{"product_id":"labmart-rfm950-automatic-digital-refractometer","title":"Automatic Digital Refractometer-RFM950","description":"\u003cp dir=\"auto\" data-start=\"151\" data-end=\"571\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"155\" data-end=\"197\"\u003eRFM950 Automatic Digital Refractometer\u003c\/strong\u003e is a touchscreen laboratory refractometer for measuring the refractive index of transparent and semi-transparent liquids and determining Brix values of sugar solutions. It provides \u003cstrong data-start=\"379\" data-end=\"404\"\u003e0.00001 nD resolution\u003c\/strong\u003e, 0–100% Brix measurement, approximately \u003cstrong data-start=\"445\" data-end=\"470\"\u003e2-second reading time\u003c\/strong\u003e, automatic temperature compensation for Brix, 1024-result memory and password-protected calibration.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"573\" data-end=\"606\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"608\" data-end=\"627\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"629\" data-end=\"920\"\u003eThe \u003cstrong data-start=\"633\" data-end=\"683\"\u003eLabmart RFM950 Automatic Digital Refractometer\u003c\/strong\u003e is designed for automated measurement of \u003cstrong data-start=\"725\" data-end=\"750\"\u003erefractive index (nD)\u003c\/strong\u003e in transparent and semi-transparent liquids. It can also measure \u003cstrong data-start=\"816\" data-end=\"829\"\u003eBrix (BX)\u003c\/strong\u003e of sugar solutions and automatically correct the effect of temperature on the Brix result.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"922\" data-end=\"1350\"\u003eThe instrument combines a \u003cstrong data-start=\"948\" data-end=\"973\"\u003etouchscreen interface\u003c\/strong\u003e, automatic measuring system and easy-clean prism for routine laboratory operation. According to the supplied catalogue, the RFM950 provides readings in approximately \u003cstrong data-start=\"1140\" data-end=\"1153\"\u003e2 seconds\u003c\/strong\u003e, stores up to \u003cstrong data-start=\"1168\" data-end=\"1196\"\u003e1024 measurement results\u003c\/strong\u003e, and allows users to configure scan times, measurement type, revision information, sample ID and calendar settings. \u003cspan class=\"contents\" data-content-reference-start=\"1313\" data-content-reference-end=\"1343\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1352\" data-end=\"1655\"\u003eThe catalogue's specification table lists the \u003cstrong data-start=\"1398\" data-end=\"1428\"\u003eRFM950 and RFM970 together\u003c\/strong\u003e, with the RFM970 additionally identified as having thermostatic temperature control of room temperature ±10°C. The RFM950 does not have a specified thermostatic control range in the table. \u003cspan class=\"contents\" data-content-reference-start=\"1611\" data-content-reference-end=\"1641\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1657\" data-end=\"1683\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1685\" data-end=\"2195\"\u003e\n\u003cli data-section-id=\"s8zsxz\" data-start=\"1685\" data-end=\"1719\"\u003eFully automatic measuring system\u003c\/li\u003e\n\u003cli data-section-id=\"1mg6ngb\" data-start=\"1720\" data-end=\"1741\"\u003eTouchscreen display\u003c\/li\u003e\n\u003cli data-section-id=\"4ow3pb\" data-start=\"1742\" data-end=\"1792\"\u003eRefractive-index range of \u003cstrong data-start=\"1770\" data-end=\"1792\"\u003e1.30000–1.70000 nD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"e61noj\" data-start=\"1793\" data-end=\"1820\"\u003e\u003cstrong data-start=\"1795\" data-end=\"1820\"\u003e0.00001 nD resolution\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"wq5a1t\" data-start=\"1821\" data-end=\"1844\"\u003e\u003cstrong data-start=\"1823\" data-end=\"1844\"\u003e0–100% Brix range\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1loq568\" data-start=\"1845\" data-end=\"1884\"\u003eApproximate \u003cstrong data-start=\"1859\" data-end=\"1884\"\u003e2-second reading time\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"bppwc1\" data-start=\"1885\" data-end=\"1937\"\u003eAutomatic correction of temperature effect on Brix\u003c\/li\u003e\n\u003cli data-section-id=\"zn8rjf\" data-start=\"1938\" data-end=\"1967\"\u003eDisplays sample temperature\u003c\/li\u003e\n\u003cli data-section-id=\"ufhcbr\" data-start=\"1968\" data-end=\"1999\"\u003eStores up to \u003cstrong data-start=\"1983\" data-end=\"1999\"\u003e1024 results\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19a9qai\" data-start=\"2000\" data-end=\"2032\"\u003ePassword-protected calibration\u003c\/li\u003e\n\u003cli data-section-id=\"lmx1vf\" data-start=\"2033\" data-end=\"2051\"\u003eEasy-clean prism\u003c\/li\u003e\n\u003cli data-section-id=\"7pp7aj\" data-start=\"2052\" data-end=\"2105\"\u003eUser-configurable scan times and sample information\u003c\/li\u003e\n\u003cli data-section-id=\"syluwp\" data-start=\"2106\" data-end=\"2126\"\u003eUSB data interface\u003c\/li\u003e\n\u003cli data-section-id=\"xefsvc\" data-start=\"2127\" data-end=\"2158\"\u003eRS232C \/ USB output interface\u003c\/li\u003e\n\u003cli data-section-id=\"a05oc7\" data-start=\"2159\" data-end=\"2195\"\u003eCompact benchtop laboratory design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2197\" data-end=\"2226\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2228\" data-end=\"3080\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2228\" data-end=\"2254\"\u003e\n\u003ctr data-start=\"2228\" data-end=\"2254\"\u003e\n\u003cth data-start=\"2228\" data-end=\"2244\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2244\" data-end=\"2254\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eRFM950\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2265\" data-end=\"3080\"\u003e\n\u003ctr data-start=\"2265\" data-end=\"2315\"\u003e\n\u003ctd data-start=\"2265\" data-end=\"2280\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2280\" data-end=\"2315\" data-col-size=\"sm\"\u003eAutomatic Digital Refractometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2316\" data-end=\"2334\"\u003e\n\u003ctd data-start=\"2316\" data-end=\"2324\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2324\" data-end=\"2334\" data-col-size=\"sm\"\u003eRFM950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2335\" data-end=\"2354\"\u003e\n\u003ctd data-start=\"2335\" data-end=\"2343\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2343\" data-end=\"2354\" data-col-size=\"sm\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2355\" data-end=\"2380\"\u003e\n\u003ctd data-start=\"2355\" data-end=\"2365\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2365\" data-end=\"2380\" data-col-size=\"sm\"\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2381\" data-end=\"2428\"\u003e\n\u003ctd data-start=\"2381\" data-end=\"2406\" data-col-size=\"sm\"\u003eRefractive Index Range\u003c\/td\u003e\n\u003ctd data-start=\"2406\" data-end=\"2428\" data-col-size=\"sm\"\u003e1.30000–1.70000 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2429\" data-end=\"2471\"\u003e\n\u003ctd data-start=\"2429\" data-end=\"2457\" data-col-size=\"sm\"\u003eRefractive Index Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2457\" data-end=\"2471\" data-col-size=\"sm\"\u003e±0.0002 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2472\" data-end=\"2516\"\u003e\n\u003ctd data-start=\"2472\" data-end=\"2502\" data-col-size=\"sm\"\u003eRefractive Index Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2502\" data-end=\"2516\" data-col-size=\"sm\"\u003e0.00001 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2517\" data-end=\"2540\"\u003e\n\u003ctd data-start=\"2517\" data-end=\"2530\" data-col-size=\"sm\"\u003eBrix Range\u003c\/td\u003e\n\u003ctd data-start=\"2530\" data-end=\"2540\" data-col-size=\"sm\"\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2541\" data-end=\"2583\"\u003e\n\u003ctd data-start=\"2541\" data-end=\"2574\" data-col-size=\"sm\"\u003eDissolved Solids Brix Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2574\" data-end=\"2583\" data-col-size=\"sm\"\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2584\" data-end=\"2611\"\u003e\n\u003ctd data-start=\"2584\" data-end=\"2602\" data-col-size=\"sm\"\u003eBrix Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2602\" data-end=\"2611\" data-col-size=\"sm\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2612\" data-end=\"2650\"\u003e\n\u003ctd data-start=\"2612\" data-end=\"2640\" data-col-size=\"sm\"\u003eTemperature Display Range\u003c\/td\u003e\n\u003ctd data-start=\"2640\" data-end=\"2650\" data-col-size=\"sm\"\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2651\" data-end=\"2708\"\u003e\n\u003ctd data-start=\"2651\" data-end=\"2680\" data-col-size=\"sm\"\u003eThermostatic Control Range\u003c\/td\u003e\n\u003ctd data-start=\"2680\" data-end=\"2708\" data-col-size=\"sm\"\u003eNot specified for RFM950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2709\" data-end=\"2750\"\u003e\n\u003ctd data-start=\"2709\" data-end=\"2740\" data-col-size=\"sm\"\u003eTemperature Control Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2740\" data-end=\"2750\" data-col-size=\"sm\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2751\" data-end=\"2791\"\u003e\n\u003ctd data-start=\"2751\" data-end=\"2770\" data-col-size=\"sm\"\u003eMeasurement Time\u003c\/td\u003e\n\u003ctd data-start=\"2770\" data-end=\"2791\" data-col-size=\"sm\"\u003eApprox. 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2792\" data-end=\"2822\"\u003e\n\u003ctd data-start=\"2792\" data-end=\"2801\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2801\" data-end=\"2822\" data-col-size=\"sm\"\u003e1024 data\/results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2823\" data-end=\"2859\"\u003e\n\u003ctd data-start=\"2823\" data-end=\"2837\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2837\" data-end=\"2859\" data-col-size=\"sm\"\u003ePassword protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2860\" data-end=\"2888\"\u003e\n\u003ctd data-start=\"2860\" data-end=\"2868\" data-col-size=\"sm\"\u003ePrism\u003c\/td\u003e\n\u003ctd data-start=\"2868\" data-end=\"2888\" data-col-size=\"sm\"\u003eEasy-clean prism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2889\" data-end=\"2908\"\u003e\n\u003ctd data-start=\"2889\" data-end=\"2901\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2901\" data-end=\"2908\" data-col-size=\"sm\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2909\" data-end=\"2944\"\u003e\n\u003ctd data-start=\"2909\" data-end=\"2924\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2924\" data-end=\"2944\" data-col-size=\"sm\"\u003eAC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2945\" data-end=\"2980\"\u003e\n\u003ctd data-start=\"2945\" data-end=\"2964\" data-col-size=\"sm\"\u003eOutput Interface\u003c\/td\u003e\n\u003ctd data-start=\"2964\" data-end=\"2980\" data-col-size=\"sm\"\u003eRS232C \/ USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2981\" data-end=\"3024\"\u003e\n\u003ctd data-start=\"2981\" data-end=\"3002\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"3002\" data-end=\"3024\" data-col-size=\"sm\"\u003e500 × 340 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3025\" data-end=\"3056\"\u003e\n\u003ctd data-start=\"3025\" data-end=\"3040\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3040\" data-end=\"3056\" data-col-size=\"sm\"\u003eApprox. 8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3057\" data-end=\"3080\"\u003e\n\u003ctd data-start=\"3057\" data-end=\"3068\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"3068\" data-end=\"3080\" data-col-size=\"sm\"\u003e90275020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"3082\" data-end=\"3297\"\u003eThe specifications above are taken from the RFM950\/RFM970 specification table; where the table provides a shared specification for both models, it has been retained accordingly. \u003cspan class=\"contents\" data-content-reference-start=\"3246\" data-content-reference-end=\"3276\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3299\" data-end=\"3316\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3318\" data-end=\"3394\"\u003eThe supplied catalogue specifically identifies the RFM950\/RFM970 for use in:\u003c\/p\u003e\n\u003cul data-start=\"3396\" data-end=\"3558\"\u003e\n\u003cli data-section-id=\"47mi7z\" data-start=\"3396\" data-end=\"3416\"\u003ePetroleum industry\u003c\/li\u003e\n\u003cli data-section-id=\"ne18ty\" data-start=\"3417\" data-end=\"3436\"\u003eChemical industry\u003c\/li\u003e\n\u003cli data-section-id=\"q8xg0l\" data-start=\"3437\" data-end=\"3462\"\u003ePharmaceutical industry\u003c\/li\u003e\n\u003cli data-section-id=\"1xvgs3w\" data-start=\"3463\" data-end=\"3479\"\u003eSugar refining\u003c\/li\u003e\n\u003cli data-section-id=\"1bbpi1c\" data-start=\"3480\" data-end=\"3495\"\u003eFood industry\u003c\/li\u003e\n\u003cli data-section-id=\"nyl6ft\" data-start=\"3496\" data-end=\"3523\"\u003eColleges and universities\u003c\/li\u003e\n\u003cli data-section-id=\"1w3jk51\" data-start=\"3524\" data-end=\"3558\"\u003eScientific research institutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"3560\" data-end=\"3712\"\u003eIt is used for measuring refractive index of transparent and semi-transparent liquids and Brix of sugar solutions. \u003cspan class=\"contents\" data-content-reference-start=\"3654\" data-content-reference-end=\"3684\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3714\" data-end=\"3731\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3733\" data-end=\"3760\"\u003eThe RFM950 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3762\" data-end=\"4043\"\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"3762\" data-end=\"3794\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ogk9eo\" data-start=\"3795\" data-end=\"3836\"\u003eSugar and sugar-processing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3837\" data-end=\"3866\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3867\" data-end=\"3890\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"gkg9cm\" data-start=\"3891\" data-end=\"3930\"\u003ePetroleum-related laboratory analysis\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3931\" data-end=\"3961\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1qoxw4d\" data-start=\"3962\" data-end=\"3980\"\u003eR\u0026amp;D laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"167fuah\" data-start=\"3981\" data-end=\"4008\"\u003eUniversities and colleges\u003c\/li\u003e\n\u003cli data-section-id=\"1w3jk51\" data-start=\"4009\" data-end=\"4043\"\u003eScientific research institutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"6126\" data-end=\"6136\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1t0ffkm\" dir=\"auto\" data-start=\"6138\" data-end=\"6173\"\u003e1. What is the RFM950 used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6174\" data-end=\"6301\"\u003eThe RFM950 is used to measure \u003cstrong data-start=\"6204\" data-end=\"6268\"\u003erefractive index of transparent and semi-transparent liquids\u003c\/strong\u003e and \u003cstrong data-start=\"6273\" data-end=\"6300\"\u003eBrix of sugar solutions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1oqd2z3\" dir=\"auto\" data-start=\"6303\" data-end=\"6345\"\u003e2. What is the refractive-index range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6346\" data-end=\"6394\"\u003eThe measurement range is \u003cstrong data-start=\"6371\" data-end=\"6393\"\u003e1.30000–1.70000 nD\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vzkym7\" dir=\"auto\" data-start=\"6396\" data-end=\"6443\"\u003e3. What is the refractive-index resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6444\" data-end=\"6477\"\u003eThe resolution is \u003cstrong data-start=\"6462\" data-end=\"6476\"\u003e0.00001 nD\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"119r8ga\" dir=\"auto\" data-start=\"6479\" data-end=\"6514\"\u003e4. Can the RFM950 measure Brix?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6515\" data-end=\"6568\"\u003eYes. It provides a \u003cstrong data-start=\"6534\" data-end=\"6567\"\u003e0–100% Brix measurement range\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1afzwa5\" dir=\"auto\" data-start=\"6570\" data-end=\"6642\"\u003e5. Does it automatically compensate for temperature effects on Brix?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6643\" data-end=\"6727\"\u003eYes. The catalogue specifies automatic correction of the temperature effect on Brix.\u003c\/p\u003e\n\u003ch3 data-section-id=\"awls0w\" dir=\"auto\" data-start=\"6729\" data-end=\"6782\"\u003e6. How quickly does the RFM950 provide a reading?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6783\" data-end=\"6841\"\u003eThe specified reading time is approximately \u003cstrong data-start=\"6827\" data-end=\"6840\"\u003e2 seconds\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"jav9vl\" dir=\"auto\" data-start=\"6843\" data-end=\"6881\"\u003e7. How many results can be stored?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6882\" data-end=\"6943\"\u003eThe instrument can store up to \u003cstrong data-start=\"6913\" data-end=\"6942\"\u003e1024 results\/data records\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxlvai\" dir=\"auto\" data-start=\"6945\" data-end=\"6986\"\u003e8. Is calibration password protected?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6987\" data-end=\"7051\"\u003eYes. The catalogue specifies \u003cstrong data-start=\"7016\" data-end=\"7050\"\u003epassword-protected calibration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1l50zhr\" dir=\"auto\" data-start=\"7053\" data-end=\"7107\"\u003e9. Does the instrument display sample temperature?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7108\" data-end=\"7174\"\u003eYes. The instrument can display the \u003cstrong data-start=\"7144\" data-end=\"7173\"\u003etemperature of the sample\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qwem19\" dir=\"auto\" data-start=\"7176\" data-end=\"7218\"\u003e10. What type of display does it have?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7219\" data-end=\"7261\"\u003eThe RFM950 uses a \u003cstrong data-start=\"7237\" data-end=\"7260\"\u003etouchscreen display\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1coly4x\" dir=\"auto\" data-start=\"7263\" data-end=\"7299\"\u003e11. What is the Brix resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7300\" data-end=\"7333\"\u003eThe Brix resolution is \u003cstrong data-start=\"7323\" data-end=\"7332\"\u003e0.01%\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ewmxg9\" dir=\"auto\" data-start=\"7335\" data-end=\"7406\"\u003e12. Does the RFM950 have built-in thermostatic temperature control?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7407\" data-end=\"7612\"\u003eThe specification table lists \u003cstrong data-start=\"7437\" data-end=\"7482\"\u003ethermostatic control as NA for the RFM950\u003c\/strong\u003e. The RFM970, in contrast, is specified with thermostatic control of room temperature ±10°C.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":50180379443497,"sku":"RFM950","price":255750.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/RFM950_970_Clean_White_Background.png?v=1790590135","url":"https:\/\/www.labmart.in\/products\/labmart-rfm950-automatic-digital-refractometer","provider":"Labmart.in","version":"1.0","type":"link"}