{"product_id":"labmart-rfm970-automatic-digital-refractometer","title":"Automatic Digital Refractometer-RFM970","description":"\u003cp dir=\"auto\" data-start=\"159\" data-end=\"545\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"163\" data-end=\"205\"\u003eRFM970 Automatic Digital Refractometer\u003c\/strong\u003e is a touchscreen laboratory refractometer for measuring the refractive index of transparent and semi-transparent liquids and Brix of sugar solutions. It offers \u003cstrong data-start=\"366\" data-end=\"544\"\u003e0.00001 nD resolution, 0–100% Brix measurement, automatic temperature correction, thermostatic temperature control, 1024-result memory and approximately 2-second reading time\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"547\" data-end=\"580\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"582\" data-end=\"601\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"603\" data-end=\"885\"\u003eThe \u003cstrong data-start=\"607\" data-end=\"657\"\u003eLabmart RFM970 Automatic Digital Refractometer\u003c\/strong\u003e is designed for automated measurement of \u003cstrong data-start=\"699\" data-end=\"724\"\u003erefractive index (nD)\u003c\/strong\u003e and \u003cstrong data-start=\"729\" data-end=\"742\"\u003eBrix (BX)\u003c\/strong\u003e in suitable liquid samples. It can be used for transparent and semi-transparent liquids and for determining the Brix value of sugar solutions.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"887\" data-end=\"1166\"\u003eA key feature of the RFM970 is its \u003cstrong data-start=\"922\" data-end=\"984\"\u003ethermostatic temperature control of room temperature ±10°C\u003c\/strong\u003e, allowing temperature-controlled refractive-index and Brix measurements. The instrument automatically corrects the effect of temperature on Brix and displays the sample temperature.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1168\" data-end=\"1471\"\u003eThe touchscreen interface provides access to measurement functions and user-configurable settings such as scan times, measurement type, revision information, sample ID and calendar. The system can store up to \u003cstrong data-start=\"1377\" data-end=\"1405\"\u003e1024 measurement results\u003c\/strong\u003e, with password-protected calibration and USB\/RS232C connectivity.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1473\" data-end=\"1499\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1501\" data-end=\"2158\"\u003e\n\u003cli data-section-id=\"s8zsxz\" data-start=\"1501\" data-end=\"1535\"\u003eFully automatic measuring system\u003c\/li\u003e\n\u003cli data-section-id=\"usaw7q\" data-start=\"1536\" data-end=\"1583\"\u003e\u003cstrong data-start=\"1538\" data-end=\"1583\"\u003e1.30000–1.70000 nD refractive-index range\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"e61noj\" data-start=\"1584\" data-end=\"1611\"\u003e\u003cstrong data-start=\"1586\" data-end=\"1611\"\u003e0.00001 nD resolution\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"wq5a1t\" data-start=\"1612\" data-end=\"1635\"\u003e\u003cstrong data-start=\"1614\" data-end=\"1635\"\u003e0–100% Brix range\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1hdognx\" data-start=\"1636\" data-end=\"1663\"\u003e\u003cstrong data-start=\"1638\" data-end=\"1663\"\u003e0.01% Brix resolution\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"rq812d\" data-start=\"1664\" data-end=\"1705\"\u003eApproximately \u003cstrong data-start=\"1680\" data-end=\"1705\"\u003e2-second reading time\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t3oic8\" data-start=\"1706\" data-end=\"1768\"\u003e\u003cstrong data-start=\"1708\" data-end=\"1768\"\u003eThermostatic temperature control: room temperature ±10°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1lnuf2y\" data-start=\"1769\" data-end=\"1810\"\u003e\u003cstrong data-start=\"1771\" data-end=\"1810\"\u003e±0.5°C temperature-control accuracy\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1a507s2\" data-start=\"1811\" data-end=\"1864\"\u003eAutomatic correction of temperature effects on Brix\u003c\/li\u003e\n\u003cli data-section-id=\"zn8rjf\" data-start=\"1865\" data-end=\"1894\"\u003eDisplays sample temperature\u003c\/li\u003e\n\u003cli data-section-id=\"1mg6ngb\" data-start=\"1895\" data-end=\"1916\"\u003eTouchscreen display\u003c\/li\u003e\n\u003cli data-section-id=\"1x4e375\" data-start=\"1917\" data-end=\"1952\"\u003eMemory for up to \u003cstrong data-start=\"1936\" data-end=\"1952\"\u003e1024 results\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19a9qai\" data-start=\"1953\" data-end=\"1985\"\u003ePassword-protected calibration\u003c\/li\u003e\n\u003cli data-section-id=\"lmx1vf\" data-start=\"1986\" data-end=\"2004\"\u003eEasy-clean prism\u003c\/li\u003e\n\u003cli data-section-id=\"7pp7aj\" data-start=\"2005\" data-end=\"2058\"\u003eUser-configurable scan times and sample information\u003c\/li\u003e\n\u003cli data-section-id=\"1v4yelc\" data-start=\"2059\" data-end=\"2086\"\u003eUSB and RS232C interfaces\u003c\/li\u003e\n\u003cli data-section-id=\"srzntt\" data-start=\"2087\" data-end=\"2158\"\u003eDesigned for routine laboratory refractive-index and Brix measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2160\" data-end=\"2189\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2191\" data-end=\"3060\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2191\" data-end=\"2217\"\u003e\n\u003ctr data-start=\"2191\" data-end=\"2217\"\u003e\n\u003cth data-start=\"2191\" data-end=\"2207\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2207\" data-end=\"2217\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eRFM970\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2228\" data-end=\"3060\"\u003e\n\u003ctr data-start=\"2228\" data-end=\"2278\"\u003e\n\u003ctd data-start=\"2228\" data-end=\"2243\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2243\" data-end=\"2278\" data-col-size=\"sm\"\u003eAutomatic Digital Refractometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2279\" data-end=\"2297\"\u003e\n\u003ctd data-start=\"2279\" data-end=\"2287\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2287\" data-end=\"2297\" data-col-size=\"sm\"\u003eRFM970\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2298\" data-end=\"2317\"\u003e\n\u003ctd data-start=\"2298\" data-end=\"2306\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2306\" data-end=\"2317\" data-col-size=\"sm\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2318\" data-end=\"2343\"\u003e\n\u003ctd data-start=\"2318\" data-end=\"2328\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2328\" data-end=\"2343\" data-col-size=\"sm\"\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2344\" data-end=\"2403\"\u003e\n\u003ctd data-start=\"2344\" data-end=\"2381\" data-col-size=\"sm\"\u003eRefractive Index Measurement Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2381\" data-end=\"2403\"\u003e1.30000–1.70000 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2404\" data-end=\"2446\"\u003e\n\u003ctd data-start=\"2404\" data-end=\"2432\" data-col-size=\"sm\"\u003eRefractive Index Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2432\" data-end=\"2446\" data-col-size=\"sm\"\u003e±0.0002 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2447\" data-end=\"2491\"\u003e\n\u003ctd data-start=\"2447\" data-end=\"2477\" data-col-size=\"sm\"\u003eRefractive Index Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2477\" data-end=\"2491\" data-col-size=\"sm\"\u003e0.00001 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2492\" data-end=\"2525\"\u003e\n\u003ctd data-start=\"2492\" data-end=\"2515\" data-col-size=\"sm\"\u003eBrix Measuring Range\u003c\/td\u003e\n\u003ctd data-start=\"2515\" data-end=\"2525\" data-col-size=\"sm\"\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2526\" data-end=\"2563\"\u003e\n\u003ctd data-start=\"2526\" data-end=\"2554\" data-col-size=\"sm\"\u003eBrix Measurement Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2554\" data-end=\"2563\" data-col-size=\"sm\"\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2564\" data-end=\"2591\"\u003e\n\u003ctd data-start=\"2564\" data-end=\"2582\" data-col-size=\"sm\"\u003eBrix Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2582\" data-end=\"2591\" data-col-size=\"sm\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2592\" data-end=\"2630\"\u003e\n\u003ctd data-start=\"2592\" data-end=\"2620\" data-col-size=\"sm\"\u003eTemperature Display Range\u003c\/td\u003e\n\u003ctd data-start=\"2620\" data-end=\"2630\" data-col-size=\"sm\"\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2631\" data-end=\"2692\"\u003e\n\u003ctd data-start=\"2631\" data-end=\"2666\" data-col-size=\"sm\"\u003eThermostatic Temperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2666\" data-end=\"2692\" data-col-size=\"sm\"\u003eRoom Temperature ±10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2693\" data-end=\"2734\"\u003e\n\u003ctd data-start=\"2693\" data-end=\"2724\" data-col-size=\"sm\"\u003eTemperature Control Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2724\" data-end=\"2734\" data-col-size=\"sm\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2735\" data-end=\"2771\"\u003e\n\u003ctd data-start=\"2735\" data-end=\"2750\" data-col-size=\"sm\"\u003eReading Time\u003c\/td\u003e\n\u003ctd data-start=\"2750\" data-end=\"2771\" data-col-size=\"sm\"\u003eApprox. 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2772\" data-end=\"2802\"\u003e\n\u003ctd data-start=\"2772\" data-end=\"2781\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2781\" data-end=\"2802\" data-col-size=\"sm\"\u003e1024 data\/results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2803\" data-end=\"2839\"\u003e\n\u003ctd data-start=\"2803\" data-end=\"2817\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2817\" data-end=\"2839\" data-col-size=\"sm\"\u003ePassword protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2840\" data-end=\"2868\"\u003e\n\u003ctd data-start=\"2840\" data-end=\"2848\" data-col-size=\"sm\"\u003ePrism\u003c\/td\u003e\n\u003ctd data-start=\"2848\" data-end=\"2868\" data-col-size=\"sm\"\u003eEasy-clean prism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2869\" data-end=\"2888\"\u003e\n\u003ctd data-start=\"2869\" data-end=\"2881\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2881\" data-end=\"2888\" data-col-size=\"sm\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2889\" data-end=\"2924\"\u003e\n\u003ctd data-start=\"2889\" data-end=\"2908\" data-col-size=\"sm\"\u003eOutput Interface\u003c\/td\u003e\n\u003ctd data-start=\"2908\" data-end=\"2924\" data-col-size=\"sm\"\u003eRS232C \/ USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2925\" data-end=\"2960\"\u003e\n\u003ctd data-start=\"2925\" data-end=\"2940\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2940\" data-end=\"2960\" data-col-size=\"sm\"\u003eAC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2961\" data-end=\"3004\"\u003e\n\u003ctd data-start=\"2961\" data-end=\"2982\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2982\" data-end=\"3004\" data-col-size=\"sm\"\u003e500 × 340 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3005\" data-end=\"3036\"\u003e\n\u003ctd data-start=\"3005\" data-end=\"3020\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3020\" data-end=\"3036\" data-col-size=\"sm\"\u003eApprox. 9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3037\" data-end=\"3060\"\u003e\n\u003ctd data-start=\"3037\" data-end=\"3048\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"3048\" data-end=\"3060\" data-col-size=\"sm\"\u003e90275020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3062\" data-end=\"3079\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3081\" data-end=\"3146\"\u003eThe RFM970 is suitable for refractive-index and Brix analysis in:\u003c\/p\u003e\n\u003cul data-start=\"3148\" data-end=\"3392\"\u003e\n\u003cli data-section-id=\"1knpev4\" data-start=\"3148\" data-end=\"3172\"\u003ePetroleum laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3173\" data-end=\"3196\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3197\" data-end=\"3226\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1xvgs3w\" data-start=\"3227\" data-end=\"3243\"\u003eSugar refining\u003c\/li\u003e\n\u003cli data-section-id=\"1h4rb4o\" data-start=\"3244\" data-end=\"3274\"\u003eFood and beverage industries\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3275\" data-end=\"3305\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"3306\" data-end=\"3329\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"nyl6ft\" data-start=\"3330\" data-end=\"3357\"\u003eColleges and universities\u003c\/li\u003e\n\u003cli data-section-id=\"1w3jk51\" data-start=\"3358\" data-end=\"3392\"\u003eScientific research institutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3394\" data-end=\"3411\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3413\" data-end=\"3440\"\u003eThe RFM970 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3442\" data-end=\"3714\"\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"3442\" data-end=\"3474\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ogk9eo\" data-start=\"3475\" data-end=\"3516\"\u003eSugar and sugar-processing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"177hgrc\" data-start=\"3517\" data-end=\"3549\"\u003ePharmaceutical QC laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"vly2db\" data-start=\"3550\" data-end=\"3581\"\u003eChemical testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1knpev4\" data-start=\"3582\" data-end=\"3606\"\u003ePetroleum laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1qoxw4d\" data-start=\"3607\" data-end=\"3625\"\u003eR\u0026amp;D laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tnvors\" data-start=\"3626\" data-end=\"3649\"\u003eAcademic laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1w3jk51\" data-start=\"3650\" data-end=\"3684\"\u003eScientific research institutions\u003c\/li\u003e\n\u003cli data-section-id=\"rlkbyw\" data-start=\"3685\" data-end=\"3714\"\u003eQuality-control departments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"5798\" data-end=\"5808\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1oihf84\" dir=\"auto\" data-start=\"5810\" data-end=\"5845\"\u003e1. What is the RFM970 used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5846\" data-end=\"5976\"\u003eThe RFM970 is used for measuring \u003cstrong data-start=\"5879\" data-end=\"5943\"\u003erefractive index of transparent and semi-transparent liquids\u003c\/strong\u003e and \u003cstrong data-start=\"5948\" data-end=\"5975\"\u003eBrix of sugar solutions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1oqd2z3\" dir=\"auto\" data-start=\"5978\" data-end=\"6020\"\u003e2. What is the refractive-index range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6021\" data-end=\"6069\"\u003eThe measurement range is \u003cstrong data-start=\"6046\" data-end=\"6068\"\u003e1.30000–1.70000 nD\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vzkym7\" dir=\"auto\" data-start=\"6071\" data-end=\"6118\"\u003e3. What is the refractive-index resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6119\" data-end=\"6152\"\u003eThe resolution is \u003cstrong data-start=\"6137\" data-end=\"6151\"\u003e0.00001 nD\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2y9b60\" dir=\"auto\" data-start=\"6154\" data-end=\"6189\"\u003e4. Can the RFM970 measure Brix?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6190\" data-end=\"6243\"\u003eYes. It provides a \u003cstrong data-start=\"6209\" data-end=\"6242\"\u003e0–100% Brix measurement range\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1witfv4\" dir=\"auto\" data-start=\"6245\" data-end=\"6293\"\u003e5. Does the RFM970 have temperature control?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6294\" data-end=\"6382\"\u003eYes. The RFM970 provides \u003cstrong data-start=\"6319\" data-end=\"6381\"\u003ethermostatic temperature control of room temperature ±10°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iafd8z\" dir=\"auto\" data-start=\"6384\" data-end=\"6432\"\u003e6. What is the temperature-control accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6433\" data-end=\"6490\"\u003eThe specified temperature-control accuracy is \u003cstrong data-start=\"6479\" data-end=\"6489\"\u003e±0.5°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"icawp9\" dir=\"auto\" data-start=\"6492\" data-end=\"6550\"\u003e7. Does it automatically correct Brix for temperature?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6551\" data-end=\"6644\"\u003eYes. The instrument automatically corrects the effect of temperature on the Brix measurement.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nw73lb\" dir=\"auto\" data-start=\"6646\" data-end=\"6691\"\u003e8. How quickly does it provide a reading?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6692\" data-end=\"6750\"\u003eThe specified reading time is approximately \u003cstrong data-start=\"6736\" data-end=\"6749\"\u003e2 seconds\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qo3gr3\" dir=\"auto\" data-start=\"6752\" data-end=\"6790\"\u003e9. How many results can be stored?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6791\" data-end=\"6848\"\u003eThe RFM970 can store up to \u003cstrong data-start=\"6818\" data-end=\"6847\"\u003e1024 results\/data records\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rid643\" dir=\"auto\" data-start=\"6850\" data-end=\"6892\"\u003e10. Is calibration password protected?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6893\" data-end=\"6957\"\u003eYes. The catalogue specifies \u003cstrong data-start=\"6922\" data-end=\"6956\"\u003epassword-protected calibration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7xhsmn\" dir=\"auto\" data-start=\"6959\" data-end=\"7009\"\u003e11. What type of display does the RFM970 have?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7010\" data-end=\"7043\"\u003eIt has a \u003cstrong data-start=\"7019\" data-end=\"7042\"\u003etouchscreen display\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kdrcdt\" dir=\"auto\" data-start=\"7045\" data-end=\"7078\"\u003e12. What is the power supply?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7079\" data-end=\"7130\"\u003eThe specified power supply is \u003cstrong data-start=\"7109\" data-end=\"7129\"\u003eAC 220V, 50\/60Hz\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":50180285792553,"sku":"RFM970","price":414799.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/AutomaticDigitalRefractometer.jpg?v=1777307654","url":"https:\/\/www.labmart.in\/products\/labmart-rfm970-automatic-digital-refractometer","provider":"Labmart.in","version":"1.0","type":"link"}