{"product_id":"labmart-lmph15-ph-meter-with-thermal-printer","title":"pH Meter-With Printer-LMPH15","description":"\u003cp dir=\"auto\" data-start=\"144\" data-end=\"547\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"148\" data-end=\"196\"\u003eLabmart LMPH15 pH Meter with Thermal Printer\u003c\/strong\u003e is a benchtop laboratory pH\/ORP meter featuring \u003cstrong data-start=\"245\" data-end=\"418\"\u003e1–5 point pH calibration, automatic temperature compensation, automatic electrode diagnosis, Auto-Read endpoint detection, built-in thermal printing and 1000-data memory\u003c\/strong\u003e. It measures pH from \u003cstrong data-start=\"440\" data-end=\"460\"\u003e-2.000 to 20.000\u003c\/strong\u003e with selectable 0.001\/0.01 resolution and provides ORP measurement up to \u003cstrong data-start=\"534\" data-end=\"546\"\u003e±2000 mV\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"549\" data-end=\"582\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"584\" data-end=\"603\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"605\" data-end=\"890\"\u003eThe \u003cstrong data-start=\"609\" data-end=\"649\"\u003eLMPH15 pH Meter with Thermal Printer\u003c\/strong\u003e is designed for accurate laboratory measurement of \u003cstrong data-start=\"701\" data-end=\"715\"\u003epH and ORP\u003c\/strong\u003e, with integrated temperature measurement and compensation. Its large \u003cstrong data-start=\"785\" data-end=\"803\"\u003e7-inch TFT LCD\u003c\/strong\u003e provides a clear interface for measurement, calibration and data-management functions.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"892\" data-end=\"1149\"\u003eThe instrument supports \u003cstrong data-start=\"916\" data-end=\"948\"\u003eup to 5-point pH calibration\u003c\/strong\u003e with automatic recognition of USA, NIST, DIN and user-defined buffer sets. Automatic electrode diagnosis displays pH slope and zero offset, helping users assess electrode condition during calibration.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1151\" data-end=\"1433\"\u003eFor ORP measurements, the LMPH15 provides \u003cstrong data-start=\"1193\" data-end=\"1234\"\u003eabsolute and relative millivolt modes\u003c\/strong\u003e and 1-point offset calibration. Additional features include Auto-Read endpoint detection, high\/low limit alarms, calibration-due alarms, password protection and storage for up to \u003cstrong data-start=\"1414\" data-end=\"1432\"\u003e1000 data sets\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1435\" data-end=\"1666\"\u003eAn integrated \u003cstrong data-start=\"1449\" data-end=\"1468\"\u003ethermal printer\u003c\/strong\u003e allows measurement information and calibration reports to be printed directly from the instrument. The supplied catalogue also shows dedicated print formats for pH analysis and calibration reports.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1668\" data-end=\"1694\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1696\" data-end=\"2406\"\u003e\n\u003cli data-section-id=\"k3twsp\" data-start=\"1696\" data-end=\"1727\"\u003epH range \u003cstrong data-start=\"1707\" data-end=\"1727\"\u003e-2.000 to 20.000\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1sjiukx\" data-start=\"1728\" data-end=\"1772\"\u003eSelectable pH resolution \u003cstrong data-start=\"1755\" data-end=\"1772\"\u003e0.001 or 0.01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1uiftew\" data-start=\"1773\" data-end=\"1800\"\u003epH accuracy \u003cstrong data-start=\"1787\" data-end=\"1800\"\u003e±0.002 pH\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jm0d1s\" data-start=\"1801\" data-end=\"1835\"\u003eUp to \u003cstrong data-start=\"1809\" data-end=\"1835\"\u003e5-point pH calibration\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1v93olm\" data-start=\"1836\" data-end=\"1884\"\u003eUSA, NIST, DIN and user-defined buffer options\u003c\/li\u003e\n\u003cli data-section-id=\"1silm1d\" data-start=\"1885\" data-end=\"1916\"\u003eAutomatic electrode diagnosis\u003c\/li\u003e\n\u003cli data-section-id=\"kj5kmq\" data-start=\"1917\" data-end=\"1941\"\u003eORP range \u003cstrong data-start=\"1929\" data-end=\"1941\"\u003e±2000 mV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10f2697\" data-start=\"1942\" data-end=\"1974\"\u003eRelative and absolute mV modes\u003c\/li\u003e\n\u003cli data-section-id=\"7gdkz1\" data-start=\"1975\" data-end=\"2011\"\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cli data-section-id=\"1tgbbq4\" data-start=\"2012\" data-end=\"2054\"\u003eTemperature measurement from \u003cstrong data-start=\"2043\" data-end=\"2054\"\u003e0–105°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17vgylw\" data-start=\"2055\" data-end=\"2089\"\u003e\n\u003cstrong data-start=\"2057\" data-end=\"2070\"\u003eAuto-Read\u003c\/strong\u003e endpoint detection\u003c\/li\u003e\n\u003cli data-section-id=\"1mwzo3f\" data-start=\"2090\" data-end=\"2112\"\u003eHigh\/low limit alarm\u003c\/li\u003e\n\u003cli data-section-id=\"ph843s\" data-start=\"2113\" data-end=\"2136\"\u003eCalibration-due alarm\u003c\/li\u003e\n\u003cli data-section-id=\"1qe41ro\" data-start=\"2137\" data-end=\"2158\"\u003ePassword protection\u003c\/li\u003e\n\u003cli data-section-id=\"15imnte\" data-start=\"2159\" data-end=\"2190\"\u003eMemory for \u003cstrong data-start=\"2172\" data-end=\"2190\"\u003e1000 data sets\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uefnfy\" data-start=\"2191\" data-end=\"2217\"\u003eBuilt-in real-time clock\u003c\/li\u003e\n\u003cli data-section-id=\"11i4skz\" data-start=\"2218\" data-end=\"2238\"\u003e\u003cstrong data-start=\"2220\" data-end=\"2238\"\u003e7-inch TFT LCD\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1forz9l\" data-start=\"2239\" data-end=\"2265\"\u003eBuilt-in thermal printer\u003c\/li\u003e\n\u003cli data-section-id=\"1kp79ik\" data-start=\"2266\" data-end=\"2341\"\u003eRS-compatible data transfer through the specified interface configuration\u003c\/li\u003e\n\u003cli data-section-id=\"10p0d2a\" data-start=\"2342\" data-end=\"2379\"\u003epH electrode and ATC probe supplied\u003c\/li\u003e\n\u003cli data-section-id=\"1k2edz5\" data-start=\"2380\" data-end=\"2406\"\u003eElectrode stand supplied\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2408\" data-end=\"2437\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2439\" data-end=\"3438\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2439\" data-end=\"2465\"\u003e\n\u003ctr data-start=\"2439\" data-end=\"2465\"\u003e\n\u003cth data-start=\"2439\" data-end=\"2455\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2455\" data-end=\"2465\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eLMPH15\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2476\" data-end=\"3438\"\u003e\n\u003ctr data-start=\"2476\" data-end=\"2524\"\u003e\n\u003ctd data-start=\"2476\" data-end=\"2491\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2491\" data-end=\"2524\"\u003epH Meter with Thermal Printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2525\" data-end=\"2543\"\u003e\n\u003ctd data-start=\"2525\" data-end=\"2533\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2533\" data-end=\"2543\"\u003eLMPH15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2544\" data-end=\"2563\"\u003e\n\u003ctd data-start=\"2544\" data-end=\"2552\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2552\" data-end=\"2563\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2564\" data-end=\"2598\"\u003e\n\u003ctd data-start=\"2564\" data-end=\"2575\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2575\" data-end=\"2598\" data-col-size=\"sm\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2599\" data-end=\"2642\"\u003e\n\u003ctd data-start=\"2599\" data-end=\"2615\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2615\" data-end=\"2642\"\u003e0.001 \/ 0.01 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2643\" data-end=\"2670\"\u003e\n\u003ctd data-start=\"2643\" data-end=\"2657\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2657\" data-end=\"2670\" data-col-size=\"sm\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2671\" data-end=\"2710\"\u003e\n\u003ctd data-start=\"2671\" data-end=\"2692\" data-col-size=\"sm\"\u003eCalibration Points\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2692\" data-end=\"2710\"\u003eUp to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2711\" data-end=\"2762\"\u003e\n\u003ctd data-start=\"2711\" data-end=\"2731\" data-col-size=\"sm\"\u003epH Buffer Options\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2731\" data-end=\"2762\"\u003eUSA, NIST, DIN, User Define\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2763\" data-end=\"2792\"\u003e\n\u003ctd data-start=\"2763\" data-end=\"2780\" data-col-size=\"sm\"\u003eORP \/ mV Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2780\" data-end=\"2792\"\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2793\" data-end=\"2819\"\u003e\n\u003ctd data-start=\"2793\" data-end=\"2808\" data-col-size=\"sm\"\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2808\" data-end=\"2819\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2820\" data-end=\"2847\"\u003e\n\u003ctd data-start=\"2820\" data-end=\"2837\" data-col-size=\"sm\"\u003eORP Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2837\" data-end=\"2847\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2848\" data-end=\"2890\"\u003e\n\u003ctd data-start=\"2848\" data-end=\"2868\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2868\" data-end=\"2890\"\u003e0–105°C \/ 32–221°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2891\" data-end=\"2933\"\u003e\n\u003ctd data-start=\"2891\" data-end=\"2914\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2914\" data-end=\"2933\" data-col-size=\"sm\"\u003e±0.5°C \/ ±0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2934\" data-end=\"2976\"\u003e\n\u003ctd data-start=\"2934\" data-end=\"2959\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2959\" data-end=\"2976\" data-col-size=\"sm\"\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2977\" data-end=\"3035\"\u003e\n\u003ctd data-start=\"2977\" data-end=\"3004\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3004\" data-end=\"3035\"\u003e0–100°C, Manual \/ Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3036\" data-end=\"3065\"\u003e\n\u003ctd data-start=\"3036\" data-end=\"3054\" data-col-size=\"sm\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3054\" data-end=\"3065\"\u003e\u0026lt;10¹² Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3066\" data-end=\"3107\"\u003e\n\u003ctd data-start=\"3066\" data-end=\"3078\" data-col-size=\"sm\"\u003eStability\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3078\" data-end=\"3107\"\u003eStandard or High Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3108\" data-end=\"3152\"\u003e\n\u003ctd data-start=\"3108\" data-end=\"3132\" data-col-size=\"sm\"\u003eCalibration Due Alarm\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3132\" data-end=\"3152\"\u003e1–31 days or Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3153\" data-end=\"3192\"\u003e\n\u003ctd data-start=\"3153\" data-end=\"3175\" data-col-size=\"sm\"\u003ePassword Protection\u003c\/td\u003e\n\u003ctd data-start=\"3175\" data-end=\"3192\" data-col-size=\"sm\"\u003eYes, 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3193\" data-end=\"3225\"\u003e\n\u003ctd data-start=\"3193\" data-end=\"3207\" data-col-size=\"sm\"\u003eData Memory\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3207\" data-end=\"3225\"\u003e1000 data sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3226\" data-end=\"3245\"\u003e\n\u003ctd data-start=\"3226\" data-end=\"3238\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"3238\" data-end=\"3245\" data-col-size=\"sm\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3246\" data-end=\"3274\"\u003e\n\u003ctd data-start=\"3246\" data-end=\"3256\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3256\" data-end=\"3274\"\u003e7-inch TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3275\" data-end=\"3305\"\u003e\n\u003ctd data-start=\"3275\" data-end=\"3293\" data-col-size=\"sm\"\u003eThermal Printer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3293\" data-end=\"3305\"\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3306\" data-end=\"3346\"\u003e\n\u003ctd data-start=\"3306\" data-end=\"3314\" data-col-size=\"sm\"\u003ePower\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3314\" data-end=\"3346\"\u003eDC Adaptor, AC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3347\" data-end=\"3390\"\u003e\n\u003ctd data-start=\"3347\" data-end=\"3368\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"3368\" data-end=\"3390\" data-col-size=\"sm\"\u003e330 × 235 × 420 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3391\" data-end=\"3414\"\u003e\n\u003ctd data-start=\"3391\" data-end=\"3406\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3406\" data-end=\"3414\" data-col-size=\"sm\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3415\" data-end=\"3438\"\u003e\n\u003ctd data-start=\"3415\" data-end=\"3426\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"3426\" data-end=\"3438\" data-col-size=\"sm\"\u003e90275090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3440\" data-end=\"3457\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3459\" data-end=\"3486\"\u003eThe LMPH15 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3488\" data-end=\"3834\"\u003e\n\u003cli data-section-id=\"vxg56i\" data-start=\"3488\" data-end=\"3504\"\u003epH measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1jj5gb3\" data-start=\"3505\" data-end=\"3522\"\u003eORP measurement\u003c\/li\u003e\n\u003cli data-section-id=\"e7atm0\" data-start=\"3523\" data-end=\"3549\"\u003eLaboratory water testing\u003c\/li\u003e\n\u003cli data-section-id=\"o1eo2v\" data-start=\"3550\" data-end=\"3578\"\u003eChemical solution analysis\u003c\/li\u003e\n\u003cli data-section-id=\"16yj6ii\" data-start=\"3579\" data-end=\"3614\"\u003ePharmaceutical laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"tjpn4h\" data-start=\"3615\" data-end=\"3653\"\u003eFood and beverage laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"1bajev5\" data-start=\"3654\" data-end=\"3689\"\u003eEnvironmental laboratory analysis\u003c\/li\u003e\n\u003cli data-section-id=\"kh6azt\" data-start=\"3690\" data-end=\"3716\"\u003eResearch and development\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3717\" data-end=\"3747\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"131qxe7\" data-start=\"3748\" data-end=\"3774\"\u003eAcademic laboratory work\u003c\/li\u003e\n\u003cli data-section-id=\"bk4gdd\" data-start=\"3775\" data-end=\"3834\"\u003eRoutine analytical measurements requiring printed records\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3836\" data-end=\"3853\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3855\" data-end=\"3882\"\u003eThe LMPH15 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3884\" data-end=\"4197\"\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3884\" data-end=\"3913\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3914\" data-end=\"3937\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"3938\" data-end=\"3970\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1fs6tb7\" data-start=\"3971\" data-end=\"3999\"\u003eWater-testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1iu5xdh\" data-start=\"4000\" data-end=\"4028\"\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"4029\" data-end=\"4052\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"rlkbyw\" data-start=\"4053\" data-end=\"4082\"\u003eQuality-control departments\u003c\/li\u003e\n\u003cli data-section-id=\"nyl6ft\" data-start=\"4083\" data-end=\"4110\"\u003eColleges and universities\u003c\/li\u003e\n\u003cli data-section-id=\"jpgyqj\" data-start=\"4111\" data-end=\"4133\"\u003eTesting laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"37uz9i\" data-start=\"4134\" data-end=\"4197\"\u003eIndustrial laboratories requiring printed measurement records\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"6852\" data-end=\"6862\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"7ayjym\" dir=\"auto\" data-start=\"6864\" data-end=\"6899\"\u003e1. What is the LMPH15 used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6901\" data-end=\"7023\"\u003eThe LMPH15 is a benchtop laboratory meter for \u003cstrong data-start=\"6947\" data-end=\"6986\"\u003epH, ORP and temperature measurement\u003c\/strong\u003e, with an integrated thermal printer.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxtlr5\" dir=\"auto\" data-start=\"7025\" data-end=\"7065\"\u003e2. What is the pH measurement range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7067\" data-end=\"7107\"\u003eThe pH range is \u003cstrong data-start=\"7083\" data-end=\"7106\"\u003e-2.000 to 20.000 pH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"fmpnzc\" dir=\"auto\" data-start=\"7109\" data-end=\"7140\"\u003e3. What is the pH accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7142\" data-end=\"7182\"\u003eThe specified accuracy is \u003cstrong data-start=\"7168\" data-end=\"7181\"\u003e±0.002 pH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hnux5e\" dir=\"auto\" data-start=\"7184\" data-end=\"7233\"\u003e4. How many calibration points are available?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7235\" data-end=\"7288\"\u003eThe LMPH15 supports \u003cstrong data-start=\"7255\" data-end=\"7287\"\u003eup to 5-point pH calibration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"10kk0on\" dir=\"auto\" data-start=\"7290\" data-end=\"7337\"\u003e5. Which pH buffer standards are supported?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7339\" data-end=\"7414\"\u003eThe instrument supports \u003cstrong data-start=\"7363\" data-end=\"7398\"\u003eUSA, NIST, DIN and user-defined\u003c\/strong\u003e buffer options.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1wj5lbu\" dir=\"auto\" data-start=\"7416\" data-end=\"7445\"\u003e6. What is the ORP range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7447\" data-end=\"7529\"\u003eThe ORP\/mV range is \u003cstrong data-start=\"7467\" data-end=\"7479\"\u003e±2000 mV\u003c\/strong\u003e, with \u003cstrong data-start=\"7486\" data-end=\"7507\"\u003e0.1 mV resolution\u003c\/strong\u003e and ±0.2 mV accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1myd11r\" dir=\"auto\" data-start=\"7531\" data-end=\"7597\"\u003e7. Does the LMPH15 provide automatic temperature compensation?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7599\" data-end=\"7695\"\u003eYes. Temperature compensation is available from \u003cstrong data-start=\"7647\" data-end=\"7658\"\u003e0–100°C\u003c\/strong\u003e, with manual or automatic operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"tah1z1\" dir=\"auto\" data-start=\"7697\" data-end=\"7759\"\u003e8. Does the instrument have automatic electrode diagnosis?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7761\" data-end=\"7837\"\u003eYes. The electrode diagnosis function displays \u003cstrong data-start=\"7808\" data-end=\"7836\"\u003epH slope and zero offset\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"18bswui\" dir=\"auto\" data-start=\"7839\" data-end=\"7881\"\u003e9. How much data can the LMPH15 store?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7883\" data-end=\"7935\"\u003eThe internal memory stores up to \u003cstrong data-start=\"7916\" data-end=\"7934\"\u003e1000 data sets\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16u9qsu\" dir=\"auto\" data-start=\"7937\" data-end=\"7987\"\u003e10. Does the LMPH15 print measurement results?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7989\" data-end=\"8085\"\u003eYes. It has a \u003cstrong data-start=\"8003\" data-end=\"8031\"\u003ebuilt-in thermal printer\u003c\/strong\u003e for printing measurement and calibration information.\u003c\/p\u003e\n\u003ch3 data-section-id=\"psdyj5\" dir=\"auto\" data-start=\"8087\" data-end=\"8139\"\u003e11. Does the LMPH15 have a calibration reminder?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8141\" data-end=\"8228\"\u003eYes. The calibration-due alarm can be configured from \u003cstrong data-start=\"8195\" data-end=\"8227\"\u003e1 to 31 days or switched off\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13myqh8\" dir=\"auto\" data-start=\"8230\" data-end=\"8268\"\u003e12. What accessories are supplied?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8270\" data-end=\"8457\"\u003eThe standard accessories include the \u003cstrong data-start=\"8307\" data-end=\"8456\"\u003emain instrument, pH electrode, pH buffer solutions, ATC probe, electrode stand, printer, printer adaptor, instruction manual and test certificate\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":50202883752233,"sku":"LMPH15","price":62799.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/pHMeter-WithPrinter.jpg?v=1777307344","url":"https:\/\/www.labmart.in\/products\/labmart-lmph15-ph-meter-with-thermal-printer","provider":"Labmart.in","version":"1.0","type":"link"}