{"product_id":"labmart-lmph1p-portable-ph-meter","title":"Portable pH Meter LMPH1P","description":"\u003cp dir=\"auto\" data-start=\"132\" data-end=\"474\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"136\" data-end=\"172\"\u003eLabmart LMPH1P Portable pH Meter\u003c\/strong\u003e is a laboratory-grade portable instrument for accurate pH, mV and temperature measurement. It offers a \u003cstrong data-start=\"276\" data-end=\"473\"\u003e-2.00 to 20.00 pH range, 0.01 pH resolution, ±0.01 pH accuracy, automatic temperature compensation, 1–3 point calibration, 100-data memory, USB connectivity and LCD display with white backlight\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"511\" data-end=\"530\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"532\" data-end=\"810\"\u003eThe \u003cstrong data-start=\"536\" data-end=\"564\"\u003eLMPH1P Portable pH Meter\u003c\/strong\u003e is designed for routine laboratory measurement of \u003cstrong data-start=\"615\" data-end=\"673\"\u003epH, oxidation-reduction potential (mV) and temperature\u003c\/strong\u003e. Its portable format makes it suitable for laboratories and applications where measurements need to be performed at different locations.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"812\" data-end=\"1075\"\u003eThe meter supports \u003cstrong data-start=\"831\" data-end=\"859\"\u003e1 to 3-point calibration\u003c\/strong\u003e with automatic recognition of USA and NIST buffer sets. Automatic electrode diagnosis helps the user assess the condition of the pH electrode, while the auto-read function detects and locks the measurement endpoint.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1077\" data-end=\"1263\"\u003eThe instrument provides \u003cstrong data-start=\"1101\" data-end=\"1149\"\u003eautomatic or manual temperature compensation\u003c\/strong\u003e, stores up to \u003cstrong data-start=\"1164\" data-end=\"1181\"\u003e100 data sets\u003c\/strong\u003e, and includes a USB interface for data transfer or connection to a power adapter.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1265\" data-end=\"1291\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1293\" data-end=\"1965\"\u003e\n\u003cli data-section-id=\"m9oebw\" data-start=\"1293\" data-end=\"1325\"\u003ePortable pH measurement system\u003c\/li\u003e\n\u003cli data-section-id=\"1qa44y3\" data-start=\"1326\" data-end=\"1359\"\u003e\u003cstrong data-start=\"1328\" data-end=\"1359\"\u003epH range: -2.00 to 20.00 pH\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"ehjp6p\" data-start=\"1360\" data-end=\"1384\"\u003e\u003cstrong data-start=\"1362\" data-end=\"1384\"\u003e0.01 pH resolution\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1a8aeyr\" data-start=\"1385\" data-end=\"1408\"\u003e\u003cstrong data-start=\"1387\" data-end=\"1408\"\u003e±0.01 pH accuracy\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"obzeu7\" data-start=\"1409\" data-end=\"1436\"\u003e\u003cstrong data-start=\"1411\" data-end=\"1436\"\u003e1–3 point calibration\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"123wdy6\" data-start=\"1437\" data-end=\"1480\"\u003eAutomatic USA and NIST buffer recognition\u003c\/li\u003e\n\u003cli data-section-id=\"1silm1d\" data-start=\"1481\" data-end=\"1512\"\u003eAutomatic electrode diagnosis\u003c\/li\u003e\n\u003cli data-section-id=\"7gdkz1\" data-start=\"1513\" data-end=\"1549\"\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cli data-section-id=\"ag6fuy\" data-start=\"1550\" data-end=\"1606\"\u003eManual or automatic temperature compensation selection\u003c\/li\u003e\n\u003cli data-section-id=\"1r5j0no\" data-start=\"1607\" data-end=\"1631\"\u003e\u003cstrong data-start=\"1609\" data-end=\"1631\"\u003emV range: ±1999 mV\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"ifxpdj\" data-start=\"1632\" data-end=\"1656\"\u003e\u003cstrong data-start=\"1634\" data-end=\"1656\"\u003e1 mV mV resolution\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1l8mlth\" data-start=\"1657\" data-end=\"1680\"\u003e\u003cstrong data-start=\"1659\" data-end=\"1680\"\u003e±1 mV mV accuracy\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1vtl2j8\" data-start=\"1681\" data-end=\"1711\"\u003eAuto-read endpoint detection\u003c\/li\u003e\n\u003cli data-section-id=\"1mgz4f3\" data-start=\"1712\" data-end=\"1734\"\u003eManual hold function\u003c\/li\u003e\n\u003cli data-section-id=\"m4vvt5\" data-start=\"1735\" data-end=\"1769\"\u003eLCD display with white backlight\u003c\/li\u003e\n\u003cli data-section-id=\"rkrvm2\" data-start=\"1770\" data-end=\"1795\"\u003e\u003cstrong data-start=\"1772\" data-end=\"1795\"\u003e100-data-set memory\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"9xuscp\" data-start=\"1796\" data-end=\"1811\"\u003eUSB interface\u003c\/li\u003e\n\u003cli data-section-id=\"jf09g6\" data-start=\"1812\" data-end=\"1838\"\u003eBNC electrode connection\u003c\/li\u003e\n\u003cli data-section-id=\"1kh6qtk\" data-start=\"1839\" data-end=\"1860\"\u003eAutomatic power-off\u003c\/li\u003e\n\u003cli data-section-id=\"1jf7cw6\" data-start=\"1861\" data-end=\"1920\"\u003eApproximately \u003cstrong data-start=\"1877\" data-end=\"1920\"\u003e150-hour battery life without backlight\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"h6csec\" data-start=\"1921\" data-end=\"1965\"\u003eCarrying case available as standard supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"1967\" data-end=\"1996\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1998\" data-end=\"3058\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1998\" data-end=\"2024\"\u003e\n\u003ctr data-start=\"1998\" data-end=\"2024\"\u003e\n\u003cth data-start=\"1998\" data-end=\"2014\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2014\" data-end=\"2024\" data-col-size=\"md\" class=\"last:pe-10\"\u003eLMPH1P\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2035\" data-end=\"3058\"\u003e\n\u003ctr data-start=\"2035\" data-end=\"2071\"\u003e\n\u003ctd data-start=\"2035\" data-end=\"2050\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2050\" data-end=\"2071\" data-col-size=\"md\"\u003ePortable pH Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2072\" data-end=\"2090\"\u003e\n\u003ctd data-start=\"2072\" data-end=\"2080\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2080\" data-end=\"2090\" data-col-size=\"md\"\u003eLMPH1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2091\" data-end=\"2110\"\u003e\n\u003ctd data-start=\"2091\" data-end=\"2099\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2099\" data-end=\"2110\" data-col-size=\"md\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2111\" data-end=\"2143\"\u003e\n\u003ctd data-start=\"2111\" data-end=\"2122\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2122\" data-end=\"2143\" data-col-size=\"md\"\u003e-2.00 to 20.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2144\" data-end=\"2171\"\u003e\n\u003ctd data-start=\"2144\" data-end=\"2160\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2160\" data-end=\"2171\" data-col-size=\"md\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2172\" data-end=\"2198\"\u003e\n\u003ctd data-start=\"2172\" data-end=\"2186\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2186\" data-end=\"2198\" data-col-size=\"md\"\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2199\" data-end=\"2230\"\u003e\n\u003ctd data-start=\"2199\" data-end=\"2213\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2213\" data-end=\"2230\" data-col-size=\"md\"\u003e1 to 3 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2231\" data-end=\"2305\"\u003e\n\u003ctd data-start=\"2231\" data-end=\"2245\" data-col-size=\"sm\"\u003eBuffer Sets\u003c\/td\u003e\n\u003ctd data-start=\"2245\" data-end=\"2305\" data-col-size=\"md\"\u003eUSA: pH 4.01 \/ 7.00 \/ 10.01; NIST: pH 4.01 \/ 6.86 \/ 9.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2306\" data-end=\"2329\"\u003e\n\u003ctd data-start=\"2306\" data-end=\"2317\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"2317\" data-end=\"2329\" data-col-size=\"md\"\u003e±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2330\" data-end=\"2354\"\u003e\n\u003ctd data-start=\"2330\" data-end=\"2346\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2346\" data-end=\"2354\" data-col-size=\"md\"\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2355\" data-end=\"2378\"\u003e\n\u003ctd data-start=\"2355\" data-end=\"2369\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2369\" data-end=\"2378\" data-col-size=\"md\"\u003e±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2379\" data-end=\"2427\"\u003e\n\u003ctd data-start=\"2379\" data-end=\"2399\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2399\" data-end=\"2427\" data-col-size=\"md\"\u003e0 to 105°C \/ 32 to 221°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2428\" data-end=\"2470\"\u003e\n\u003ctd data-start=\"2428\" data-end=\"2453\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2453\" data-end=\"2470\" data-col-size=\"md\"\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2471\" data-end=\"2513\"\u003e\n\u003ctd data-start=\"2471\" data-end=\"2494\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2494\" data-end=\"2513\" data-col-size=\"md\"\u003e±0.5°C \/ ±0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2514\" data-end=\"2590\"\u003e\n\u003ctd data-start=\"2514\" data-end=\"2541\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"2541\" data-end=\"2590\" data-col-size=\"md\"\u003e0 to 100°C \/ 32 to 212°F, manual or automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2591\" data-end=\"2650\"\u003e\n\u003ctd data-start=\"2591\" data-end=\"2607\" data-col-size=\"sm\"\u003eHold Function\u003c\/td\u003e\n\u003ctd data-start=\"2607\" data-end=\"2650\" data-col-size=\"md\"\u003eManual \/ Auto-read measurement endpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2651\" data-end=\"2689\"\u003e\n\u003ctd data-start=\"2651\" data-end=\"2661\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2661\" data-end=\"2689\" data-col-size=\"md\"\u003eLCD with white backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2690\" data-end=\"2709\"\u003e\n\u003ctd data-start=\"2690\" data-end=\"2702\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2702\" data-end=\"2709\" data-col-size=\"md\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2710\" data-end=\"2739\"\u003e\n\u003ctd data-start=\"2710\" data-end=\"2732\" data-col-size=\"sm\"\u003eElectrode Connector\u003c\/td\u003e\n\u003ctd data-start=\"2732\" data-end=\"2739\" data-col-size=\"md\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2740\" data-end=\"2769\"\u003e\n\u003ctd data-start=\"2740\" data-end=\"2756\" data-col-size=\"sm\"\u003eCarrying Case\u003c\/td\u003e\n\u003ctd data-start=\"2756\" data-end=\"2769\" data-col-size=\"md\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2770\" data-end=\"2809\"\u003e\n\u003ctd data-start=\"2770\" data-end=\"2781\" data-col-size=\"sm\"\u003eAuto OFF\u003c\/td\u003e\n\u003ctd data-start=\"2781\" data-end=\"2809\" data-col-size=\"md\"\u003e30 minutes if not in use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2810\" data-end=\"2836\"\u003e\n\u003ctd data-start=\"2810\" data-end=\"2819\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2819\" data-end=\"2836\" data-col-size=\"md\"\u003e100 data sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2837\" data-end=\"2900\"\u003e\n\u003ctd data-start=\"2837\" data-end=\"2852\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2852\" data-end=\"2900\" data-col-size=\"md\"\u003e3 × 1.5V AA batteries or 5V DC power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2901\" data-end=\"2955\"\u003e\n\u003ctd data-start=\"2901\" data-end=\"2916\" data-col-size=\"sm\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd data-start=\"2916\" data-end=\"2955\" data-col-size=\"md\"\u003eApprox. 150 hours without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2956\" data-end=\"3010\"\u003e\n\u003ctd data-start=\"2956\" data-end=\"2989\" data-col-size=\"sm\"\u003ePacking Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd data-start=\"2989\" data-end=\"3010\" data-col-size=\"md\"\u003e340 × 90 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3011\" data-end=\"3034\"\u003e\n\u003ctd data-start=\"3011\" data-end=\"3026\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3026\" data-end=\"3034\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3035\" data-end=\"3058\"\u003e\n\u003ctd data-start=\"3035\" data-end=\"3046\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"3046\" data-end=\"3058\" data-col-size=\"md\"\u003e90275090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3060\" data-end=\"3077\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3079\" data-end=\"3106\"\u003eThe LMPH1P is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3108\" data-end=\"3470\"\u003e\n\u003cli data-section-id=\"bbmhi1\" data-start=\"3108\" data-end=\"3135\"\u003eLaboratory pH measurement\u003c\/li\u003e\n\u003cli data-section-id=\"qeh43v\" data-start=\"3136\" data-end=\"3159\"\u003eWater-quality testing\u003c\/li\u003e\n\u003cli data-section-id=\"1q12ni6\" data-start=\"3160\" data-end=\"3179\"\u003eChemical analysis\u003c\/li\u003e\n\u003cli data-section-id=\"16yj6ii\" data-start=\"3180\" data-end=\"3215\"\u003ePharmaceutical laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"1qk70oi\" data-start=\"3216\" data-end=\"3243\"\u003eFood and beverage testing\u003c\/li\u003e\n\u003cli data-section-id=\"w1xo7a\" data-start=\"3244\" data-end=\"3267\"\u003eEnvironmental testing\u003c\/li\u003e\n\u003cli data-section-id=\"kh6azt\" data-start=\"3268\" data-end=\"3294\"\u003eResearch and development\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3295\" data-end=\"3325\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1q5aoag\" data-start=\"3326\" data-end=\"3362\"\u003eAcademic and teaching laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"11u78wb\" data-start=\"3363\" data-end=\"3401\"\u003eGeneral liquid-sample pH measurement\u003c\/li\u003e\n\u003cli data-section-id=\"12lk7p\" data-start=\"3402\" data-end=\"3470\"\u003emV\/ORP-related measurements where an appropriate electrode is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3472\" data-end=\"3489\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3491\" data-end=\"3518\"\u003eThe LMPH1P is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3520\" data-end=\"3804\"\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3520\" data-end=\"3543\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3544\" data-end=\"3573\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"3574\" data-end=\"3606\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1iu5xdh\" data-start=\"3607\" data-end=\"3635\"\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1fs6tb7\" data-start=\"3636\" data-end=\"3664\"\u003eWater-testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1t31nfa\" data-start=\"3665\" data-end=\"3688\"\u003eResearch institutions\u003c\/li\u003e\n\u003cli data-section-id=\"rlkbyw\" data-start=\"3689\" data-end=\"3718\"\u003eQuality-control departments\u003c\/li\u003e\n\u003cli data-section-id=\"167fuah\" data-start=\"3719\" data-end=\"3746\"\u003eUniversities and colleges\u003c\/li\u003e\n\u003cli data-section-id=\"10vtoei\" data-start=\"3747\" data-end=\"3772\"\u003eIndustrial laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"12am74\" data-start=\"3773\" data-end=\"3804\"\u003eField laboratory applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"6139\" data-end=\"6149\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1ame86j\" dir=\"auto\" data-start=\"6151\" data-end=\"6186\"\u003e1. What is the LMPH1P used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6188\" data-end=\"6280\"\u003eThe LMPH1P is a portable meter for measuring \u003cstrong data-start=\"6233\" data-end=\"6259\"\u003epH, mV and temperature\u003c\/strong\u003e in suitable samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxtlr5\" dir=\"auto\" data-start=\"6282\" data-end=\"6322\"\u003e2. What is the pH measurement range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6324\" data-end=\"6362\"\u003eThe pH range is \u003cstrong data-start=\"6340\" data-end=\"6361\"\u003e-2.00 to 20.00 pH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"usdf0b\" dir=\"auto\" data-start=\"6364\" data-end=\"6397\"\u003e3. What is the pH resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6399\" data-end=\"6429\"\u003eThe resolution is \u003cstrong data-start=\"6417\" data-end=\"6428\"\u003e0.01 pH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"17sebxr\" dir=\"auto\" data-start=\"6431\" data-end=\"6462\"\u003e4. What is the pH accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6464\" data-end=\"6503\"\u003eThe specified accuracy is \u003cstrong data-start=\"6490\" data-end=\"6502\"\u003e±0.01 pH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t9zfdf\" dir=\"auto\" data-start=\"6505\" data-end=\"6554\"\u003e5. How many calibration points are available?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6556\" data-end=\"6605\"\u003eThe LMPH1P supports \u003cstrong data-start=\"6576\" data-end=\"6604\"\u003e1 to 3-point calibration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hekmrh\" dir=\"auto\" data-start=\"6607\" data-end=\"6654\"\u003e6. Which calibration buffers are supported?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6656\" data-end=\"6752\"\u003eIt supports USA buffers \u003cstrong data-start=\"6680\" data-end=\"6707\"\u003epH 4.01, 7.00 and 10.01\u003c\/strong\u003e and NIST buffers \u003cstrong data-start=\"6725\" data-end=\"6751\"\u003epH 4.01, 6.86 and 9.18\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"da9q1c\" dir=\"auto\" data-start=\"6754\" data-end=\"6816\"\u003e7. Does the meter have automatic temperature compensation?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6818\" data-end=\"6929\"\u003eYes. Temperature compensation can be selected as \u003cstrong data-start=\"6867\" data-end=\"6890\"\u003emanual or automatic\u003c\/strong\u003e over the specified compensation range.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11qjcx4\" dir=\"auto\" data-start=\"6931\" data-end=\"6971\"\u003e8. What is the mV measurement range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6973\" data-end=\"7043\"\u003eThe mV range is \u003cstrong data-start=\"6989\" data-end=\"7001\"\u003e±1999 mV\u003c\/strong\u003e, with 1 mV resolution and ±1 mV accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1fmfn6v\" dir=\"auto\" data-start=\"7045\" data-end=\"7092\"\u003e9. How much measurement data can be stored?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7094\" data-end=\"7138\"\u003eThe meter can store up to \u003cstrong data-start=\"7120\" data-end=\"7137\"\u003e100 data sets\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1som7pt\" dir=\"auto\" data-start=\"7140\" data-end=\"7186\"\u003e10. Does the LMPH1P have USB connectivity?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7188\" data-end=\"7271\"\u003eYes. It has a \u003cstrong data-start=\"7202\" data-end=\"7219\"\u003eUSB interface\u003c\/strong\u003e for data transfer or connection to a power adapter.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1m6e3wr\" dir=\"auto\" data-start=\"7273\" data-end=\"7326\"\u003e11. What type of electrode connector does it use?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7328\" data-end=\"7368\"\u003eThe instrument uses a \u003cstrong data-start=\"7350\" data-end=\"7367\"\u003eBNC connector\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"tuxjyk\" dir=\"auto\" data-start=\"7370\" data-end=\"7410\"\u003e12. What is included with the meter?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7412\" data-end=\"7541\"\u003eThe standard accessories include the \u003cstrong data-start=\"7449\" data-end=\"7540\"\u003emain instrument, pH electrode, pH buffer pouch, instruction manual and test certificate\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":67556700684585,"sku":"LMPH1P","price":13499.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/1_b15d19a2-59a4-445b-be97-53b14ef659fa.png?v=1790752128","url":"https:\/\/www.labmart.in\/products\/labmart-lmph1p-portable-ph-meter","provider":"Labmart.in","version":"1.0","type":"link"}