{"product_id":"labmart-type-m1-disposable-fluorometer-cuvette-340-900nm","title":"(TYPE M1) Standard disposable Flurometer Cuvette","description":"\u003cp\u003eThe \u003cstrong\u003eLabmart Type M1 Standard Disposable Fluorometer Cuvette\u003c\/strong\u003e is a disposable PS cuvette designed for fluorometric laboratory measurements across the \u003cstrong\u003e340–900 nm wavelength range\u003c\/strong\u003e. It features thermally fused construction, highly transparent connected sides, a precision optical path with \u003cstrong\u003e±0.1 mm tolerance\u003c\/strong\u003e, and resistance to acids, alkalis and organic solvents.\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Overview\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe Type M1 Standard Disposable Fluorometer Cuvette is designed for routine fluorescence and fluorometric laboratory applications where a disposable optical cell is preferred. Its connected sides are manufactured using \u003cstrong\u003efire-flame or thermal fusing\u003c\/strong\u003e, avoiding glued and fritted assembly methods.\u003c\/p\u003e\n\u003cp\u003eThe fused construction provides highly transparent connected sides and a robust overall structure. The precision parallel optical path is specified with a \u003cstrong\u003e±0.1 mm light-path tolerance\u003c\/strong\u003e, supporting consistent optical measurements.\u003c\/p\u003e\n\u003cp\u003eThe cell also offers acid-proof, alkali-proof and organic-solvent resistance as specified, while its fused sides are designed to prevent testing materials from adhering to the connected surfaces and help avoid cross-pollution.\u003c\/p\u003e\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStandard disposable fluorometer cuvette\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePS construction\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e340–900 nm wavelength range\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eFire-flame or thermal-fused connected sides\u003c\/li\u003e\n\u003cli\u003eAvoids glued and fritted assembly\u003c\/li\u003e\n\u003cli\u003eHighly transparent connected surfaces\u003c\/li\u003e\n\u003cli\u003ePrecision parallel optical path\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e±0.1 mm light-path tolerance\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eGood acid resistance\u003c\/li\u003e\n\u003cli\u003eGood alkali resistance\u003c\/li\u003e\n\u003cli\u003eGood organic-solvent resistance\u003c\/li\u003e\n\u003cli\u003eFused sides help minimize cross-pollution\u003c\/li\u003e\n\u003cli\u003eWell-consistent and well-matched construction\u003c\/li\u003e\n\u003cli\u003eSuitable for routine fluorometric measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eStandard Disposable Fluorometer Cuvette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e340–900 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Path\u003c\/td\u003e\n\u003ctd\u003ePrecision parallel optical path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight-Path Tolerance\u003c\/td\u003e\n\u003ctd\u003e±0.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnected Side Construction\u003c\/td\u003e\n\u003ctd\u003eFire-flame or thermal fusing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly\u003c\/td\u003e\n\u003ctd\u003eFused; not glued or fritted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Transparency\u003c\/td\u003e\n\u003ctd\u003eHighly transparent connected sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcid Resistance\u003c\/td\u003e\n\u003ctd\u003eYes, as specified by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkali Resistance\u003c\/td\u003e\n\u003ctd\u003eYes, as specified by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrganic-Solvent Resistance\u003c\/td\u003e\n\u003ctd\u003eYes, as specified by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-Pollution\u003c\/td\u003e\n\u003ctd\u003eFused sides designed to prevent adhesion of testing materials and cross-pollution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsistency\u003c\/td\u003e\n\u003ctd\u003eWell consistent and well matched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003eNot specified by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity per Pack\u003c\/td\u003e\n\u003ctd\u003eNot specified by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003e5. Applications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eFluorometric analysis\u003c\/li\u003e\n\u003cli\u003eFluorescence measurements\u003c\/li\u003e\n\u003cli\u003eRoutine laboratory fluorescence testing\u003c\/li\u003e\n\u003cli\u003eChemical analysis\u003c\/li\u003e\n\u003cli\u003eAnalytical research\u003c\/li\u003e\n\u003cli\u003eQuality-control testing\u003c\/li\u003e\n\u003cli\u003eSample measurement using compatible fluorometers\u003c\/li\u003e\n\u003cli\u003eLaboratory workflows requiring disposable optical cells\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e6. Suitable For\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eResearch laboratories\u003c\/li\u003e\n\u003cli\u003eAnalytical laboratories\u003c\/li\u003e\n\u003cli\u003eChemical laboratories\u003c\/li\u003e\n\u003cli\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli\u003eIndustrial quality-control laboratories\u003c\/li\u003e\n\u003cli\u003eEducational and teaching laboratories\u003c\/li\u003e\n\u003cli\u003eFluorescence and fluorometry applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e7. Product Benefits\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisposable format:\u003c\/strong\u003e Convenient for routine testing and helps avoid repeated cleaning between samples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide specified wavelength range:\u003c\/strong\u003e Suitable for measurements from 340 to 900 nm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision optical path:\u003c\/strong\u003e ±0.1 mm tolerance supports consistent optical geometry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFused construction:\u003c\/strong\u003e Connected sides are thermally fused rather than glued or fritted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh transparency:\u003c\/strong\u003e Fused connected sides provide a highly transparent optical structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical resistance:\u003c\/strong\u003e Designed to resist acids, alkalis and organic solvents as specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced cross-pollution:\u003c\/strong\u003e Fused surfaces help prevent testing materials from adhering to connected sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsistent construction:\u003c\/strong\u003e Cuvettes are described as well consistent and well matched.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LARK","offers":[{"title":"Default Title","offer_id":53486526628137,"sku":"MDF-204","price":3099.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/M1_25bc1f62-1bd7-4660-9fcd-3548c011f76b.jpg?v=1788593705","url":"https:\/\/www.labmart.in\/products\/labmart-type-m1-disposable-fluorometer-cuvette-340-900nm","provider":"Labmart.in","version":"1.0","type":"link"}