{"product_id":"lmdv111-digital-viscometer-small-sample-adaptor","title":"Digital Viscometer with Small Sample Adaptor LMDV111","description":"\u003cp dir=\"auto\" data-start=\"134\" data-end=\"546\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"138\" data-end=\"194\"\u003eLMDV111 Digital Viscometer with Small Sample Adaptor\u003c\/strong\u003e is a digital direct-reading rotational viscometer designed for measuring the \u003cstrong data-start=\"272\" data-end=\"363\"\u003eabsolute viscosity of Newtonian liquids and apparent viscosity of non-Newtonian liquids\u003c\/strong\u003e. It combines a wide \u003cstrong data-start=\"384\" data-end=\"406\"\u003e12–6,000,000 mPa·s\u003c\/strong\u003e viscosity range with a dedicated small sample adaptor requiring approximately \u003cstrong data-start=\"485\" data-end=\"507\"\u003e10–20 mL of sample\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"509\" data-content-reference-end=\"539\"\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"583\" data-end=\"602\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"604\" data-end=\"815\"\u003eThe \u003cstrong data-start=\"608\" data-end=\"671\"\u003eLABMAN LMDV111 Digital Viscometer with Small Sample Adaptor\u003c\/strong\u003e is a digital direct-reading rotational viscometer specifically configured for viscosity measurement where a smaller sample volume is desirable.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"817\" data-end=\"1094\"\u003eThe LMDV111 provides a measuring range of \u003cstrong data-start=\"859\" data-end=\"881\"\u003e12–6,000,000 mPa·s\u003c\/strong\u003e, selectable stepless speed from \u003cstrong data-start=\"914\" data-end=\"929\"\u003e0.1 to 99.9\u003c\/strong\u003e, and \u003cstrong data-start=\"935\" data-end=\"950\"\u003e1000 speeds\u003c\/strong\u003e. It provides direct viscosity and temperature display through an LCD and includes temperature monitoring. \u003cspan class=\"contents\" data-content-reference-start=\"1050\" data-content-reference-end=\"1081\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1096\" data-end=\"1559\"\u003eThe supplied \u003cstrong data-start=\"1109\" data-end=\"1157\"\u003eSmall Sample Adaptor is a standard accessory\u003c\/strong\u003e. The catalogue describes it as consisting of a coupling nut, extension link, spindle set \u003cstrong data-start=\"1247\" data-end=\"1272\"\u003e#21, #27, #28 and #29\u003c\/strong\u003e, sample chamber and adjustable base. The catalogue specifies approximately \u003cstrong data-start=\"1348\" data-end=\"1357\"\u003e15 mL\u003c\/strong\u003e sample requirement in its product description, while the specification table gives a minimum sample range of \u003cstrong data-start=\"1467\" data-end=\"1482\"\u003e10 mL–20 mL\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"1471\" data-content-reference-end=\"1501\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\" data-content-reference-start=\"1502\" data-content-reference-end=\"1532\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1561\" data-end=\"1741\"\u003eThe sample chamber fits into a \u003cstrong data-start=\"1592\" data-end=\"1608\"\u003ewater jacket\u003c\/strong\u003e, and sample temperature can be controlled using an optional \u003cstrong data-start=\"1669\" data-end=\"1702\"\u003eRefrigerated Circulating Bath\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"1677\" data-content-reference-end=\"1707\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" dir=\"auto\" data-start=\"1743\" data-end=\"1758\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1760\" data-end=\"2403\"\u003e\n\u003cli data-section-id=\"1hoqbua\" data-start=\"1760\" data-end=\"1806\"\u003eDigital direct-reading rotational viscometer\u003c\/li\u003e\n\u003cli data-section-id=\"zb53xj\" data-start=\"1807\" data-end=\"1850\"\u003eSmall Sample Adaptor supplied as standard\u003c\/li\u003e\n\u003cli data-section-id=\"c5728k\" data-start=\"1851\" data-end=\"1891\"\u003e\n\u003cstrong data-start=\"1853\" data-end=\"1875\"\u003e12–6,000,000 mPa·s\u003c\/strong\u003e measuring range\u003c\/li\u003e\n\u003cli data-section-id=\"1cacam3\" data-start=\"1892\" data-end=\"1918\"\u003e\n\u003cstrong data-start=\"1894\" data-end=\"1906\"\u003e0.1–99.9\u003c\/strong\u003e speed range\u003c\/li\u003e\n\u003cli data-section-id=\"gm5o7x\" data-start=\"1919\" data-end=\"1936\"\u003e\u003cstrong data-start=\"1921\" data-end=\"1936\"\u003e1000 speeds\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"8uxu6u\" data-start=\"1937\" data-end=\"1964\"\u003eSelectable stepless speed\u003c\/li\u003e\n\u003cli data-section-id=\"1rnbh6\" data-start=\"1965\" data-end=\"1986\"\u003eAuto Range function\u003c\/li\u003e\n\u003cli data-section-id=\"1bj78q7\" data-start=\"1987\" data-end=\"2029\"\u003eDirect viscosity and temperature display\u003c\/li\u003e\n\u003cli data-section-id=\"1vciy41\" data-start=\"2030\" data-end=\"2070\"\u003eBig ultra-bright backlight LCD display\u003c\/li\u003e\n\u003cli data-section-id=\"186zts8\" data-start=\"2071\" data-end=\"2095\"\u003eTemperature monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1cute55\" data-start=\"2096\" data-end=\"2168\"\u003eEight-spindle configuration: \u003cstrong data-start=\"2127\" data-end=\"2168\"\u003eL1, L2, L3, L4, #21, #27, #28 and #29\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15tuf4f\" data-start=\"2169\" data-end=\"2202\"\u003e\n\u003cstrong data-start=\"2171\" data-end=\"2181\"\u003e±1% FS\u003c\/strong\u003e measurement accuracy\u003c\/li\u003e\n\u003cli data-section-id=\"13ndg3b\" data-start=\"2203\" data-end=\"2231\"\u003e\n\u003cstrong data-start=\"2205\" data-end=\"2217\"\u003e±0.5% FS\u003c\/strong\u003e repeatability\u003c\/li\u003e\n\u003cli data-section-id=\"1w7zluk\" data-start=\"2232\" data-end=\"2250\"\u003eRS232C interface\u003c\/li\u003e\n\u003cli data-section-id=\"1xchhxk\" data-start=\"2251\" data-end=\"2320\"\u003eSmall sample testing with approximately 10–20 mL sample requirement\u003c\/li\u003e\n\u003cli data-section-id=\"1vjjzq\" data-start=\"2321\" data-end=\"2403\"\u003eSample temperature control possible using optional refrigerated circulating bath\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2405\" data-end=\"2434\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2436\" data-end=\"3289\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2436\" data-end=\"2463\"\u003e\n\u003ctr data-start=\"2436\" data-end=\"2463\"\u003e\n\u003cth data-start=\"2436\" data-end=\"2452\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2452\" data-end=\"2463\" data-col-size=\"md\" class=\"last:pe-10\"\u003eLMDV111\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2474\" data-end=\"3289\"\u003e\n\u003ctr data-start=\"2474\" data-end=\"2532\"\u003e\n\u003ctd data-start=\"2474\" data-end=\"2484\" data-col-size=\"sm\"\u003eProduct\u003c\/td\u003e\n\u003ctd data-start=\"2484\" data-end=\"2532\" data-col-size=\"md\"\u003eDigital Viscometer with Small Sample Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2533\" data-end=\"2556\"\u003e\n\u003ctd data-start=\"2533\" data-end=\"2541\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2541\" data-end=\"2556\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2543\" data-end=\"2554\"\u003eLMDV111\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2557\" data-end=\"2578\"\u003e\n\u003ctd data-start=\"2557\" data-end=\"2564\" data-col-size=\"sm\"\u003eMake\u003c\/td\u003e\n\u003ctd data-start=\"2564\" data-end=\"2578\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2566\" data-end=\"2576\"\u003eLABMAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2579\" data-end=\"2606\"\u003e\n\u003ctd data-start=\"2579\" data-end=\"2590\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"2590\" data-end=\"2606\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2592\" data-end=\"2604\"\u003e90278910\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2607\" data-end=\"2651\"\u003e\n\u003ctd data-start=\"2607\" data-end=\"2625\" data-col-size=\"sm\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd data-start=\"2625\" data-end=\"2651\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2627\" data-end=\"2649\"\u003e12–6,000,000 mPa·s\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2652\" data-end=\"2676\"\u003e\n\u003ctd data-start=\"2652\" data-end=\"2660\" data-col-size=\"sm\"\u003eSpeed\u003c\/td\u003e\n\u003ctd data-start=\"2660\" data-end=\"2676\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2662\" data-end=\"2674\"\u003e0.1–99.9\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2677\" data-end=\"2708\"\u003e\n\u003ctd data-start=\"2677\" data-end=\"2696\" data-col-size=\"sm\"\u003eNumber of Speeds\u003c\/td\u003e\n\u003ctd data-start=\"2696\" data-end=\"2708\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2698\" data-end=\"2706\"\u003e1000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2709\" data-end=\"2768\"\u003e\n\u003ctd data-start=\"2709\" data-end=\"2722\" data-col-size=\"sm\"\u003eSpeed Type\u003c\/td\u003e\n\u003ctd data-start=\"2722\" data-end=\"2768\" data-col-size=\"md\"\u003eSelectable Stepless Speed (nonpolar shift)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2769\" data-end=\"2808\"\u003e\n\u003ctd data-start=\"2769\" data-end=\"2799\" data-col-size=\"sm\"\u003eNumber of Standard Spindles\u003c\/td\u003e\n\u003ctd data-start=\"2799\" data-end=\"2808\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2801\" data-end=\"2806\"\u003e8\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2809\" data-end=\"2871\"\u003e\n\u003ctd data-start=\"2809\" data-end=\"2829\" data-col-size=\"sm\"\u003eStandard Spindles\u003c\/td\u003e\n\u003ctd data-start=\"2829\" data-end=\"2871\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2831\" data-end=\"2869\"\u003eL1, L2, L3, L4, #21, #27, #28, #29\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2872\" data-end=\"2906\"\u003e\n\u003ctd data-start=\"2872\" data-end=\"2895\" data-col-size=\"sm\"\u003eSmall Sample Adaptor\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2895\" data-end=\"2906\"\u003e\u003cstrong data-start=\"2897\" data-end=\"2904\"\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2907\" data-end=\"2940\"\u003e\n\u003ctd data-start=\"2907\" data-end=\"2924\" data-col-size=\"sm\"\u003eMinimum Sample\u003c\/td\u003e\n\u003ctd data-start=\"2924\" data-end=\"2940\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2938\"\u003e10–20 mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2941\" data-end=\"2958\"\u003e\n\u003ctd data-start=\"2941\" data-end=\"2951\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2951\" data-end=\"2958\" data-col-size=\"md\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2959\" data-end=\"3004\"\u003e\n\u003ctd data-start=\"2959\" data-end=\"2994\" data-col-size=\"sm\"\u003eShear Rate \/ Shear Force Display\u003c\/td\u003e\n\u003ctd data-start=\"2994\" data-end=\"3004\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2996\" data-end=\"3002\"\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3005\" data-end=\"3041\"\u003e\n\u003ctd data-start=\"3005\" data-end=\"3030\" data-col-size=\"sm\"\u003eTemperature Monitoring\u003c\/td\u003e\n\u003ctd data-start=\"3030\" data-end=\"3041\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3032\" data-end=\"3039\"\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3042\" data-end=\"3081\"\u003e\n\u003ctd data-start=\"3042\" data-end=\"3065\" data-col-size=\"sm\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3065\" data-end=\"3081\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3067\" data-end=\"3079\"\u003e±1% (FS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3082\" data-end=\"3116\"\u003e\n\u003ctd data-start=\"3082\" data-end=\"3098\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"3098\" data-end=\"3116\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3100\" data-end=\"3114\"\u003e±0.5% (FS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3117\" data-end=\"3150\"\u003e\n\u003ctd data-start=\"3117\" data-end=\"3126\" data-col-size=\"sm\"\u003eOutput\u003c\/td\u003e\n\u003ctd data-start=\"3126\" data-end=\"3150\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3128\" data-end=\"3148\"\u003eRS232C Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3151\" data-end=\"3201\"\u003e\n\u003ctd data-start=\"3151\" data-end=\"3166\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3166\" data-end=\"3201\" data-col-size=\"md\"\u003eAdaptor, using AC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3202\" data-end=\"3260\"\u003e\n\u003ctd data-start=\"3202\" data-end=\"3234\" data-col-size=\"sm\"\u003ePacking Dimension (L × W × H)\u003c\/td\u003e\n\u003ctd data-start=\"3234\" data-end=\"3260\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3236\" data-end=\"3258\"\u003e420 × 375 × 550 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3261\" data-end=\"3289\"\u003e\n\u003ctd data-start=\"3261\" data-end=\"3276\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3276\" data-end=\"3289\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3278\" data-end=\"3287\"\u003e15 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"3291\" data-end=\"3442\"\u003eThe specifications above are taken specifically from the \u003cstrong data-start=\"3348\" data-end=\"3366\"\u003eLMDV111 column\u003c\/strong\u003e of the catalogue specification table. \u003cspan class=\"contents\" data-content-reference-start=\"3371\" data-content-reference-end=\"3402\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vy72vd\" dir=\"auto\" data-start=\"3444\" data-end=\"3474\"\u003eSmall Sample Spindle Range\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3476\" data-end=\"3641\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3476\" data-end=\"3503\"\u003e\n\u003ctr data-start=\"3476\" data-end=\"3503\"\u003e\n\u003cth data-start=\"3476\" data-end=\"3486\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpindle\u003c\/th\u003e\n\u003cth data-start=\"3486\" data-end=\"3503\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eLMDV111 Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3515\" data-end=\"3641\"\u003e\n\u003ctr data-start=\"3515\" data-end=\"3545\"\u003e\n\u003ctd data-start=\"3515\" data-end=\"3525\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3517\" data-end=\"3524\"\u003e#21\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3525\" data-end=\"3545\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3527\" data-end=\"3543\"\u003e10–50K mPa·s\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3546\" data-end=\"3577\"\u003e\n\u003ctd data-start=\"3546\" data-end=\"3556\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3548\" data-end=\"3555\"\u003e#27\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3556\" data-end=\"3577\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3558\" data-end=\"3575\"\u003e50–250K mPa·s\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3578\" data-end=\"3610\"\u003e\n\u003ctd data-start=\"3578\" data-end=\"3588\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3580\" data-end=\"3587\"\u003e#28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3588\" data-end=\"3610\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3590\" data-end=\"3608\"\u003e100–500K mPa·s\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3611\" data-end=\"3641\"\u003e\n\u003ctd data-start=\"3611\" data-end=\"3621\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3613\" data-end=\"3620\"\u003e#29\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3621\" data-end=\"3641\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3623\" data-end=\"3639\"\u003e200–1M mPa·s\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"3643\" data-end=\"3778\"\u003eThe catalogue's spindle range table identifies these ranges for the LMDV111 Small Sample Adaptor. \u003cspan class=\"contents\" data-content-reference-start=\"3701\" data-content-reference-end=\"3731\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3780\" data-end=\"3797\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3799\" data-end=\"3843\"\u003eThe catalogue specifies the LMDV series for:\u003c\/p\u003e\n\u003cul data-start=\"3845\" data-end=\"4120\"\u003e\n\u003cli data-section-id=\"1nuj5n\" data-start=\"3845\" data-end=\"3898\"\u003eAbsolute viscosity measurement of Newtonian liquids\u003c\/li\u003e\n\u003cli data-section-id=\"1ogj8eb\" data-start=\"3899\" data-end=\"3956\"\u003eApparent viscosity measurement of non-Newtonian liquids\u003c\/li\u003e\n\u003cli data-section-id=\"kjeygm\" data-start=\"3957\" data-end=\"3999\"\u003eDigital rotational viscosity measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1b0rzlf\" data-start=\"4000\" data-end=\"4032\"\u003eSmall-volume viscosity testing\u003c\/li\u003e\n\u003cli data-section-id=\"1ca2kk6\" data-start=\"4033\" data-end=\"4067\"\u003eLaboratory viscosity measurement\u003c\/li\u003e\n\u003cli data-section-id=\"11wc53\" data-start=\"4068\" data-end=\"4120\"\u003eViscosity testing where sample quantity is limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"4122\" data-end=\"4298\"\u003eThe catalogue does not specify individual industries or materials for the LMDV111, so specific industry applications are not claimed here. \u003cspan class=\"contents\" data-content-reference-start=\"4214\" data-content-reference-end=\"4244\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"4300\" data-end=\"4317\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cul data-start=\"4319\" data-end=\"4630\"\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"4319\" data-end=\"4342\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"9f68h1\" data-start=\"4343\" data-end=\"4368\"\u003eAnalytical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"4369\" data-end=\"4399\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1qoxw4d\" data-start=\"4400\" data-end=\"4418\"\u003eR\u0026amp;D laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ot8fwn\" data-start=\"4419\" data-end=\"4469\"\u003eLaboratories working with limited sample volumes\u003c\/li\u003e\n\u003cli data-section-id=\"1o6shbe\" data-start=\"4470\" data-end=\"4506\"\u003eNewtonian liquid viscosity testing\u003c\/li\u003e\n\u003cli data-section-id=\"1c2ktmw\" data-start=\"4507\" data-end=\"4547\"\u003eNon-Newtonian liquid viscosity testing\u003c\/li\u003e\n\u003cli data-section-id=\"uswztz\" data-start=\"4548\" data-end=\"4630\"\u003eLaboratories requiring temperature-controlled small-sample viscosity measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"7111\" data-end=\"7121\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"i9oeh9\" dir=\"auto\" data-start=\"7123\" data-end=\"7150\"\u003e1. What is the LMDV111?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7152\" data-end=\"7279\"\u003eThe LMDV111 is a \u003cstrong data-start=\"7169\" data-end=\"7217\"\u003eDigital Viscometer with Small Sample Adaptor\u003c\/strong\u003e designed for direct-reading rotational viscosity measurement.\u003c\/p\u003e\n\u003ch3 data-section-id=\"fived8\" dir=\"auto\" data-start=\"7281\" data-end=\"7331\"\u003e2. What is the measuring range of the LMDV111?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7333\" data-end=\"7379\"\u003eThe specified range is \u003cstrong data-start=\"7356\" data-end=\"7378\"\u003e12–6,000,000 mPa·s\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"123b2wr\" dir=\"auto\" data-start=\"7381\" data-end=\"7436\"\u003e3. Does the LMDV111 include a Small Sample Adaptor?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7438\" data-end=\"7509\"\u003eYes. The \u003cstrong data-start=\"7447\" data-end=\"7508\"\u003eSmall Sample Adaptor is specified as a standard accessory\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"z775n9\" dir=\"auto\" data-start=\"7511\" data-end=\"7546\"\u003e4. How much sample is required?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7548\" data-end=\"7794\"\u003eThe specification table states a minimum sample requirement of \u003cstrong data-start=\"7611\" data-end=\"7623\"\u003e10–20 mL\u003c\/strong\u003e. The descriptive section of the catalogue states that approximately \u003cstrong data-start=\"7692\" data-end=\"7701\"\u003e15 mL\u003c\/strong\u003e is needed for testing with the Small Sample Adaptor. \u003cspan class=\"contents\" data-content-reference-start=\"7687\" data-content-reference-end=\"7717\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1moktn2\" dir=\"auto\" data-start=\"7796\" data-end=\"7861\"\u003e5. Which spindles are supplied with the Small Sample Adaptor?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7863\" data-end=\"7927\"\u003eThe Small Sample Adaptor uses spindle \u003cstrong data-start=\"7901\" data-end=\"7926\"\u003e#21, #27, #28 and #29\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2qscrp\" dir=\"auto\" data-start=\"7929\" data-end=\"7985\"\u003e6. What are the Small Sample Adaptor spindle ranges?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7987\" data-end=\"8024\"\u003eFor LMDV111, the catalogue specifies:\u003c\/p\u003e\n\u003cul data-start=\"8026\" data-end=\"8164\"\u003e\n\u003cli data-section-id=\"11httli\" data-start=\"8026\" data-end=\"8049\"\u003e#21: \u003cstrong data-start=\"8033\" data-end=\"8049\"\u003e10–50K mPa·s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10ol42u\" data-start=\"8050\" data-end=\"8074\"\u003e#27: \u003cstrong data-start=\"8057\" data-end=\"8074\"\u003e50–250K mPa·s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jlz00v\" data-start=\"8075\" data-end=\"8100\"\u003e#28: \u003cstrong data-start=\"8082\" data-end=\"8100\"\u003e100–500K mPa·s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g4ys5e\" data-start=\"8101\" data-end=\"8164\"\u003e#29: \u003cstrong data-start=\"8108\" data-end=\"8124\"\u003e200–1M mPa·s\u003c\/strong\u003e \u003cspan class=\"contents\" data-content-reference-start=\"8048\" data-content-reference-end=\"8078\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"941n18\" dir=\"auto\" data-start=\"8166\" data-end=\"8220\"\u003e7. How many total standard spindles are specified?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8222\" data-end=\"8340\"\u003eThe catalogue specifies \u003cstrong data-start=\"8246\" data-end=\"8299\"\u003e8 spindles: L1, L2, L3, L4, #21, #27, #28 and #29\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"8215\" data-content-reference-end=\"8245\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1quhcxq\" dir=\"auto\" data-start=\"8342\" data-end=\"8373\"\u003e8. What is the speed range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8375\" data-end=\"8442\"\u003eThe LMDV111 has a speed range of \u003cstrong data-start=\"8408\" data-end=\"8420\"\u003e0.1–99.9\u003c\/strong\u003e with \u003cstrong data-start=\"8426\" data-end=\"8441\"\u003e1000 speeds\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1bfv5z0\" dir=\"auto\" data-start=\"8444\" data-end=\"8508\"\u003e9. Does the LMDV111 have shear-rate and shear-force display?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8510\" data-end=\"8637\"\u003eNo. The catalogue specifies \u003cstrong data-start=\"8538\" data-end=\"8544\"\u003eNo\u003c\/strong\u003e for Shear Rate \/ Shear Force Display on the LMDV111. \u003cspan class=\"contents\" data-content-reference-start=\"8503\" data-content-reference-end=\"8533\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1p67iy2\" dir=\"auto\" data-start=\"8639\" data-end=\"8692\"\u003e10. Does the LMDV111 have temperature monitoring?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8694\" data-end=\"8744\"\u003eYes. \u003cstrong data-start=\"8699\" data-end=\"8730\"\u003eTemperature Monitoring: Yes\u003c\/strong\u003e is specified.\u003c\/p\u003e\n\u003ch3 data-section-id=\"dkwun9\" dir=\"auto\" data-start=\"8746\" data-end=\"8795\"\u003e11. Can the sample temperature be controlled?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8797\" data-end=\"9010\"\u003eYes. The catalogue states that sample temperature can be controlled using an \u003cstrong data-start=\"8874\" data-end=\"8916\"\u003eoptional Refrigerated Circulating Bath\u003c\/strong\u003e, with the sample chamber fitting into a water jacket. \u003cspan class=\"contents\" data-content-reference-start=\"8867\" data-content-reference-end=\"8897\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1pazci2\" dir=\"auto\" data-start=\"9012\" data-end=\"9053\"\u003e12. What is the measurement accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9055\" data-end=\"9104\"\u003eThe specified measurement accuracy is \u003cstrong data-start=\"9093\" data-end=\"9103\"\u003e±1% FS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yxgdl\" dir=\"auto\" data-start=\"9106\" data-end=\"9140\"\u003e13. What is the repeatability?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9142\" data-end=\"9186\"\u003eThe specified repeatability is \u003cstrong data-start=\"9173\" data-end=\"9185\"\u003e±0.5% FS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ebmx9x\" dir=\"auto\" data-start=\"9188\" data-end=\"9238\"\u003e14. Does the LMDV111 have an RS232C interface?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9240\" data-end=\"9296\"\u003eYes. The output is specified as an \u003cstrong data-start=\"9275\" data-end=\"9295\"\u003eRS232C Interface\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"oxh8ie\" dir=\"auto\" data-start=\"9298\" data-end=\"9331\"\u003e15. What is the power supply?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9333\" data-end=\"9395\"\u003eThe catalogue specifies an \u003cstrong data-start=\"9360\" data-end=\"9394\"\u003eadaptor using AC 220V, 50\/60Hz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"bwk228\" dir=\"auto\" data-start=\"9397\" data-end=\"9435\"\u003e16. What is the packing dimension?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9437\" data-end=\"9493\"\u003eThe LMDV111 packing dimension is \u003cstrong data-start=\"9470\" data-end=\"9492\"\u003e420 × 375 × 550 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"6q4i02\" dir=\"auto\" data-start=\"9495\" data-end=\"9528\"\u003e17. What is the gross weight?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9530\" data-end=\"9582\"\u003eThe catalogue specifies a gross weight of \u003cstrong data-start=\"9572\" data-end=\"9581\"\u003e15 kg\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52659730481449,"sku":"LMDV111","price":185299.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/rs_w_720_h_960_cg_true.webp?v=1777055655","url":"https:\/\/www.labmart.in\/products\/lmdv111-digital-viscometer-small-sample-adaptor","provider":"Labmart.in","version":"1.0","type":"link"}