You need to choose options for product.
Sale
-
files/63e05e61facd97752820cfd0-azzota-spectrophotometer-calibration.jpg
-
files/343746864.jpg
-
files/cals-8-spectrophotometer-validation-filter-set-of-8-items.jpg
3 main tests can be performed using this set
-
Photometric accuracy: Users can use the 3 density filters and plot a standard curve, then check the R value. The closer the R value is to 1, the more accurate the photometric accuracy of the spectrophotometer.
-
Wavelength Accuracy: Users can scan the Holmium and Didymium filter and match all peaks as shown in the test report provided along.
-
Stray Light: 220 nm filter is to test stray light in the lower UV range. 340 nm filter is to test stray light in higher UV range. The absorption in both cases should be equal to or greater than 3.
#1 - 10%T filter
#2 - 20%T filter
#3 - 30%T filter
#4 - 220 nm stray light filter
#5 - 360 nm stray light filter
#6 - Holmium filter (wavelength accuracy test) #7 - Didymium filter (wavelength accuracy test) #8 - BLANK filter
Accuracy: +/-0.2 nm or +/-1%
Each part is mounted in a standard 10 mm cuvette metal holder
Operating temperature: 21°C to 25°C
- Regular price
- Rs.44,000.00
- Sale price
- Rs.35,999.00
Sale
3 main tests can be performed using this set
-
Photometric accuracy: Users can use the 3 density filters and plot a standard curve, then check the R value. The closer the R value is to 1, the more accurate the photometric accuracy of the spectrophotometer.
-
Wavelength Accuracy: Users can scan the Holmium and Didymium filter and match all peaks as shown in the test report provided along.
-
Stray Light: 220 nm filter is to test stray light in the lower UV range. 340 nm filter is to test stray light in higher UV range. The absorption in both cases should be equal to or greater than 3.
#1 - 10%T filter
#2 - 20%T filter
#3 - 30%T filter
#4 - 220 nm stray light filter
#5 - 360 nm stray light filter
#6 - Holmium filter (wavelength accuracy test) #7 - Didymium filter (wavelength accuracy test) #8 - BLANK filter
Accuracy: +/-0.2 nm or +/-1%
Each part is mounted in a standard 10 mm cuvette metal holder
Operating temperature: 21°C to 25°C
- Regular price
- Rs.44,000.00
- Sale price
- Rs.35,999.00
Sale
Couldn't load pickup availability
- Delivery Period :5-7 Working Days
- Replacement :3 Days Replacement as standard, Free of Cost
- Dedicated Support :Support from 9:30 AM to 6:00 PM everyday
Product Description
3 main tests can be performed using this set
-
Photometric accuracy: Users can use the 3 density filters and plot a standard curve, then check the R value. The closer the R value is to 1, the more accurate the photometric accuracy of the spectrophotometer.
-
Wavelength Accuracy: Users can scan the Holmium and Didymium filter and match all peaks as shown in the test report provided along.
-
Stray Light: 220 nm filter is to test stray light in the lower UV range. 340 nm filter is to test stray light in higher UV range. The absorption in both cases should be equal to or greater than 3.
#1 - 10%T filter
#2 - 20%T filter
#3 - 30%T filter
#4 - 220 nm stray light filter
#5 - 360 nm stray light filter
#6 - Holmium filter (wavelength accuracy test) #7 - Didymium filter (wavelength accuracy test) #8 - BLANK filter
Accuracy: +/-0.2 nm or +/-1%
Each part is mounted in a standard 10 mm cuvette metal holder
Operating temperature: 21°C to 25°C
Similar Products
-
Vendor: Acutek
Didymium Glass Filter
No reviewsRegular price Rs.6,999.00 -
Sale
Vendor: Acutek
Holmium Glass Filter
No reviewsSale price Rs.12,999.00Regular price Rs.18,000.00 -
Sale
Vendor: Labmart
Fluorometer Cuvette Cells (4 side polished),Set of 2
No reviewsSale price From Rs.4,999.00Regular price Rs.8,000.00 -
Sale
Vendor: Labmart
Quartz Spectrophotometer Cell Micro cuvette Black Walls 1.4ml
No reviewsSale price Rs.9,999.00Regular price Rs.20,000.00
Customers also bought
Complementary products
-
Free Shipping
Orders above Rs. 1000.
-
On Time Delivery
Within 7 days.
-
Money Back Guarantee
14 day Return*
-
Service Support
Online Installation Support.