{"product_id":"labmart-lmph12-benchtop-ph-meter","title":"pH Meter-5 Points-LMPH12","description":"\u003cp dir=\"auto\" data-start=\"122\" data-end=\"442\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"126\" data-end=\"172\"\u003eLabmart LMPH12 Benchtop pH \/ mV \/ °C Meter\u003c\/strong\u003e is a high-precision laboratory meter for pH, millivolt and temperature measurement. It provides \u003cstrong data-start=\"269\" data-end=\"441\"\u003eup to 5-point pH calibration, automatic buffer recognition, automatic temperature compensation, ±1999 mV measurement, 500-reading memory and a large backlit LCD display\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"444\" data-end=\"477\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"479\" data-end=\"498\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"500\" data-end=\"728\"\u003eThe \u003cstrong data-start=\"504\" data-end=\"542\"\u003eLMPH12 Benchtop pH \/ mV \/ °C Meter\u003c\/strong\u003e is designed for accurate laboratory measurement of \u003cstrong data-start=\"594\" data-end=\"631\"\u003epH, ORP\/millivolt and temperature\u003c\/strong\u003e. It features a large backlit LCD display with measurement prompts to simplify routine operation.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"730\" data-end=\"988\"\u003eIn pH mode, the meter supports \u003cstrong data-start=\"761\" data-end=\"836\"\u003eup to 5-point push-button calibration with automatic buffer recognition\u003c\/strong\u003e and selectable USA, NIST, DIN or user-defined buffer standards. The instrument automatically calculates and displays electrode slope after calibration.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"990\" data-end=\"1194\"\u003eFor ORP measurements, the LMPH12 provides \u003cstrong data-start=\"1032\" data-end=\"1078\"\u003eabsolute or relative millivolt measurement\u003c\/strong\u003e and single-point offset calibration. Automatic endpoint functionality freezes stable readings for easier recording.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1196\" data-end=\"1408\"\u003eThe meter also includes configurable stability conditions, selectable measurement resolution, temperature units, date\/time settings, calibration reminders and memory for \u003cstrong data-start=\"1366\" data-end=\"1407\"\u003eup to 500 readings with date and time\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1410\" data-end=\"1436\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1438\" data-end=\"2144\"\u003e\n\u003cli data-section-id=\"1mym54q\" data-start=\"1438\" data-end=\"1471\"\u003eBenchtop \u003cstrong data-start=\"1449\" data-end=\"1471\"\u003epH \/ mV \/ °C meter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jgwxiq\" data-start=\"1472\" data-end=\"1521\"\u003epH measurement range of \u003cstrong data-start=\"1498\" data-end=\"1521\"\u003e-2.000 to 20.000 pH\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"133uf4g\" data-start=\"1522\" data-end=\"1556\"\u003e\u003cstrong data-start=\"1524\" data-end=\"1556\"\u003eUp to 5-point pH calibration\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"5ahpki\" data-start=\"1557\" data-end=\"1587\"\u003eAutomatic buffer recognition\u003c\/li\u003e\n\u003cli data-section-id=\"1v93olm\" data-start=\"1588\" data-end=\"1636\"\u003eUSA, NIST, DIN and user-defined buffer options\u003c\/li\u003e\n\u003cli data-section-id=\"1l58xq6\" data-start=\"1637\" data-end=\"1676\"\u003eAutomatic electrode slope calculation\u003c\/li\u003e\n\u003cli data-section-id=\"1aoq1y2\" data-start=\"1677\" data-end=\"1723\"\u003e\u003cstrong data-start=\"1679\" data-end=\"1723\"\u003eAutomatic Temperature Compensation (ATC)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"u934vb\" data-start=\"1724\" data-end=\"1763\"\u003eORP\/mV measurement up to \u003cstrong data-start=\"1751\" data-end=\"1763\"\u003e±1999 mV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kq2zdy\" data-start=\"1764\" data-end=\"1809\"\u003eAbsolute and relative millivolt measurement\u003c\/li\u003e\n\u003cli data-section-id=\"42580p\" data-start=\"1810\" data-end=\"1847\"\u003eSingle-point ORP offset calibration\u003c\/li\u003e\n\u003cli data-section-id=\"1k6wqgk\" data-start=\"1848\" data-end=\"1877\"\u003eAutomatic endpoint function\u003c\/li\u003e\n\u003cli data-section-id=\"5yzgek\" data-start=\"1878\" data-end=\"1911\"\u003eSelectable pH and mV resolution\u003c\/li\u003e\n\u003cli data-section-id=\"174n6mt\" data-start=\"1912\" data-end=\"1938\"\u003eCalibration-due reminder\u003c\/li\u003e\n\u003cli data-section-id=\"1r7rfpn\" data-start=\"1939\" data-end=\"1982\"\u003e\u003cstrong data-start=\"1941\" data-end=\"1982\"\u003e500-reading memory with date and time\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"uefnfy\" data-start=\"1983\" data-end=\"2009\"\u003eBuilt-in real-time clock\u003c\/li\u003e\n\u003cli data-section-id=\"9jrx9a\" data-start=\"2010\" data-end=\"2037\"\u003eLarge backlit LCD display\u003c\/li\u003e\n\u003cli data-section-id=\"rcxxze\" data-start=\"2038\" data-end=\"2084\"\u003eAutomatic or manual temperature compensation\u003c\/li\u003e\n\u003cli data-section-id=\"178z56q\" data-start=\"2085\" data-end=\"2108\"\u003eConfigurable auto-off\u003c\/li\u003e\n\u003cli data-section-id=\"mfgaom\" data-start=\"2109\" data-end=\"2144\"\u003eReset-to-factory-default function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2146\" data-end=\"2175\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2177\" data-end=\"3076\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2177\" data-end=\"2203\"\u003e\n\u003ctr data-start=\"2177\" data-end=\"2203\"\u003e\n\u003cth data-start=\"2177\" data-end=\"2193\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2193\" data-end=\"2203\" data-col-size=\"md\" class=\"last:pe-10\"\u003eLMPH12\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2214\" data-end=\"3076\"\u003e\n\u003ctr data-start=\"2214\" data-end=\"2260\"\u003e\n\u003ctd data-start=\"2214\" data-end=\"2229\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2229\" data-end=\"2260\"\u003eBenchtop pH \/ mV \/ °C Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2261\" data-end=\"2279\"\u003e\n\u003ctd data-start=\"2261\" data-end=\"2269\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2269\" data-end=\"2279\" data-col-size=\"md\"\u003eLMPH12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2280\" data-end=\"2299\"\u003e\n\u003ctd data-start=\"2280\" data-end=\"2288\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2288\" data-end=\"2299\" data-col-size=\"md\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2300\" data-end=\"2334\"\u003e\n\u003ctd data-start=\"2300\" data-end=\"2311\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2311\" data-end=\"2334\" data-col-size=\"md\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2335\" data-end=\"2362\"\u003e\n\u003ctd data-start=\"2335\" data-end=\"2349\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2349\" data-end=\"2362\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2363\" data-end=\"2416\"\u003e\n\u003ctd data-start=\"2363\" data-end=\"2379\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2379\" data-end=\"2416\" data-col-size=\"md\"\u003e0.001 \/ 0.01 \/ 0.1 pH, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2417\" data-end=\"2440\"\u003e\n\u003ctd data-start=\"2417\" data-end=\"2428\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"2428\" data-end=\"2440\" data-col-size=\"md\"\u003e±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2441\" data-end=\"2466\"\u003e\n\u003ctd data-start=\"2441\" data-end=\"2455\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2455\" data-end=\"2466\" data-col-size=\"md\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2467\" data-end=\"2509\"\u003e\n\u003ctd data-start=\"2467\" data-end=\"2483\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2483\" data-end=\"2509\" data-col-size=\"md\"\u003e0.1 \/ 1 mV, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2510\" data-end=\"2545\"\u003e\n\u003ctd data-start=\"2510\" data-end=\"2527\" data-col-size=\"sm\"\u003epH Calibration\u003c\/td\u003e\n\u003ctd data-start=\"2527\" data-end=\"2545\" data-col-size=\"md\"\u003eUp to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2546\" data-end=\"2599\"\u003e\n\u003ctd data-start=\"2546\" data-end=\"2565\" data-col-size=\"sm\"\u003eBuffer Standards\u003c\/td\u003e\n\u003ctd data-start=\"2565\" data-end=\"2599\" data-col-size=\"md\"\u003eUSA \/ NIST \/ DIN \/ User Define\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2600\" data-end=\"2647\"\u003e\n\u003ctd data-start=\"2600\" data-end=\"2627\" data-col-size=\"sm\"\u003eCalibration Due Reminder\u003c\/td\u003e\n\u003ctd data-start=\"2627\" data-end=\"2647\" data-col-size=\"md\"\u003e1–30 days or Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2648\" data-end=\"2690\"\u003e\n\u003ctd data-start=\"2648\" data-end=\"2668\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2668\" data-end=\"2690\" data-col-size=\"md\"\u003e0–105°C \/ 32–212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2691\" data-end=\"2733\"\u003e\n\u003ctd data-start=\"2691\" data-end=\"2714\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2714\" data-end=\"2733\" data-col-size=\"md\"\u003e±0.5°C \/ ±0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2734\" data-end=\"2804\"\u003e\n\u003ctd data-start=\"2734\" data-end=\"2761\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"2761\" data-end=\"2804\" data-col-size=\"md\"\u003e0–100°C \/ 32–212°F, Automatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2805\" data-end=\"2861\"\u003e\n\u003ctd data-start=\"2805\" data-end=\"2816\" data-col-size=\"sm\"\u003eAuto-Off\u003c\/td\u003e\n\u003ctd data-start=\"2816\" data-end=\"2861\" data-col-size=\"md\"\u003eManual or Automatic; 10, 20 or 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2862\" data-end=\"2904\"\u003e\n\u003ctd data-start=\"2862\" data-end=\"2871\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2871\" data-end=\"2904\" data-col-size=\"md\"\u003e500 readings with date \u0026amp; time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2905\" data-end=\"2936\"\u003e\n\u003ctd data-start=\"2905\" data-end=\"2915\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2915\" data-end=\"2936\" data-col-size=\"md\"\u003eLarge Backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2937\" data-end=\"2984\"\u003e\n\u003ctd data-start=\"2937\" data-end=\"2952\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2952\" data-end=\"2984\" data-col-size=\"md\"\u003eDC Adaptor, AC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2985\" data-end=\"3028\"\u003e\n\u003ctd data-start=\"2985\" data-end=\"3006\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"3006\" data-end=\"3028\" data-col-size=\"md\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3029\" data-end=\"3052\"\u003e\n\u003ctd data-start=\"3029\" data-end=\"3044\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3044\" data-end=\"3052\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3053\" data-end=\"3076\"\u003e\n\u003ctd data-start=\"3053\" data-end=\"3064\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"3064\" data-end=\"3076\" data-col-size=\"md\"\u003e90275090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3078\" data-end=\"3095\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3097\" data-end=\"3124\"\u003eThe LMPH12 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3126\" data-end=\"3439\"\u003e\n\u003cli data-section-id=\"vxg56i\" data-start=\"3126\" data-end=\"3142\"\u003epH measurement\u003c\/li\u003e\n\u003cli data-section-id=\"o5lhnf\" data-start=\"3143\" data-end=\"3163\"\u003eORP\/mV measurement\u003c\/li\u003e\n\u003cli data-section-id=\"27xnfy\" data-start=\"3164\" data-end=\"3189\"\u003eTemperature measurement\u003c\/li\u003e\n\u003cli data-section-id=\"qeh43v\" data-start=\"3190\" data-end=\"3213\"\u003eWater-quality testing\u003c\/li\u003e\n\u003cli data-section-id=\"xufp6l\" data-start=\"3214\" data-end=\"3244\"\u003eChemical laboratory analysis\u003c\/li\u003e\n\u003cli data-section-id=\"16yj6ii\" data-start=\"3245\" data-end=\"3280\"\u003ePharmaceutical laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"1qk70oi\" data-start=\"3281\" data-end=\"3308\"\u003eFood and beverage testing\u003c\/li\u003e\n\u003cli data-section-id=\"1bajev5\" data-start=\"3309\" data-end=\"3344\"\u003eEnvironmental laboratory analysis\u003c\/li\u003e\n\u003cli data-section-id=\"kh6azt\" data-start=\"3345\" data-end=\"3371\"\u003eResearch and development\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3372\" data-end=\"3402\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1q5aoag\" data-start=\"3403\" data-end=\"3439\"\u003eAcademic and teaching laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3441\" data-end=\"3458\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3460\" data-end=\"3487\"\u003eThe LMPH12 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3489\" data-end=\"3776\"\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3489\" data-end=\"3512\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3513\" data-end=\"3542\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"3543\" data-end=\"3575\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1iu5xdh\" data-start=\"3576\" data-end=\"3604\"\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1fs6tb7\" data-start=\"3605\" data-end=\"3633\"\u003eWater-testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1t31nfa\" data-start=\"3634\" data-end=\"3657\"\u003eResearch institutions\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3658\" data-end=\"3688\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"nyl6ft\" data-start=\"3689\" data-end=\"3716\"\u003eColleges and universities\u003c\/li\u003e\n\u003cli data-section-id=\"10vtoei\" data-start=\"3717\" data-end=\"3742\"\u003eIndustrial laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1magj83\" data-start=\"3743\" data-end=\"3776\"\u003eGeneral analytical laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"6156\" data-end=\"6166\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1jgd1l5\" dir=\"auto\" data-start=\"6168\" data-end=\"6203\"\u003e1. What is the LMPH12 used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6205\" data-end=\"6289\"\u003eThe LMPH12 is a benchtop meter for measuring \u003cstrong data-start=\"6250\" data-end=\"6288\"\u003epH, millivolts\/ORP and temperature\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxtlr5\" dir=\"auto\" data-start=\"6291\" data-end=\"6331\"\u003e2. What is the pH measurement range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6333\" data-end=\"6373\"\u003eThe pH range is \u003cstrong data-start=\"6349\" data-end=\"6372\"\u003e-2.000 to 20.000 pH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"fmpnzc\" dir=\"auto\" data-start=\"6375\" data-end=\"6406\"\u003e3. What is the pH accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6408\" data-end=\"6451\"\u003eThe specified pH accuracy is \u003cstrong data-start=\"6437\" data-end=\"6450\"\u003e±0.002 pH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xm8mlo\" dir=\"auto\" data-start=\"6453\" data-end=\"6512\"\u003e4. How many calibration points does the LMPH12 support?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6514\" data-end=\"6559\"\u003eIt supports \u003cstrong data-start=\"6526\" data-end=\"6558\"\u003eup to 5-point pH calibration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1fgjz6i\" dir=\"auto\" data-start=\"6561\" data-end=\"6620\"\u003e5. Does it automatically recognize calibration buffers?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6622\" data-end=\"6681\"\u003eYes. The pH mode provides \u003cstrong data-start=\"6648\" data-end=\"6680\"\u003eautomatic buffer recognition\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mn0s7g\" dir=\"auto\" data-start=\"6683\" data-end=\"6727\"\u003e6. Which buffer standards are supported?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6729\" data-end=\"6801\"\u003eThe meter supports \u003cstrong data-start=\"6748\" data-end=\"6800\"\u003eUSA, NIST, DIN and user-defined buffer standards\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mqj589\" dir=\"auto\" data-start=\"6803\" data-end=\"6868\"\u003e7. Does the meter provide automatic temperature compensation?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6870\" data-end=\"6950\"\u003eYes. ATC is available, with temperature compensation specified from \u003cstrong data-start=\"6938\" data-end=\"6949\"\u003e0–100°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11qjcx4\" dir=\"auto\" data-start=\"6952\" data-end=\"6992\"\u003e8. What is the mV measurement range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6994\" data-end=\"7023\"\u003eThe mV range is \u003cstrong data-start=\"7010\" data-end=\"7022\"\u003e±1999 mV\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"124m55g\" dir=\"auto\" data-start=\"7025\" data-end=\"7059\"\u003e9. Can the LMPH12 measure ORP?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7061\" data-end=\"7181\"\u003eYes. The meter supports ORP measurement through its mV functions, including absolute and relative millivolt measurement.\u003c\/p\u003e\n\u003ch3 data-section-id=\"a35be4\" dir=\"auto\" data-start=\"7183\" data-end=\"7223\"\u003e10. How many readings can be stored?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7225\" data-end=\"7288\"\u003eThe memory can store \u003cstrong data-start=\"7246\" data-end=\"7287\"\u003eup to 500 readings with date and time\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kxj3rb\" dir=\"auto\" data-start=\"7290\" data-end=\"7341\"\u003e11. Does the meter have a calibration reminder?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7343\" data-end=\"7429\"\u003eYes. The calibration reminder can be configured from \u003cstrong data-start=\"7396\" data-end=\"7428\"\u003e1 to 30 days or switched off\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13myqh8\" dir=\"auto\" data-start=\"7431\" data-end=\"7469\"\u003e12. What accessories are supplied?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7471\" data-end=\"7654\"\u003eStandard accessories include the \u003cstrong data-start=\"7504\" data-end=\"7653\"\u003epH meter, pH electrode, pH 4.01\/7.00\/10.01 buffers, temperature probe, electrode stand, 5V power adaptor, instruction manual and test certificate\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch1 data-section-id=\"1onnmjw\" dir=\"auto\" data-start=\"7656\" data-end=\"7676\"\u003e\u003cbr\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":50202957545769,"sku":"LMPH12","price":37500.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/pHMeter-5Points.jpg?v=1777307538","url":"https:\/\/www.labmart.in\/products\/labmart-lmph12-benchtop-ph-meter","provider":"Labmart.in","version":"1.0","type":"link"}