{"product_id":"labmart-rcb1020t-refrigerated-circulating-bath","title":"Refrigerated Circulating Bath RCB1020T","description":"\u003cp dir=\"auto\" data-start=\"141\" data-end=\"528\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"145\" data-end=\"195\"\u003eLabmart RCB1020T Refrigerated Circulating Bath\u003c\/strong\u003e is a temperature-controlled laboratory circulation system with a \u003cstrong data-start=\"261\" data-end=\"297\"\u003e–20°C to 100°C temperature range\u003c\/strong\u003e, 10L bath capacity, PT100 temperature sensor, microprocessor PID control and touchscreen operation. It provides \u003cstrong data-start=\"410\" data-end=\"431\"\u003e8 L\/min pump flow\u003c\/strong\u003e, internal and external circulation, air-cooled compressor refrigeration and overheat protection.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"530\" data-end=\"563\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"565\" data-end=\"584\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"586\" data-end=\"775\"\u003eThe \u003cstrong data-start=\"590\" data-end=\"632\"\u003eRCB1020T Refrigerated Circulating Bath\u003c\/strong\u003e is designed to provide controlled-temperature liquid circulation for laboratory instruments and processes requiring stable heating or cooling.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"777\" data-end=\"1029\"\u003eThe system offers a \u003cstrong data-start=\"797\" data-end=\"841\"\u003e–20°C to 100°C temperature control range\u003c\/strong\u003e, with \u003cstrong data-start=\"848\" data-end=\"877\"\u003e0.01°C display resolution\u003c\/strong\u003e and \u003cstrong data-start=\"882\" data-end=\"914\"\u003e±0.05°C temperature accuracy\u003c\/strong\u003e. Temperature regulation is managed through a \u003cstrong data-start=\"960\" data-end=\"997\"\u003emicroprocessor PID control system\u003c\/strong\u003e and a PT100 temperature sensor.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1031\" data-end=\"1236\"\u003eThe 10L stainless-steel bath incorporates \u003cstrong data-start=\"1073\" data-end=\"1110\"\u003einternal and external circulation\u003c\/strong\u003e, with an \u003cstrong data-start=\"1120\" data-end=\"1146\"\u003e8 L\/min pump flow rate\u003c\/strong\u003e. Refrigeration is provided through an air-cooled compressor using \u003cstrong data-start=\"1213\" data-end=\"1235\"\u003eR-134A refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1238\" data-end=\"1440\"\u003eThe catalogue identifies applications with \u003cstrong data-start=\"1281\" data-end=\"1439\"\u003efermentation tanks, spectrophotometers, rotary evaporators, polarimeters, refractometers, viscometers, electrophoresis systems and chromatographic columns\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1442\" data-end=\"1468\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1470\" data-end=\"2126\"\u003e\n\u003cli data-section-id=\"4mqd0g\" data-start=\"1470\" data-end=\"1508\"\u003e\u003cstrong data-start=\"1472\" data-end=\"1508\"\u003e–20°C to 100°C temperature range\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"186gary\" data-start=\"1509\" data-end=\"1532\"\u003e\u003cstrong data-start=\"1511\" data-end=\"1532\"\u003e10L bath capacity\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"ftjpuk\" data-start=\"1533\" data-end=\"1576\"\u003e\u003cstrong data-start=\"1535\" data-end=\"1576\"\u003e0.01°C temperature display resolution\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"rgsexs\" data-start=\"1577\" data-end=\"1611\"\u003e\u003cstrong data-start=\"1579\" data-end=\"1611\"\u003e±0.05°C temperature accuracy\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"14jd8c2\" data-start=\"1612\" data-end=\"1652\"\u003eMicroprocessor PID temperature control\u003c\/li\u003e\n\u003cli data-section-id=\"oct61z\" data-start=\"1653\" data-end=\"1679\"\u003ePT100 temperature sensor\u003c\/li\u003e\n\u003cli data-section-id=\"1mg6ngb\" data-start=\"1680\" data-end=\"1701\"\u003eTouchscreen display\u003c\/li\u003e\n\u003cli data-section-id=\"9cq7zh\" data-start=\"1702\" data-end=\"1739\"\u003eAir-cooled compressor refrigeration\u003c\/li\u003e\n\u003cli data-section-id=\"6kpk1t\" data-start=\"1740\" data-end=\"1760\"\u003eR-134A refrigerant\u003c\/li\u003e\n\u003cli data-section-id=\"mcb1mu\" data-start=\"1761\" data-end=\"1796\"\u003eInternal and external circulation\u003c\/li\u003e\n\u003cli data-section-id=\"18smtgx\" data-start=\"1797\" data-end=\"1825\"\u003e\u003cstrong data-start=\"1799\" data-end=\"1825\"\u003e8 L\/min pump flow rate\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1pxvag\" data-start=\"1826\" data-end=\"1854\"\u003eStainless-steel inner tank\u003c\/li\u003e\n\u003cli data-section-id=\"9n61vb\" data-start=\"1855\" data-end=\"1883\"\u003eWater-level alarm function\u003c\/li\u003e\n\u003cli data-section-id=\"1y8efzx\" data-start=\"1884\" data-end=\"1905\"\u003eOverheat protection\u003c\/li\u003e\n\u003cli data-section-id=\"1j2fjpj\" data-start=\"1906\" data-end=\"1920\"\u003eFast cooling\u003c\/li\u003e\n\u003cli data-section-id=\"1a3zhzu\" data-start=\"1921\" data-end=\"1960\"\u003eLow-noise and low-vibration operation\u003c\/li\u003e\n\u003cli data-section-id=\"vf9kej\" data-start=\"1961\" data-end=\"1998\"\u003eProgrammable temperature controller\u003c\/li\u003e\n\u003cli data-section-id=\"ojz9kg\" data-start=\"1999\" data-end=\"2043\"\u003eFolding handles on both sides for movement\u003c\/li\u003e\n\u003cli data-section-id=\"1mllwef\" data-start=\"2044\" data-end=\"2065\"\u003eStainless-steel lid\u003c\/li\u003e\n\u003cli data-section-id=\"1lhjghm\" data-start=\"2066\" data-end=\"2126\"\u003eSuitable for connection to multiple laboratory instruments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2128\" data-end=\"2157\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2159\" data-end=\"3042\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2159\" data-end=\"2187\"\u003e\n\u003ctr data-start=\"2159\" data-end=\"2187\"\u003e\n\u003cth data-start=\"2159\" data-end=\"2175\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2175\" data-end=\"2187\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eRCB1020T\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2198\" data-end=\"3042\"\u003e\n\u003ctr data-start=\"2198\" data-end=\"2246\"\u003e\n\u003ctd data-start=\"2198\" data-end=\"2213\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2213\" data-end=\"2246\" data-col-size=\"sm\"\u003eRefrigerated Circulating Bath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2247\" data-end=\"2267\"\u003e\n\u003ctd data-start=\"2247\" data-end=\"2255\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2255\" data-end=\"2267\" data-col-size=\"sm\"\u003eRCB1020T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2268\" data-end=\"2287\"\u003e\n\u003ctd data-start=\"2268\" data-end=\"2276\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2276\" data-end=\"2287\" data-col-size=\"sm\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2288\" data-end=\"2326\"\u003e\n\u003ctd data-start=\"2288\" data-end=\"2308\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2308\" data-end=\"2326\" data-col-size=\"sm\"\u003e–20°C to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2327\" data-end=\"2370\"\u003e\n\u003ctd data-start=\"2327\" data-end=\"2360\" data-col-size=\"sm\"\u003eTemperature Display Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2360\" data-end=\"2370\" data-col-size=\"sm\"\u003e0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2371\" data-end=\"2405\"\u003e\n\u003ctd data-start=\"2371\" data-end=\"2394\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2394\" data-end=\"2405\" data-col-size=\"sm\"\u003e±0.05°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2406\" data-end=\"2450\"\u003e\n\u003ctd data-start=\"2406\" data-end=\"2428\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2428\" data-end=\"2450\" data-col-size=\"sm\"\u003eMicroprocessor PID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2451\" data-end=\"2476\"\u003e\n\u003ctd data-start=\"2451\" data-end=\"2461\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2461\" data-end=\"2476\" data-col-size=\"sm\"\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2477\" data-end=\"2507\"\u003e\n\u003ctd data-start=\"2477\" data-end=\"2498\" data-col-size=\"sm\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd data-start=\"2498\" data-end=\"2507\" data-col-size=\"sm\"\u003ePT100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2508\" data-end=\"2563\"\u003e\n\u003ctd data-start=\"2508\" data-end=\"2524\" data-col-size=\"sm\"\u003eRefrigeration\u003c\/td\u003e\n\u003ctd data-start=\"2524\" data-end=\"2563\" data-col-size=\"sm\"\u003eAir-cooled compressor refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2564\" data-end=\"2588\"\u003e\n\u003ctd data-start=\"2564\" data-end=\"2578\" data-col-size=\"sm\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd data-start=\"2578\" data-end=\"2588\" data-col-size=\"sm\"\u003eR-134A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2589\" data-end=\"2631\"\u003e\n\u003ctd data-start=\"2589\" data-end=\"2608\" data-col-size=\"sm\"\u003ePump Circulation\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2608\" data-end=\"2631\"\u003eInternal \u0026amp; External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2632\" data-end=\"2660\"\u003e\n\u003ctd data-start=\"2632\" data-end=\"2649\" data-col-size=\"sm\"\u003ePump Flow Rate\u003c\/td\u003e\n\u003ctd data-start=\"2649\" data-end=\"2660\" data-col-size=\"sm\"\u003e8 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2661\" data-end=\"2690\"\u003e\n\u003ctd data-start=\"2661\" data-end=\"2682\" data-col-size=\"sm\"\u003eBath Tank Capacity\u003c\/td\u003e\n\u003ctd data-start=\"2682\" data-end=\"2690\" data-col-size=\"sm\"\u003e10 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2691\" data-end=\"2725\"\u003e\n\u003ctd data-start=\"2691\" data-end=\"2703\" data-col-size=\"sm\"\u003eTank Size\u003c\/td\u003e\n\u003ctd data-start=\"2703\" data-end=\"2725\" data-col-size=\"sm\"\u003e270 × 200 × 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2726\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2726\" data-end=\"2741\" data-col-size=\"sm\"\u003eBath Opening\u003c\/td\u003e\n\u003ctd data-start=\"2741\" data-end=\"2757\" data-col-size=\"sm\"\u003e180 × 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2781\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2771\" data-col-size=\"sm\"\u003eBath Depth\u003c\/td\u003e\n\u003ctd data-start=\"2771\" data-end=\"2781\" data-col-size=\"sm\"\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2782\" data-end=\"2823\"\u003e\n\u003ctd data-start=\"2782\" data-end=\"2804\" data-col-size=\"sm\"\u003eInner Tank Material\u003c\/td\u003e\n\u003ctd data-start=\"2804\" data-end=\"2823\" data-col-size=\"sm\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2824\" data-end=\"2868\"\u003e\n\u003ctd data-start=\"2824\" data-end=\"2849\" data-col-size=\"sm\"\u003eCirculation \u0026amp; Drainage\u003c\/td\u003e\n\u003ctd data-start=\"2849\" data-end=\"2868\" data-col-size=\"sm\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2869\" data-end=\"2902\"\u003e\n\u003ctd data-start=\"2869\" data-end=\"2884\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2884\" data-end=\"2902\" data-col-size=\"sm\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2903\" data-end=\"2949\"\u003e\n\u003ctd data-start=\"2903\" data-end=\"2927\" data-col-size=\"sm\"\u003eInstrument Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2927\" data-end=\"2949\" data-col-size=\"sm\"\u003e440 × 300 × 510 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2950\" data-end=\"2993\"\u003e\n\u003ctd data-start=\"2950\" data-end=\"2971\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2971\" data-end=\"2993\" data-col-size=\"sm\"\u003e535 × 380 × 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2994\" data-end=\"3018\"\u003e\n\u003ctd data-start=\"2994\" data-end=\"3009\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3009\" data-end=\"3018\" data-col-size=\"sm\"\u003e41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3019\" data-end=\"3042\"\u003e\n\u003ctd data-start=\"3019\" data-end=\"3030\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"3030\" data-end=\"3042\" data-col-size=\"sm\"\u003e84198990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3044\" data-end=\"3061\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3063\" data-end=\"3137\"\u003eThe RCB1020T can be used for temperature maintenance and circulation with:\u003c\/p\u003e\n\u003cul data-start=\"3139\" data-end=\"3362\"\u003e\n\u003cli data-section-id=\"lnnhw5\" data-start=\"3139\" data-end=\"3159\"\u003eFermentation tanks\u003c\/li\u003e\n\u003cli data-section-id=\"1j35ob4\" data-start=\"3160\" data-end=\"3180\"\u003eSpectrophotometers\u003c\/li\u003e\n\u003cli data-section-id=\"1o1zpqn\" data-start=\"3181\" data-end=\"3201\"\u003eRotary evaporators\u003c\/li\u003e\n\u003cli data-section-id=\"46x8hl\" data-start=\"3202\" data-end=\"3216\"\u003ePolarimeters\u003c\/li\u003e\n\u003cli data-section-id=\"13375je\" data-start=\"3217\" data-end=\"3233\"\u003eRefractometers\u003c\/li\u003e\n\u003cli data-section-id=\"cbxcsw\" data-start=\"3234\" data-end=\"3247\"\u003eViscometers\u003c\/li\u003e\n\u003cli data-section-id=\"cqep69\" data-start=\"3248\" data-end=\"3273\"\u003eElectrophoresis systems\u003c\/li\u003e\n\u003cli data-section-id=\"12olbca\" data-start=\"3274\" data-end=\"3299\"\u003eChromatographic columns\u003c\/li\u003e\n\u003cli data-section-id=\"1ri5ntg\" data-start=\"3300\" data-end=\"3362\"\u003eLaboratory processes requiring controlled liquid temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3364\" data-end=\"3381\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3383\" data-end=\"3412\"\u003eThe RCB1020T is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3414\" data-end=\"3740\"\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"3414\" data-end=\"3437\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3438\" data-end=\"3467\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3468\" data-end=\"3491\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1or0uhb\" data-start=\"3492\" data-end=\"3520\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1xly2en\" data-start=\"3521\" data-end=\"3540\"\u003eFood laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3541\" data-end=\"3571\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1qoxw4d\" data-start=\"3572\" data-end=\"3590\"\u003eR\u0026amp;D laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1a3eblz\" data-start=\"3591\" data-end=\"3629\"\u003eUniversity and academic laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"3vm1rm\" data-start=\"3630\" data-end=\"3675\"\u003eInstrument temperature-control applications\u003c\/li\u003e\n\u003cli data-section-id=\"ztz3tp\" data-start=\"3676\" data-end=\"3740\"\u003eLaboratory processes requiring heating and cooling circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"6437\" data-end=\"6447\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1a9wn1z\" dir=\"auto\" data-start=\"6449\" data-end=\"6486\"\u003e1. What is the RCB1020T used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6488\" data-end=\"6643\"\u003eThe RCB1020T is a refrigerated circulating bath used to maintain and circulate liquid at a controlled temperature for laboratory instruments and processes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"72mjhb\" dir=\"auto\" data-start=\"6645\" data-end=\"6682\"\u003e2. What is the temperature range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6684\" data-end=\"6748\"\u003eThe RCB1020T provides a temperature range of \u003cstrong data-start=\"6729\" data-end=\"6747\"\u003e–20°C to 100°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"8fc5mu\" dir=\"auto\" data-start=\"6750\" data-end=\"6783\"\u003e3. What is the bath capacity?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6785\" data-end=\"6825\"\u003eThe bath tank capacity is \u003cstrong data-start=\"6811\" data-end=\"6824\"\u003e10 litres\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e65nln\" dir=\"auto\" data-start=\"6827\" data-end=\"6867\"\u003e4. What is the temperature accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6869\" data-end=\"6919\"\u003eThe specified temperature accuracy is \u003cstrong data-start=\"6907\" data-end=\"6918\"\u003e±0.05°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11s47o3\" dir=\"auto\" data-start=\"6921\" data-end=\"6971\"\u003e5. What is the temperature display resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6973\" data-end=\"7010\"\u003eThe display resolution is \u003cstrong data-start=\"6999\" data-end=\"7009\"\u003e0.01°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5lgijh\" dir=\"auto\" data-start=\"7012\" data-end=\"7059\"\u003e6. What type of temperature sensor is used?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7061\" data-end=\"7110\"\u003eThe RCB1020T uses a \u003cstrong data-start=\"7081\" data-end=\"7109\"\u003ePT100 temperature sensor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1r9s90z\" dir=\"auto\" data-start=\"7112\" data-end=\"7164\"\u003e7. What type of temperature control does it use?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7166\" data-end=\"7217\"\u003eIt uses \u003cstrong data-start=\"7174\" data-end=\"7216\"\u003emicroprocessor PID temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1x794cu\" dir=\"auto\" data-start=\"7219\" data-end=\"7253\"\u003e8. What is the pump flow rate?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7255\" data-end=\"7299\"\u003eThe specified pump flow rate is \u003cstrong data-start=\"7287\" data-end=\"7298\"\u003e8 L\/min\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"tgd2pa\" dir=\"auto\" data-start=\"7301\" data-end=\"7354\"\u003e9. Can the RCB1020T provide external circulation?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7356\" data-end=\"7424\"\u003eYes. The system supports \u003cstrong data-start=\"7381\" data-end=\"7423\"\u003einternal and external pump circulation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"pj2sdf\" dir=\"auto\" data-start=\"7426\" data-end=\"7468\"\u003e10. What refrigeration system is used?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7470\" data-end=\"7556\"\u003eThe RCB1020T uses \u003cstrong data-start=\"7488\" data-end=\"7527\"\u003eair-cooled compressor refrigeration\u003c\/strong\u003e with \u003cstrong data-start=\"7533\" data-end=\"7555\"\u003eR-134A refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"qb5wjh\" dir=\"auto\" data-start=\"7558\" data-end=\"7618\"\u003e11. Which laboratory instruments can it be connected to?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7620\" data-end=\"7822\"\u003eThe catalogue identifies applications with \u003cstrong data-start=\"7663\" data-end=\"7821\"\u003efermentation tanks, spectrophotometers, rotary evaporators, polarimeters, refractometers, viscometers, electrophoresis systems and chromatographic columns\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v3xy6x\" dir=\"auto\" data-start=\"7824\" data-end=\"7867\"\u003e12. What is supplied with the RCB1020T?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7869\" data-end=\"8063\"\u003eThe standard accessories include the \u003cstrong data-start=\"7906\" data-end=\"8062\"\u003emain instrument, stainless-steel lid, circulating tube, thermal sleeve for circulating tube, fuse, power cord, instructional manual and test certificate\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52642698690857,"sku":"RCB1020T","price":102399.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/rs_w_508_cg_true_c4e7210f-60ae-474c-9e29-0695ed7184ef.webp?v=1770941271","url":"https:\/\/www.labmart.in\/products\/labmart-rcb1020t-refrigerated-circulating-bath","provider":"Labmart.in","version":"1.0","type":"link"}