{"product_id":"labmart-pbh40t-paddle-blender-homogenizer","title":"Paddle Blender Homogenizer PBH40T","description":"\u003cp dir=\"auto\" data-start=\"155\" data-end=\"628\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"159\" data-end=\"204\"\u003eLabmart PBH40T Paddle Blender Homogenizer\u003c\/strong\u003e is designed for microbiological sample preparation, particularly for extracting and washing intact microorganisms into solution. It handles \u003cstrong data-start=\"345\" data-end=\"365\"\u003e4–400 mL samples\u003c\/strong\u003e, provides adjustable paddle flapping speed, programmable operation with \u003cstrong data-start=\"438\" data-end=\"459\"\u003e8 stored programs\u003c\/strong\u003e, a \u003cstrong data-start=\"463\" data-end=\"487\"\u003e4.3-inch touchscreen\u003c\/strong\u003e, adjustable flapping distance and an automatic stop function. The PBH40T is the \u003cstrong data-start=\"568\" data-end=\"591\"\u003enon-heating, non-UV\u003c\/strong\u003e version of the PBH40T\/PBH80T series.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"630\" data-end=\"663\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"665\" data-end=\"684\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"686\" data-end=\"954\"\u003eThe \u003cstrong data-start=\"690\" data-end=\"727\"\u003ePBH40T Paddle Blender Homogenizer\u003c\/strong\u003e is a laboratory sample-preparation instrument designed primarily for microbiological applications where samples need to be blended and homogenized in a sterile bag without direct contact between the sample and the homogenizer.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"956\" data-end=\"1252\"\u003eThe system is specified for sample volumes from \u003cstrong data-start=\"1004\" data-end=\"1022\"\u003e4 mL to 400 mL\u003c\/strong\u003e and uses paddle movement to process samples inside a sterile homogeneous bag. The adjustable flapping speed ranges from \u003cstrong data-start=\"1143\" data-end=\"1186\"\u003e3.0 to 12.0 squeezing cycles per second\u003c\/strong\u003e, while the flapping distance can be adjusted from \u003cstrong data-start=\"1237\" data-end=\"1251\"\u003e0 to 50 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1254\" data-end=\"1512\"\u003eThe PBH40T features a \u003cstrong data-start=\"1276\" data-end=\"1300\"\u003e4.3-inch touchscreen\u003c\/strong\u003e, programmable speed and time settings, storage for \u003cstrong data-start=\"1352\" data-end=\"1366\"\u003e8 programs\u003c\/strong\u003e, a transparent viewing window and an automatic stop function. It is constructed with stainless steel and an anticorrosive plastic-sprayed finish.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1514\" data-end=\"1593\"\u003eUnlike the PBH80T, the \u003cstrong data-start=\"1537\" data-end=\"1592\"\u003ePBH40T does not include heating or UV sterilization\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1595\" data-end=\"1621\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1623\" data-end=\"2282\"\u003e\n\u003cli data-section-id=\"jgn9g2\" data-start=\"1623\" data-end=\"1654\"\u003eSample capacity: \u003cstrong data-start=\"1642\" data-end=\"1654\"\u003e4–400 mL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9wh2xf\" data-start=\"1655\" data-end=\"1689\"\u003e\u003cstrong data-start=\"1657\" data-end=\"1689\"\u003e4.3-inch touchscreen display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"ppjn2z\" data-start=\"1690\" data-end=\"1755\"\u003eAdjustable flapping speed: \u003cstrong data-start=\"1719\" data-end=\"1755\"\u003e3.0–12.0 squeezing cycles\/second\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zhq3u3\" data-start=\"1756\" data-end=\"1799\"\u003eAdjustable flapping distance: \u003cstrong data-start=\"1788\" data-end=\"1799\"\u003e0–50 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1uzaxtb\" data-start=\"1800\" data-end=\"1836\"\u003e\u003cstrong data-start=\"1802\" data-end=\"1836\"\u003e8 programmable speed\/time sets\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"wp59a2\" data-start=\"1837\" data-end=\"1854\"\u003eTiming function\u003c\/li\u003e\n\u003cli data-section-id=\"nwg5hr\" data-start=\"1855\" data-end=\"1880\"\u003eAutomatic stop function\u003c\/li\u003e\n\u003cli data-section-id=\"1205fo3\" data-start=\"1881\" data-end=\"1908\"\u003eAlarm and pause functions\u003c\/li\u003e\n\u003cli data-section-id=\"sge74n\" data-start=\"1909\" data-end=\"1958\"\u003eTransparent glass window for sample observation\u003c\/li\u003e\n\u003cli data-section-id=\"17bj6oe\" data-start=\"1959\" data-end=\"2009\"\u003eNo direct contact between sample and homogenizer\u003c\/li\u003e\n\u003cli data-section-id=\"1hyx708\" data-start=\"2010\" data-end=\"2076\"\u003eStainless-steel construction with anticorrosive plastic spraying\u003c\/li\u003e\n\u003cli data-section-id=\"a6wf0i\" data-start=\"2077\" data-end=\"2116\"\u003eDesigned for sterile homogeneous bags\u003c\/li\u003e\n\u003cli data-section-id=\"1drxpyx\" data-start=\"2117\" data-end=\"2159\"\u003eSuitable for bags up to \u003cstrong data-start=\"2143\" data-end=\"2159\"\u003e170 × 300 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1i4ibtx\" data-start=\"2160\" data-end=\"2190\"\u003ePaddle size: \u003cstrong data-start=\"2175\" data-end=\"2190\"\u003e145 × 85 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k32me9\" data-start=\"2191\" data-end=\"2217\"\u003eAC 220V \/ 50Hz operation\u003c\/li\u003e\n\u003cli data-section-id=\"6hqnzk\" data-start=\"2218\" data-end=\"2282\"\u003e\n\u003cstrong data-start=\"2220\" data-end=\"2254\"\u003eNo heating or UV sterilization\u003c\/strong\u003e in the PBH40T configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2284\" data-end=\"2313\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2315\" data-end=\"3239\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2315\" data-end=\"2341\"\u003e\n\u003ctr data-start=\"2315\" data-end=\"2341\"\u003e\n\u003cth data-start=\"2315\" data-end=\"2331\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2331\" data-end=\"2341\" data-col-size=\"md\" class=\"last:pe-10\"\u003ePBH40T\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2352\" data-end=\"3239\"\u003e\n\u003ctr data-start=\"2352\" data-end=\"2397\"\u003e\n\u003ctd data-start=\"2352\" data-end=\"2367\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2367\" data-end=\"2397\"\u003ePaddle Blender Homogenizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2398\" data-end=\"2416\"\u003e\n\u003ctd data-start=\"2398\" data-end=\"2406\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2406\" data-end=\"2416\"\u003ePBH40T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2417\" data-end=\"2436\"\u003e\n\u003ctd data-start=\"2417\" data-end=\"2425\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2425\" data-end=\"2436\" data-col-size=\"md\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2437\" data-end=\"2500\"\u003e\n\u003ctd data-start=\"2437\" data-end=\"2459\" data-col-size=\"sm\"\u003ePrimary Application\u003c\/td\u003e\n\u003ctd data-start=\"2459\" data-end=\"2500\" data-col-size=\"md\"\u003eMicrobiological sample homogenization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2501\" data-end=\"2534\"\u003e\n\u003ctd data-start=\"2501\" data-end=\"2519\" data-col-size=\"sm\"\u003eSample Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2519\" data-end=\"2534\"\u003e4 mL–400 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2535\" data-end=\"2551\"\u003e\n\u003ctd data-start=\"2535\" data-end=\"2545\" data-col-size=\"sm\"\u003eHeating\u003c\/td\u003e\n\u003ctd data-start=\"2545\" data-end=\"2551\" data-col-size=\"md\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2552\" data-end=\"2577\"\u003e\n\u003ctd data-start=\"2552\" data-end=\"2571\" data-col-size=\"sm\"\u003eUV Sterilization\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2571\" data-end=\"2577\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2578\" data-end=\"2642\"\u003e\n\u003ctd data-start=\"2578\" data-end=\"2606\" data-col-size=\"sm\"\u003eFlapping \/ Slapping Speed\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2606\" data-end=\"2642\"\u003e3.0–12.0 squeezing cycles\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2643\" data-end=\"2684\"\u003e\n\u003ctd data-start=\"2643\" data-end=\"2674\" data-col-size=\"sm\"\u003eProgrammable Speed\/Time Sets\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2674\" data-end=\"2684\"\u003e8 sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2685\" data-end=\"2727\"\u003e\n\u003ctd data-start=\"2685\" data-end=\"2716\" data-col-size=\"sm\"\u003eAdjustable Flapping Distance\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2716\" data-end=\"2727\"\u003e0–50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2728\" data-end=\"2758\"\u003e\n\u003ctd data-start=\"2728\" data-end=\"2738\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2738\" data-end=\"2758\" data-col-size=\"md\"\u003e4.3\" Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2759\" data-end=\"2783\"\u003e\n\u003ctd data-start=\"2759\" data-end=\"2776\" data-col-size=\"sm\"\u003eTiming Setting\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2776\" data-end=\"2783\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2784\" data-end=\"2808\"\u003e\n\u003ctd data-start=\"2784\" data-end=\"2801\" data-col-size=\"sm\"\u003eAlarm Function\u003c\/td\u003e\n\u003ctd data-start=\"2801\" data-end=\"2808\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2809\" data-end=\"2833\"\u003e\n\u003ctd data-start=\"2809\" data-end=\"2826\" data-col-size=\"sm\"\u003ePause Function\u003c\/td\u003e\n\u003ctd data-start=\"2826\" data-end=\"2833\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2834\" data-end=\"2858\"\u003e\n\u003ctd data-start=\"2834\" data-end=\"2851\" data-col-size=\"sm\"\u003eAutomatic Stop\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2851\" data-end=\"2858\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2859\" data-end=\"2912\"\u003e\n\u003ctd data-start=\"2859\" data-end=\"2884\" data-col-size=\"sm\"\u003eSample\/Bag Observation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2884\" data-end=\"2912\"\u003eTransparent glass window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2913\" data-end=\"2960\"\u003e\n\u003ctd data-start=\"2913\" data-end=\"2944\" data-col-size=\"sm\"\u003eSterile Homogeneous Bag Size\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2944\" data-end=\"2960\"\u003e170 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2961\" data-end=\"2990\"\u003e\n\u003ctd data-start=\"2961\" data-end=\"2975\" data-col-size=\"sm\"\u003ePaddle Size\u003c\/td\u003e\n\u003ctd data-start=\"2975\" data-end=\"2990\" data-col-size=\"md\"\u003e145 × 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2991\" data-end=\"3041\"\u003e\n\u003ctd data-start=\"2991\" data-end=\"3020\" data-col-size=\"sm\"\u003eSample-Homogenizer Contact\u003c\/td\u003e\n\u003ctd data-start=\"3020\" data-end=\"3041\" data-col-size=\"md\"\u003eNo direct contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3042\" data-end=\"3112\"\u003e\n\u003ctd data-start=\"3042\" data-end=\"3057\" data-col-size=\"sm\"\u003eConstruction\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3057\" data-end=\"3112\"\u003eStainless steel with anticorrosive plastic spraying\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3113\" data-end=\"3146\"\u003e\n\u003ctd data-start=\"3113\" data-end=\"3128\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3128\" data-end=\"3146\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3147\" data-end=\"3190\"\u003e\n\u003ctd data-start=\"3147\" data-end=\"3168\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3168\" data-end=\"3190\"\u003e530 × 330 × 455 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3191\" data-end=\"3215\"\u003e\n\u003ctd data-start=\"3191\" data-end=\"3206\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3206\" data-end=\"3215\"\u003e25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3216\" data-end=\"3239\"\u003e\n\u003ctd data-start=\"3216\" data-end=\"3227\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"3227\" data-end=\"3239\" data-col-size=\"md\"\u003e84798200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3241\" data-end=\"3258\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3260\" data-end=\"3297\"\u003eThe PBH40T is primarily suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3299\" data-end=\"3614\"\u003e\n\u003cli data-section-id=\"162mlhw\" data-start=\"3299\" data-end=\"3332\"\u003eMicrobiology sample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"m2h7pr\" data-start=\"3333\" data-end=\"3384\"\u003eExtraction of intact microorganisms into solution\u003c\/li\u003e\n\u003cli data-section-id=\"1n85vdz\" data-start=\"3385\" data-end=\"3433\"\u003eWashing of intact microorganisms into solution\u003c\/li\u003e\n\u003cli data-section-id=\"1pcjfkp\" data-start=\"3434\" data-end=\"3461\"\u003eFood testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"hej2ib\" data-start=\"3462\" data-end=\"3490\"\u003eEnvironmental microbiology\u003c\/li\u003e\n\u003cli data-section-id=\"1hbsl66\" data-start=\"3491\" data-end=\"3514\"\u003eLife-science research\u003c\/li\u003e\n\u003cli data-section-id=\"14tk5t6\" data-start=\"3515\" data-end=\"3549\"\u003eLaboratory sample homogenization\u003c\/li\u003e\n\u003cli data-section-id=\"1icv6og\" data-start=\"3550\" data-end=\"3614\"\u003ePreparation of samples for subsequent microbiological analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3616\" data-end=\"3633\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3635\" data-end=\"3662\"\u003eThe PBH40T is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3664\" data-end=\"3935\"\u003e\n\u003cli data-section-id=\"4s9vta\" data-start=\"3664\" data-end=\"3691\"\u003eMicrobiology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1pcjfkp\" data-start=\"3692\" data-end=\"3719\"\u003eFood testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1iu5xdh\" data-start=\"3720\" data-end=\"3748\"\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"i0tgkr\" data-start=\"3749\" data-end=\"3785\"\u003eLife-science research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1or0uhb\" data-start=\"3786\" data-end=\"3814\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3815\" data-end=\"3845\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1iigjch\" data-start=\"3846\" data-end=\"3878\"\u003eAcademic research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ym8m58\" data-start=\"3879\" data-end=\"3935\"\u003eLaboratories requiring bag-based sample homogenization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"6332\" data-end=\"6342\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"hz3ncp\" dir=\"auto\" data-start=\"6344\" data-end=\"6379\"\u003e1. What is the PBH40T used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6381\" data-end=\"6529\"\u003eThe PBH40T is primarily used for \u003cstrong data-start=\"6414\" data-end=\"6455\"\u003emicrobiological sample homogenization\u003c\/strong\u003e, including extraction and washing of intact microorganisms into solution.\u003c\/p\u003e\n\u003ch3 data-section-id=\"25ianp\" dir=\"auto\" data-start=\"6531\" data-end=\"6580\"\u003e2. What sample volume can the PBH40T process?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6582\" data-end=\"6627\"\u003eThe specified capacity is \u003cstrong data-start=\"6608\" data-end=\"6626\"\u003e4 mL to 400 mL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"79oct\" dir=\"auto\" data-start=\"6629\" data-end=\"6680\"\u003e3. Does the PBH40T directly contact the sample?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6682\" data-end=\"6764\"\u003eNo. The source specifies \u003cstrong data-start=\"6707\" data-end=\"6763\"\u003eno direct contact between the sample and homogenizer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"6qrx8h\" dir=\"auto\" data-start=\"6766\" data-end=\"6798\"\u003e4. What type of bag is used?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6800\" data-end=\"6860\"\u003eThe instrument is designed for \u003cstrong data-start=\"6831\" data-end=\"6859\"\u003esterile homogeneous bags\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"y89x6w\" dir=\"auto\" data-start=\"6862\" data-end=\"6900\"\u003e5. What is the specified bag size?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6902\" data-end=\"6965\"\u003eThe specified sterile homogeneous bag size is \u003cstrong data-start=\"6948\" data-end=\"6964\"\u003e170 × 300 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1kokeij\" dir=\"auto\" data-start=\"6967\" data-end=\"7007\"\u003e6. What is the flapping speed range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7009\" data-end=\"7072\"\u003eThe flapping speed is \u003cstrong data-start=\"7031\" data-end=\"7071\"\u003e3.0–12.0 squeezing cycles per second\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1hd7fie\" dir=\"auto\" data-start=\"7074\" data-end=\"7119\"\u003e7. Can the flapping distance be adjusted?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7121\" data-end=\"7184\"\u003eYes. The flapping distance can be adjusted from \u003cstrong data-start=\"7169\" data-end=\"7183\"\u003e0 to 50 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1g5y55f\" dir=\"auto\" data-start=\"7186\" data-end=\"7225\"\u003e8. How many programs can be stored?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7227\" data-end=\"7283\"\u003eThe PBH40T can store \u003cstrong data-start=\"7248\" data-end=\"7282\"\u003e8 programmable speed\/time sets\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xfa1fm\" dir=\"auto\" data-start=\"7285\" data-end=\"7321\"\u003e9. Does the PBH40T have heating?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7323\" data-end=\"7383\"\u003eNo. \u003cstrong data-start=\"7327\" data-end=\"7354\"\u003eHeating is not provided\u003c\/strong\u003e in the PBH40T configuration.\u003c\/p\u003e\n\u003ch3 data-section-id=\"76dayi\" dir=\"auto\" data-start=\"7385\" data-end=\"7431\"\u003e10. Does the PBH40T have UV sterilization?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7433\" data-end=\"7502\"\u003eNo. \u003cstrong data-start=\"7437\" data-end=\"7473\"\u003eUV sterilization is not provided\u003c\/strong\u003e in the PBH40T configuration.\u003c\/p\u003e\n\u003ch3 data-section-id=\"y1a9bx\" dir=\"auto\" data-start=\"7504\" data-end=\"7558\"\u003e11. What type of display does the instrument have?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7560\" data-end=\"7602\"\u003eIt has a \u003cstrong data-start=\"7569\" data-end=\"7601\"\u003e4.3-inch touchscreen display\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1e18j52\" dir=\"auto\" data-start=\"7604\" data-end=\"7652\"\u003e12. Does it have an automatic stop function?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7654\" data-end=\"7748\"\u003eYes. The PBH40T includes an \u003cstrong data-start=\"7682\" data-end=\"7709\"\u003eautomatic stop function\u003c\/strong\u003e, along with alarm and pause functions.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":67552408535337,"sku":"PBH40T","price":85599.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/PBH40T_Clean_White_Background.png?v=1790682609","url":"https:\/\/www.labmart.in\/products\/labmart-pbh40t-paddle-blender-homogenizer","provider":"Labmart.in","version":"1.0","type":"link"}