You need to choose options for product.
Sale
-
files/labman-aas8a-atomic-absorption-spectrophotometer-250x250.webp
-
files/H342e7d5281e84a22b632d65a1271be58L.jpg
-
files/Hda9f01dc06544cbda5b8d82d57304e85O.jpg
-
files/images_1_b757efd9-c94e-42fe-9052-b3bb146dfc53.jpg
The LABMAN AAS8A is an automatic atomic absorption spectrophotometer with an 8-lamp option for flame and graphite furnace analysis of metal elements. It covers 190–900 nm with a Czerny-Turner closed optical system, 1800 lines/mm grating, automatic gas control and a Cu detection limit of 0.004 µg/ml.
Key features
- Flame and graphite furnace operation; auto sampler and refrigerated circulating bath can be attached as options
- Automatic gas control and optimisation of flow and pressure; argon is required for graphite furnace
- 8 lamp sockets
- Czerny-Turner closed optical system on an integrated optical bench
- 6-gear automatic slit switching from 0.1 to 2.0 nm
- Background correction by high speed self-reversal (BGC-SR) or D2 lamp (BGC-D2)
- Copper hollow cathode lamp supplied as standard; other lamps optional
- Standard software supplied; computer not included
Technical specifications
| Parameter | Specification |
|---|---|
| Model | AAS8A |
| Make | LABMAN |
| Operation setting | Automatic |
| Lamp socket options | 8 lamps |
| Detection limit | Cu ≤ 0.004 µg/ml |
| Wavelength range | 190–900 nm |
| Scintillation wavelength | 250 nm |
| Grating system | 1800 lines/mm, characterisation area 40 mm² |
| Wavelength repeatability | ±0.1 nm |
| Wavelength accuracy | ±0.2 nm |
| Optical system | Czerny-Turner, integrated optical bench, closed optical system |
| Resolution | Spectral bandwidth 0.2 nm separates the Mn 279.5 / 279.8 nm double line and peak-valley |
| Instrument type | Single beam reflection achromatic optics |
| Spectrum slit | 6-gear automatic switching (0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm) |
| Photometric range | 0–125%, –0.1 to 3.00 A |
| Static baseline drift | ≤ 0.002 ABS / 30 min (Cu) |
| Background correction | High speed self-reversal (BGC-SR), high speed D2 lamp (BGC-D2) |
| Combustion head | Air-acetylene flame combustion head, 100 mm |
| Sprayer | High efficiency glass sprayer |
| Dynamic drift of ignition | Baseline ≤ 0.004 ABS / 30 min (Cu) |
| Characteristic concentration of Cu | 0.025 µg/ml/1% (Cu, ABS > 0.8) |
| Measurement repeatability (Cu) | RSD < 0.5% |
| Ambient temperature | 10°C to 30°C |
| Standard lamp | Cu |
| Software | Supplied with instrument |
| Power supply | AC 220 V, 50–60 Hz (without power fluctuation) |
| Machine dimension (L×W×H) | 710 × 560 × 420 mm |
| Packed in | Wooden box |
| Packing dimension (L×W×H) | 860 × 710 × 760 mm |
| Net weight | 58 kg |
| Gross weight | 93 kg |
| HSN code | 90273020 |
Supplied with
Main instrument, Cu hollow cathode lamp, software. A computer is not supplied; the user must have a computer to run the software. Instruction manual, test certificate.
Frequently asked questions
What is the difference between the AAS8A and AAS4M?
The AAS8A is automatic with 8 lamp sockets, supports flame and graphite furnace, and has a lower Cu detection limit (0.004 µg/ml versus 0.008 µg/ml). The AAS4M is manual with 4 lamps and flame only.
Can I use a graphite furnace with it?
Yes. The graphite furnace GF3000 and the 85-position auto sampler ASG85 are available as accessories at additional cost. Argon gas is required for graphite operation.
Which accessories are recommended?
Oil-free air compressor ACOF30, graphite furnace GF3000, auto sampler ASG85, a refrigerated circulating bath for stable graphite furnace cooling, and hollow cathode lamps for the elements you test.
Which hollow cathode lamps are available?
Cu, Zn, Fe, Mn, Pb, Mg, Ni, Cd, Ca, Cr, Li and Co. Copper is supplied as standard.
Is a computer included?
No. The software is supplied with the instrument but you need your own computer.
What power supply does it need?
AC 220 V, 50–60 Hz (without power fluctuation).
What is supplied with it?
Main instrument, Cu hollow cathode lamp, software. A computer is not supplied; the user must have a computer to run the software. Instruction manual, test certificate.
What are the packing size and weight?
860 × 710 × 760 mm (L×W×H as per catalogue), gross weight 93 kg.
Can I get a GST invoice and a bulk or institutional quotation?
Yes. Labmart (Chemlab Equipment) supplies against a GST invoice and provides quotations for colleges, hospitals, pharma companies and government labs, including bulk and tender requirements. Contact us with your requirement for a formal quotation.
What is the warranty and delivery time?
LABMAN instruments supplied by Labmart carry a standard 13-month warranty. Delivery time depends on your location and stock, so please contact Labmart for a delivery estimate.
Labman
AAS8A Atomic Absorption Spectrophotometer – Automatic, 8-Lamp Turret, Flame & Graphite Furnace Ready, 190–900 nm, Free Onsite Installation
- Regular price
- Rs.1,353,999.00
- Sale price
- Rs.902,999.00
Sale
The LABMAN AAS8A is an automatic atomic absorption spectrophotometer with an 8-lamp option for flame and graphite furnace analysis of metal elements. It covers 190–900 nm with a Czerny-Turner closed optical system, 1800 lines/mm grating, automatic gas control and a Cu detection limit of 0.004 µg/ml.
Key features
- Flame and graphite furnace operation; auto sampler and refrigerated circulating bath can be attached as options
- Automatic gas control and optimisation of flow and pressure; argon is required for graphite furnace
- 8 lamp sockets
- Czerny-Turner closed optical system on an integrated optical bench
- 6-gear automatic slit switching from 0.1 to 2.0 nm
- Background correction by high speed self-reversal (BGC-SR) or D2 lamp (BGC-D2)
- Copper hollow cathode lamp supplied as standard; other lamps optional
- Standard software supplied; computer not included
Technical specifications
| Parameter | Specification |
|---|---|
| Model | AAS8A |
| Make | LABMAN |
| Operation setting | Automatic |
| Lamp socket options | 8 lamps |
| Detection limit | Cu ≤ 0.004 µg/ml |
| Wavelength range | 190–900 nm |
| Scintillation wavelength | 250 nm |
| Grating system | 1800 lines/mm, characterisation area 40 mm² |
| Wavelength repeatability | ±0.1 nm |
| Wavelength accuracy | ±0.2 nm |
| Optical system | Czerny-Turner, integrated optical bench, closed optical system |
| Resolution | Spectral bandwidth 0.2 nm separates the Mn 279.5 / 279.8 nm double line and peak-valley |
| Instrument type | Single beam reflection achromatic optics |
| Spectrum slit | 6-gear automatic switching (0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm) |
| Photometric range | 0–125%, –0.1 to 3.00 A |
| Static baseline drift | ≤ 0.002 ABS / 30 min (Cu) |
| Background correction | High speed self-reversal (BGC-SR), high speed D2 lamp (BGC-D2) |
| Combustion head | Air-acetylene flame combustion head, 100 mm |
| Sprayer | High efficiency glass sprayer |
| Dynamic drift of ignition | Baseline ≤ 0.004 ABS / 30 min (Cu) |
| Characteristic concentration of Cu | 0.025 µg/ml/1% (Cu, ABS > 0.8) |
| Measurement repeatability (Cu) | RSD < 0.5% |
| Ambient temperature | 10°C to 30°C |
| Standard lamp | Cu |
| Software | Supplied with instrument |
| Power supply | AC 220 V, 50–60 Hz (without power fluctuation) |
| Machine dimension (L×W×H) | 710 × 560 × 420 mm |
| Packed in | Wooden box |
| Packing dimension (L×W×H) | 860 × 710 × 760 mm |
| Net weight | 58 kg |
| Gross weight | 93 kg |
| HSN code | 90273020 |
Supplied with
Main instrument, Cu hollow cathode lamp, software. A computer is not supplied; the user must have a computer to run the software. Instruction manual, test certificate.
Frequently asked questions
What is the difference between the AAS8A and AAS4M?
The AAS8A is automatic with 8 lamp sockets, supports flame and graphite furnace, and has a lower Cu detection limit (0.004 µg/ml versus 0.008 µg/ml). The AAS4M is manual with 4 lamps and flame only.
Can I use a graphite furnace with it?
Yes. The graphite furnace GF3000 and the 85-position auto sampler ASG85 are available as accessories at additional cost. Argon gas is required for graphite operation.
Which accessories are recommended?
Oil-free air compressor ACOF30, graphite furnace GF3000, auto sampler ASG85, a refrigerated circulating bath for stable graphite furnace cooling, and hollow cathode lamps for the elements you test.
Which hollow cathode lamps are available?
Cu, Zn, Fe, Mn, Pb, Mg, Ni, Cd, Ca, Cr, Li and Co. Copper is supplied as standard.
Is a computer included?
No. The software is supplied with the instrument but you need your own computer.
What power supply does it need?
AC 220 V, 50–60 Hz (without power fluctuation).
What is supplied with it?
Main instrument, Cu hollow cathode lamp, software. A computer is not supplied; the user must have a computer to run the software. Instruction manual, test certificate.
What are the packing size and weight?
860 × 710 × 760 mm (L×W×H as per catalogue), gross weight 93 kg.
Can I get a GST invoice and a bulk or institutional quotation?
Yes. Labmart (Chemlab Equipment) supplies against a GST invoice and provides quotations for colleges, hospitals, pharma companies and government labs, including bulk and tender requirements. Contact us with your requirement for a formal quotation.
What is the warranty and delivery time?
LABMAN instruments supplied by Labmart carry a standard 13-month warranty. Delivery time depends on your location and stock, so please contact Labmart for a delivery estimate.
- Regular price
- Rs.1,353,999.00
- Sale price
- Rs.902,999.00
Sale
GST Invoice included
(Save 18% on business purchases)
Need Quote ?
Get Bulk Order Quotation for your lab or Tender Quotation at special discounts !
Contact our support team at support@labmart.in to get the best quote for your bulk order requirement.
Sales Support - +918920746300
Technical Support- +919667893959
Kindly allow us a time of 2-3 days to properly match all the inquired specs, we will also provide authorization(s) to dealers for particular tenders (on tender basis)

-
Free Shipping
Orders above Rs. 1000.
-
On Time Delivery
Within 7 days.
-
Money Back Guarantee
14 day Return*
-
Service Support
Online Installation Support.
Product Description
The LABMAN AAS8A is an automatic atomic absorption spectrophotometer with an 8-lamp option for flame and graphite furnace analysis of metal elements. It covers 190–900 nm with a Czerny-Turner closed optical system, 1800 lines/mm grating, automatic gas control and a Cu detection limit of 0.004 µg/ml.
Key features
- Flame and graphite furnace operation; auto sampler and refrigerated circulating bath can be attached as options
- Automatic gas control and optimisation of flow and pressure; argon is required for graphite furnace
- 8 lamp sockets
- Czerny-Turner closed optical system on an integrated optical bench
- 6-gear automatic slit switching from 0.1 to 2.0 nm
- Background correction by high speed self-reversal (BGC-SR) or D2 lamp (BGC-D2)
- Copper hollow cathode lamp supplied as standard; other lamps optional
- Standard software supplied; computer not included
Technical specifications
| Parameter | Specification |
|---|---|
| Model | AAS8A |
| Make | LABMAN |
| Operation setting | Automatic |
| Lamp socket options | 8 lamps |
| Detection limit | Cu ≤ 0.004 µg/ml |
| Wavelength range | 190–900 nm |
| Scintillation wavelength | 250 nm |
| Grating system | 1800 lines/mm, characterisation area 40 mm² |
| Wavelength repeatability | ±0.1 nm |
| Wavelength accuracy | ±0.2 nm |
| Optical system | Czerny-Turner, integrated optical bench, closed optical system |
| Resolution | Spectral bandwidth 0.2 nm separates the Mn 279.5 / 279.8 nm double line and peak-valley |
| Instrument type | Single beam reflection achromatic optics |
| Spectrum slit | 6-gear automatic switching (0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm) |
| Photometric range | 0–125%, –0.1 to 3.00 A |
| Static baseline drift | ≤ 0.002 ABS / 30 min (Cu) |
| Background correction | High speed self-reversal (BGC-SR), high speed D2 lamp (BGC-D2) |
| Combustion head | Air-acetylene flame combustion head, 100 mm |
| Sprayer | High efficiency glass sprayer |
| Dynamic drift of ignition | Baseline ≤ 0.004 ABS / 30 min (Cu) |
| Characteristic concentration of Cu | 0.025 µg/ml/1% (Cu, ABS > 0.8) |
| Measurement repeatability (Cu) | RSD < 0.5% |
| Ambient temperature | 10°C to 30°C |
| Standard lamp | Cu |
| Software | Supplied with instrument |
| Power supply | AC 220 V, 50–60 Hz (without power fluctuation) |
| Machine dimension (L×W×H) | 710 × 560 × 420 mm |
| Packed in | Wooden box |
| Packing dimension (L×W×H) | 860 × 710 × 760 mm |
| Net weight | 58 kg |
| Gross weight | 93 kg |
| HSN code | 90273020 |
Supplied with
Main instrument, Cu hollow cathode lamp, software. A computer is not supplied; the user must have a computer to run the software. Instruction manual, test certificate.
Frequently asked questions
What is the difference between the AAS8A and AAS4M?
The AAS8A is automatic with 8 lamp sockets, supports flame and graphite furnace, and has a lower Cu detection limit (0.004 µg/ml versus 0.008 µg/ml). The AAS4M is manual with 4 lamps and flame only.
Can I use a graphite furnace with it?
Yes. The graphite furnace GF3000 and the 85-position auto sampler ASG85 are available as accessories at additional cost. Argon gas is required for graphite operation.
Which accessories are recommended?
Oil-free air compressor ACOF30, graphite furnace GF3000, auto sampler ASG85, a refrigerated circulating bath for stable graphite furnace cooling, and hollow cathode lamps for the elements you test.
Which hollow cathode lamps are available?
Cu, Zn, Fe, Mn, Pb, Mg, Ni, Cd, Ca, Cr, Li and Co. Copper is supplied as standard.
Is a computer included?
No. The software is supplied with the instrument but you need your own computer.
What power supply does it need?
AC 220 V, 50–60 Hz (without power fluctuation).
What is supplied with it?
Main instrument, Cu hollow cathode lamp, software. A computer is not supplied; the user must have a computer to run the software. Instruction manual, test certificate.
What are the packing size and weight?
860 × 710 × 760 mm (L×W×H as per catalogue), gross weight 93 kg.
Can I get a GST invoice and a bulk or institutional quotation?
Yes. Labmart (Chemlab Equipment) supplies against a GST invoice and provides quotations for colleges, hospitals, pharma companies and government labs, including bulk and tender requirements. Contact us with your requirement for a formal quotation.
What is the warranty and delivery time?
LABMAN instruments supplied by Labmart carry a standard 13-month warranty. Delivery time depends on your location and stock, so please contact Labmart for a delivery estimate.
Similar Products
-
Sale
Vendor: Spectrix
Nano Spectrophotometer I Micro Volume Spectrophotometer I In Built Thermal Printer I FREE ONSITE INSTALLATION
No reviewsSale price Rs.299,999.00Regular price Rs.350,000.00 -
Sale
Vendor: Labman
ASG85 Auto Sampler for Graphite Furnace – 85 Positions, Automatic Calibration Curve and Dilution, USB & RS232C, Free Onsite Installation
No reviewsSale price Rs.496,999.00Regular price Rs.744,999.00 -
Sale
Vendor: Labman
GF3000 Graphite Furnace for AAS – Up to 3000°C, Cd ≤ 1 pg, Longitudinal Heating, Windows Software, Free Onsite Installation
No reviewsSale price Rs.496,999.00Regular price Rs.744,999.00 -
Sale
Vendor: Labman
AAS4M Atomic Absorption Spectrophotometer – Manual, 4-Lamp Turret, Flame (Air-Acetylene), 190–900 nm, Free Onsite Installation
No reviewsSale price Rs.801,999.00Regular price Rs.1,202,999.00