{"product_id":"labmart-luv1100t-touchscreen-uv-vis-spectrophotometer","title":"Touchscreen Single Beam UV-Vis Spectrophotometer LUV1100T","description":"\u003cp dir=\"auto\" data-start=\"137\" data-end=\"514\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"141\" data-end=\"210\"\u003eLabmart LUV1100T Touchscreen Single Beam UV-Vis Spectrophotometer\u003c\/strong\u003e is a versatile analytical instrument with a \u003cstrong data-start=\"255\" data-end=\"356\"\u003e190–1100 nm wavelength range, 2 nm bandwidth, 7-inch touchscreen, 32GB memory and USB data output\u003c\/strong\u003e. It supports photometric measurement, quantitative analysis, spectral scanning, kinetics, DNA\/Protein testing, multi-wavelength and multi-curve measurements.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"516\" data-end=\"549\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"551\" data-end=\"570\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"572\" data-end=\"758\"\u003eThe \u003cstrong data-start=\"576\" data-end=\"637\"\u003eLUV1100T Touchscreen Single Beam UV-Vis Spectrophotometer\u003c\/strong\u003e is designed for routine and advanced UV-Visible spectrophotometric analysis across the \u003cstrong data-start=\"725\" data-end=\"740\"\u003e190–1100 nm\u003c\/strong\u003e wavelength range.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"760\" data-end=\"1025\"\u003eThe instrument uses a \u003cstrong data-start=\"782\" data-end=\"812\"\u003esingle-beam optical system\u003c\/strong\u003e, tungsten and deuterium lamps, and a silicon photodiode detector. Its \u003cstrong data-start=\"883\" data-end=\"937\"\u003e7-inch HD TFT touchscreen and built-in 32GB memory\u003c\/strong\u003e provide an integrated platform for instrument control, measurement and data management.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1027\" data-end=\"1328\"\u003eThe LUV1100T supports a broad range of analytical functions including \u003cstrong data-start=\"1097\" data-end=\"1260\"\u003ephotometric measurement, quantitative measurement, spectral scanning, kinetics testing, DNA\/Protein testing, multi-wavelength analysis and multi-curve analysis\u003c\/strong\u003e. It can operate as a standalone system or be used with PC software.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1330\" data-end=\"1589\"\u003eThe optical system incorporates protective measures intended to reduce the effect of dust and corrosive gases on optical components, while automatic power-on self-testing and system positioning functions assist with routine instrument startup and positioning.\u003c\/p\u003e\n\u003ch2 data-section-id=\"5m7ztm\" dir=\"auto\" data-start=\"1591\" data-end=\"1619\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1621\" data-end=\"2887\"\u003e\n\u003cli data-section-id=\"12zhdxl\" data-start=\"1621\" data-end=\"1704\"\u003e\n\u003cstrong data-start=\"1623\" data-end=\"1656\"\u003e190–1100 nm wavelength range:\u003c\/strong\u003e Covers UV and visible measurement applications.\u003c\/li\u003e\n\u003cli data-section-id=\"13shpj5\" data-start=\"1705\" data-end=\"1805\"\u003e\n\u003cstrong data-start=\"1707\" data-end=\"1735\"\u003e2 nm spectral bandwidth:\u003c\/strong\u003e Provides the specified optical bandwidth for routine UV-Vis analysis.\u003c\/li\u003e\n\u003cli data-section-id=\"193irlf\" data-start=\"1806\" data-end=\"1893\"\u003e\n\u003cstrong data-start=\"1808\" data-end=\"1831\"\u003e7-inch touchscreen:\u003c\/strong\u003e Provides direct access to measurement and analysis functions.\u003c\/li\u003e\n\u003cli data-section-id=\"1d5yzjb\" data-start=\"1894\" data-end=\"1982\"\u003e\n\u003cstrong data-start=\"1896\" data-end=\"1921\"\u003e32GB internal memory:\u003c\/strong\u003e Allows substantial storage of measurement and spectral data.\u003c\/li\u003e\n\u003cli data-section-id=\"9tti8j\" data-start=\"1983\" data-end=\"2127\"\u003e\n\u003cstrong data-start=\"1985\" data-end=\"2015\"\u003eMultiple analytical modes:\u003c\/strong\u003e Supports photometric, quantitative, kinetics, spectrum scanning, DNA\/Protein and multi-wavelength measurements.\u003c\/li\u003e\n\u003cli data-section-id=\"zb8spk\" data-start=\"2128\" data-end=\"2227\"\u003e\n\u003cstrong data-start=\"2130\" data-end=\"2158\"\u003eDual lamp configuration:\u003c\/strong\u003e Tungsten and deuterium lamps support the specified wavelength range.\u003c\/li\u003e\n\u003cli data-section-id=\"1j968je\" data-start=\"2228\" data-end=\"2311\"\u003e\n\u003cstrong data-start=\"2230\" data-end=\"2250\"\u003eUSB data output:\u003c\/strong\u003e Allows measurement data and analysis reports to be exported.\u003c\/li\u003e\n\u003cli data-section-id=\"liwkq3\" data-start=\"2312\" data-end=\"2461\"\u003e\n\u003cstrong data-start=\"2314\" data-end=\"2339\"\u003eStandalone operation:\u003c\/strong\u003e Internal computing capability allows multiple analytical functions without requiring a separate PC for routine operation.\u003c\/li\u003e\n\u003cli data-section-id=\"4msfdq\" data-start=\"2462\" data-end=\"2571\"\u003e\n\u003cstrong data-start=\"2464\" data-end=\"2504\"\u003eAutomatic self-test and positioning:\u003c\/strong\u003e Helps inspect the instrument and check positioning during startup.\u003c\/li\u003e\n\u003cli data-section-id=\"5hsoiv\" data-start=\"2572\" data-end=\"2650\"\u003e\n\u003cstrong data-start=\"2574\" data-end=\"2595\"\u003e3D graph display:\u003c\/strong\u003e Supports graphical presentation of analytical results.\u003c\/li\u003e\n\u003cli data-section-id=\"q040a2\" data-start=\"2651\" data-end=\"2768\"\u003e\n\u003cstrong data-start=\"2653\" data-end=\"2684\"\u003eDirect printing capability:\u003c\/strong\u003e The system can be connected to a compatible printer for A4 data and graph printing.\u003c\/li\u003e\n\u003cli data-section-id=\"1o0jlfv\" data-start=\"2769\" data-end=\"2887\"\u003e\n\u003cstrong data-start=\"2771\" data-end=\"2787\"\u003ePC software:\u003c\/strong\u003e Provides additional data management functions including user management, logging and data tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2889\" data-end=\"2918\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2920\" data-end=\"4075\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2920\" data-end=\"2948\"\u003e\n\u003ctr data-start=\"2920\" data-end=\"2948\"\u003e\n\u003cth data-start=\"2920\" data-end=\"2936\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2936\" data-end=\"2948\" data-col-size=\"md\" class=\"last:pe-10\"\u003eLUV1100T\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2959\" data-end=\"4075\"\u003e\n\u003ctr data-start=\"2959\" data-end=\"3026\"\u003e\n\u003ctd data-start=\"2959\" data-end=\"2974\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2974\" data-end=\"3026\" data-col-size=\"md\"\u003eTouchscreen Single Beam UV-Vis Spectrophotometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3027\" data-end=\"3047\"\u003e\n\u003ctd data-start=\"3027\" data-end=\"3035\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"3035\" data-end=\"3047\" data-col-size=\"md\"\u003eLUV1100T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3048\" data-end=\"3067\"\u003e\n\u003ctd data-start=\"3048\" data-end=\"3056\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"3056\" data-end=\"3067\" data-col-size=\"md\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3068\" data-end=\"3100\"\u003e\n\u003ctd data-start=\"3068\" data-end=\"3085\" data-col-size=\"sm\"\u003eOptical System\u003c\/td\u003e\n\u003ctd data-start=\"3085\" data-end=\"3100\" data-col-size=\"md\"\u003eSingle Beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3101\" data-end=\"3135\"\u003e\n\u003ctd data-start=\"3101\" data-end=\"3120\" data-col-size=\"sm\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd data-start=\"3120\" data-end=\"3135\" data-col-size=\"md\"\u003e190–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3136\" data-end=\"3158\"\u003e\n\u003ctd data-start=\"3136\" data-end=\"3148\" data-col-size=\"sm\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd data-start=\"3148\" data-end=\"3158\" data-col-size=\"md\"\u003e2.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3159\" data-end=\"3192\"\u003e\n\u003ctd data-start=\"3159\" data-end=\"3181\" data-col-size=\"sm\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3181\" data-end=\"3192\"\u003e±0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3193\" data-end=\"3231\"\u003e\n\u003ctd data-start=\"3193\" data-end=\"3220\" data-col-size=\"sm\"\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"3220\" data-end=\"3231\" data-col-size=\"md\"\u003e+0.2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3232\" data-end=\"3266\"\u003e\n\u003ctd data-start=\"3232\" data-end=\"3256\" data-col-size=\"sm\"\u003eWavelength Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3256\" data-end=\"3266\"\u003e0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3267\" data-end=\"3318\"\u003e\n\u003ctd data-start=\"3267\" data-end=\"3287\" data-col-size=\"sm\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3287\" data-end=\"3318\"\u003e0–200%T; -0.3–3.0A; 0–9999C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3319\" data-end=\"3412\"\u003e\n\u003ctd data-start=\"3319\" data-end=\"3342\" data-col-size=\"sm\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3342\" data-end=\"3412\" data-col-size=\"md\"\u003e±0.2%T (0–100%T); ±0.002 Abs (0–0.5 Abs); ±0.004 Abs (0.5–1.0 Abs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3413\" data-end=\"3509\"\u003e\n\u003ctd data-start=\"3413\" data-end=\"3441\" data-col-size=\"sm\"\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3441\" data-end=\"3509\"\u003e≤0.1%T (0–100%T); 0.001 Abs (0–0.5 Abs); 0.002 Abs (0.5–1.0 Abs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3510\" data-end=\"3545\"\u003e\n\u003ctd data-start=\"3510\" data-end=\"3522\" data-col-size=\"sm\"\u003eStability\u003c\/td\u003e\n\u003ctd data-start=\"3522\" data-end=\"3545\" data-col-size=\"md\"\u003e+0.001 A\/h @ 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3546\" data-end=\"3580\"\u003e\n\u003ctd data-start=\"3546\" data-end=\"3566\" data-col-size=\"sm\"\u003eBaseline Flatness\u003c\/td\u003e\n\u003ctd data-start=\"3566\" data-end=\"3580\" data-col-size=\"md\"\u003e±0.001 A\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3581\" data-end=\"3625\"\u003e\n\u003ctd data-start=\"3581\" data-end=\"3595\" data-col-size=\"sm\"\u003eStray Light\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3595\" data-end=\"3625\"\u003e0.05%T @ 220 nm and 360 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3626\" data-end=\"3686\"\u003e\n\u003ctd data-start=\"3626\" data-end=\"3640\" data-col-size=\"sm\"\u003eCell Holder\u003c\/td\u003e\n\u003ctd data-start=\"3640\" data-end=\"3686\" data-col-size=\"md\"\u003e10 mm sample and reference cuvette holders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3687\" data-end=\"3711\"\u003e\n\u003ctd data-start=\"3687\" data-end=\"3702\" data-col-size=\"sm\"\u003eFocal Length\u003c\/td\u003e\n\u003ctd data-start=\"3702\" data-end=\"3711\" data-col-size=\"md\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3712\" data-end=\"3761\"\u003e\n\u003ctd data-start=\"3712\" data-end=\"3727\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"3727\" data-end=\"3761\" data-col-size=\"md\"\u003eTungsten Lamp \u0026amp; Deuterium Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3762\" data-end=\"3795\"\u003e\n\u003ctd data-start=\"3762\" data-end=\"3773\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"3773\" data-end=\"3795\" data-col-size=\"md\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3796\" data-end=\"3846\"\u003e\n\u003ctd data-start=\"3796\" data-end=\"3806\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3806\" data-end=\"3846\" data-col-size=\"md\"\u003e7-inch Touchscreen, 800 × 480 HD TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3847\" data-end=\"3873\"\u003e\n\u003ctd data-start=\"3847\" data-end=\"3865\" data-col-size=\"sm\"\u003eInternal Memory\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3865\" data-end=\"3873\"\u003e32GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3874\" data-end=\"3924\"\u003e\n\u003ctd data-start=\"3874\" data-end=\"3889\" data-col-size=\"sm\"\u003eControl Mode\u003c\/td\u003e\n\u003ctd data-start=\"3889\" data-end=\"3924\" data-col-size=\"md\"\u003eStandalone System \/ PC Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3925\" data-end=\"3946\"\u003e\n\u003ctd data-start=\"3925\" data-end=\"3939\" data-col-size=\"sm\"\u003eData Output\u003c\/td\u003e\n\u003ctd data-start=\"3939\" data-end=\"3946\" data-col-size=\"md\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3947\" data-end=\"3982\"\u003e\n\u003ctd data-start=\"3947\" data-end=\"3962\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3962\" data-end=\"3982\" data-col-size=\"md\"\u003eAC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3983\" data-end=\"4026\"\u003e\n\u003ctd data-start=\"3983\" data-end=\"4004\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"4004\" data-end=\"4026\" data-col-size=\"md\"\u003e645 × 550 × 405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4027\" data-end=\"4051\"\u003e\n\u003ctd data-start=\"4027\" data-end=\"4042\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"4042\" data-end=\"4051\" data-col-size=\"md\"\u003e25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4052\" data-end=\"4075\"\u003e\n\u003ctd data-start=\"4052\" data-end=\"4063\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"4063\" data-end=\"4075\" data-col-size=\"md\"\u003e90273020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"4077\" data-end=\"4094\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"4096\" data-end=\"4125\"\u003eThe LUV1100T can be used for:\u003c\/p\u003e\n\u003cul data-start=\"4127\" data-end=\"4578\"\u003e\n\u003cli data-section-id=\"302rhu\" data-start=\"4127\" data-end=\"4160\"\u003eUV-Visible photometric analysis\u003c\/li\u003e\n\u003cli data-section-id=\"k5sf9z\" data-start=\"4161\" data-end=\"4184\"\u003eQuantitative analysis\u003c\/li\u003e\n\u003cli data-section-id=\"7juhhz\" data-start=\"4185\" data-end=\"4204\"\u003eSpectral scanning\u003c\/li\u003e\n\u003cli data-section-id=\"1qsgvz9\" data-start=\"4205\" data-end=\"4223\"\u003eKinetics studies\u003c\/li\u003e\n\u003cli data-section-id=\"k7n4s1\" data-start=\"4224\" data-end=\"4238\"\u003eDNA analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1o8qx6p\" data-start=\"4239\" data-end=\"4257\"\u003eProtein analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1hneob0\" data-start=\"4258\" data-end=\"4289\"\u003eMulti-wavelength measurements\u003c\/li\u003e\n\u003cli data-section-id=\"yir689\" data-start=\"4290\" data-end=\"4312\"\u003eMulti-curve analysis\u003c\/li\u003e\n\u003cli data-section-id=\"fwhkzv\" data-start=\"4313\" data-end=\"4344\"\u003eCalibration-curve development\u003c\/li\u003e\n\u003cli data-section-id=\"12c7fd8\" data-start=\"4345\" data-end=\"4374\"\u003eConcentration determination\u003c\/li\u003e\n\u003cli data-section-id=\"kh6azt\" data-start=\"4375\" data-end=\"4401\"\u003eResearch and development\u003c\/li\u003e\n\u003cli data-section-id=\"154x4wp\" data-start=\"4402\" data-end=\"4427\"\u003eQuality-control testing\u003c\/li\u003e\n\u003cli data-section-id=\"17kuc3i\" data-start=\"4428\" data-end=\"4464\"\u003ePharmaceutical laboratory analysis\u003c\/li\u003e\n\u003cli data-section-id=\"xufp6l\" data-start=\"4465\" data-end=\"4495\"\u003eChemical laboratory analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1b7zlh3\" data-start=\"4496\" data-end=\"4541\"\u003eBiotechnology and life-science applications\u003c\/li\u003e\n\u003cli data-section-id=\"3mp62m\" data-start=\"4542\" data-end=\"4578\"\u003eEducational laboratory experiments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"4580\" data-end=\"4597\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"4599\" data-end=\"4628\"\u003eThe LUV1100T is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"4630\" data-end=\"4953\"\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"4630\" data-end=\"4659\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"4660\" data-end=\"4683\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1or0uhb\" data-start=\"4684\" data-end=\"4712\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1t31nfa\" data-start=\"4713\" data-end=\"4736\"\u003eResearch institutions\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"4737\" data-end=\"4767\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"brvkbz\" data-start=\"4768\" data-end=\"4785\"\u003eR\u0026amp;D departments\u003c\/li\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"4786\" data-end=\"4818\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"fp3bpf\" data-start=\"4819\" data-end=\"4855\"\u003eEnvironmental testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"167fuah\" data-start=\"4856\" data-end=\"4883\"\u003eUniversities and colleges\u003c\/li\u003e\n\u003cli data-section-id=\"pmp1u9\" data-start=\"4884\" data-end=\"4916\"\u003eScientific research facilities\u003c\/li\u003e\n\u003cli data-section-id=\"rxfsyq\" data-start=\"4917\" data-end=\"4953\"\u003eIndustrial analytical laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"7415\" data-end=\"7425\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1h1u1c8\" dir=\"auto\" data-start=\"7427\" data-end=\"7464\"\u003e1. What is the LUV1100T used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7466\" data-end=\"7636\"\u003eThe LUV1100T is a \u003cstrong data-start=\"7484\" data-end=\"7524\"\u003esingle-beam UV-Vis spectrophotometer\u003c\/strong\u003e designed for photometric, quantitative, spectral scanning, kinetics, DNA\/Protein and multi-wavelength analysis.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15po622\" dir=\"auto\" data-start=\"7638\" data-end=\"7674\"\u003e2. What is the wavelength range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7676\" data-end=\"7716\"\u003eThe wavelength range is \u003cstrong data-start=\"7700\" data-end=\"7715\"\u003e190–1100 nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"h7pgoc\" dir=\"auto\" data-start=\"7718\" data-end=\"7756\"\u003e3. What is the spectral bandwidth?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7758\" data-end=\"7796\"\u003eThe specified bandwidth is \u003cstrong data-start=\"7785\" data-end=\"7795\"\u003e2.0 nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1fg03vy\" dir=\"auto\" data-start=\"7798\" data-end=\"7837\"\u003e4. What is the wavelength accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7839\" data-end=\"7888\"\u003eThe specified wavelength accuracy is \u003cstrong data-start=\"7876\" data-end=\"7887\"\u003e±0.5 nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"b39dls\" dir=\"auto\" data-start=\"7890\" data-end=\"7935\"\u003e5. What detector does the instrument use?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7937\" data-end=\"7989\"\u003eThe LUV1100T uses a \u003cstrong data-start=\"7957\" data-end=\"7988\"\u003esilicon photodiode detector\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"uwnzyi\" dir=\"auto\" data-start=\"7991\" data-end=\"8026\"\u003e6. What light sources are used?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8028\" data-end=\"8081\"\u003eThe instrument uses \u003cstrong data-start=\"8048\" data-end=\"8080\"\u003etungsten and deuterium lamps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"vq4pu5\" dir=\"auto\" data-start=\"8083\" data-end=\"8127\"\u003e7. Does the LUV1100T have a touchscreen?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8129\" data-end=\"8204\"\u003eYes. It features a \u003cstrong data-start=\"8148\" data-end=\"8203\"\u003e7-inch HD TFT touchscreen with 800 × 480 resolution\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"59chrk\" dir=\"auto\" data-start=\"8206\" data-end=\"8251\"\u003e8. How much internal memory does it have?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8253\" data-end=\"8300\"\u003eThe instrument has \u003cstrong data-start=\"8272\" data-end=\"8299\"\u003e32GB of internal memory\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"s1hlda\" dir=\"auto\" data-start=\"8302\" data-end=\"8352\"\u003e9. Can the LUV1100T perform spectral scanning?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8354\" data-end=\"8426\"\u003eYes. \u003cstrong data-start=\"8359\" data-end=\"8380\"\u003eSpectrum scanning\u003c\/strong\u003e is one of the specified analytical functions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"10hyrq3\" dir=\"auto\" data-start=\"8428\" data-end=\"8475\"\u003e10. Can it perform DNA and Protein testing?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8477\" data-end=\"8568\"\u003eYes. The supplied specifications identify \u003cstrong data-start=\"8519\" data-end=\"8542\"\u003eDNA\/Protein testing\u003c\/strong\u003e as an available function.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mf6xxf\" dir=\"auto\" data-start=\"8570\" data-end=\"8611\"\u003e11. Can measurement data be exported?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8613\" data-end=\"8725\"\u003eYes. Data can be exported through \u003cstrong data-start=\"8647\" data-end=\"8654\"\u003eUSB\u003c\/strong\u003e, and the system supports direct data transfer to a USB storage device.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1j3l0ih\" dir=\"auto\" data-start=\"8727\" data-end=\"8762\"\u003e12. What cuvettes are supplied?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8764\" data-end=\"8848\"\u003eThe standard accessories include a \u003cstrong data-start=\"8799\" data-end=\"8847\"\u003e10 mm quartz cuvette and 10 mm glass cuvette\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52642943009065,"sku":"LUV1100T","price":204699.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/rs_w_720_cg_true_1.webp?v=1770941284","url":"https:\/\/www.labmart.in\/products\/labmart-luv1100t-touchscreen-uv-vis-spectrophotometer","provider":"Labmart.in","version":"1.0","type":"link"}