{"product_id":"nano-spectrophotometer-i-micro-volume-spectrophotometer","title":"Nano Spectrophotometer I Micro Volume Spectrophotometer I In Built Thermal Printer I FREE ONSITE INSTALLATION","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpectrix UV-N1 Microvolume Spectrophotometer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance laboratory instrument designed for rapid and accurate quantification of nucleic acids, proteins, and other biological samples using extremely low sample volumes of just\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5–2 µL\u003c\/strong\u003e. Featuring a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e190–850 nm full-spectrum wavelength range\u003c\/strong\u003e, four optical path lengths, integrated fluorescence detection, OD600 measurement, UV-Vis analysis, and a built-in thermal printer, it is ideal for molecular biology, genomics, biotechnology, pharmaceutical, food, and research laboratories.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe intuitive Android-based touchscreen interface enables quick measurements, while advanced fluorescence detection allows highly sensitive DNA, RNA, and protein quantification without requiring cuvettes for microvolume analysis.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFull wavelength scanning from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e190–850 nm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRequires only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5–2 µL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esample volume\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour automatic optical path lengths for low and high concentration samples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-accuracy nucleic acid and protein quantification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUV-Vis absorbance measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated fluorescence detection for DNA, RNA and proteins\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUV-N1 measurement for bacterial cell density analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eColorimetric assay support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKinetic measurement mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirect sample measurement without cuvettes in microvolume mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuartz measurement pedestal for maximum accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eXenon flash lamp for long service life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUV-enhanced CMOS detector for high sensitivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e7-inch capacitive touch screen\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAndroid operating system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in thermal printer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUSB connectivity for data export\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast testing in less than 6 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable and repeatable measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for molecular biology, biotechnology, pharmaceutical, clinical and research laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrix\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUV-N1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e190–850 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Scan\u003c\/td\u003e\n\u003ctd\u003e190–850 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e0.5–2 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Paths\u003c\/td\u003e\n\u003ctd\u003e0.02 mm, 0.05 mm, 0.2 mm, 1.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNucleic Acid Detection Range\u003c\/td\u003e\n\u003ctd\u003e2–27,500 ng\/µL (dsDNA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eXenon Flash Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eUV-Enhanced CMOS Line Array Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Detectors\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.002 Abs (0.2 mm), ±1% at 7.332 Abs (260 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd\u003e0.02–3.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOD600 Range\u003c\/td\u003e\n\u003ctd\u003e0–6.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOD600 Stability\u003c\/td\u003e\n\u003ctd\u003e≤0.5% (0.3 Abs), ≤2% (3.4 Abs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOD600 Repeatability\u003c\/td\u003e\n\u003ctd\u003e≤0.5% (0.3 Abs), ≤2% (3.4 Abs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluorescence Linearity\u003c\/td\u003e\n\u003ctd\u003eR² \u0026gt; 0.995\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluorescence Repeatability\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluorescence Sensitivity\u003c\/td\u003e\n\u003ctd\u003edsDNA 0.5 pg\/µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Platform\u003c\/td\u003e\n\u003ctd\u003eQuartz Fiber \u0026amp; Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Android OS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eUSB Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter\u003c\/td\u003e\n\u003ctd\u003eIntegrated Thermal Printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 220V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e555 × 410 × 330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"relative h-0 self-end select-none\"\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\"\u003e\u003cbutton class=\"hover:bg-token-bg-tertiary text-token-text-secondary relative z-10 my-1 rounded-sm p-1 transition-opacity group-[:not(:hover):not(:focus-within)]:pointer-events-none group-[:not(:hover):not(:focus-within)]:opacity-0\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" class=\"icon\"\u003e\u003cuse href=\"\/cdn\/assets\/sprites-core-9c95ad62.svg#ce3544\" fill=\"currentColor\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eStandard Accessories\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSpectrix MSOD6 Main Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuartz Cuvettes (2 Nos.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSample Holder Box\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Printer Paper Roll\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest Certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFrequently Asked Questions (FAQs)\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3\u003e1. What is the minimum sample volume required?\u003c\/h3\u003e\n\u003cp\u003eThe Spectrix MSOD6 requires only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5–2 µL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof sample for accurate measurement.\u003c\/p\u003e\n\u003ch3\u003e2. What types of samples can be analyzed?\u003c\/h3\u003e\n\u003cp\u003eIt can analyze DNA, RNA, proteins, bacterial cultures (OD600), colorimetric assays, and UV-Vis absorbance samples.\u003c\/p\u003e\n\u003ch3\u003e3. Does the instrument support fluorescence measurements?\u003c\/h3\u003e\n\u003cp\u003eYes. It features integrated fluorescence detection for sensitive quantification of DNA, RNA, and proteins.\u003c\/p\u003e\n\u003ch3\u003e4. What is the wavelength range?\u003c\/h3\u003e\n\u003cp\u003eThe instrument covers a full wavelength range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e190–850 nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e5. Can it measure bacterial cell concentration?\u003c\/h3\u003e\n\u003cp\u003eYes. It includes an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOD600 measurement mode\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor bacterial growth and cell density analysis.\u003c\/p\u003e\n\u003ch3\u003e6. Does it require cuvettes for every measurement?\u003c\/h3\u003e\n\u003cp\u003eNo. Microvolume measurements are performed directly on the quartz pedestal without cuvettes. Cuvette mode is also available when required.\u003c\/p\u003e\n\u003ch3\u003e7. How long does one measurement take?\u003c\/h3\u003e\n\u003cp\u003eTypical measurement time is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eless than 6 seconds\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e8. What detector technology is used?\u003c\/h3\u003e\n\u003cp\u003eThe system uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUV-enhanced CMOS Line Array Sensor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith a Xenon flash lamp for stable and accurate performance.\u003c\/p\u003e\n\u003ch3\u003e9. Does it include a printer?\u003c\/h3\u003e\n\u003cp\u003eYes. The Spectrix MSOD6 comes with a built-in thermal printer for instant result printing.\u003c\/p\u003e\n\u003ch3\u003e10. Which laboratories commonly use this instrument?\u003c\/h3\u003e\n\u003cp\u003eIt is widely used in molecular biology labs, genomics, biotechnology, pharmaceutical R\u0026amp;D, academic institutions, clinical laboratories, food testing labs, and environmental research facilities.\u003c\/p\u003e\n\u003ch3\u003e11. Can the instrument export data?\u003c\/h3\u003e\n\u003cp\u003eYes. Results can be exported via the integrated USB interface.\u003c\/p\u003e\n\u003ch3\u003e12. Is the instrument suitable for high-concentration DNA samples?\u003c\/h3\u003e\n\u003cp\u003eYes. Its four automatic optical path lengths enable accurate measurement across both low- and high-concentration samples.\u003c\/p\u003e","brand":"Spectrix","offers":[{"title":"Default Title","offer_id":53394089115945,"sku":"UV-N1","price":299999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/nano-drop-spectrophotometer.webp?v=1785495429","url":"https:\/\/www.labmart.in\/products\/nano-spectrophotometer-i-micro-volume-spectrophotometer","provider":"Labmart.in","version":"1.0","type":"link"}