The Labmart LMCR80F Visual Colorimeter is a laboratory visual colour measuring instrument designed for visual colour matching and measurement using international colour scale units. It supports transmittance and reflectance modes and provides a measurement range of 0.1–79.9 Red, 0.1–79.9 Yellow, 0.1–49.9 Blue and 0.1–3.9 Neutral, with 0.1 colour scale unit resolution.
The LMCR80F features a fully adjustable viewing system, incandescent light source approximating daylight, replaceable sample chamber liner, replaceable light source with two spare incandescent lamps and interchangeable cuvette configurations. It is designed for colour measurement of liquids, gelatin, solids and powders and is used across applications including paints, plastics, textiles, foodstuff, liquid chemicals and pharmaceuticals. LMCR80F
3. Detailed Product Description
Product Overview
The LMCR80F Visual Colorimeter is a visual colour measurement instrument based on internationally acknowledged colour scale units. It is designed to determine material colour through visual colour matching.
The instrument supports both transmittance and reflectance modes and uses an incandescent lamp whose illuminant approximates daylight. The viewing system is fully adjustable, allowing the operator to perform visual colour comparison under controlled instrument conditions. LMCR80F
The LMCR80F is designed for measurement of the colourity of liquid, gelatin, solid and powder samples. The catalogue specifically identifies applications involving grease, paint, plastic, jam, textile fabric, foodstuff, liquid chemicals and pharmaceuticals. LMCR80F
The catalogue also specifies a replaceable sample chamber liner and a replaceable light source, with two spare incandescent lamps included. LMCR80F
4. Key Features & Benefits
- Visual Colour Measurement – Measures colour using international colour scale units.
- Transmittance & Reflectance Modes – Supports two measurement modes.
- Visual Colour Matching – Designed for visual comparison and determination of material colour.
- 0.1 Colour Scale Unit Resolution – Provides fine colour-scale measurement resolution.
- Fully Adjustable Viewing System – Allows adjustment of the viewing arrangement.
- Incandescent Light Source – Uses an incandescent lamp with an illuminant approximating daylight.
- Replaceable Sample Chamber Liner – Facilitates replacement of the sample chamber liner.
- Replaceable Light Source – The light source can be replaced when required.
- Two Spare Incandescent Lamps – Two spare lamps are specified as part of the light-source arrangement.
- Multiple Sample Types – Suitable for liquid, gelatin, solid and powder samples.
- Long Path Length – Path length specified up to 180 mm.
- White Plate Reflectivity >80% – Specified diffuse reflectivity of the white plate.
- 1.9× Magnification – Magnifiers provide 1.9× amplification.
- Simple Structure – Designed for straightforward operation.
- International Colour Scale – Measurement principle is based on internationally accepted colour scale units. LMCR80F
5. Technical Specifications
| Specification | LMCR80F |
|---|---|
| Product Type | Visual Colorimeter |
| Model | LMCR80F |
| Make | LABMAN |
| HSN Code | 90275090 |
| Measuring Principle | Visual, in terms of International colour scale units |
| Measurement Modes | Transmittance, Reflectance |
| Red Measurement Range | 0.1–79.9 |
| Yellow Measurement Range | 0.1–79.9 |
| Blue Measurement Range | 0.1–49.9 |
| Neutral Measurement Range | 0.1–3.9 |
| Resolution | 0.1 colour scale unit |
| Viewing System | Fully adjustable |
| Light Source | Incandescent lamp |
| Illuminant | Approximates to daylight |
| Path Length | Up to 180 mm |
| Diffuse Reflectivity of White Plate | >80% |
| Magnifier Amplification | 1.9× |
| Cuvette Dimensions | 10 × 20 × 40 mm; 25.4 × 20 × 40 mm; 133.4 × 20 × 40 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Packing Dimensions (L × W × H) | 620 × 450 × 310 mm |
| Gross Weight | 10 kg |
| Sample Types | Liquid, gelatin, solid and powder |
The technical specifications are taken from the LMCR80F specification table on page 2 of the supplied catalogue. LMCR80F
6. Measurement Modes
Transmittance
The LMCR80F supports transmittance measurement, suitable for colour evaluation of samples where light transmission through the material is assessed.
Reflectance
The instrument also supports reflectance measurement, allowing visual colour assessment based on reflected light.
Both modes are explicitly specified for the LMCR80F. LMCR80F
7. Measurement Range
| Colour Scale | Measurement Range |
|---|---|
| Red | 0.1–79.9 |
| Yellow | 0.1–79.9 |
| Blue | 0.1–49.9 |
| Neutral | 0.1–3.9 |
| Resolution | 0.1 colour scale unit |
These are the colour-scale ranges stated in the manufacturer's LMCR80F specification table. LMCR80F
8. Sample Types
The LMCR80F is specified for colour measurement of:
- Liquid samples
- Gelatin
- Solid samples
- Powder samples
The catalogue additionally identifies colour measurement applications involving grease, paint, plastic, jam, textile fabric, foodstuff, liquid chemicals and pharmaceuticals. LMCR80F
9. Applications
Paint & Coatings
Colour measurement and matching of paint materials.
Plastics
Visual colour assessment of plastic materials.
Food & Food Products
The catalogue specifically identifies jam and foodstuff among the application materials.
Textile Materials
Suitable for visual colour measurement of textile fabric.
Chemicals
Designed for colour measurement of liquid chemicals.
Pharmaceuticals
The catalogue specifically lists pharmaceuticals among the materials for which the instrument is used. LMCR80F
Grease
The catalogue identifies grease among the materials used for colour measurement.
10. Suitable For
- Quality-control laboratories
- Paint and coatings laboratories
- Plastic testing laboratories
- Food-processing laboratories
- Textile laboratories
- Chemical laboratories
- Pharmaceutical laboratories
- Research laboratories
- Material colour inspection
- Visual colour matching applications
11. FAQs
1. What is the Labmart LMCR80F?
The LMCR80F is a Visual Colorimeter designed for visual colour matching and colour-scale measurement.
2. What measuring principle does it use?
It uses visual measurement in terms of international colour scale units.
3. What measurement modes are available?
The LMCR80F supports transmittance and reflectance.
4. What is the measurement range for Red?
0.1–79.9 Red.
5. What is the Yellow measurement range?
0.1–79.9 Yellow.
6. What is the Blue measurement range?
0.1–49.9 Blue.
7. What is the Neutral measurement range?
0.1–3.9 Neutral.
8. What is the resolution?
The resolution is 0.1 colour scale unit.
9. What type of light source is used?
The instrument uses an incandescent lamp.
10. Does the light source approximate daylight?
Yes. The specified illuminant approximates to daylight.
11. Is the viewing system adjustable?
Yes. The viewing system is fully adjustable.
12. What types of samples can be measured?
The catalogue specifies liquid, gelatin, solid and powder samples.
13. What materials can be tested?
The catalogue identifies grease, paint, plastic, jam, textile fabric, foodstuff, liquid chemicals and pharmaceuticals.
14. Can the sample chamber liner be replaced?
Yes. A replaceable sample chamber liner is one of the salient features.
15. Is the light source replaceable?
Yes. The light source is replaceable, and the catalogue specifies two spare incandescent lamps.
16. What is the maximum path length?
The specified path length is up to 180 mm.
17. What is the white plate reflectivity?
The specified diffuse reflectivity of the white plate is >80%.
18. What is the magnifier amplification?
The magnifiers provide 1.9× amplification.
19. What power supply is required?
AC 220 V, 50/60 Hz.
20. What are the packing dimensions?
620 × 450 × 310 mm (L × W × H).
21. What is the gross weight?
The specified gross weight is 10 kg.
22. What accessories are supplied?
The standard accessories include the main instrument, cuvette lamp, lens tube, power cable, instruction manual and test certificate.
- Regular price
- Rs.121,999.00
- Sale price
- Rs.80,999.00
Sale
The Labmart LMCR80F Visual Colorimeter is a laboratory visual colour measuring instrument designed for visual colour matching and measurement using international colour scale units. It supports transmittance and reflectance modes and provides a measurement range of 0.1–79.9 Red, 0.1–79.9 Yellow, 0.1–49.9 Blue and 0.1–3.9 Neutral, with 0.1 colour scale unit resolution.
The LMCR80F features a fully adjustable viewing system, incandescent light source approximating daylight, replaceable sample chamber liner, replaceable light source with two spare incandescent lamps and interchangeable cuvette configurations. It is designed for colour measurement of liquids, gelatin, solids and powders and is used across applications including paints, plastics, textiles, foodstuff, liquid chemicals and pharmaceuticals. LMCR80F
3. Detailed Product Description
Product Overview
The LMCR80F Visual Colorimeter is a visual colour measurement instrument based on internationally acknowledged colour scale units. It is designed to determine material colour through visual colour matching.
The instrument supports both transmittance and reflectance modes and uses an incandescent lamp whose illuminant approximates daylight. The viewing system is fully adjustable, allowing the operator to perform visual colour comparison under controlled instrument conditions. LMCR80F
The LMCR80F is designed for measurement of the colourity of liquid, gelatin, solid and powder samples. The catalogue specifically identifies applications involving grease, paint, plastic, jam, textile fabric, foodstuff, liquid chemicals and pharmaceuticals. LMCR80F
The catalogue also specifies a replaceable sample chamber liner and a replaceable light source, with two spare incandescent lamps included. LMCR80F
4. Key Features & Benefits
- Visual Colour Measurement – Measures colour using international colour scale units.
- Transmittance & Reflectance Modes – Supports two measurement modes.
- Visual Colour Matching – Designed for visual comparison and determination of material colour.
- 0.1 Colour Scale Unit Resolution – Provides fine colour-scale measurement resolution.
- Fully Adjustable Viewing System – Allows adjustment of the viewing arrangement.
- Incandescent Light Source – Uses an incandescent lamp with an illuminant approximating daylight.
- Replaceable Sample Chamber Liner – Facilitates replacement of the sample chamber liner.
- Replaceable Light Source – The light source can be replaced when required.
- Two Spare Incandescent Lamps – Two spare lamps are specified as part of the light-source arrangement.
- Multiple Sample Types – Suitable for liquid, gelatin, solid and powder samples.
- Long Path Length – Path length specified up to 180 mm.
- White Plate Reflectivity >80% – Specified diffuse reflectivity of the white plate.
- 1.9× Magnification – Magnifiers provide 1.9× amplification.
- Simple Structure – Designed for straightforward operation.
- International Colour Scale – Measurement principle is based on internationally accepted colour scale units. LMCR80F
5. Technical Specifications
| Specification | LMCR80F |
|---|---|
| Product Type | Visual Colorimeter |
| Model | LMCR80F |
| Make | LABMAN |
| HSN Code | 90275090 |
| Measuring Principle | Visual, in terms of International colour scale units |
| Measurement Modes | Transmittance, Reflectance |
| Red Measurement Range | 0.1–79.9 |
| Yellow Measurement Range | 0.1–79.9 |
| Blue Measurement Range | 0.1–49.9 |
| Neutral Measurement Range | 0.1–3.9 |
| Resolution | 0.1 colour scale unit |
| Viewing System | Fully adjustable |
| Light Source | Incandescent lamp |
| Illuminant | Approximates to daylight |
| Path Length | Up to 180 mm |
| Diffuse Reflectivity of White Plate | >80% |
| Magnifier Amplification | 1.9× |
| Cuvette Dimensions | 10 × 20 × 40 mm; 25.4 × 20 × 40 mm; 133.4 × 20 × 40 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Packing Dimensions (L × W × H) | 620 × 450 × 310 mm |
| Gross Weight | 10 kg |
| Sample Types | Liquid, gelatin, solid and powder |
The technical specifications are taken from the LMCR80F specification table on page 2 of the supplied catalogue. LMCR80F
6. Measurement Modes
Transmittance
The LMCR80F supports transmittance measurement, suitable for colour evaluation of samples where light transmission through the material is assessed.
Reflectance
The instrument also supports reflectance measurement, allowing visual colour assessment based on reflected light.
Both modes are explicitly specified for the LMCR80F. LMCR80F
7. Measurement Range
| Colour Scale | Measurement Range |
|---|---|
| Red | 0.1–79.9 |
| Yellow | 0.1–79.9 |
| Blue | 0.1–49.9 |
| Neutral | 0.1–3.9 |
| Resolution | 0.1 colour scale unit |
These are the colour-scale ranges stated in the manufacturer's LMCR80F specification table. LMCR80F
8. Sample Types
The LMCR80F is specified for colour measurement of:
- Liquid samples
- Gelatin
- Solid samples
- Powder samples
The catalogue additionally identifies colour measurement applications involving grease, paint, plastic, jam, textile fabric, foodstuff, liquid chemicals and pharmaceuticals. LMCR80F
9. Applications
Paint & Coatings
Colour measurement and matching of paint materials.
Plastics
Visual colour assessment of plastic materials.
Food & Food Products
The catalogue specifically identifies jam and foodstuff among the application materials.
Textile Materials
Suitable for visual colour measurement of textile fabric.
Chemicals
Designed for colour measurement of liquid chemicals.
Pharmaceuticals
The catalogue specifically lists pharmaceuticals among the materials for which the instrument is used. LMCR80F
Grease
The catalogue identifies grease among the materials used for colour measurement.
10. Suitable For
- Quality-control laboratories
- Paint and coatings laboratories
- Plastic testing laboratories
- Food-processing laboratories
- Textile laboratories
- Chemical laboratories
- Pharmaceutical laboratories
- Research laboratories
- Material colour inspection
- Visual colour matching applications
11. FAQs
1. What is the Labmart LMCR80F?
The LMCR80F is a Visual Colorimeter designed for visual colour matching and colour-scale measurement.
2. What measuring principle does it use?
It uses visual measurement in terms of international colour scale units.
3. What measurement modes are available?
The LMCR80F supports transmittance and reflectance.
4. What is the measurement range for Red?
0.1–79.9 Red.
5. What is the Yellow measurement range?
0.1–79.9 Yellow.
6. What is the Blue measurement range?
0.1–49.9 Blue.
7. What is the Neutral measurement range?
0.1–3.9 Neutral.
8. What is the resolution?
The resolution is 0.1 colour scale unit.
9. What type of light source is used?
The instrument uses an incandescent lamp.
10. Does the light source approximate daylight?
Yes. The specified illuminant approximates to daylight.
11. Is the viewing system adjustable?
Yes. The viewing system is fully adjustable.
12. What types of samples can be measured?
The catalogue specifies liquid, gelatin, solid and powder samples.
13. What materials can be tested?
The catalogue identifies grease, paint, plastic, jam, textile fabric, foodstuff, liquid chemicals and pharmaceuticals.
14. Can the sample chamber liner be replaced?
Yes. A replaceable sample chamber liner is one of the salient features.
15. Is the light source replaceable?
Yes. The light source is replaceable, and the catalogue specifies two spare incandescent lamps.
16. What is the maximum path length?
The specified path length is up to 180 mm.
17. What is the white plate reflectivity?
The specified diffuse reflectivity of the white plate is >80%.
18. What is the magnifier amplification?
The magnifiers provide 1.9× amplification.
19. What power supply is required?
AC 220 V, 50/60 Hz.
20. What are the packing dimensions?
620 × 450 × 310 mm (L × W × H).
21. What is the gross weight?
The specified gross weight is 10 kg.
22. What accessories are supplied?
The standard accessories include the main instrument, cuvette lamp, lens tube, power cable, instruction manual and test certificate.
- Regular price
- Rs.121,999.00
- Sale price
- Rs.80,999.00
Sale
GST Invoice included
(Save 18% on business purchases)
Need Quote ?
Get Bulk Order Quotation for your lab or Tender Quotation at special discounts !
Contact our support team at support@labmart.in to get the best quote for your bulk order requirement.
Sales Support - +918920746300
Technical Support- +919667893959
Kindly allow us a time of 2-3 days to properly match all the inquired specs, we will also provide authorization(s) to dealers for particular tenders (on tender basis)

-
Free Shipping
Orders above Rs. 1000.
-
On Time Delivery
Within 7 days.
-
Money Back Guarantee
14 day Return*
-
Service Support
Online Installation Support.
Product Description
The Labmart LMCR80F Visual Colorimeter is a laboratory visual colour measuring instrument designed for visual colour matching and measurement using international colour scale units. It supports transmittance and reflectance modes and provides a measurement range of 0.1–79.9 Red, 0.1–79.9 Yellow, 0.1–49.9 Blue and 0.1–3.9 Neutral, with 0.1 colour scale unit resolution.
The LMCR80F features a fully adjustable viewing system, incandescent light source approximating daylight, replaceable sample chamber liner, replaceable light source with two spare incandescent lamps and interchangeable cuvette configurations. It is designed for colour measurement of liquids, gelatin, solids and powders and is used across applications including paints, plastics, textiles, foodstuff, liquid chemicals and pharmaceuticals. LMCR80F
3. Detailed Product Description
Product Overview
The LMCR80F Visual Colorimeter is a visual colour measurement instrument based on internationally acknowledged colour scale units. It is designed to determine material colour through visual colour matching.
The instrument supports both transmittance and reflectance modes and uses an incandescent lamp whose illuminant approximates daylight. The viewing system is fully adjustable, allowing the operator to perform visual colour comparison under controlled instrument conditions. LMCR80F
The LMCR80F is designed for measurement of the colourity of liquid, gelatin, solid and powder samples. The catalogue specifically identifies applications involving grease, paint, plastic, jam, textile fabric, foodstuff, liquid chemicals and pharmaceuticals. LMCR80F
The catalogue also specifies a replaceable sample chamber liner and a replaceable light source, with two spare incandescent lamps included. LMCR80F
4. Key Features & Benefits
- Visual Colour Measurement – Measures colour using international colour scale units.
- Transmittance & Reflectance Modes – Supports two measurement modes.
- Visual Colour Matching – Designed for visual comparison and determination of material colour.
- 0.1 Colour Scale Unit Resolution – Provides fine colour-scale measurement resolution.
- Fully Adjustable Viewing System – Allows adjustment of the viewing arrangement.
- Incandescent Light Source – Uses an incandescent lamp with an illuminant approximating daylight.
- Replaceable Sample Chamber Liner – Facilitates replacement of the sample chamber liner.
- Replaceable Light Source – The light source can be replaced when required.
- Two Spare Incandescent Lamps – Two spare lamps are specified as part of the light-source arrangement.
- Multiple Sample Types – Suitable for liquid, gelatin, solid and powder samples.
- Long Path Length – Path length specified up to 180 mm.
- White Plate Reflectivity >80% – Specified diffuse reflectivity of the white plate.
- 1.9× Magnification – Magnifiers provide 1.9× amplification.
- Simple Structure – Designed for straightforward operation.
- International Colour Scale – Measurement principle is based on internationally accepted colour scale units. LMCR80F
5. Technical Specifications
| Specification | LMCR80F |
|---|---|
| Product Type | Visual Colorimeter |
| Model | LMCR80F |
| Make | LABMAN |
| HSN Code | 90275090 |
| Measuring Principle | Visual, in terms of International colour scale units |
| Measurement Modes | Transmittance, Reflectance |
| Red Measurement Range | 0.1–79.9 |
| Yellow Measurement Range | 0.1–79.9 |
| Blue Measurement Range | 0.1–49.9 |
| Neutral Measurement Range | 0.1–3.9 |
| Resolution | 0.1 colour scale unit |
| Viewing System | Fully adjustable |
| Light Source | Incandescent lamp |
| Illuminant | Approximates to daylight |
| Path Length | Up to 180 mm |
| Diffuse Reflectivity of White Plate | >80% |
| Magnifier Amplification | 1.9× |
| Cuvette Dimensions | 10 × 20 × 40 mm; 25.4 × 20 × 40 mm; 133.4 × 20 × 40 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Packing Dimensions (L × W × H) | 620 × 450 × 310 mm |
| Gross Weight | 10 kg |
| Sample Types | Liquid, gelatin, solid and powder |
The technical specifications are taken from the LMCR80F specification table on page 2 of the supplied catalogue. LMCR80F
6. Measurement Modes
Transmittance
The LMCR80F supports transmittance measurement, suitable for colour evaluation of samples where light transmission through the material is assessed.
Reflectance
The instrument also supports reflectance measurement, allowing visual colour assessment based on reflected light.
Both modes are explicitly specified for the LMCR80F. LMCR80F
7. Measurement Range
| Colour Scale | Measurement Range |
|---|---|
| Red | 0.1–79.9 |
| Yellow | 0.1–79.9 |
| Blue | 0.1–49.9 |
| Neutral | 0.1–3.9 |
| Resolution | 0.1 colour scale unit |
These are the colour-scale ranges stated in the manufacturer's LMCR80F specification table. LMCR80F
8. Sample Types
The LMCR80F is specified for colour measurement of:
- Liquid samples
- Gelatin
- Solid samples
- Powder samples
The catalogue additionally identifies colour measurement applications involving grease, paint, plastic, jam, textile fabric, foodstuff, liquid chemicals and pharmaceuticals. LMCR80F
9. Applications
Paint & Coatings
Colour measurement and matching of paint materials.
Plastics
Visual colour assessment of plastic materials.
Food & Food Products
The catalogue specifically identifies jam and foodstuff among the application materials.
Textile Materials
Suitable for visual colour measurement of textile fabric.
Chemicals
Designed for colour measurement of liquid chemicals.
Pharmaceuticals
The catalogue specifically lists pharmaceuticals among the materials for which the instrument is used. LMCR80F
Grease
The catalogue identifies grease among the materials used for colour measurement.
10. Suitable For
- Quality-control laboratories
- Paint and coatings laboratories
- Plastic testing laboratories
- Food-processing laboratories
- Textile laboratories
- Chemical laboratories
- Pharmaceutical laboratories
- Research laboratories
- Material colour inspection
- Visual colour matching applications
11. FAQs
1. What is the Labmart LMCR80F?
The LMCR80F is a Visual Colorimeter designed for visual colour matching and colour-scale measurement.
2. What measuring principle does it use?
It uses visual measurement in terms of international colour scale units.
3. What measurement modes are available?
The LMCR80F supports transmittance and reflectance.
4. What is the measurement range for Red?
0.1–79.9 Red.
5. What is the Yellow measurement range?
0.1–79.9 Yellow.
6. What is the Blue measurement range?
0.1–49.9 Blue.
7. What is the Neutral measurement range?
0.1–3.9 Neutral.
8. What is the resolution?
The resolution is 0.1 colour scale unit.
9. What type of light source is used?
The instrument uses an incandescent lamp.
10. Does the light source approximate daylight?
Yes. The specified illuminant approximates to daylight.
11. Is the viewing system adjustable?
Yes. The viewing system is fully adjustable.
12. What types of samples can be measured?
The catalogue specifies liquid, gelatin, solid and powder samples.
13. What materials can be tested?
The catalogue identifies grease, paint, plastic, jam, textile fabric, foodstuff, liquid chemicals and pharmaceuticals.
14. Can the sample chamber liner be replaced?
Yes. A replaceable sample chamber liner is one of the salient features.
15. Is the light source replaceable?
Yes. The light source is replaceable, and the catalogue specifies two spare incandescent lamps.
16. What is the maximum path length?
The specified path length is up to 180 mm.
17. What is the white plate reflectivity?
The specified diffuse reflectivity of the white plate is >80%.
18. What is the magnifier amplification?
The magnifiers provide 1.9× amplification.
19. What power supply is required?
AC 220 V, 50/60 Hz.
20. What are the packing dimensions?
620 × 450 × 310 mm (L × W × H).
21. What is the gross weight?
The specified gross weight is 10 kg.
22. What accessories are supplied?
The standard accessories include the main instrument, cuvette lamp, lens tube, power cable, instruction manual and test certificate.
Similar Products
-
Sale
Vendor: Systonic
Turbidity-Nephelometer
Sale price Rs.8,999.00Regular price Rs.12,000.00 -
Sale
Vendor: Systonic
Digital Friability Test Apparatus
Sale price From Rs.16,000.00Regular price Rs.20,000.00 -
Sale
Vendor: Systonic
Auto PH Meter
Sale price Rs.7,000.00Regular price Rs.10,000.00 -
Sale
Vendor: Quantis
Benchtop PH Meter I 0-14 PH I 3point calibration I ATC I Memory Storage Function
Sale price Rs.9,999.00Regular price Rs.16,000.00