 300 mm |
| Gross Weight | 1 kg |
| HSN | 90275090 |
| Standard Accessories | Main instrument, 1K conductivity electrode, conductivity standard solution (1413 µS/cm), instruction manual, test certificate |
Technical values above are taken from the LMCM2P specification table in the supplied catalogue.
5. Applications
The LMCM2P can be used for conductivity and TDS testing in applications such as:
- Water quality testing
- Laboratory water analysis
- Conductivity monitoring
- TDS measurement
- Process-water testing
- Quality-control laboratories
- Educational laboratory experiments
- Field water testing
- Environmental testing
- General aqueous-solution testing
- Research and development laboratories
- Industrial water-quality checks
6. Suitable For
- Research laboratories
- Quality-control laboratories
- Environmental laboratories
- Water-testing laboratories
- Educational institutions
- Industrial laboratories
- Pharmaceutical and chemical laboratories
- Food and beverage laboratories
- Water-treatment operations
- Field testing personnel
- Researchers and laboratory technicians
7. FAQs
1. What is the Labmart LMCM2P used for?
The LMCM2P is a portable meter designed to measure conductivity, TDS and temperature.
2. What is the conductivity range of the LMCM2P?
The conductivity range is 0 to 20.00, 200.0 and 2000 µS/cm, and 20.00 and 200.0 mS/cm with automatic ranging.
3. Can the LMCM2P measure TDS?
Yes. The LMCM2P provides TDS measurement with ranges from 0~10.00, 100.0 and 1000 ppm to 10.00 and 200.0 ppt.
4. How many calibration points does the LMCM2P support?
The meter supports 1 to 3 point conductivity calibration.
5. Does the meter have automatic temperature compensation?
Yes. Temperature compensation can be operated in manual or automatic mode, over 0 to 100°C.
6. What cell constants are supported?
The LMCM2P supports selectable cell constants of K = 0.1, 1 and 10.
7. How many readings can be stored?
The internal memory stores up to 100 data sets.
8. Does the LMCM2P have a backlit display?
Yes. It uses an LCD with white backlight.
9. What power supply does the meter use?
It operates on 3 × 1.5V AA batteries or a 5V DC power adapter.
10. Is a conductivity electrode included?
Yes. A 1K conductivity electrode is listed among the standard accessories.
11. Is a conductivity calibration solution included?
Yes. The standard supply includes a 1413 µS/cm conductivity standard solution.
12. Does the LMCM2P come with a carrying case?
Yes. The catalogue specifies that the carrying case is standard supply.
- Regular price
- Rs.27,999.00
- Sale price
- Rs.17,999.00
Sale
The Labmart LMCM2P Portable Conductivity Meter is a compact, battery-operated instrument for measuring conductivity, TDS and temperature. It features a backlit LCD, automatic temperature compensation, 1–3 point conductivity calibration, selectable cell constants and memory for up to 100 data sets. The portable design and carrying case make it suitable for laboratory, field and water-quality testing applications.
Product Overview
The Labmart LMCM2P Portable Conductivity Meter is designed for convenient measurement of electrical conductivity, TDS and temperature across a broad measurement range. The meter automatically ranges across conductivity measurement scales and supports selectable cell constants of K = 0.1, 1 and 10, allowing configuration for different conductivity measurement requirements.
The instrument provides 1 to 3-point conductivity calibration with selectable conductivity standard options and incorporates automatic or manual temperature compensation. Its backlit LCD display provides clear measurement visibility, while the Auto-Read function detects and locks the measurement endpoint.
For data handling, the LMCM2P can store and recall up to 100 data sets and provides a USB interface for data transfer or connection to a power adapter. The supplied carrying case supports convenient transportation for field and on-site testing.
Key Features and Benefits
- Wide conductivity measurement range: Auto-ranging from µS/cm to mS/cm supports different conductivity testing requirements.
- 1–3 point calibration: Provides flexible conductivity calibration using selectable standard solutions.
- Selectable cell constant: K = 0.1, 1 or 10 allows the meter to be configured for different conductivity measurement conditions.
- Automatic temperature compensation: Supports temperature-compensated conductivity readings from 0 to 100°C.
- Auto-Read function: Detects and locks the measurement endpoint for convenient testing.
- Backlit LCD display: White backlight improves readability during laboratory and field measurements.
- 100-data memory: Stores up to 100 data sets for convenient result recall.
- USB interface: Supports data transfer or connection to a power adapter.
- Portable operation: Operates using 3 × 1.5V AA batteries, with 5V DC power-adapter support.
- Automatic power-off: Shuts down after 15 minutes when not in use to conserve battery power.
- Carrying case included: Supplied as standard for transportation and field use.
4. Technical Specifications
| Specification | Details |
|---|---|
| Product Type | Portable Conductivity Meter |
| Model | LMCM2P |
| Brand | Labmart |
| Manufacturer | Not specified for the Labmart customer-facing listing |
| Conductivity Range | 0 to 20.00, 200.0, 2000 µS/cm; 20.00, 200.0 mS/cm, auto range |
| Conductivity Resolution | 0.01, 0.1, 1 |
| Conductivity Accuracy | ±0.5% F.S. |
| Conductivity Calibration | 1 to 3 points |
| Conductivity Buffer Options | 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS |
| TDS Range | 0~10.00, 100.0, 1000 ppm; 10.00, 200.0 ppt |
| TDS Resolution | 0.01, 0.1, 1 |
| TDS Accuracy | ±1% F.S. |
| Temperature Range | 0 to 105°C / 32 to 221°F |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.5°C / ±0.9°F |
| Temperature Compensation | 0 to 100°C / 32 to 212°F, manual or automatic |
| Conductivity Cell | Cell Constant K = 0.1 / 1 / 10 |
| Display | LCD with white backlight |
| Hold Function | Yes |
| Auto-Power OFF | 15 minutes if not in use |
| Memory | Stores up to 100 data sets |
| Interface | USB |
| Connector | 6-pin mini-DIN, 3.5 mm jack socket |
| Power Supply | 3 × 1.5V AA batteries or 5V DC power adapter |
| Packing Dimension (L × W × H) | 350 × 90 × 300 mm |
| Gross Weight | 1 kg |
| HSN | 90275090 |
| Standard Accessories | Main instrument, 1K conductivity electrode, conductivity standard solution (1413 µS/cm), instruction manual, test certificate |
Technical values above are taken from the LMCM2P specification table in the supplied catalogue.
5. Applications
The LMCM2P can be used for conductivity and TDS testing in applications such as:
- Water quality testing
- Laboratory water analysis
- Conductivity monitoring
- TDS measurement
- Process-water testing
- Quality-control laboratories
- Educational laboratory experiments
- Field water testing
- Environmental testing
- General aqueous-solution testing
- Research and development laboratories
- Industrial water-quality checks
6. Suitable For
- Research laboratories
- Quality-control laboratories
- Environmental laboratories
- Water-testing laboratories
- Educational institutions
- Industrial laboratories
- Pharmaceutical and chemical laboratories
- Food and beverage laboratories
- Water-treatment operations
- Field testing personnel
- Researchers and laboratory technicians
7. FAQs
1. What is the Labmart LMCM2P used for?
The LMCM2P is a portable meter designed to measure conductivity, TDS and temperature.
2. What is the conductivity range of the LMCM2P?
The conductivity range is 0 to 20.00, 200.0 and 2000 µS/cm, and 20.00 and 200.0 mS/cm with automatic ranging.
3. Can the LMCM2P measure TDS?
Yes. The LMCM2P provides TDS measurement with ranges from 0~10.00, 100.0 and 1000 ppm to 10.00 and 200.0 ppt.
4. How many calibration points does the LMCM2P support?
The meter supports 1 to 3 point conductivity calibration.
5. Does the meter have automatic temperature compensation?
Yes. Temperature compensation can be operated in manual or automatic mode, over 0 to 100°C.
6. What cell constants are supported?
The LMCM2P supports selectable cell constants of K = 0.1, 1 and 10.
7. How many readings can be stored?
The internal memory stores up to 100 data sets.
8. Does the LMCM2P have a backlit display?
Yes. It uses an LCD with white backlight.
9. What power supply does the meter use?
It operates on 3 × 1.5V AA batteries or a 5V DC power adapter.
10. Is a conductivity electrode included?
Yes. A 1K conductivity electrode is listed among the standard accessories.
11. Is a conductivity calibration solution included?
Yes. The standard supply includes a 1413 µS/cm conductivity standard solution.
12. Does the LMCM2P come with a carrying case?
Yes. The catalogue specifies that the carrying case is standard supply.
- Regular price
- Rs.27,999.00
- Sale price
- Rs.17,999.00
Sale
GST Invoice included
(Save 18% on business purchases)
Need Quote ?
Get Bulk Order Quotation for your lab or Tender Quotation at special discounts !
Contact our support team at support@labmart.in to get the best quote for your bulk order requirement.
Sales Support - +918920746300
Technical Support- +919667893959
Kindly allow us a time of 2-3 days to properly match all the inquired specs, we will also provide authorization(s) to dealers for particular tenders (on tender basis)

-
Free Shipping
Orders above Rs. 1000.
-
On Time Delivery
Within 7 days.
-
Money Back Guarantee
14 day Return*
-
Service Support
Online Installation Support.
Product Description
The Labmart LMCM2P Portable Conductivity Meter is a compact, battery-operated instrument for measuring conductivity, TDS and temperature. It features a backlit LCD, automatic temperature compensation, 1–3 point conductivity calibration, selectable cell constants and memory for up to 100 data sets. The portable design and carrying case make it suitable for laboratory, field and water-quality testing applications.
Product Overview
The Labmart LMCM2P Portable Conductivity Meter is designed for convenient measurement of electrical conductivity, TDS and temperature across a broad measurement range. The meter automatically ranges across conductivity measurement scales and supports selectable cell constants of K = 0.1, 1 and 10, allowing configuration for different conductivity measurement requirements.
The instrument provides 1 to 3-point conductivity calibration with selectable conductivity standard options and incorporates automatic or manual temperature compensation. Its backlit LCD display provides clear measurement visibility, while the Auto-Read function detects and locks the measurement endpoint.
For data handling, the LMCM2P can store and recall up to 100 data sets and provides a USB interface for data transfer or connection to a power adapter. The supplied carrying case supports convenient transportation for field and on-site testing.
Key Features and Benefits
- Wide conductivity measurement range: Auto-ranging from µS/cm to mS/cm supports different conductivity testing requirements.
- 1–3 point calibration: Provides flexible conductivity calibration using selectable standard solutions.
- Selectable cell constant: K = 0.1, 1 or 10 allows the meter to be configured for different conductivity measurement conditions.
- Automatic temperature compensation: Supports temperature-compensated conductivity readings from 0 to 100°C.
- Auto-Read function: Detects and locks the measurement endpoint for convenient testing.
- Backlit LCD display: White backlight improves readability during laboratory and field measurements.
- 100-data memory: Stores up to 100 data sets for convenient result recall.
- USB interface: Supports data transfer or connection to a power adapter.
- Portable operation: Operates using 3 × 1.5V AA batteries, with 5V DC power-adapter support.
- Automatic power-off: Shuts down after 15 minutes when not in use to conserve battery power.
- Carrying case included: Supplied as standard for transportation and field use.
4. Technical Specifications
| Specification | Details |
|---|---|
| Product Type | Portable Conductivity Meter |
| Model | LMCM2P |
| Brand | Labmart |
| Manufacturer | Not specified for the Labmart customer-facing listing |
| Conductivity Range | 0 to 20.00, 200.0, 2000 µS/cm; 20.00, 200.0 mS/cm, auto range |
| Conductivity Resolution | 0.01, 0.1, 1 |
| Conductivity Accuracy | ±0.5% F.S. |
| Conductivity Calibration | 1 to 3 points |
| Conductivity Buffer Options | 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS |
| TDS Range | 0~10.00, 100.0, 1000 ppm; 10.00, 200.0 ppt |
| TDS Resolution | 0.01, 0.1, 1 |
| TDS Accuracy | ±1% F.S. |
| Temperature Range | 0 to 105°C / 32 to 221°F |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.5°C / ±0.9°F |
| Temperature Compensation | 0 to 100°C / 32 to 212°F, manual or automatic |
| Conductivity Cell | Cell Constant K = 0.1 / 1 / 10 |
| Display | LCD with white backlight |
| Hold Function | Yes |
| Auto-Power OFF | 15 minutes if not in use |
| Memory | Stores up to 100 data sets |
| Interface | USB |
| Connector | 6-pin mini-DIN, 3.5 mm jack socket |
| Power Supply | 3 × 1.5V AA batteries or 5V DC power adapter |
| Packing Dimension (L × W × H) | 350 × 90 × 300 mm |
| Gross Weight | 1 kg |
| HSN | 90275090 |
| Standard Accessories | Main instrument, 1K conductivity electrode, conductivity standard solution (1413 µS/cm), instruction manual, test certificate |
Technical values above are taken from the LMCM2P specification table in the supplied catalogue.
5. Applications
The LMCM2P can be used for conductivity and TDS testing in applications such as:
- Water quality testing
- Laboratory water analysis
- Conductivity monitoring
- TDS measurement
- Process-water testing
- Quality-control laboratories
- Educational laboratory experiments
- Field water testing
- Environmental testing
- General aqueous-solution testing
- Research and development laboratories
- Industrial water-quality checks
6. Suitable For
- Research laboratories
- Quality-control laboratories
- Environmental laboratories
- Water-testing laboratories
- Educational institutions
- Industrial laboratories
- Pharmaceutical and chemical laboratories
- Food and beverage laboratories
- Water-treatment operations
- Field testing personnel
- Researchers and laboratory technicians
7. FAQs
1. What is the Labmart LMCM2P used for?
The LMCM2P is a portable meter designed to measure conductivity, TDS and temperature.
2. What is the conductivity range of the LMCM2P?
The conductivity range is 0 to 20.00, 200.0 and 2000 µS/cm, and 20.00 and 200.0 mS/cm with automatic ranging.
3. Can the LMCM2P measure TDS?
Yes. The LMCM2P provides TDS measurement with ranges from 0~10.00, 100.0 and 1000 ppm to 10.00 and 200.0 ppt.
4. How many calibration points does the LMCM2P support?
The meter supports 1 to 3 point conductivity calibration.
5. Does the meter have automatic temperature compensation?
Yes. Temperature compensation can be operated in manual or automatic mode, over 0 to 100°C.
6. What cell constants are supported?
The LMCM2P supports selectable cell constants of K = 0.1, 1 and 10.
7. How many readings can be stored?
The internal memory stores up to 100 data sets.
8. Does the LMCM2P have a backlit display?
Yes. It uses an LCD with white backlight.
9. What power supply does the meter use?
It operates on 3 × 1.5V AA batteries or a 5V DC power adapter.
10. Is a conductivity electrode included?
Yes. A 1K conductivity electrode is listed among the standard accessories.
11. Is a conductivity calibration solution included?
Yes. The standard supply includes a 1413 µS/cm conductivity standard solution.
12. Does the LMCM2P come with a carrying case?
Yes. The catalogue specifies that the carrying case is standard supply.
Similar Products
-
Sale
Vendor: Labmart
Digital PH Meter & TDS Meter Combo with buffer,3 in 1 TDS EC Meter & Temperature,0.01 PH High Accuracy PH Meter with 0-14 pH range & +/- 2% Accuracy I 1 year Warranty
1 reviewSale price Rs.520.00Regular price Rs.1,000.00 -
Sale
Vendor: Acutek
7-in-1 Multiparameter, PH/TDS/EC/Salinity/ Temp/ORP/SG. Meter,Water Quality Analyzer
1 reviewSale price Rs.2,799.00Regular price Rs.4,500.00 -
Sale
Vendor: Acutek
5-in-1 Multiparameter, PH/TDS/EC/Salinity/ Temp. Meter,Water Quality Analyzer
1 reviewSale price Rs.1,850.00Regular price Rs.3,400.00 -
Sale
Vendor: Acutek
4-in-1 Combo PH/TDS/EC/Temp. Meter,Water Quality Analyzer
1 reviewSale price Rs.1,500.00Regular price Rs.3,000.00