{"product_id":"labmart-mpa3p-portable-melting-point-apparatus","title":"Portable Melting Point Apparatus MPA3P","description":"\u003cp dir=\"auto\" data-start=\"138\" data-end=\"564\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"142\" data-end=\"184\"\u003eMPA3P Portable Melting Point Apparatus\u003c\/strong\u003e is a compact laboratory instrument for determining the melting point of solid substances using capillary tubes. It can process \u003cstrong data-start=\"312\" data-end=\"340\"\u003e3 samples simultaneously\u003c\/strong\u003e, features a touchscreen display, PID temperature control, adjustable heating rate from \u003cstrong data-start=\"428\" data-end=\"449\"\u003e0.1°C to 10°C\/min\u003c\/strong\u003e, and an optical lens for clear real-time observation of the melting process. \u003cspan class=\"contents\" data-content-reference-start=\"527\" data-content-reference-end=\"557\"\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"566\" data-end=\"599\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"601\" data-end=\"620\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"622\" data-end=\"867\"\u003eThe \u003cstrong data-start=\"626\" data-end=\"676\"\u003eLabmart MPA3P Portable Melting Point Apparatus\u003c\/strong\u003e is designed for melting-point determination under controlled and reproducible heating conditions. A sample is placed inside a capillary tube and heated while the melting process is observed.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"869\" data-end=\"1275\"\u003eIts compact format, touchscreen interface and ability to process \u003cstrong data-start=\"934\" data-end=\"968\"\u003ethree samples at the same time\u003c\/strong\u003e make it suitable for routine laboratory melting-point analysis. The instrument uses \u003cstrong data-start=\"1053\" data-end=\"1080\"\u003ePID temperature control\u003c\/strong\u003e and allows the heating rate to be adjusted between \u003cstrong data-start=\"1132\" data-end=\"1158\"\u003e0.1°C\/min and 10°C\/min\u003c\/strong\u003e. An optical lens provides clear, real-time observation of the melting process. \u003cspan class=\"contents\" data-content-reference-start=\"1231\" data-content-reference-end=\"1261\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1277\" data-end=\"1303\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1305\" data-end=\"1889\"\u003e\n\u003cli data-section-id=\"18hmn7\" data-start=\"1305\" data-end=\"1373\"\u003e\n\u003cstrong data-start=\"1307\" data-end=\"1343\"\u003ePortable melting point apparatus\u003c\/strong\u003e in a compact benchtop format.\u003c\/li\u003e\n\u003cli data-section-id=\"1noqab5\" data-start=\"1374\" data-end=\"1415\"\u003eProcesses \u003cstrong data-start=\"1386\" data-end=\"1414\"\u003e3 samples simultaneously\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"tpm09e\" data-start=\"1416\" data-end=\"1467\"\u003e\n\u003cstrong data-start=\"1418\" data-end=\"1441\"\u003eTouchscreen display\u003c\/strong\u003e for convenient operation.\u003c\/li\u003e\n\u003cli data-section-id=\"1fo9mzc\" data-start=\"1468\" data-end=\"1503\"\u003e\n\u003cstrong data-start=\"1470\" data-end=\"1502\"\u003e0.1°C temperature resolution\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"clivkg\" data-start=\"1504\" data-end=\"1534\"\u003e\n\u003cstrong data-start=\"1506\" data-end=\"1533\"\u003ePID temperature control\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"1ad1yvc\" data-start=\"1535\" data-end=\"1592\"\u003eAdjustable heating rate from \u003cstrong data-start=\"1566\" data-end=\"1591\"\u003e0.1°C\/min to 10°C\/min\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"woj58w\" data-start=\"1593\" data-end=\"1645\"\u003eOptical lens for \u003cstrong data-start=\"1612\" data-end=\"1644\"\u003eclear, real-time observation\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"54p8l5\" data-start=\"1646\" data-end=\"1692\"\u003e\n\u003cstrong data-start=\"1648\" data-end=\"1668\"\u003eRS232C interface\u003c\/strong\u003e for data communication.\u003c\/li\u003e\n\u003cli data-section-id=\"1ajf3pj\" data-start=\"1693\" data-end=\"1752\"\u003eDesigned for capillary-based melting-point determination.\u003c\/li\u003e\n\u003cli data-section-id=\"rkivf3\" data-start=\"1753\" data-end=\"1889\"\u003eSupplied with capillary tubes, power cord with adaptor, instruction manual and test certificate. \u003cspan class=\"contents\" data-content-reference-start=\"1838\" data-content-reference-end=\"1868\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"1891\" data-end=\"1920\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1922\" data-end=\"2741\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1922\" data-end=\"1947\"\u003e\n\u003ctr data-start=\"1922\" data-end=\"1947\"\u003e\n\u003cth data-start=\"1922\" data-end=\"1938\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1938\" data-end=\"1947\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eMPA3P\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1958\" data-end=\"2741\"\u003e\n\u003ctr data-start=\"1958\" data-end=\"2009\"\u003e\n\u003ctd data-start=\"1958\" data-end=\"1973\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"1973\" data-end=\"2009\" data-col-size=\"sm\"\u003ePortable Melting Point Apparatus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2010\" data-end=\"2027\"\u003e\n\u003ctd data-start=\"2010\" data-end=\"2018\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2018\" data-end=\"2027\" data-col-size=\"sm\"\u003eMPA3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2028\" data-end=\"2047\"\u003e\n\u003ctd data-start=\"2028\" data-end=\"2036\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2036\" data-end=\"2047\" data-col-size=\"sm\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2048\" data-end=\"2088\"\u003e\n\u003ctd data-start=\"2048\" data-end=\"2068\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2068\" data-end=\"2088\" data-col-size=\"sm\"\u003eRT +7°C to 320°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2089\" data-end=\"2111\"\u003e\n\u003ctd data-start=\"2089\" data-end=\"2102\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"2102\" data-end=\"2111\" data-col-size=\"sm\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2112\" data-end=\"2148\"\u003e\n\u003ctd data-start=\"2112\" data-end=\"2127\" data-col-size=\"sm\"\u003eHeating Rate\u003c\/td\u003e\n\u003ctd data-start=\"2127\" data-end=\"2148\" data-col-size=\"sm\"\u003e0.1°C to 10°C\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2149\" data-end=\"2178\"\u003e\n\u003ctd data-start=\"2149\" data-end=\"2171\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2171\" data-end=\"2178\" data-col-size=\"sm\"\u003ePID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2179\" data-end=\"2232\"\u003e\n\u003ctd data-start=\"2179\" data-end=\"2190\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"2190\" data-end=\"2232\" data-col-size=\"sm\"\u003e±0.4°C below 200°C; ±0.7°C above 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2233\" data-end=\"2259\"\u003e\n\u003ctd data-start=\"2233\" data-end=\"2249\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"2249\" data-end=\"2259\" data-col-size=\"sm\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2260\" data-end=\"2296\"\u003e\n\u003ctd data-start=\"2260\" data-end=\"2288\" data-col-size=\"sm\"\u003eLinear Heating Rate Error\u003c\/td\u003e\n\u003ctd data-start=\"2288\" data-end=\"2296\" data-col-size=\"sm\"\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2297\" data-end=\"2326\"\u003e\n\u003ctd data-start=\"2297\" data-end=\"2321\" data-col-size=\"sm\"\u003eNumber of Capillaries\u003c\/td\u003e\n\u003ctd data-start=\"2321\" data-end=\"2326\" data-col-size=\"sm\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2327\" data-end=\"2352\"\u003e\n\u003ctd data-start=\"2327\" data-end=\"2337\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2337\" data-end=\"2352\" data-col-size=\"sm\"\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2353\" data-end=\"2410\"\u003e\n\u003ctd data-start=\"2353\" data-end=\"2367\" data-col-size=\"sm\"\u003eObservation\u003c\/td\u003e\n\u003ctd data-start=\"2367\" data-end=\"2410\" data-col-size=\"sm\"\u003eOptical lens with real-time observation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2411\" data-end=\"2438\"\u003e\n\u003ctd data-start=\"2411\" data-end=\"2428\" data-col-size=\"sm\"\u003eData Interface\u003c\/td\u003e\n\u003ctd data-start=\"2428\" data-end=\"2438\" data-col-size=\"sm\"\u003eRS232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2439\" data-end=\"2477\"\u003e\n\u003ctd data-start=\"2439\" data-end=\"2466\" data-col-size=\"sm\"\u003eCapillary Outer Diameter\u003c\/td\u003e\n\u003ctd data-start=\"2466\" data-end=\"2477\" data-col-size=\"sm\"\u003eØ1.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2478\" data-end=\"2516\"\u003e\n\u003ctd data-start=\"2478\" data-end=\"2505\" data-col-size=\"sm\"\u003eCapillary Inner Diameter\u003c\/td\u003e\n\u003ctd data-start=\"2505\" data-end=\"2516\" data-col-size=\"sm\"\u003eØ1.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2517\" data-end=\"2533\"\u003e\n\u003ctd data-start=\"2517\" data-end=\"2525\" data-col-size=\"sm\"\u003ePower\u003c\/td\u003e\n\u003ctd data-start=\"2525\" data-end=\"2533\" data-col-size=\"sm\"\u003e100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2534\" data-end=\"2569\"\u003e\n\u003ctd data-start=\"2534\" data-end=\"2549\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2549\" data-end=\"2569\" data-col-size=\"sm\"\u003eAC 220V, 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2570\" data-end=\"2613\"\u003e\n\u003ctd data-start=\"2570\" data-end=\"2591\" data-col-size=\"sm\"\u003eMachine Dimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2591\" data-end=\"2613\"\u003e160 × 220 × 155 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2614\" data-end=\"2669\"\u003e\n\u003ctd data-start=\"2614\" data-end=\"2647\" data-col-size=\"sm\"\u003eOverall Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd data-start=\"2647\" data-end=\"2669\" data-col-size=\"sm\"\u003e250 × 250 × 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2670\" data-end=\"2693\"\u003e\n\u003ctd data-start=\"2670\" data-end=\"2683\" data-col-size=\"sm\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-start=\"2683\" data-end=\"2693\" data-col-size=\"sm\"\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2694\" data-end=\"2717\"\u003e\n\u003ctd data-start=\"2694\" data-end=\"2709\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"2709\" data-end=\"2717\" data-col-size=\"sm\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2718\" data-end=\"2741\"\u003e\n\u003ctd data-start=\"2718\" data-end=\"2729\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"2729\" data-end=\"2741\" data-col-size=\"sm\"\u003e90278090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"2743\" data-end=\"2975\"\u003eThe supplied specification table gives the temperature range as \u003cstrong data-start=\"2807\" data-end=\"2826\"\u003eRT+7°C to 320°C\u003c\/strong\u003e in the rendered catalogue image; the extracted text contains a formatting\/OCR artifact around the upper limit. \u003cspan class=\"contents\" data-content-reference-start=\"2917\" data-content-reference-end=\"2947\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"2977\" data-end=\"2994\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"2996\" data-end=\"3022\"\u003eThe MPA3P is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3024\" data-end=\"3286\"\u003e\n\u003cli data-section-id=\"17kuc3i\" data-start=\"3024\" data-end=\"3060\"\u003ePharmaceutical laboratory analysis\u003c\/li\u003e\n\u003cli data-section-id=\"e12fix\" data-start=\"3061\" data-end=\"3090\"\u003eChemical laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"kr6pwk\" data-start=\"3091\" data-end=\"3118\"\u003eOrganic compound analysis\u003c\/li\u003e\n\u003cli data-section-id=\"kh6azt\" data-start=\"3119\" data-end=\"3145\"\u003eResearch and development\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3146\" data-end=\"3176\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1rfrjx1\" data-start=\"3177\" data-end=\"3207\"\u003eAcademic laboratory teaching\u003c\/li\u003e\n\u003cli data-section-id=\"qhygwx\" data-start=\"3208\" data-end=\"3257\"\u003eMelting-point determination of solid substances\u003c\/li\u003e\n\u003cli data-section-id=\"1hum014\" data-start=\"3258\" data-end=\"3286\"\u003eRoutine analytical testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"3288\" data-end=\"3526\"\u003eThe catalogue describes melting-point determination as heating a sample under precise and reproducible conditions, with the sample contained in a capillary tube and the phase change observed visually. \u003cspan class=\"contents\" data-content-reference-start=\"3461\" data-content-reference-end=\"3491\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3528\" data-end=\"3545\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3547\" data-end=\"3573\"\u003eThe MPA3P is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3575\" data-end=\"3808\"\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3575\" data-end=\"3604\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3605\" data-end=\"3628\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"brvkbz\" data-start=\"3629\" data-end=\"3646\"\u003eR\u0026amp;D departments\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3647\" data-end=\"3677\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"jpgyqj\" data-start=\"3678\" data-end=\"3700\"\u003eTesting laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"nyl6ft\" data-start=\"3701\" data-end=\"3728\"\u003eColleges and universities\u003c\/li\u003e\n\u003cli data-section-id=\"1t31nfa\" data-start=\"3729\" data-end=\"3752\"\u003eResearch institutions\u003c\/li\u003e\n\u003cli data-section-id=\"1kcj48j\" data-start=\"3753\" data-end=\"3808\"\u003eLaboratories requiring a compact melting-point tester\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"5520\" data-end=\"5530\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"13tqq24\" dir=\"auto\" data-start=\"5532\" data-end=\"5566\"\u003e1. What is the MPA3P used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5567\" data-end=\"5658\"\u003eThe MPA3P is used to determine the melting point of solid substances using capillary tubes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e198xh\" dir=\"auto\" data-start=\"5660\" data-end=\"5706\"\u003e2. How many samples can be tested at once?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5707\" data-end=\"5762\"\u003eThe MPA3P can process \u003cstrong data-start=\"5729\" data-end=\"5761\"\u003ethree samples simultaneously\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"luz61q\" dir=\"auto\" data-start=\"5764\" data-end=\"5801\"\u003e3. What is the temperature range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5802\" data-end=\"5846\"\u003eThe specified range is \u003cstrong data-start=\"5825\" data-end=\"5845\"\u003eRT +7°C to 320°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qdjvhk\" dir=\"auto\" data-start=\"5848\" data-end=\"5890\"\u003e4. What is the temperature resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5891\" data-end=\"5919\"\u003eThe resolution is \u003cstrong data-start=\"5909\" data-end=\"5918\"\u003e0.1°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11prfo0\" dir=\"auto\" data-start=\"5921\" data-end=\"5962\"\u003e5. What heating rate can be selected?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5963\" data-end=\"6022\"\u003eThe heating rate can be set from \u003cstrong data-start=\"5996\" data-end=\"6021\"\u003e0.1°C\/min to 10°C\/min\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"uoq4pe\" dir=\"auto\" data-start=\"6024\" data-end=\"6076\"\u003e6. What type of temperature control does it use?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6077\" data-end=\"6120\"\u003eThe MPA3P uses \u003cstrong data-start=\"6092\" data-end=\"6119\"\u003ePID temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15a6ft5\" dir=\"auto\" data-start=\"6122\" data-end=\"6163\"\u003e7. Does the MPA3P have a touchscreen?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6164\" data-end=\"6207\"\u003eYes. It features a \u003cstrong data-start=\"6183\" data-end=\"6206\"\u003etouchscreen display\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1oty6ww\" dir=\"auto\" data-start=\"6209\" data-end=\"6261\"\u003e8. Can the melting process be observed directly?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6262\" data-end=\"6348\"\u003eYes. The instrument incorporates an \u003cstrong data-start=\"6298\" data-end=\"6347\"\u003eoptical lens for clear, real-time observation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13dokdk\" dir=\"auto\" data-start=\"6350\" data-end=\"6390\"\u003e9. What capillary size is specified?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6391\" data-end=\"6473\"\u003eThe specified capillary has a \u003cstrong data-start=\"6421\" data-end=\"6472\"\u003e1.6 mm outer diameter and 1.2 mm inner diameter\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11rv5ct\" dir=\"auto\" data-start=\"6475\" data-end=\"6524\"\u003e10. Does the apparatus have a data interface?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6525\" data-end=\"6566\"\u003eYes. It provides an \u003cstrong data-start=\"6545\" data-end=\"6565\"\u003eRS232C interface\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vvg9q6\" dir=\"auto\" data-start=\"6568\" data-end=\"6606\"\u003e11. What is the power requirement?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6607\" data-end=\"6679\"\u003eThe apparatus is rated at \u003cstrong data-start=\"6633\" data-end=\"6641\"\u003e100W\u003c\/strong\u003e and operates on \u003cstrong data-start=\"6658\" data-end=\"6678\"\u003eAC 220V, 50–60Hz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13myqh8\" dir=\"auto\" data-start=\"6681\" data-end=\"6719\"\u003e12. What accessories are supplied?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6720\" data-end=\"6894\"\u003eStandard accessories include the \u003cstrong data-start=\"6753\" data-end=\"6855\"\u003emain instrument, capillary tubes, power cord with adaptor, instruction manual and test certificate\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":67547001979177,"sku":"MPA3P","price":58499.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/MPA3P_Clean_White_Background.png?v=1790581251","url":"https:\/\/www.labmart.in\/products\/labmart-mpa3p-portable-melting-point-apparatus","provider":"Labmart.in","version":"1.0","type":"link"}