Product Description

The LABMAN KFT250VC Karl Fischer Titrator is a high-performance moisture analysis system that combines Volumetric and Coulometric Karl Fischer titration in a single instrument, making it suitable for both trace and high moisture determination. Designed for laboratories in pharmaceuticals, chemicals, petrochemicals, food, research, and quality control, it delivers accurate, reliable, and repeatable moisture measurements across a wide range of sample types

Features

  • LCD display with detailed presentation of titration methods, curves and results

  • Supports both Volumetric and Coulometric Karl Fischer Titration in a single instrument

  • Advanced data analysis function for reviewing and comparing results

  • RS232C communication interface

  • Reset and Factory Reset functions

  • Stores up to 200 titration data sets with GLP-compliant data management

  • Multiple selectable measurement units including mg, mg/L, %, ppm, μg and μg/mL

  • Automatic and manual background drift correction for improved measurement accuracy

  • Generator cell with diaphragm for coulometric moisture analysis

  • Automatic reagent filling, purging and mixing for safe handling of Karl Fischer reagents

  • User-configurable operating parameters including:

    • Measurement unit

    • Polarization current

    • Stirring speed

    • Titration rate

    • Generator current

    • End-point potential

    • Stop criterion

    • Stop volume

  • Supports multiple analysis modes:

    • KF Titration Mode

    • KF Titer Detection Mode

    • Volumetric Karl Fischer Titration

    • Coulometric Karl Fischer Titration

  • Suitable for both trace moisture and higher moisture determination using dedicated coulometric and volumetric systems


Technical Specifications

Parameter Specification (KFT250VC)
Model KFT250VC
Make LABMAN
Operating Modes Volumetric Titration & Coulometric Titration
Volumetric Titration Range 0.1 mg – 250 mg
Volumetric Polarization Current Accuracy 1 μA ±0.2 μA, 50 μA ±10 μA
Volumetric Repeatability ±0.5%
Coulometric Titration Range 10 μg – 20 mA
Coulometric Polarization Current Accuracy 50 μA; 1 μA ±0.2 μA, ±10 μA
Coulometric Electrolytic Current 10 mA, 20 mA, 50 mA, 100 mA
Coulometric Electrolytic Current Accuracy ±(5% + 3) μg
Coulometric Repeatability ≤3%
Display LCD Display
Memory Capacity 200 Data Sets
Measurement Units mg, mg/L, %, ppm
Reset Function Yes
Communication Interface RS232C
Power Supply AC 220 V / 50 Hz
Dimensions (L × W × H) 540 × 500 × 480 mm
Gross Weight 12.5 kg

Standard Configuration

  • Integrated Volumetric Karl Fischer Titration System

  • Integrated Coulometric Karl Fischer Titration System

  • Coulometric Electrolytic Cell with Diaphragm (for trace moisture samples)

  • Volumetric Sample Titration Unit (for constant/higher moisture samples)