{"product_id":"labmart-rfm100cfr-automatic-digital-refractometer","title":"Automatic Digital Refractometer RFM100CFR","description":"\u003cp dir=\"auto\" data-start=\"146\" data-end=\"529\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"150\" data-end=\"195\"\u003eRFM100CFR Automatic Digital Refractometer\u003c\/strong\u003e is a touchscreen refractometer designed for precise refractive-index and Brix measurement with integrated temperature control. It features a \u003cstrong data-start=\"337\" data-end=\"528\"\u003e1.30000–1.70000 nD range, 0.00001 nD resolution, 0–100% Brix range, built-in Peltier temperature control, 16GB storage, 12 measurement methods and electronic signature\/password management\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"531\" data-end=\"564\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"566\" data-end=\"585\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"587\" data-end=\"812\"\u003eThe \u003cstrong data-start=\"591\" data-end=\"644\"\u003eLabmart RFM100CFR Automatic Digital Refractometer\u003c\/strong\u003e is an advanced laboratory refractometer for measuring the refractive index of liquids and determining concentration values in suitable measurement units such as °Brix.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"814\" data-end=\"1131\"\u003eThe instrument combines a \u003cstrong data-start=\"840\" data-end=\"880\"\u003ehigh-resolution CCD detection system\u003c\/strong\u003e, artificial sapphire prism, integrated Peltier temperature control and an \u003cstrong data-start=\"955\" data-end=\"984\"\u003e8-inch colour touchscreen\u003c\/strong\u003e in a self-contained system. Its Windows operating system and built-in software allow measurements to be performed without requiring a separate PC.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1133\" data-end=\"1421\"\u003eDesigned for laboratories requiring controlled electronic data handling, the RFM100CFR incorporates \u003cstrong data-start=\"1233\" data-end=\"1339\"\u003eelectronic signatures, password management and functions specified for GMP, GLP and FDA 21 CFR Part 11\u003c\/strong\u003e. It also provides 16GB internal memory and 12 built-in measurement modes\/methods.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1423\" data-end=\"1449\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1451\" data-end=\"2282\"\u003e\n\u003cli data-section-id=\"1mzd449\" data-start=\"1451\" data-end=\"1503\"\u003e\u003cstrong data-start=\"1453\" data-end=\"1503\"\u003eAutomatic digital refractive-index measurement\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"4ow3pb\" data-start=\"1504\" data-end=\"1554\"\u003eRefractive-index range of \u003cstrong data-start=\"1532\" data-end=\"1554\"\u003e1.30000–1.70000 nD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"e61noj\" data-start=\"1555\" data-end=\"1582\"\u003e\u003cstrong data-start=\"1557\" data-end=\"1582\"\u003e0.00001 nD resolution\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"2rth18\" data-start=\"1583\" data-end=\"1616\"\u003e\u003cstrong data-start=\"1585\" data-end=\"1616\"\u003e0–100% Brix measuring range\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1oijrw\" data-start=\"1617\" data-end=\"1659\"\u003eBuilt-in \u003cstrong data-start=\"1628\" data-end=\"1659\"\u003ePeltier temperature control\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9edhy9\" data-start=\"1660\" data-end=\"1731\"\u003eTemperature control range of \u003cstrong data-start=\"1691\" data-end=\"1706\"\u003e5°C to 85°C\u003c\/strong\u003e at 20°C room temperature\u003c\/li\u003e\n\u003cli data-section-id=\"12or7cg\" data-start=\"1732\" data-end=\"1763\"\u003e\u003cstrong data-start=\"1734\" data-end=\"1763\"\u003e8-inch colour touchscreen\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"3f5w4r\" data-start=\"1764\" data-end=\"1806\"\u003eHigh-resolution \u003cstrong data-start=\"1782\" data-end=\"1806\"\u003eCCD detection system\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nvmcq2\" data-start=\"1807\" data-end=\"1843\"\u003eArtificial \u003cstrong data-start=\"1820\" data-end=\"1843\"\u003esapphire-type prism\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"h2op0v\" data-start=\"1844\" data-end=\"1870\"\u003eWindows operating system\u003c\/li\u003e\n\u003cli data-section-id=\"3j69hr\" data-start=\"1871\" data-end=\"1930\"\u003eBuilt-in software — no separate PC required for operation\u003c\/li\u003e\n\u003cli data-section-id=\"ui6h3g\" data-start=\"1931\" data-end=\"1957\"\u003e\u003cstrong data-start=\"1933\" data-end=\"1957\"\u003e16GB internal memory\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"dmgbr5\" data-start=\"1958\" data-end=\"1995\"\u003e\u003cstrong data-start=\"1960\" data-end=\"1995\"\u003e12 built-in measurement methods\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"4lnuvx\" data-start=\"1996\" data-end=\"2019\"\u003eElectronic signatures\u003c\/li\u003e\n\u003cli data-section-id=\"1moq02s\" data-start=\"2020\" data-end=\"2041\"\u003ePassword management\u003c\/li\u003e\n\u003cli data-section-id=\"11mjr9u\" data-start=\"2042\" data-end=\"2101\"\u003eGMP \/ GLP \/ FDA 21 CFR Part 11 functionality as specified\u003c\/li\u003e\n\u003cli data-section-id=\"1rcdd2a\" data-start=\"2102\" data-end=\"2130\"\u003eMultiple measurement modes\u003c\/li\u003e\n\u003cli data-section-id=\"1n6ymg9\" data-start=\"2131\" data-end=\"2183\"\u003eFast measurement requiring a small sample quantity\u003c\/li\u003e\n\u003cli data-section-id=\"1l6121y\" data-start=\"2184\" data-end=\"2245\"\u003eUSB keyboard\/mouse, Ethernet and optional WLAN connectivity\u003c\/li\u003e\n\u003cli data-section-id=\"duk2x2\" data-start=\"2246\" data-end=\"2282\"\u003eCompact benchtop laboratory format\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2284\" data-end=\"2313\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2315\" data-end=\"3550\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2315\" data-end=\"2344\"\u003e\n\u003ctr data-start=\"2315\" data-end=\"2344\"\u003e\n\u003cth data-start=\"2315\" data-end=\"2331\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2331\" data-end=\"2344\" data-col-size=\"md\" class=\"last:pe-10\"\u003eRFM100CFR\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2355\" data-end=\"3550\"\u003e\n\u003ctr data-start=\"2355\" data-end=\"2405\"\u003e\n\u003ctd data-start=\"2355\" data-end=\"2370\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2370\" data-end=\"2405\" data-col-size=\"md\"\u003eAutomatic Digital Refractometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2406\" data-end=\"2427\"\u003e\n\u003ctd data-start=\"2406\" data-end=\"2414\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2414\" data-end=\"2427\" data-col-size=\"md\"\u003eRFM100CFR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2428\" data-end=\"2447\"\u003e\n\u003ctd data-start=\"2428\" data-end=\"2436\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2436\" data-end=\"2447\" data-col-size=\"md\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2448\" data-end=\"2507\"\u003e\n\u003ctd data-start=\"2448\" data-end=\"2485\" data-col-size=\"sm\"\u003eRefractive Index Measurement Range\u003c\/td\u003e\n\u003ctd data-start=\"2485\" data-end=\"2507\" data-col-size=\"md\"\u003e1.30000–1.70000 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2508\" data-end=\"2559\"\u003e\n\u003ctd data-start=\"2508\" data-end=\"2545\" data-col-size=\"sm\"\u003eRefractive Index Measurement Error\u003c\/td\u003e\n\u003ctd data-start=\"2545\" data-end=\"2559\" data-col-size=\"md\"\u003e±0.0002 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2560\" data-end=\"2604\"\u003e\n\u003ctd data-start=\"2560\" data-end=\"2590\" data-col-size=\"sm\"\u003eRefractive Index Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2590\" data-end=\"2604\" data-col-size=\"md\"\u003e0.00001 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2605\" data-end=\"2660\"\u003e\n\u003ctd data-start=\"2605\" data-end=\"2645\" data-col-size=\"sm\"\u003eRefractive Index Measurement Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2645\" data-end=\"2660\" data-col-size=\"md\"\u003e±0.00001 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2661\" data-end=\"2700\"\u003e\n\u003ctd data-start=\"2661\" data-end=\"2684\" data-col-size=\"sm\"\u003eBrix Measuring Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2684\" data-end=\"2700\"\u003e0–100% °Brix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2701\" data-end=\"2735\"\u003e\n\u003ctd data-start=\"2701\" data-end=\"2726\" data-col-size=\"sm\"\u003eBrix Measurement Error\u003c\/td\u003e\n\u003ctd data-start=\"2726\" data-end=\"2735\" data-col-size=\"md\"\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2736\" data-end=\"2763\"\u003e\n\u003ctd data-start=\"2736\" data-end=\"2754\" data-col-size=\"sm\"\u003eBrix Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2754\" data-end=\"2763\" data-col-size=\"md\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2764\" data-end=\"2801\"\u003e\n\u003ctd data-start=\"2764\" data-end=\"2792\" data-col-size=\"sm\"\u003eBrix Measurement Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2792\" data-end=\"2801\"\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2802\" data-end=\"2844\"\u003e\n\u003ctd data-start=\"2802\" data-end=\"2824\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2824\" data-end=\"2844\" data-col-size=\"md\"\u003eBuilt-in Peltier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2845\" data-end=\"2886\"\u003e\n\u003ctd data-start=\"2845\" data-end=\"2873\" data-col-size=\"sm\"\u003eTemperature Display Range\u003c\/td\u003e\n\u003ctd data-start=\"2873\" data-end=\"2886\" data-col-size=\"md\"\u003e0°C–100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2887\" data-end=\"2952\"\u003e\n\u003ctd data-start=\"2887\" data-end=\"2915\" data-col-size=\"sm\"\u003eTemperature Control Range\u003c\/td\u003e\n\u003ctd data-start=\"2915\" data-end=\"2952\" data-col-size=\"md\"\u003e5°C–85°C at 20°C room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2953\" data-end=\"2988\"\u003e\n\u003ctd data-start=\"2953\" data-end=\"2978\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2978\" data-end=\"2988\" data-col-size=\"md\"\u003e0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2989\" data-end=\"3031\"\u003e\n\u003ctd data-start=\"2989\" data-end=\"3020\" data-col-size=\"sm\"\u003eTemperature Control Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3020\" data-end=\"3031\" data-col-size=\"md\"\u003e±0.02°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3032\" data-end=\"3071\"\u003e\n\u003ctd data-start=\"3032\" data-end=\"3042\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3042\" data-end=\"3071\"\u003e8-inch Colour Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3072\" data-end=\"3102\"\u003e\n\u003ctd data-start=\"3072\" data-end=\"3091\" data-col-size=\"sm\"\u003eOperating System\u003c\/td\u003e\n\u003ctd data-start=\"3091\" data-end=\"3102\" data-col-size=\"md\"\u003eWindows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3103\" data-end=\"3126\"\u003e\n\u003ctd data-start=\"3103\" data-end=\"3114\" data-col-size=\"sm\"\u003eSoftware\u003c\/td\u003e\n\u003ctd data-start=\"3114\" data-end=\"3126\" data-col-size=\"md\"\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3127\" data-end=\"3169\"\u003e\n\u003ctd data-start=\"3127\" data-end=\"3146\" data-col-size=\"sm\"\u003eDetection System\u003c\/td\u003e\n\u003ctd data-start=\"3146\" data-end=\"3169\" data-col-size=\"md\"\u003eHigh-resolution CCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3170\" data-end=\"3195\"\u003e\n\u003ctd data-start=\"3170\" data-end=\"3178\" data-col-size=\"sm\"\u003ePrism\u003c\/td\u003e\n\u003ctd data-start=\"3178\" data-end=\"3195\" data-col-size=\"md\"\u003eSapphire Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3196\" data-end=\"3213\"\u003e\n\u003ctd data-start=\"3196\" data-end=\"3205\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3205\" data-end=\"3213\" data-col-size=\"md\"\u003e16GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3214\" data-end=\"3244\"\u003e\n\u003ctd data-start=\"3214\" data-end=\"3237\" data-col-size=\"sm\"\u003eElectronic Signature\u003c\/td\u003e\n\u003ctd data-start=\"3237\" data-end=\"3244\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3245\" data-end=\"3279\"\u003e\n\u003ctd data-start=\"3245\" data-end=\"3267\" data-col-size=\"sm\"\u003eMeasurement Methods\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3267\" data-end=\"3279\"\u003e12 Types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3280\" data-end=\"3357\"\u003e\n\u003ctd data-start=\"3280\" data-end=\"3323\" data-col-size=\"sm\"\u003eCompliance \/ Electronic Record Functions\u003c\/td\u003e\n\u003ctd data-start=\"3323\" data-end=\"3357\" data-col-size=\"md\"\u003eGMP \/ GLP \/ FDA 21 CFR Part 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3358\" data-end=\"3422\"\u003e\n\u003ctd data-start=\"3358\" data-end=\"3371\" data-col-size=\"sm\"\u003eInterfaces\u003c\/td\u003e\n\u003ctd data-start=\"3371\" data-end=\"3422\" data-col-size=\"md\"\u003eUSB Keyboard \/ Mouse \/ Ethernet \/ Optional WLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3423\" data-end=\"3458\"\u003e\n\u003ctd data-start=\"3423\" data-end=\"3438\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3438\" data-end=\"3458\" data-col-size=\"md\"\u003eAC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3459\" data-end=\"3502\"\u003e\n\u003ctd data-start=\"3459\" data-end=\"3480\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"3480\" data-end=\"3502\" data-col-size=\"md\"\u003e570 × 470 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3503\" data-end=\"3526\"\u003e\n\u003ctd data-start=\"3503\" data-end=\"3518\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3518\" data-end=\"3526\" data-col-size=\"md\"\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3527\" data-end=\"3550\"\u003e\n\u003ctd data-start=\"3527\" data-end=\"3538\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"3538\" data-end=\"3550\" data-col-size=\"md\"\u003e90275020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3552\" data-end=\"3569\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3571\" data-end=\"3601\"\u003eThe RFM100CFR can be used for:\u003c\/p\u003e\n\u003cul data-start=\"3603\" data-end=\"4028\"\u003e\n\u003cli data-section-id=\"12if0s3\" data-start=\"3603\" data-end=\"3633\"\u003eRefractive index measurement\u003c\/li\u003e\n\u003cli data-section-id=\"htfrib\" data-start=\"3634\" data-end=\"3652\"\u003eBrix measurement\u003c\/li\u003e\n\u003cli data-section-id=\"116z53t\" data-start=\"3653\" data-end=\"3683\"\u003eSugar concentration analysis\u003c\/li\u003e\n\u003cli data-section-id=\"13giyv1\" data-start=\"3684\" data-end=\"3751\"\u003eGlucose-related concentration measurements using suitable methods\u003c\/li\u003e\n\u003cli data-section-id=\"11fc4za\" data-start=\"3752\" data-end=\"3780\"\u003eFood and beverage analysis\u003c\/li\u003e\n\u003cli data-section-id=\"17kuc3i\" data-start=\"3781\" data-end=\"3817\"\u003ePharmaceutical laboratory analysis\u003c\/li\u003e\n\u003cli data-section-id=\"e12fix\" data-start=\"3818\" data-end=\"3847\"\u003eChemical laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"kh6azt\" data-start=\"3848\" data-end=\"3874\"\u003eResearch and development\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3875\" data-end=\"3905\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"robnqi\" data-start=\"3906\" data-end=\"3957\"\u003eConcentration analysis of suitable liquid samples\u003c\/li\u003e\n\u003cli data-section-id=\"gnjevh\" data-start=\"3958\" data-end=\"4028\"\u003eLaboratories requiring electronic records and controlled user access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"4030\" data-end=\"4047\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"4049\" data-end=\"4079\"\u003eThe RFM100CFR is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"4081\" data-end=\"4381\"\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"4081\" data-end=\"4110\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"4111\" data-end=\"4143\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"4144\" data-end=\"4167\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1t31nfa\" data-start=\"4168\" data-end=\"4191\"\u003eResearch institutions\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"4192\" data-end=\"4222\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"brvkbz\" data-start=\"4223\" data-end=\"4240\"\u003eR\u0026amp;D departments\u003c\/li\u003e\n\u003cli data-section-id=\"1kx6nxl\" data-start=\"4241\" data-end=\"4272\"\u003eContract testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"13p862z\" data-start=\"4273\" data-end=\"4311\"\u003eAcademic and analytical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ig5ir4\" data-start=\"4312\" data-end=\"4381\"\u003eLaboratories operating under controlled electronic-record workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"6748\" data-end=\"6758\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"eerewz\" dir=\"auto\" data-start=\"6760\" data-end=\"6819\"\u003e1. What is the refractive-index range of the RFM100CFR?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6820\" data-end=\"6868\"\u003eThe measurement range is \u003cstrong data-start=\"6845\" data-end=\"6867\"\u003e1.30000–1.70000 nD\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15miqf2\" dir=\"auto\" data-start=\"6870\" data-end=\"6917\"\u003e2. What is the refractive-index resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6918\" data-end=\"6961\"\u003eThe specified resolution is \u003cstrong data-start=\"6946\" data-end=\"6960\"\u003e0.00001 nD\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1sur2rb\" dir=\"auto\" data-start=\"6963\" data-end=\"7001\"\u003e3. Can the RFM100CFR measure Brix?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7002\" data-end=\"7059\"\u003eYes. It has a specified \u003cstrong data-start=\"7026\" data-end=\"7058\"\u003e0–100% °Brix measuring range\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1kna9z9\" dir=\"auto\" data-start=\"7061\" data-end=\"7096\"\u003e4. What is the Brix resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7097\" data-end=\"7130\"\u003eThe Brix resolution is \u003cstrong data-start=\"7120\" data-end=\"7129\"\u003e0.01%\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mambye\" dir=\"auto\" data-start=\"7132\" data-end=\"7187\"\u003e5. Does the refractometer have temperature control?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7188\" data-end=\"7251\"\u003eYes. It has an \u003cstrong data-start=\"7203\" data-end=\"7250\"\u003ein-built Peltier temperature-control system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1l696cx\" dir=\"auto\" data-start=\"7253\" data-end=\"7298\"\u003e6. What is the temperature-control range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7299\" data-end=\"7371\"\u003eThe specified control range is \u003cstrong data-start=\"7330\" data-end=\"7370\"\u003e5°C to 85°C at 20°C room temperature\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hn6viz\" dir=\"auto\" data-start=\"7373\" data-end=\"7414\"\u003e7. What type of display does it have?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7415\" data-end=\"7466\"\u003eThe RFM100CFR has an \u003cstrong data-start=\"7436\" data-end=\"7465\"\u003e8-inch colour touchscreen\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1pwluap\" dir=\"auto\" data-start=\"7468\" data-end=\"7511\"\u003e8. Does it require a separate computer?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7512\" data-end=\"7643\"\u003eNo. The instrument has a \u003cstrong data-start=\"7537\" data-end=\"7587\"\u003eWindows operating system and built-in software\u003c\/strong\u003e, so a separate PC is not required for normal operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"14gxg1c\" dir=\"auto\" data-start=\"7645\" data-end=\"7691\"\u003e9. How much internal storage is available?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7692\" data-end=\"7739\"\u003eThe instrument has \u003cstrong data-start=\"7711\" data-end=\"7738\"\u003e16GB of internal memory\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nz7ka4\" dir=\"auto\" data-start=\"7741\" data-end=\"7787\"\u003e10. Does it support electronic signatures?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7788\" data-end=\"7870\"\u003eYes. The specifications include \u003cstrong data-start=\"7820\" data-end=\"7869\"\u003eelectronic signatures and password management\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1exy3zh\" dir=\"auto\" data-start=\"7872\" data-end=\"7922\"\u003e11. How many measurement methods are built in?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7923\" data-end=\"7984\"\u003eThe instrument has \u003cstrong data-start=\"7942\" data-end=\"7983\"\u003e12 built-in measurement modes\/methods\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1kznuom\" dir=\"auto\" data-start=\"7986\" data-end=\"8013\"\u003e12. What prism is used?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8014\" data-end=\"8059\"\u003eThe RFM100CFR uses a \u003cstrong data-start=\"8035\" data-end=\"8058\"\u003esapphire-type prism\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":67547152122153,"sku":"RFM100CFR","price":619599.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/RFM100CFR_Clean_White_Background.png?v=1790589750","url":"https:\/\/www.labmart.in\/products\/labmart-rfm100cfr-automatic-digital-refractometer","provider":"Labmart.in","version":"1.0","type":"link"}