{"product_id":"labmart-rcb620t-refrigerated-circulating-bath","title":"Refrigerated Circulating Bath RCB620T","description":"\u003cp dir=\"auto\" data-start=\"147\" data-end=\"529\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"151\" data-end=\"200\"\u003eLabmart RCB620T Refrigerated Circulating Bath\u003c\/strong\u003e is a horizontal temperature-control system designed especially for viscometers and other laboratory instruments requiring controlled circulating liquid temperature. It provides a \u003cstrong data-start=\"380\" data-end=\"528\"\u003e–20°C to 100°C temperature range, ±0.05°C accuracy, 0.01°C resolution, 6L bath capacity, 6 L\/min circulation flow and microprocessor PID control\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"566\" data-end=\"585\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"587\" data-end=\"956\"\u003eThe \u003cstrong data-start=\"591\" data-end=\"632\"\u003eRCB620T Refrigerated Circulating Bath\u003c\/strong\u003e is a temperature-controlled circulating bath with a horizontal configuration specifically designed for applications where controlled liquid temperature is required. Its horizontal design allows a \u003cstrong data-start=\"829\" data-end=\"865\"\u003eviscometer to be attached on top\u003c\/strong\u003e, making it particularly suitable for viscosity measurements requiring temperature control.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"958\" data-end=\"1223\"\u003eThe system uses \u003cstrong data-start=\"974\" data-end=\"1037\"\u003eair-cooled compressor refrigeration with R-134A refrigerant\u003c\/strong\u003e, a PT100 temperature sensor and microprocessor-based PID temperature control. It supports both \u003cstrong data-start=\"1133\" data-end=\"1175\"\u003einternal and external pump circulation\u003c\/strong\u003e with a specified pump flow rate of \u003cstrong data-start=\"1211\" data-end=\"1222\"\u003e6 L\/min\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1225\" data-end=\"1439\"\u003eThe 6-litre bath features a stainless-steel inner tank, touchscreen operation, overheat protection and a water-level alarm. The supplied design also incorporates fast cooling, low noise and low vibration operation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1441\" data-end=\"1467\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1469\" data-end=\"2044\"\u003e\n\u003cli data-section-id=\"4mqd0g\" data-start=\"1469\" data-end=\"1507\"\u003e\u003cstrong data-start=\"1471\" data-end=\"1507\"\u003e–20°C to 100°C temperature range\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"rgsexs\" data-start=\"1508\" data-end=\"1542\"\u003e\u003cstrong data-start=\"1510\" data-end=\"1542\"\u003e±0.05°C temperature accuracy\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"pdii40\" data-start=\"1543\" data-end=\"1574\"\u003e\u003cstrong data-start=\"1545\" data-end=\"1574\"\u003e0.01°C display resolution\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"14jd8c2\" data-start=\"1575\" data-end=\"1615\"\u003eMicroprocessor PID temperature control\u003c\/li\u003e\n\u003cli data-section-id=\"1j5pw1r\" data-start=\"1616\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1618\" data-end=\"1644\"\u003e6 L\/min pump flow rate\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1cmu4x5\" data-start=\"1645\" data-end=\"1672\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1672\"\u003e6L bath tank capacity\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"mcb1mu\" data-start=\"1673\" data-end=\"1708\"\u003eInternal and external circulation\u003c\/li\u003e\n\u003cli data-section-id=\"9cq7zh\" data-start=\"1709\" data-end=\"1746\"\u003eAir-cooled compressor refrigeration\u003c\/li\u003e\n\u003cli data-section-id=\"6kpk1t\" data-start=\"1747\" data-end=\"1767\"\u003eR-134A refrigerant\u003c\/li\u003e\n\u003cli data-section-id=\"oct61z\" data-start=\"1768\" data-end=\"1794\"\u003ePT100 temperature sensor\u003c\/li\u003e\n\u003cli data-section-id=\"1mg6ngb\" data-start=\"1795\" data-end=\"1816\"\u003eTouchscreen display\u003c\/li\u003e\n\u003cli data-section-id=\"kcoj1b\" data-start=\"1817\" data-end=\"1883\"\u003eHorizontal design specifically suited to viscometer applications\u003c\/li\u003e\n\u003cli data-section-id=\"1pxvag\" data-start=\"1884\" data-end=\"1912\"\u003eStainless-steel inner tank\u003c\/li\u003e\n\u003cli data-section-id=\"1y8efzx\" data-start=\"1913\" data-end=\"1934\"\u003eOverheat protection\u003c\/li\u003e\n\u003cli data-section-id=\"1cv7mmt\" data-start=\"1935\" data-end=\"1954\"\u003eWater-level alarm\u003c\/li\u003e\n\u003cli data-section-id=\"vf9kej\" data-start=\"1955\" data-end=\"1992\"\u003eProgrammable temperature controller\u003c\/li\u003e\n\u003cli data-section-id=\"1j2fjpj\" data-start=\"1993\" data-end=\"2007\"\u003eFast cooling\u003c\/li\u003e\n\u003cli data-section-id=\"12d4zrx\" data-start=\"2008\" data-end=\"2044\"\u003eLow-noise, low-vibration operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2046\" data-end=\"2075\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2077\" data-end=\"2978\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2077\" data-end=\"2104\"\u003e\n\u003ctr data-start=\"2077\" data-end=\"2104\"\u003e\n\u003cth data-start=\"2077\" data-end=\"2093\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2093\" data-end=\"2104\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eRCB620T\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2115\" data-end=\"2978\"\u003e\n\u003ctr data-start=\"2115\" data-end=\"2163\"\u003e\n\u003ctd data-start=\"2115\" data-end=\"2130\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2130\" data-end=\"2163\" data-col-size=\"sm\"\u003eRefrigerated Circulating Bath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2164\" data-end=\"2183\"\u003e\n\u003ctd data-start=\"2164\" data-end=\"2172\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2172\" data-end=\"2183\" data-col-size=\"sm\"\u003eRCB620T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2184\" data-end=\"2203\"\u003e\n\u003ctd data-start=\"2184\" data-end=\"2192\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2192\" data-end=\"2203\" data-col-size=\"sm\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2204\" data-end=\"2234\"\u003e\n\u003ctd data-start=\"2204\" data-end=\"2220\" data-col-size=\"sm\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd data-start=\"2220\" data-end=\"2234\" data-col-size=\"sm\"\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2235\" data-end=\"2286\"\u003e\n\u003ctd data-start=\"2235\" data-end=\"2256\" data-col-size=\"sm\"\u003eApplication Design\u003c\/td\u003e\n\u003ctd data-start=\"2256\" data-end=\"2286\" data-col-size=\"sm\"\u003eSpecialized for Viscometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2287\" data-end=\"2325\"\u003e\n\u003ctd data-start=\"2287\" data-end=\"2307\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2307\" data-end=\"2325\" data-col-size=\"sm\"\u003e–20°C to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2326\" data-end=\"2369\"\u003e\n\u003ctd data-start=\"2326\" data-end=\"2359\" data-col-size=\"sm\"\u003eTemperature Display Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2359\" data-end=\"2369\" data-col-size=\"sm\"\u003e0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2370\" data-end=\"2404\"\u003e\n\u003ctd data-start=\"2370\" data-end=\"2393\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2393\" data-end=\"2404\" data-col-size=\"sm\"\u003e±0.05°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2405\" data-end=\"2449\"\u003e\n\u003ctd data-start=\"2405\" data-end=\"2427\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2427\" data-end=\"2449\" data-col-size=\"sm\"\u003eMicroprocessor PID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2450\" data-end=\"2475\"\u003e\n\u003ctd data-start=\"2450\" data-end=\"2460\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2460\" data-end=\"2475\" data-col-size=\"sm\"\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2476\" data-end=\"2531\"\u003e\n\u003ctd data-start=\"2476\" data-end=\"2492\" data-col-size=\"sm\"\u003eRefrigeration\u003c\/td\u003e\n\u003ctd data-start=\"2492\" data-end=\"2531\" data-col-size=\"sm\"\u003eAir-cooled compressor refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2532\" data-end=\"2556\"\u003e\n\u003ctd data-start=\"2532\" data-end=\"2546\" data-col-size=\"sm\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd data-start=\"2546\" data-end=\"2556\" data-col-size=\"sm\"\u003eR-134A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2557\" data-end=\"2599\"\u003e\n\u003ctd data-start=\"2557\" data-end=\"2576\" data-col-size=\"sm\"\u003ePump Circulation\u003c\/td\u003e\n\u003ctd data-start=\"2576\" data-end=\"2599\" data-col-size=\"sm\"\u003eInternal \u0026amp; External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2600\" data-end=\"2630\"\u003e\n\u003ctd data-start=\"2600\" data-end=\"2621\" data-col-size=\"sm\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd data-start=\"2621\" data-end=\"2630\" data-col-size=\"sm\"\u003ePT100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2631\" data-end=\"2659\"\u003e\n\u003ctd data-start=\"2631\" data-end=\"2648\" data-col-size=\"sm\"\u003ePump Flow Rate\u003c\/td\u003e\n\u003ctd data-start=\"2648\" data-end=\"2659\" data-col-size=\"sm\"\u003e6 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2660\" data-end=\"2687\"\u003e\n\u003ctd data-start=\"2660\" data-end=\"2681\" data-col-size=\"sm\"\u003eBath Tank Capacity\u003c\/td\u003e\n\u003ctd data-start=\"2681\" data-end=\"2687\" data-col-size=\"sm\"\u003e6L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2688\" data-end=\"2734\"\u003e\n\u003ctd data-start=\"2688\" data-end=\"2712\" data-col-size=\"sm\"\u003eTank Size (L × W × D)\u003c\/td\u003e\n\u003ctd data-start=\"2712\" data-end=\"2734\" data-col-size=\"sm\"\u003e350 × 165 × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2735\" data-end=\"2769\"\u003e\n\u003ctd data-start=\"2735\" data-end=\"2750\" data-col-size=\"sm\"\u003eBath Opening\u003c\/td\u003e\n\u003ctd data-start=\"2750\" data-end=\"2769\" data-col-size=\"sm\"\u003e110 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2770\" data-end=\"2793\"\u003e\n\u003ctd data-start=\"2770\" data-end=\"2783\" data-col-size=\"sm\"\u003eBath Depth\u003c\/td\u003e\n\u003ctd data-start=\"2783\" data-end=\"2793\" data-col-size=\"sm\"\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2794\" data-end=\"2835\"\u003e\n\u003ctd data-start=\"2794\" data-end=\"2816\" data-col-size=\"sm\"\u003eInner Tank Material\u003c\/td\u003e\n\u003ctd data-start=\"2816\" data-end=\"2835\" data-col-size=\"sm\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2836\" data-end=\"2885\"\u003e\n\u003ctd data-start=\"2836\" data-end=\"2856\" data-col-size=\"sm\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd data-start=\"2856\" data-end=\"2885\" data-col-size=\"sm\"\u003eAdaptor, AC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2886\" data-end=\"2929\"\u003e\n\u003ctd data-start=\"2886\" data-end=\"2907\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2907\" data-end=\"2929\" data-col-size=\"sm\"\u003e535 × 485 × 560 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2930\" data-end=\"2954\"\u003e\n\u003ctd data-start=\"2930\" data-end=\"2945\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"2945\" data-end=\"2954\" data-col-size=\"sm\"\u003e35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2955\" data-end=\"2978\"\u003e\n\u003ctd data-start=\"2955\" data-end=\"2966\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"2966\" data-end=\"2978\" data-col-size=\"sm\"\u003e84198990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"2980\" data-end=\"2997\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"2999\" data-end=\"3081\"\u003eThe RCB620T can be used for temperature maintenance and controlled circulation in:\u003c\/p\u003e\n\u003cul data-start=\"3083\" data-end=\"3326\"\u003e\n\u003cli data-section-id=\"cbxcsw\" data-start=\"3083\" data-end=\"3096\"\u003eViscometers\u003c\/li\u003e\n\u003cli data-section-id=\"1j35ob4\" data-start=\"3097\" data-end=\"3117\"\u003eSpectrophotometers\u003c\/li\u003e\n\u003cli data-section-id=\"46x8hl\" data-start=\"3118\" data-end=\"3132\"\u003ePolarimeters\u003c\/li\u003e\n\u003cli data-section-id=\"13375je\" data-start=\"3133\" data-end=\"3149\"\u003eRefractometers\u003c\/li\u003e\n\u003cli data-section-id=\"cqep69\" data-start=\"3150\" data-end=\"3175\"\u003eElectrophoresis systems\u003c\/li\u003e\n\u003cli data-section-id=\"lnnhw5\" data-start=\"3176\" data-end=\"3196\"\u003eFermentation tanks\u003c\/li\u003e\n\u003cli data-section-id=\"1o1zpqn\" data-start=\"3197\" data-end=\"3217\"\u003eRotary evaporators\u003c\/li\u003e\n\u003cli data-section-id=\"12olbca\" data-start=\"3218\" data-end=\"3243\"\u003eChromatographic columns\u003c\/li\u003e\n\u003cli data-section-id=\"bklr38\" data-start=\"3244\" data-end=\"3326\"\u003eOther laboratory equipment requiring external temperature-controlled circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3328\" data-end=\"3345\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3347\" data-end=\"3375\"\u003eThe RCB620T is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3377\" data-end=\"3707\"\u003e\n\u003cli data-section-id=\"pyoths\" data-start=\"3377\" data-end=\"3413\"\u003eViscosity measurement laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3414\" data-end=\"3443\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3444\" data-end=\"3467\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"3468\" data-end=\"3500\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"fov9jg\" data-start=\"3501\" data-end=\"3540\"\u003eResearch and development laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3541\" data-end=\"3571\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1btma4l\" data-start=\"3572\" data-end=\"3602\"\u003eInstrumentation laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1f8big7\" data-start=\"3603\" data-end=\"3641\"\u003eAcademic and university laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"12e3rm0\" data-start=\"3642\" data-end=\"3707\"\u003eLaboratories using temperature-sensitive analytical instruments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"6608\" data-end=\"6618\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"37q9b4\" dir=\"auto\" data-start=\"6620\" data-end=\"6656\"\u003e1. What is the RCB620T used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6658\" data-end=\"6869\"\u003eThe RCB620T is a \u003cstrong data-start=\"6675\" data-end=\"6748\"\u003erefrigerated circulating bath for maintaining controlled temperatures\u003c\/strong\u003e and can be connected to laboratory instruments such as viscometers, refractometers, polarimeters and rotary evaporators.\u003c\/p\u003e\n\u003ch3 data-section-id=\"72mjhb\" dir=\"auto\" data-start=\"6871\" data-end=\"6908\"\u003e2. What is the temperature range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6910\" data-end=\"6954\"\u003eThe temperature range is \u003cstrong data-start=\"6935\" data-end=\"6953\"\u003e–20°C to 100°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t3el24\" dir=\"auto\" data-start=\"6956\" data-end=\"6996\"\u003e3. What is the temperature accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6998\" data-end=\"7048\"\u003eThe specified temperature accuracy is \u003cstrong data-start=\"7036\" data-end=\"7047\"\u003e±0.05°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qdjvhk\" dir=\"auto\" data-start=\"7050\" data-end=\"7092\"\u003e4. What is the temperature resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7094\" data-end=\"7131\"\u003eThe display resolution is \u003cstrong data-start=\"7120\" data-end=\"7130\"\u003e0.01°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2h7pq8\" dir=\"auto\" data-start=\"7133\" data-end=\"7166\"\u003e5. What is the bath capacity?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7168\" data-end=\"7207\"\u003eThe bath tank capacity is \u003cstrong data-start=\"7194\" data-end=\"7206\"\u003e6 litres\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"enormv\" dir=\"auto\" data-start=\"7209\" data-end=\"7250\"\u003e6. What is the circulation flow rate?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7252\" data-end=\"7296\"\u003eThe specified pump flow rate is \u003cstrong data-start=\"7284\" data-end=\"7295\"\u003e6 L\/min\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ccunyn\" dir=\"auto\" data-start=\"7298\" data-end=\"7350\"\u003e7. Can the RCB620T be connected to a viscometer?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7352\" data-end=\"7467\"\u003eYes. The RCB620T is specifically described as a \u003cstrong data-start=\"7400\" data-end=\"7466\"\u003ehorizontal model specialized for attaching a viscometer on top\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"46dlvm\" dir=\"auto\" data-start=\"7469\" data-end=\"7513\"\u003e8. Does it support external circulation?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7515\" data-end=\"7576\"\u003eYes. The pump provides \u003cstrong data-start=\"7538\" data-end=\"7575\"\u003einternal and external circulation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ksqy16\" dir=\"auto\" data-start=\"7578\" data-end=\"7627\"\u003e9. What type of refrigeration system is used?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7629\" data-end=\"7715\"\u003eIt uses \u003cstrong data-start=\"7637\" data-end=\"7686\"\u003eair-cooled refrigeration through a compressor\u003c\/strong\u003e with \u003cstrong data-start=\"7692\" data-end=\"7714\"\u003eR-134A refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1f7ixob\" dir=\"auto\" data-start=\"7717\" data-end=\"7757\"\u003e10. What temperature sensor is used?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7759\" data-end=\"7805\"\u003eThe specified temperature sensor is \u003cstrong data-start=\"7795\" data-end=\"7804\"\u003ePT100\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"480sip\" dir=\"auto\" data-start=\"7807\" data-end=\"7853\"\u003e11. Does the RCB620T have safety features?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7855\" data-end=\"7929\"\u003eYes. It includes \u003cstrong data-start=\"7872\" data-end=\"7928\"\u003eoverheat protection and a water-level alarm function\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"xicvb6\" dir=\"auto\" data-start=\"7931\" data-end=\"7968\"\u003e12. What liquids are recommended?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7970\" data-end=\"8141\"\u003eThe supplied specifications identify alcohol for temperatures of \u003cstrong data-start=\"8035\" data-end=\"8052\"\u003e5°C and below\u003c\/strong\u003e, pure water for \u003cstrong data-start=\"8069\" data-end=\"8084\"\u003e5°C to 85°C\u003c\/strong\u003e, and a \u003cstrong data-start=\"8092\" data-end=\"8140\"\u003e15% glycerin-water solution for 85°C to 95°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52642589344041,"sku":"RCB620T","price":102299.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/rs_w_720_cg_true.webp?v=1770941232","url":"https:\/\/www.labmart.in\/products\/labmart-rcb620t-refrigerated-circulating-bath","provider":"Labmart.in","version":"1.0","type":"link"}