The GC10CI Gas Chromatography system is engineered for high-resolution compound separation and trace-level detection, making it a preferred choice for pharmaceutical labs, environmental testing facilities, and chemical industries. With GLP/FDA 21 CFR Part 11 compliant software, it ensures data integrity, regulatory compliance, and reliable reporting.
Salient Features
-
Control system: Designed for monitoring and controlling the instrument via computer.
-
Column compartment/oven: Superior thermal performance with multistage (10 ramps) programmed temperature control function (supported by control system).
-
Advanced built-in data acquisition system: Supports real-time instrument status monitoring, detection signal acquisition and PC control.
-
Column oven: Accommodates 1 capillary column and supports quick heat-up and rapid cool-down with automated back-door opening.
-
Sample introduction system: One sample injector installed.
-
Sample detection system:
-
1 high sensitivity and stability FID detector for various organic compound applications.
-
-
Analog signal output: 1 output channel.
-
Software compatibility: Compatible with GLP / FDA-21 CFR Part 11 requirements and regulations (electronic records and signatures).
FID General Applications
-
Nitrobenzene compounds
-
Nitrobenzene
-
Dinitrotoluene
-
-
Chlorobenzene compounds
-
Chlorobenzene
-
Dichlorobenzene
-
Trichlorobenzene
-
-
Benzene series
-
Toluene
-
Ethylbenzene
-
O-Xylene
-
M-Xylene
-
P-Xylene
-
Styrene
-
Cumene
-
-
TVOC (Total Volatile Organic Compounds)
-
Phenolic compounds
-
Phenol
-
Cresol
-
Note: Depending on test circumstances, headspace sampler or thermal analysis instrument may be required.
Software: Advanced Computer Control System
-
Superior performance with advanced computer-based temperature control system.
-
High temperature accuracy (±0.02°C optimum).
-
High reliability with anti-interference protection.
-
Self-diagnosis and self-protection functions, including:
-
Overheat protection
-
Power-off protection
-
-
Intuitive display showing:
-
Timing program
-
Detector status
-
Measurement range
-
Current settings
-
Note: Computer is not included with the instrument. User must provide a computer to run the software.
Specifications
Model: GC10CI
HSN Code: 90272000
Standard Accessories
-
Main instrument set
-
Power cord
-
Instruction manual
-
Test certificate
Column Oven
-
Temperature Range: RT +7°C to 400°C (1°C increments)
-
Temperature Accuracy: ±0.02°C
-
Cooling Time: 400°C to 50°C in 8–10 minutes (at 25°C ambient)
-
Programmed Temperature Rate: 0.1°C to 40°C/min (1°C increments)
-
Program Ramps: 7 ramps standard (up to 10 ramps with software)
Dimensions
-
Inside Size (L × W × H): 284 × 280 × 241 mm
-
Outside Size (L × W × H): 340 × 345 × 281 mm
Detector (FID)
-
Detection Limit: ≤ 3 × 10⁻¹² g/s
-
Drift: ≤ 6 × 10⁻¹³ A / 30 min
-
Linearity Range: ≥ 10⁶
Sample Introduction System
-
Capillary injector
Power Requirements
-
Power: 2000 W
-
Power Supply: 220 V / 50 Hz
Packing Information
-
Packing Size: 830 × 680 × 855 mm
-
Gross Weight (Approx.): 79 kg
Optional Accessories
-
Auto Sampler: ASGC22
-
Air source / flow rate control device
- Regular price
- Rs.550,000.00
- Sale price
- Rs.489,000.00
Sale
The GC10CI Gas Chromatography system is engineered for high-resolution compound separation and trace-level detection, making it a preferred choice for pharmaceutical labs, environmental testing facilities, and chemical industries. With GLP/FDA 21 CFR Part 11 compliant software, it ensures data integrity, regulatory compliance, and reliable reporting.
Salient Features
-
Control system: Designed for monitoring and controlling the instrument via computer.
-
Column compartment/oven: Superior thermal performance with multistage (10 ramps) programmed temperature control function (supported by control system).
-
Advanced built-in data acquisition system: Supports real-time instrument status monitoring, detection signal acquisition and PC control.
-
Column oven: Accommodates 1 capillary column and supports quick heat-up and rapid cool-down with automated back-door opening.
-
Sample introduction system: One sample injector installed.
-
Sample detection system:
-
1 high sensitivity and stability FID detector for various organic compound applications.
-
-
Analog signal output: 1 output channel.
-
Software compatibility: Compatible with GLP / FDA-21 CFR Part 11 requirements and regulations (electronic records and signatures).
FID General Applications
-
Nitrobenzene compounds
-
Nitrobenzene
-
Dinitrotoluene
-
-
Chlorobenzene compounds
-
Chlorobenzene
-
Dichlorobenzene
-
Trichlorobenzene
-
-
Benzene series
-
Toluene
-
Ethylbenzene
-
O-Xylene
-
M-Xylene
-
P-Xylene
-
Styrene
-
Cumene
-
-
TVOC (Total Volatile Organic Compounds)
-
Phenolic compounds
-
Phenol
-
Cresol
-
Note: Depending on test circumstances, headspace sampler or thermal analysis instrument may be required.
Software: Advanced Computer Control System
-
Superior performance with advanced computer-based temperature control system.
-
High temperature accuracy (±0.02°C optimum).
-
High reliability with anti-interference protection.
-
Self-diagnosis and self-protection functions, including:
-
Overheat protection
-
Power-off protection
-
-
Intuitive display showing:
-
Timing program
-
Detector status
-
Measurement range
-
Current settings
-
Note: Computer is not included with the instrument. User must provide a computer to run the software.
Specifications
Model: GC10CI
HSN Code: 90272000
Standard Accessories
-
Main instrument set
-
Power cord
-
Instruction manual
-
Test certificate
Column Oven
-
Temperature Range: RT +7°C to 400°C (1°C increments)
-
Temperature Accuracy: ±0.02°C
-
Cooling Time: 400°C to 50°C in 8–10 minutes (at 25°C ambient)
-
Programmed Temperature Rate: 0.1°C to 40°C/min (1°C increments)
-
Program Ramps: 7 ramps standard (up to 10 ramps with software)
Dimensions
-
Inside Size (L × W × H): 284 × 280 × 241 mm
-
Outside Size (L × W × H): 340 × 345 × 281 mm
Detector (FID)
-
Detection Limit: ≤ 3 × 10⁻¹² g/s
-
Drift: ≤ 6 × 10⁻¹³ A / 30 min
-
Linearity Range: ≥ 10⁶
Sample Introduction System
-
Capillary injector
Power Requirements
-
Power: 2000 W
-
Power Supply: 220 V / 50 Hz
Packing Information
-
Packing Size: 830 × 680 × 855 mm
-
Gross Weight (Approx.): 79 kg
Optional Accessories
-
Auto Sampler: ASGC22
-
Air source / flow rate control device
- Regular price
- Rs.550,000.00
- Sale price
- Rs.489,000.00
Sale
Couldn't load pickup availability
- Delivery Period :5-7 Working Days
- Replacement :3 Days Replacement as standard, Free of Cost
- Dedicated Support :Support from 9:30 AM to 6:00 PM everyday
Product Description
The GC10CI Gas Chromatography system is engineered for high-resolution compound separation and trace-level detection, making it a preferred choice for pharmaceutical labs, environmental testing facilities, and chemical industries. With GLP/FDA 21 CFR Part 11 compliant software, it ensures data integrity, regulatory compliance, and reliable reporting.
Salient Features
-
Control system: Designed for monitoring and controlling the instrument via computer.
-
Column compartment/oven: Superior thermal performance with multistage (10 ramps) programmed temperature control function (supported by control system).
-
Advanced built-in data acquisition system: Supports real-time instrument status monitoring, detection signal acquisition and PC control.
-
Column oven: Accommodates 1 capillary column and supports quick heat-up and rapid cool-down with automated back-door opening.
-
Sample introduction system: One sample injector installed.
-
Sample detection system:
-
1 high sensitivity and stability FID detector for various organic compound applications.
-
-
Analog signal output: 1 output channel.
-
Software compatibility: Compatible with GLP / FDA-21 CFR Part 11 requirements and regulations (electronic records and signatures).
FID General Applications
-
Nitrobenzene compounds
-
Nitrobenzene
-
Dinitrotoluene
-
-
Chlorobenzene compounds
-
Chlorobenzene
-
Dichlorobenzene
-
Trichlorobenzene
-
-
Benzene series
-
Toluene
-
Ethylbenzene
-
O-Xylene
-
M-Xylene
-
P-Xylene
-
Styrene
-
Cumene
-
-
TVOC (Total Volatile Organic Compounds)
-
Phenolic compounds
-
Phenol
-
Cresol
-
Note: Depending on test circumstances, headspace sampler or thermal analysis instrument may be required.
Software: Advanced Computer Control System
-
Superior performance with advanced computer-based temperature control system.
-
High temperature accuracy (±0.02°C optimum).
-
High reliability with anti-interference protection.
-
Self-diagnosis and self-protection functions, including:
-
Overheat protection
-
Power-off protection
-
-
Intuitive display showing:
-
Timing program
-
Detector status
-
Measurement range
-
Current settings
-
Note: Computer is not included with the instrument. User must provide a computer to run the software.
Specifications
Model: GC10CI
HSN Code: 90272000
Standard Accessories
-
Main instrument set
-
Power cord
-
Instruction manual
-
Test certificate
Column Oven
-
Temperature Range: RT +7°C to 400°C (1°C increments)
-
Temperature Accuracy: ±0.02°C
-
Cooling Time: 400°C to 50°C in 8–10 minutes (at 25°C ambient)
-
Programmed Temperature Rate: 0.1°C to 40°C/min (1°C increments)
-
Program Ramps: 7 ramps standard (up to 10 ramps with software)
Dimensions
-
Inside Size (L × W × H): 284 × 280 × 241 mm
-
Outside Size (L × W × H): 340 × 345 × 281 mm
Detector (FID)
-
Detection Limit: ≤ 3 × 10⁻¹² g/s
-
Drift: ≤ 6 × 10⁻¹³ A / 30 min
-
Linearity Range: ≥ 10⁶
Sample Introduction System
-
Capillary injector
Power Requirements
-
Power: 2000 W
-
Power Supply: 220 V / 50 Hz
Packing Information
-
Packing Size: 830 × 680 × 855 mm
-
Gross Weight (Approx.): 79 kg
Optional Accessories
-
Auto Sampler: ASGC22
-
Air source / flow rate control device
Similar Products
-
Sale
Vendor: Labman
Gas chromatography I Advanced GC System with EPC & FID Detector I GLP/FDA/CFR Part 11 Complaint
No reviewsSale price Rs.829,999.00Regular price Rs.1,100,000.00 -
Sale
Vendor: Lasany
High-Performance Liquid Chromatography Advanced with (Rheodyne Injector)
Sale price Rs.1,000,000.00Regular price Rs.1,400,000.00 -
Sale
Sold out
Vendor: Lasany
High-Performance Liquid Chromatography Advanced (HPLC LI-6300)
Sale price Rs.850,000.00Regular price Rs.1,150,000.00 -
Sale
Vendor: Lasany
HPLC System With Rheodyne Injector (Model No: LI-6210)
Sale price Rs.635,000.00Regular price Rs.850,000.00
Customers also bought
Complementary products
-
Free Shipping
Orders above Rs. 1000.
-
On Time Delivery
Within 7 days.
-
Money Back Guarantee
14 day Return*
-
Service Support
Online Installation Support.