Model ISE-NH4 to ISE-NH3 – These solid state ion selective electrodes measure a single ion in solution and are available for 16 ions, from ammonium and nitrate to fluoride, chloride and sodium. They have a BNC connector, a built-in dry reference electrode and need no filling solution or membrane replacement, so they suit laboratory and field work.
Key Features
- Rugged solid state sensors with BNC connector
- Built-in dry reference electrode
- No filling solutions
- No membrane replacements
- Waterproof and submersible
- Suitable for laboratory and field work
- Compatible with all pH and ion meters (except sodium and ammonia electrodes)
Technical Specifications
| Parameter | Specification |
|---|---|
| Models | ISE-NH4, ISE-Br, ISE-Cd, ISE-Ca, ISE-Cl, ISE-Cu, ISE-CN, ISE-F, ISE-I, ISE-Pb, ISE-NO3, ISE-K, ISE-Ag, ISE-Na, ISE-S, ISE-NH3 |
| Sensor type | Solid state |
| Connector | BNC |
| Reference electrode | Built-in dry reference |
| Filling solution | Not required |
| Membrane replacement | Not required |
| Construction | Waterproof and submersible |
| Ammonium (NH4+) – ISE-NH4 | 0.1 to 18000 ppm |
| Bromide (Br-) – ISE-Br | 0.4 to 81000 ppm |
| Cadmium (Cd2+) – ISE-Cd | 0.1 to 11200 ppm |
| Calcium (Ca2+) – ISE-Ca | 0.02 to 40100 ppm |
| Chloride (Cl-) – ISE-Cl | 1 to 35000 ppm |
| Cupric (Cu2+) – ISE-Cu | 0.06 to 6400 ppm |
| Cyanide (CN-) – ISE-CN | 0.03 to 260 ppm |
| Fluoride (F-) – ISE-F | 0.02 to 1900 ppm |
| Iodide (I-) – ISE-I | 0.06 to 127000 ppm |
| Lead (Pb2+) – ISE-Pb | 0.2 to 20800 ppm |
| Nitrate (NO3-) – ISE-NO3 | 0.4 to 62000 ppm |
| Potassium (K+) – ISE-K | 0.04 to 39000 ppm |
| Silver (Ag+) – ISE-Ag | 0.01 to 107900 ppm |
| Sodium (Na+) – ISE-Na | 0.002 to 69000 ppm |
| Sulfide (S2-) – ISE-S | 0.003 to 32000 ppm |
| Ammonia (NH3) – ISE-NH3 | 0.01 to 17000 ppm |
Supplied With
- Ion selective electrode (selected ion)
- 100 ml of 1000 ppm standard solution
- 25 ml of ionic strength adjuster
- Instruction manual
Delivery Period – 10 days
Frequently Asked Questions
Do you provide a GST invoice and bulk or institutional quotation?
Yes. A GST invoice is provided with every order, and quotations for colleges, hospitals, pharma companies and government labs, including bulk orders, are available on request.
What is the HSN code?
HSN code 90275090.
Which ions can be measured?
Ammonium, bromide, cadmium, calcium, chloride, cupric, cyanide, fluoride, iodide, lead, nitrate, potassium, silver, sodium, sulfide and ammonia. Choose the ion from the variant list.
Which meters can I use it with?
It has a BNC connector and works with all pH and ion meters, except the sodium and ammonia electrodes, which are not compatible with all meters. Please confirm your meter model with us before ordering these two.
What warranty is provided?
12 months from the date of dispatch against manufacturing defects. Fragile parts and third-party parts are excluded.
What is the delivery time?
Delivery period is 10 days. Freight is charged extra.
What is supplied with the product?
See the Supplied With list above.
What are the power requirements?
Not applicable (accessory) unless stated in the specifications.
Is installation support available?
Yes. Online installation and operating guidance is provided.
Can your team help me choose the right model?
Yes. Our technical team can help you compare models and choose the right capacity or class for your application.
Labnex
Ion Selective Electrode (ISE), Solid State, BNC Connector, 16 Ion Options, Lab & Field
- Regular price
- Rs.78,099.00
- Sale price
- Rs.48,799.00
Sale
Model ISE-NH4 to ISE-NH3 – These solid state ion selective electrodes measure a single ion in solution and are available for 16 ions, from ammonium and nitrate to fluoride, chloride and sodium. They have a BNC connector, a built-in dry reference electrode and need no filling solution or membrane replacement, so they suit laboratory and field work.
Key Features
- Rugged solid state sensors with BNC connector
- Built-in dry reference electrode
- No filling solutions
- No membrane replacements
- Waterproof and submersible
- Suitable for laboratory and field work
- Compatible with all pH and ion meters (except sodium and ammonia electrodes)
Technical Specifications
| Parameter | Specification |
|---|---|
| Models | ISE-NH4, ISE-Br, ISE-Cd, ISE-Ca, ISE-Cl, ISE-Cu, ISE-CN, ISE-F, ISE-I, ISE-Pb, ISE-NO3, ISE-K, ISE-Ag, ISE-Na, ISE-S, ISE-NH3 |
| Sensor type | Solid state |
| Connector | BNC |
| Reference electrode | Built-in dry reference |
| Filling solution | Not required |
| Membrane replacement | Not required |
| Construction | Waterproof and submersible |
| Ammonium (NH4+) – ISE-NH4 | 0.1 to 18000 ppm |
| Bromide (Br-) – ISE-Br | 0.4 to 81000 ppm |
| Cadmium (Cd2+) – ISE-Cd | 0.1 to 11200 ppm |
| Calcium (Ca2+) – ISE-Ca | 0.02 to 40100 ppm |
| Chloride (Cl-) – ISE-Cl | 1 to 35000 ppm |
| Cupric (Cu2+) – ISE-Cu | 0.06 to 6400 ppm |
| Cyanide (CN-) – ISE-CN | 0.03 to 260 ppm |
| Fluoride (F-) – ISE-F | 0.02 to 1900 ppm |
| Iodide (I-) – ISE-I | 0.06 to 127000 ppm |
| Lead (Pb2+) – ISE-Pb | 0.2 to 20800 ppm |
| Nitrate (NO3-) – ISE-NO3 | 0.4 to 62000 ppm |
| Potassium (K+) – ISE-K | 0.04 to 39000 ppm |
| Silver (Ag+) – ISE-Ag | 0.01 to 107900 ppm |
| Sodium (Na+) – ISE-Na | 0.002 to 69000 ppm |
| Sulfide (S2-) – ISE-S | 0.003 to 32000 ppm |
| Ammonia (NH3) – ISE-NH3 | 0.01 to 17000 ppm |
Supplied With
- Ion selective electrode (selected ion)
- 100 ml of 1000 ppm standard solution
- 25 ml of ionic strength adjuster
- Instruction manual
Delivery Period – 10 days
Frequently Asked Questions
Do you provide a GST invoice and bulk or institutional quotation?
Yes. A GST invoice is provided with every order, and quotations for colleges, hospitals, pharma companies and government labs, including bulk orders, are available on request.
What is the HSN code?
HSN code 90275090.
Which ions can be measured?
Ammonium, bromide, cadmium, calcium, chloride, cupric, cyanide, fluoride, iodide, lead, nitrate, potassium, silver, sodium, sulfide and ammonia. Choose the ion from the variant list.
Which meters can I use it with?
It has a BNC connector and works with all pH and ion meters, except the sodium and ammonia electrodes, which are not compatible with all meters. Please confirm your meter model with us before ordering these two.
What warranty is provided?
12 months from the date of dispatch against manufacturing defects. Fragile parts and third-party parts are excluded.
What is the delivery time?
Delivery period is 10 days. Freight is charged extra.
What is supplied with the product?
See the Supplied With list above.
What are the power requirements?
Not applicable (accessory) unless stated in the specifications.
Is installation support available?
Yes. Online installation and operating guidance is provided.
Can your team help me choose the right model?
Yes. Our technical team can help you compare models and choose the right capacity or class for your application.
- Regular price
- Rs.78,099.00
- Sale price
- Rs.48,799.00
Sale
GST Invoice included
(Save 18% on business purchases)
Need Quote ?
Get Bulk Order Quotation for your lab or Tender Quotation at special discounts !
Contact our support team at support@labmart.in to get the best quote for your bulk order requirement.
Sales Support - +918920746300
Technical Support- +919667893959
Kindly allow us a time of 2-3 days to properly match all the inquired specs, we will also provide authorization(s) to dealers for particular tenders (on tender basis)

-
Free Shipping
Orders above Rs. 1000.
-
On Time Delivery
Within 7 days.
-
Money Back Guarantee
14 day Return*
-
Service Support
Online Installation Support.
Product Description
Model ISE-NH4 to ISE-NH3 – These solid state ion selective electrodes measure a single ion in solution and are available for 16 ions, from ammonium and nitrate to fluoride, chloride and sodium. They have a BNC connector, a built-in dry reference electrode and need no filling solution or membrane replacement, so they suit laboratory and field work.
Key Features
- Rugged solid state sensors with BNC connector
- Built-in dry reference electrode
- No filling solutions
- No membrane replacements
- Waterproof and submersible
- Suitable for laboratory and field work
- Compatible with all pH and ion meters (except sodium and ammonia electrodes)
Technical Specifications
| Parameter | Specification |
|---|---|
| Models | ISE-NH4, ISE-Br, ISE-Cd, ISE-Ca, ISE-Cl, ISE-Cu, ISE-CN, ISE-F, ISE-I, ISE-Pb, ISE-NO3, ISE-K, ISE-Ag, ISE-Na, ISE-S, ISE-NH3 |
| Sensor type | Solid state |
| Connector | BNC |
| Reference electrode | Built-in dry reference |
| Filling solution | Not required |
| Membrane replacement | Not required |
| Construction | Waterproof and submersible |
| Ammonium (NH4+) – ISE-NH4 | 0.1 to 18000 ppm |
| Bromide (Br-) – ISE-Br | 0.4 to 81000 ppm |
| Cadmium (Cd2+) – ISE-Cd | 0.1 to 11200 ppm |
| Calcium (Ca2+) – ISE-Ca | 0.02 to 40100 ppm |
| Chloride (Cl-) – ISE-Cl | 1 to 35000 ppm |
| Cupric (Cu2+) – ISE-Cu | 0.06 to 6400 ppm |
| Cyanide (CN-) – ISE-CN | 0.03 to 260 ppm |
| Fluoride (F-) – ISE-F | 0.02 to 1900 ppm |
| Iodide (I-) – ISE-I | 0.06 to 127000 ppm |
| Lead (Pb2+) – ISE-Pb | 0.2 to 20800 ppm |
| Nitrate (NO3-) – ISE-NO3 | 0.4 to 62000 ppm |
| Potassium (K+) – ISE-K | 0.04 to 39000 ppm |
| Silver (Ag+) – ISE-Ag | 0.01 to 107900 ppm |
| Sodium (Na+) – ISE-Na | 0.002 to 69000 ppm |
| Sulfide (S2-) – ISE-S | 0.003 to 32000 ppm |
| Ammonia (NH3) – ISE-NH3 | 0.01 to 17000 ppm |
Supplied With
- Ion selective electrode (selected ion)
- 100 ml of 1000 ppm standard solution
- 25 ml of ionic strength adjuster
- Instruction manual
Delivery Period – 10 days
Frequently Asked Questions
Do you provide a GST invoice and bulk or institutional quotation?
Yes. A GST invoice is provided with every order, and quotations for colleges, hospitals, pharma companies and government labs, including bulk orders, are available on request.
What is the HSN code?
HSN code 90275090.
Which ions can be measured?
Ammonium, bromide, cadmium, calcium, chloride, cupric, cyanide, fluoride, iodide, lead, nitrate, potassium, silver, sodium, sulfide and ammonia. Choose the ion from the variant list.
Which meters can I use it with?
It has a BNC connector and works with all pH and ion meters, except the sodium and ammonia electrodes, which are not compatible with all meters. Please confirm your meter model with us before ordering these two.
What warranty is provided?
12 months from the date of dispatch against manufacturing defects. Fragile parts and third-party parts are excluded.
What is the delivery time?
Delivery period is 10 days. Freight is charged extra.
What is supplied with the product?
See the Supplied With list above.
What are the power requirements?
Not applicable (accessory) unless stated in the specifications.
Is installation support available?
Yes. Online installation and operating guidance is provided.
Can your team help me choose the right model?
Yes. Our technical team can help you compare models and choose the right capacity or class for your application.
Similar Products
-
Sale
Vendor: Erma
PH Electrode Unbreakable
Sale price Rs.890.00Regular price Rs.1,600.00 -
Sale
Vendor: Labtical
Ion Selective Electrode - Nitrate, compatible with other ION Meters
No reviewsSale price Rs.26,999.00Regular price Rs.50,000.00 -
Sale
Vendor: Acutek
Combination pH Electrode PE-04 – Gel Filled, BNC Connector | Acutek
No reviewsSale price Rs.1,299.00Regular price Rs.2,000.00 -
Sale
Vendor: Chemlab
PH Electrode Plastic
Sale price Rs.900.00Regular price Rs.1,500.00