{"product_id":"labmart-mpa8a-melting-point-apparatus","title":"MPA8A Melting Point Apparatus","description":"\u003cp dir=\"auto\" data-start=\"151\" data-end=\"545\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"155\" data-end=\"188\"\u003eMPA8A Melting Point Apparatus\u003c\/strong\u003e is an automatic laboratory instrument for determining the melting point of solid substances. It offers a \u003cstrong data-start=\"294\" data-end=\"337\"\u003emeasurement range from RT +5°C to 400°C\u003c\/strong\u003e, 0.1°C resolution, automatic melting curve recording, PID \u0026amp; PWM temperature control, and a 7-inch touchscreen display. It is suitable for pharmaceutical, chemical, dye, perfume, and organic crystal analysis.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"582\" data-end=\"601\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"603\" data-end=\"896\"\u003eThe \u003cstrong data-start=\"607\" data-end=\"648\"\u003eLabmart MPA8A Melting Point Apparatus\u003c\/strong\u003e is designed for controlled and automated determination of the melting point of solid samples contained in capillary tubes. The instrument automatically records the melting process and calculates the average of the initial and final melting points.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"898\" data-end=\"1158\"\u003eWith a \u003cstrong data-start=\"905\" data-end=\"935\"\u003e7-inch touchscreen display\u003c\/strong\u003e, automatic measurement mode, programmable linear heating rates, and PID \u0026amp; PWM temperature control, the MPA8A provides a convenient platform for routine melting-point analysis in laboratory and quality-control environments.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1160\" data-end=\"1277\"\u003eThe apparatus operates from \u003cstrong data-start=\"1188\" data-end=\"1225\"\u003eroom temperature +5°C up to 400°C\u003c\/strong\u003e and provides a temperature resolution of \u003cstrong data-start=\"1267\" data-end=\"1276\"\u003e0.1°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1279\" data-end=\"1305\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1307\" data-end=\"2101\"\u003e\n\u003cli data-section-id=\"1nkxiec\" data-start=\"1307\" data-end=\"1388\"\u003e\n\u003cstrong data-start=\"1309\" data-end=\"1347\"\u003eRT +5°C to 400°C measurement range\u003c\/strong\u003e for a broad range of laboratory samples.\u003c\/li\u003e\n\u003cli data-section-id=\"sxrmdc\" data-start=\"1389\" data-end=\"1463\"\u003e\n\u003cstrong data-start=\"1391\" data-end=\"1423\"\u003e0.1°C temperature resolution\u003c\/strong\u003e for detailed melting-point observation.\u003c\/li\u003e\n\u003cli data-section-id=\"1nqnib4\" data-start=\"1464\" data-end=\"1522\"\u003e\n\u003cstrong data-start=\"1466\" data-end=\"1496\"\u003eAutomatic measurement mode\u003c\/strong\u003e for simplified operation.\u003c\/li\u003e\n\u003cli data-section-id=\"1mbot5e\" data-start=\"1523\" data-end=\"1577\"\u003e\n\u003cstrong data-start=\"1525\" data-end=\"1550\"\u003e8 measurement methods\u003c\/strong\u003e for method-based analysis.\u003c\/li\u003e\n\u003cli data-section-id=\"buzvsl\" data-start=\"1578\" data-end=\"1637\"\u003e\n\u003cstrong data-start=\"1580\" data-end=\"1613\"\u003ePID \u0026amp; PWM temperature control\u003c\/strong\u003e for controlled heating.\u003c\/li\u003e\n\u003cli data-section-id=\"fivy00\" data-start=\"1638\" data-end=\"1694\"\u003e\n\u003cstrong data-start=\"1640\" data-end=\"1677\"\u003eAutomatic melting curve recording\u003c\/strong\u003e during analysis.\u003c\/li\u003e\n\u003cli data-section-id=\"ydxz72\" data-start=\"1695\" data-end=\"1767\"\u003e\n\u003cstrong data-start=\"1697\" data-end=\"1766\"\u003eAutomatic calculation of average initial and final melting points\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"1s7v19r\" data-start=\"1768\" data-end=\"1830\"\u003e\n\u003cstrong data-start=\"1770\" data-end=\"1804\"\u003e7-inch touchscreen LCD display\u003c\/strong\u003e for convenient operation.\u003c\/li\u003e\n\u003cli data-section-id=\"qf2avq\" data-start=\"1831\" data-end=\"1895\"\u003e\n\u003cstrong data-start=\"1833\" data-end=\"1894\"\u003eAdjustable linear heating rate from 0.1°C\/min to 20°C\/min\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"iq6dj9\" data-start=\"1896\" data-end=\"1955\"\u003e\n\u003cstrong data-start=\"1898\" data-end=\"1923\"\u003e1000-set data storage\u003c\/strong\u003e for retaining measurement data.\u003c\/li\u003e\n\u003cli data-section-id=\"1n44p66\" data-start=\"1956\" data-end=\"2006\"\u003e\n\u003cstrong data-start=\"1958\" data-end=\"1987\"\u003eRS232C and USB interfaces\u003c\/strong\u003e for data transfer.\u003c\/li\u003e\n\u003cli data-section-id=\"1j5gj5s\" data-start=\"2007\" data-end=\"2037\"\u003eBuilt-in \u003cstrong data-start=\"2018\" data-end=\"2036\"\u003eclock function\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"chp6ru\" data-start=\"2038\" data-end=\"2101\"\u003eDesigned for \u003cstrong data-start=\"2053\" data-end=\"2100\"\u003ecapillary-based melting point determination\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2103\" data-end=\"2132\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2134\" data-end=\"3048\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2134\" data-end=\"2159\"\u003e\n\u003ctr data-start=\"2134\" data-end=\"2159\"\u003e\n\u003cth data-start=\"2134\" data-end=\"2150\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2150\" data-end=\"2159\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eMPA8A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2170\" data-end=\"3048\"\u003e\n\u003ctr data-start=\"2170\" data-end=\"2222\"\u003e\n\u003ctd data-start=\"2170\" data-end=\"2185\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2185\" data-end=\"2222\" data-col-size=\"sm\"\u003eAutomatic Melting Point Apparatus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2223\" data-end=\"2240\"\u003e\n\u003ctd data-start=\"2223\" data-end=\"2231\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2231\" data-end=\"2240\" data-col-size=\"sm\"\u003eMPA8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2241\" data-end=\"2281\"\u003e\n\u003ctd data-start=\"2241\" data-end=\"2261\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-start=\"2261\" data-end=\"2281\" data-col-size=\"sm\"\u003eRT +5°C to 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2282\" data-end=\"2314\"\u003e\n\u003ctd data-start=\"2282\" data-end=\"2301\" data-col-size=\"sm\"\u003eMeasurement Mode\u003c\/td\u003e\n\u003ctd data-start=\"2301\" data-end=\"2314\" data-col-size=\"sm\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2315\" data-end=\"2342\"\u003e\n\u003ctd data-start=\"2315\" data-end=\"2337\" data-col-size=\"sm\"\u003eMeasurement Methods\u003c\/td\u003e\n\u003ctd data-start=\"2337\" data-end=\"2342\" data-col-size=\"sm\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2343\" data-end=\"2365\"\u003e\n\u003ctd data-start=\"2343\" data-end=\"2356\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"2356\" data-end=\"2365\" data-col-size=\"sm\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2366\" data-end=\"2416\"\u003e\n\u003ctd data-start=\"2366\" data-end=\"2391\" data-col-size=\"sm\"\u003eLinear Heating-Up Rate\u003c\/td\u003e\n\u003ctd data-start=\"2391\" data-end=\"2416\" data-col-size=\"sm\"\u003e0.1°C\/min to 20°C\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2417\" data-end=\"2462\"\u003e\n\u003ctd data-start=\"2417\" data-end=\"2428\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"2428\" data-end=\"2462\" data-col-size=\"sm\"\u003e≤200°C: ±0.4°C; \u0026gt;200°C: ±0.7°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2463\" data-end=\"2517\"\u003e\n\u003ctd data-start=\"2463\" data-end=\"2479\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"2479\" data-end=\"2517\" data-col-size=\"sm\"\u003e0.3°C at heating rate of 1.0°C\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2518\" data-end=\"2554\"\u003e\n\u003ctd data-start=\"2518\" data-end=\"2546\" data-col-size=\"sm\"\u003eLinear Heating Rate Error\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2546\" data-end=\"2554\"\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2555\" data-end=\"2590\"\u003e\n\u003ctd data-start=\"2555\" data-end=\"2577\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2577\" data-end=\"2590\" data-col-size=\"sm\"\u003ePID \u0026amp; PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2591\" data-end=\"2620\"\u003e\n\u003ctd data-start=\"2591\" data-end=\"2615\" data-col-size=\"sm\"\u003eNumber of Capillaries\u003c\/td\u003e\n\u003ctd data-start=\"2615\" data-end=\"2620\" data-col-size=\"sm\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2621\" data-end=\"2659\"\u003e\n\u003ctd data-start=\"2621\" data-end=\"2648\" data-col-size=\"sm\"\u003eCapillary Outer Diameter\u003c\/td\u003e\n\u003ctd data-start=\"2648\" data-end=\"2659\" data-col-size=\"sm\"\u003eØ1.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2660\" data-end=\"2698\"\u003e\n\u003ctd data-start=\"2660\" data-end=\"2687\" data-col-size=\"sm\"\u003eCapillary Inner Diameter\u003c\/td\u003e\n\u003ctd data-start=\"2687\" data-end=\"2698\" data-col-size=\"sm\"\u003eØ1.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2699\" data-end=\"2727\"\u003e\n\u003ctd data-start=\"2699\" data-end=\"2718\" data-col-size=\"sm\"\u003eCapillary Length\u003c\/td\u003e\n\u003ctd data-start=\"2718\" data-end=\"2727\" data-col-size=\"sm\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2728\" data-end=\"2760\"\u003e\n\u003ctd data-start=\"2728\" data-end=\"2752\" data-col-size=\"sm\"\u003eSample Loading Height\u003c\/td\u003e\n\u003ctd data-start=\"2752\" data-end=\"2760\" data-col-size=\"sm\"\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2761\" data-end=\"2789\"\u003e\n\u003ctd data-start=\"2761\" data-end=\"2776\" data-col-size=\"sm\"\u003eData Storage\u003c\/td\u003e\n\u003ctd data-start=\"2776\" data-end=\"2789\" data-col-size=\"sm\"\u003e1000 sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2790\" data-end=\"2820\"\u003e\n\u003ctd data-start=\"2790\" data-end=\"2807\" data-col-size=\"sm\"\u003eClock Function\u003c\/td\u003e\n\u003ctd data-start=\"2807\" data-end=\"2820\" data-col-size=\"sm\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2821\" data-end=\"2853\"\u003e\n\u003ctd data-start=\"2821\" data-end=\"2831\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2831\" data-end=\"2853\" data-col-size=\"sm\"\u003e7-inch Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2854\" data-end=\"2896\"\u003e\n\u003ctd data-start=\"2854\" data-end=\"2880\" data-col-size=\"sm\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd data-start=\"2880\" data-end=\"2896\" data-col-size=\"sm\"\u003eRS232C \/ USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2897\" data-end=\"2935\"\u003e\n\u003ctd data-start=\"2897\" data-end=\"2919\" data-col-size=\"sm\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2919\" data-end=\"2935\" data-col-size=\"sm\"\u003e15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2936\" data-end=\"2971\"\u003e\n\u003ctd data-start=\"2936\" data-end=\"2951\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2951\" data-end=\"2971\" data-col-size=\"sm\"\u003eAC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2972\" data-end=\"3015\"\u003e\n\u003ctd data-start=\"2972\" data-end=\"2993\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2993\" data-end=\"3015\" data-col-size=\"sm\"\u003e500 × 445 × 330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3016\" data-end=\"3048\"\u003e\n\u003ctd data-start=\"3016\" data-end=\"3031\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3031\" data-end=\"3048\" data-col-size=\"sm\"\u003eApprox. 10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3050\" data-end=\"3067\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3069\" data-end=\"3126\"\u003eThe MPA8A is suitable for melting-point determination in:\u003c\/p\u003e\n\u003cul data-start=\"3128\" data-end=\"3423\"\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3128\" data-end=\"3157\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"lpiy3p\" data-start=\"3158\" data-end=\"3190\"\u003ePharmaceutical quality control\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3191\" data-end=\"3214\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1h0pawt\" data-start=\"3215\" data-end=\"3235\"\u003eDye-stuff analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1p82xzn\" data-start=\"3236\" data-end=\"3272\"\u003ePerfume and fragrance laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"8qvko7\" data-start=\"3273\" data-end=\"3299\"\u003eOrganic crystal analysis\u003c\/li\u003e\n\u003cli data-section-id=\"fov9jg\" data-start=\"3300\" data-end=\"3339\"\u003eResearch and development laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1sjvskl\" data-start=\"3340\" data-end=\"3381\"\u003eLaboratory quality-control applications\u003c\/li\u003e\n\u003cli data-section-id=\"1dm6bt\" data-start=\"3382\" data-end=\"3423\"\u003eEducational and analytical laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3425\" data-end=\"3442\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3444\" data-end=\"3570\"\u003eThe MPA8A is suitable for laboratories requiring automated melting-point determination of solid samples using capillary tubes.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3572\" data-end=\"3599\"\u003e\u003cstrong data-start=\"3572\" data-end=\"3599\"\u003eSuitable users include:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3601\" data-end=\"3803\"\u003e\n\u003cli data-section-id=\"oc8ob\" data-start=\"3601\" data-end=\"3631\"\u003ePharmaceutical manufacturers\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3632\" data-end=\"3655\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1t31nfa\" data-start=\"3656\" data-end=\"3679\"\u003eResearch institutions\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3680\" data-end=\"3710\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"brvkbz\" data-start=\"3711\" data-end=\"3728\"\u003eR\u0026amp;D departments\u003c\/li\u003e\n\u003cli data-section-id=\"tnvors\" data-start=\"3729\" data-end=\"3752\"\u003eAcademic laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"jpgyqj\" data-start=\"3753\" data-end=\"3775\"\u003eTesting laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"167fuah\" data-start=\"3776\" data-end=\"3803\"\u003eUniversities and colleges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"5744\" data-end=\"5754\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"17ppyq7\" dir=\"auto\" data-start=\"5756\" data-end=\"5806\"\u003e1. What is the measurement range of the MPA8A?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5807\" data-end=\"5853\"\u003eThe measurement range is \u003cstrong data-start=\"5832\" data-end=\"5852\"\u003eRT +5°C to 400°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"8fzvqm\" dir=\"auto\" data-start=\"5855\" data-end=\"5897\"\u003e2. What is the temperature resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5898\" data-end=\"5938\"\u003eThe temperature resolution is \u003cstrong data-start=\"5928\" data-end=\"5937\"\u003e0.1°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yhm5y7\" dir=\"auto\" data-start=\"5940\" data-end=\"5970\"\u003e3. Is the MPA8A automatic?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5971\" data-end=\"6029\"\u003eYes. The MPA8A operates in \u003cstrong data-start=\"5998\" data-end=\"6028\"\u003eautomatic measurement mode\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"170s516\" dir=\"auto\" data-start=\"6031\" data-end=\"6085\"\u003e4. How many capillaries can the MPA8A accommodate?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6086\" data-end=\"6137\"\u003eThe specified configuration uses \u003cstrong data-start=\"6119\" data-end=\"6136\"\u003eone capillary\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1434xnz\" dir=\"auto\" data-start=\"6139\" data-end=\"6178\"\u003e5. What capillary size is required?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6179\" data-end=\"6294\"\u003eThe specified capillary has an outer diameter of \u003cstrong data-start=\"6228\" data-end=\"6238\"\u003e1.4 mm\u003c\/strong\u003e, inner diameter of \u003cstrong data-start=\"6258\" data-end=\"6268\"\u003e1.0 mm\u003c\/strong\u003e, and length of \u003cstrong data-start=\"6284\" data-end=\"6293\"\u003e90 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ahgc83\" dir=\"auto\" data-start=\"6296\" data-end=\"6348\"\u003e6. Does the instrument record the melting curve?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6349\" data-end=\"6408\"\u003eYes. The MPA8A \u003cstrong data-start=\"6364\" data-end=\"6407\"\u003eautomatically records the melting curve\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mmvsfs\" dir=\"auto\" data-start=\"6410\" data-end=\"6476\"\u003e7. Can the MPA8A calculate melting-point values automatically?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6477\" data-end=\"6575\"\u003eYes. It can automatically calculate the \u003cstrong data-start=\"6517\" data-end=\"6574\"\u003eaverage value of the initial and final melting points\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"jvot98\" dir=\"auto\" data-start=\"6577\" data-end=\"6629\"\u003e8. What type of temperature control does it use?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6630\" data-end=\"6679\"\u003eThe MPA8A uses \u003cstrong data-start=\"6645\" data-end=\"6678\"\u003ePID \u0026amp; PWM temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1bdllb0\" dir=\"auto\" data-start=\"6681\" data-end=\"6722\"\u003e9. What heating rate can be selected?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6723\" data-end=\"6792\"\u003eThe linear heating-up rate can be set from \u003cstrong data-start=\"6766\" data-end=\"6791\"\u003e0.1°C\/min to 20°C\/min\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"vg4f9b\" dir=\"auto\" data-start=\"6794\" data-end=\"6842\"\u003e10. How much measurement data can be stored?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6843\" data-end=\"6896\"\u003eThe specified data-storage capacity is \u003cstrong data-start=\"6882\" data-end=\"6895\"\u003e1000 sets\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kzlkz3\" dir=\"auto\" data-start=\"6898\" data-end=\"6941\"\u003e11. Does it have computer connectivity?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6942\" data-end=\"7000\"\u003eYes. The apparatus provides \u003cstrong data-start=\"6970\" data-end=\"6999\"\u003eRS232C and USB interfaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1wb0q33\" dir=\"auto\" data-start=\"7002\" data-end=\"7044\"\u003e12. What type of display does it have?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7045\" data-end=\"7092\"\u003eThe MPA8A has a \u003cstrong data-start=\"7061\" data-end=\"7091\"\u003e7-inch touchscreen display\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":67546971898153,"sku":"MPA8A","price":184999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/MPA8A_Key_Features.png?v=1790578979","url":"https:\/\/www.labmart.in\/products\/labmart-mpa8a-melting-point-apparatus","provider":"Labmart.in","version":"1.0","type":"link"}