{"product_id":"labmart-lmmp32-water-quality-multiparameter","title":"Water Quality Multiparameter-LMMP32","description":"\u003cp dir=\"auto\" data-start=\"176\" data-end=\"604\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"180\" data-end=\"227\"\u003eLabmart LMMP32 Water Quality Multiparameter\u003c\/strong\u003e is a laboratory benchtop meter offering \u003cstrong data-start=\"268\" data-end=\"291\"\u003e9 measurement modes\u003c\/strong\u003e: pH, ORP, Ion, Dissolved Oxygen, Conductivity, TDS, Salinity, Resistivity and Temperature. It features automatic temperature compensation, up to 5-point calibration for pH and conductivity-related modes, automatic endpoint, 500-data memory with date\/time, electrode diagnosis and selectable measurement settings.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"606\" data-end=\"639\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"641\" data-end=\"660\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"662\" data-end=\"865\"\u003eThe \u003cstrong data-start=\"666\" data-end=\"705\"\u003eLMMP32 Water Quality Multiparameter\u003c\/strong\u003e is a multi-function laboratory instrument designed for comprehensive water-quality measurement. The system combines \u003cstrong data-start=\"822\" data-end=\"848\"\u003enine measurement modes\u003c\/strong\u003e in one platform:\u003c\/p\u003e\n\u003cul data-start=\"867\" data-end=\"967\"\u003e\n\u003cli data-section-id=\"yhmt8w\" data-start=\"867\" data-end=\"871\"\u003epH\u003c\/li\u003e\n\u003cli data-section-id=\"1o4aqt\" data-start=\"872\" data-end=\"877\"\u003eORP\u003c\/li\u003e\n\u003cli data-section-id=\"1o49q8\" data-start=\"878\" data-end=\"883\"\u003eIon\u003c\/li\u003e\n\u003cli data-section-id=\"i8auk9\" data-start=\"884\" data-end=\"907\"\u003eDissolved Oxygen (DO)\u003c\/li\u003e\n\u003cli data-section-id=\"1ee4zrr\" data-start=\"908\" data-end=\"922\"\u003eConductivity\u003c\/li\u003e\n\u003cli data-section-id=\"1o4rxn\" data-start=\"923\" data-end=\"928\"\u003eTDS\u003c\/li\u003e\n\u003cli data-section-id=\"53y039\" data-start=\"929\" data-end=\"939\"\u003eSalinity\u003c\/li\u003e\n\u003cli data-section-id=\"ekn3zt\" data-start=\"940\" data-end=\"953\"\u003eResistivity\u003c\/li\u003e\n\u003cli data-section-id=\"1f3vflw\" data-start=\"954\" data-end=\"967\"\u003eTemperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"969\" data-end=\"1248\"\u003eThe instrument provides selectable measurement resolutions, configurable calibration settings and \u003cstrong data-start=\"1067\" data-end=\"1111\"\u003eAutomatic Temperature Compensation (ATC)\u003c\/strong\u003e. An automatic endpoint function freezes stable readings for easier recording, while the built-in real-time clock timestamps stored data.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1250\" data-end=\"1471\"\u003eThe LMMP32 can store and recall \u003cstrong data-start=\"1282\" data-end=\"1304\"\u003eup to 500 readings\u003c\/strong\u003e and provides a setup menu for configuring calibration points, measurement stability conditions, temperature units and date\/time. \u003cspan class=\"contents\" data-content-reference-start=\"1434\" data-content-reference-end=\"1464\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1473\" data-end=\"1499\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1501\" data-end=\"2369\"\u003e\n\u003cli data-section-id=\"cxu67\" data-start=\"1501\" data-end=\"1542\"\u003e\u003cstrong data-start=\"1503\" data-end=\"1542\"\u003e9-in-1 water quality multiparameter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1038ylx\" data-start=\"1543\" data-end=\"1625\"\u003epH, ORP, Ion, DO, Conductivity, TDS, Salinity, Resistivity and Temperature modes\u003c\/li\u003e\n\u003cli data-section-id=\"tv2t0r\" data-start=\"1626\" data-end=\"1665\"\u003eSelectable °C or °F temperature units\u003c\/li\u003e\n\u003cli data-section-id=\"qatumy\" data-start=\"1666\" data-end=\"1708\"\u003eAutomatic Temperature Compensation (ATC)\u003c\/li\u003e\n\u003cli data-section-id=\"1k6wqgk\" data-start=\"1709\" data-end=\"1738\"\u003eAutomatic endpoint function\u003c\/li\u003e\n\u003cli data-section-id=\"313vjl\" data-start=\"1739\" data-end=\"1777\"\u003eHelp messages for operating guidance\u003c\/li\u003e\n\u003cli data-section-id=\"11kjrur\" data-start=\"1778\" data-end=\"1827\"\u003eCustomizable calibration and stability settings\u003c\/li\u003e\n\u003cli data-section-id=\"1r9lmln\" data-start=\"1828\" data-end=\"1852\"\u003eFactory reset function\u003c\/li\u003e\n\u003cli data-section-id=\"x0t3kz\" data-start=\"1853\" data-end=\"1877\"\u003e\u003cstrong data-start=\"1855\" data-end=\"1877\"\u003e500-reading memory\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1q56fxh\" data-start=\"1878\" data-end=\"1924\"\u003eReal-time clock with date\/time data stamping\u003c\/li\u003e\n\u003cli data-section-id=\"1jjhma6\" data-start=\"1925\" data-end=\"1960\"\u003epH calibration up to \u003cstrong data-start=\"1948\" data-end=\"1960\"\u003e5 points\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"213dai\" data-start=\"1961\" data-end=\"1994\"\u003eAutomatic pH buffer recognition\u003c\/li\u003e\n\u003cli data-section-id=\"12rpf5c\" data-start=\"1995\" data-end=\"2056\"\u003eSelectable USA, NIST, DIN and user-defined buffer standards\u003c\/li\u003e\n\u003cli data-section-id=\"1s9wasj\" data-start=\"2057\" data-end=\"2086\"\u003eElectrode slope calculation\u003c\/li\u003e\n\u003cli data-section-id=\"174n6mt\" data-start=\"2087\" data-end=\"2113\"\u003eCalibration-due reminder\u003c\/li\u003e\n\u003cli data-section-id=\"1n21u5j\" data-start=\"2114\" data-end=\"2153\"\u003eAbsolute and relative ORP measurement\u003c\/li\u003e\n\u003cli data-section-id=\"k8wg3t\" data-start=\"2154\" data-end=\"2188\"\u003eAdjustable TDS conversion factor\u003c\/li\u003e\n\u003cli data-section-id=\"h7kj3e\" data-start=\"2189\" data-end=\"2242\"\u003eLinear or pure-water temperature compensation modes\u003c\/li\u003e\n\u003cli data-section-id=\"ohdlkr\" data-start=\"2243\" data-end=\"2297\"\u003ePractical salinity or seawater measurement standards\u003c\/li\u003e\n\u003cli data-section-id=\"1r7tvao\" data-start=\"2298\" data-end=\"2322\"\u003eDO pressure correction\u003c\/li\u003e\n\u003cli data-section-id=\"rcxxze\" data-start=\"2323\" data-end=\"2369\"\u003eAutomatic or manual temperature compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2371\" data-end=\"2400\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2402\" data-end=\"4762\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2402\" data-end=\"2428\"\u003e\n\u003ctr data-start=\"2402\" data-end=\"2428\"\u003e\n\u003cth data-start=\"2402\" data-end=\"2418\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2418\" data-end=\"2428\" data-col-size=\"md\" class=\"last:pe-10\"\u003eLMMP32\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2439\" data-end=\"4762\"\u003e\n\u003ctr data-start=\"2439\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2439\" data-end=\"2454\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2454\" data-end=\"2492\" data-col-size=\"md\"\u003eWater Quality Multiparameter Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2511\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2501\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2501\" data-end=\"2511\" data-col-size=\"md\"\u003eLMMP32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2512\" data-end=\"2531\"\u003e\n\u003ctd data-start=\"2512\" data-end=\"2520\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2520\" data-end=\"2531\" data-col-size=\"md\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2532\" data-end=\"2562\"\u003e\n\u003ctd data-start=\"2532\" data-end=\"2552\" data-col-size=\"sm\"\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd data-start=\"2552\" data-end=\"2562\" data-col-size=\"md\"\u003e9-in-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2563\" data-end=\"2597\"\u003e\n\u003ctd data-start=\"2563\" data-end=\"2574\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2574\" data-end=\"2597\" data-col-size=\"md\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2598\" data-end=\"2651\"\u003e\n\u003ctd data-start=\"2598\" data-end=\"2614\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2614\" data-end=\"2651\" data-col-size=\"md\"\u003e0.001 \/ 0.01 \/ 0.1 pH, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2652\" data-end=\"2679\"\u003e\n\u003ctd data-start=\"2652\" data-end=\"2666\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2666\" data-end=\"2679\" data-col-size=\"md\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2680\" data-end=\"2715\"\u003e\n\u003ctd data-start=\"2680\" data-end=\"2697\" data-col-size=\"sm\"\u003epH Calibration\u003c\/td\u003e\n\u003ctd data-start=\"2697\" data-end=\"2715\" data-col-size=\"md\"\u003eUp to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2716\" data-end=\"2770\"\u003e\n\u003ctd data-start=\"2716\" data-end=\"2738\" data-col-size=\"sm\"\u003epH Buffer Standards\u003c\/td\u003e\n\u003ctd data-start=\"2738\" data-end=\"2770\" data-col-size=\"md\"\u003eUSA, NIST, DIN, User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2771\" data-end=\"2802\"\u003e\n\u003ctd data-start=\"2771\" data-end=\"2783\" data-col-size=\"sm\"\u003eORP Range\u003c\/td\u003e\n\u003ctd data-start=\"2783\" data-end=\"2802\" data-col-size=\"md\"\u003e0 to ±1999.9 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2803\" data-end=\"2846\"\u003e\n\u003ctd data-start=\"2803\" data-end=\"2820\" data-col-size=\"sm\"\u003eORP Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2820\" data-end=\"2846\" data-col-size=\"md\"\u003e0.1 \/ 1 mV, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2847\" data-end=\"2873\"\u003e\n\u003ctd data-start=\"2847\" data-end=\"2862\" data-col-size=\"sm\"\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2862\" data-end=\"2873\" data-col-size=\"md\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2874\" data-end=\"2922\"\u003e\n\u003ctd data-start=\"2874\" data-end=\"2892\" data-col-size=\"sm\"\u003eORP Calibration\u003c\/td\u003e\n\u003ctd data-start=\"2892\" data-end=\"2922\" data-col-size=\"md\"\u003e1-point offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2923\" data-end=\"2976\"\u003e\n\u003ctd data-start=\"2923\" data-end=\"2935\" data-col-size=\"sm\"\u003eIon Range\u003c\/td\u003e\n\u003ctd data-start=\"2935\" data-end=\"2976\" data-col-size=\"md\"\u003e0.00 to 19999, depending on ISE range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2977\" data-end=\"3025\"\u003e\n\u003ctd data-start=\"2977\" data-end=\"2994\" data-col-size=\"sm\"\u003eIon Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2994\" data-end=\"3025\"\u003e0.001 \/ 0.01 \/ 1, automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3026\" data-end=\"3066\"\u003e\n\u003ctd data-start=\"3026\" data-end=\"3041\" data-col-size=\"sm\"\u003eIon Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3041\" data-end=\"3066\" data-col-size=\"md\"\u003e±0.5%, ±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3067\" data-end=\"3120\"\u003e\n\u003ctd data-start=\"3067\" data-end=\"3090\" data-col-size=\"sm\"\u003eIon Measurement Mode\u003c\/td\u003e\n\u003ctd data-start=\"3090\" data-end=\"3120\" data-col-size=\"md\"\u003eAbsolute mV or Relative mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3121\" data-end=\"3157\"\u003e\n\u003ctd data-start=\"3121\" data-end=\"3142\" data-col-size=\"sm\"\u003eConductivity Range\u003c\/td\u003e\n\u003ctd data-start=\"3142\" data-end=\"3157\" data-col-size=\"md\"\u003e0–200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3158\" data-end=\"3202\"\u003e\n\u003ctd data-start=\"3158\" data-end=\"3184\" data-col-size=\"sm\"\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3184\" data-end=\"3202\" data-col-size=\"md\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3203\" data-end=\"3247\"\u003e\n\u003ctd data-start=\"3203\" data-end=\"3227\" data-col-size=\"sm\"\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3227\" data-end=\"3247\"\u003e±0.5% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3248\" data-end=\"3294\"\u003e\n\u003ctd data-start=\"3248\" data-end=\"3264\" data-col-size=\"sm\"\u003eCell Constant\u003c\/td\u003e\n\u003ctd data-start=\"3264\" data-end=\"3294\" data-col-size=\"md\"\u003e0.1 \/ 1 \/ 10, user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3295\" data-end=\"3341\"\u003e\n\u003ctd data-start=\"3295\" data-end=\"3321\" data-col-size=\"sm\"\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd data-start=\"3321\" data-end=\"3341\" data-col-size=\"md\"\u003e0.0–10.0% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3342\" data-end=\"3387\"\u003e\n\u003ctd data-start=\"3342\" data-end=\"3369\" data-col-size=\"sm\"\u003eConductivity Calibration\u003c\/td\u003e\n\u003ctd data-start=\"3369\" data-end=\"3387\" data-col-size=\"md\"\u003eUp to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3388\" data-end=\"3474\"\u003e\n\u003ctd data-start=\"3388\" data-end=\"3412\" data-col-size=\"sm\"\u003eCalibration Solutions\u003c\/td\u003e\n\u003ctd data-start=\"3412\" data-end=\"3474\" data-col-size=\"md\"\u003e10 µS\/cm, 84 µS\/cm, 1413 µS\/cm, 12.88 mS\/cm*, 111.8 mS\/cm*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3475\" data-end=\"3520\"\u003e\n\u003ctd data-start=\"3475\" data-end=\"3496\" data-col-size=\"sm\"\u003eCompensation Modes\u003c\/td\u003e\n\u003ctd data-start=\"3496\" data-end=\"3520\" data-col-size=\"md\"\u003eLinear or Pure Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3521\" data-end=\"3590\"\u003e\n\u003ctd data-start=\"3521\" data-end=\"3533\" data-col-size=\"sm\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd data-start=\"3533\" data-end=\"3590\" data-col-size=\"md\"\u003e0–10 ppt; maximum 200 ppt depending on factor setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3591\" data-end=\"3626\"\u003e\n\u003ctd data-start=\"3591\" data-end=\"3608\" data-col-size=\"sm\"\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3608\" data-end=\"3626\" data-col-size=\"md\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3627\" data-end=\"3660\"\u003e\n\u003ctd data-start=\"3627\" data-end=\"3642\" data-col-size=\"sm\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3642\" data-end=\"3660\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3661\" data-end=\"3685\"\u003e\n\u003ctd data-start=\"3661\" data-end=\"3674\" data-col-size=\"sm\"\u003eTDS Factor\u003c\/td\u003e\n\u003ctd data-start=\"3674\" data-end=\"3685\" data-col-size=\"md\"\u003e0.0–1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3686\" data-end=\"3715\"\u003e\n\u003ctd data-start=\"3686\" data-end=\"3703\" data-col-size=\"sm\"\u003eSalinity Range\u003c\/td\u003e\n\u003ctd data-start=\"3703\" data-end=\"3715\" data-col-size=\"md\"\u003e0–80 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3716\" data-end=\"3756\"\u003e\n\u003ctd data-start=\"3716\" data-end=\"3738\" data-col-size=\"sm\"\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3738\" data-end=\"3756\" data-col-size=\"md\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3757\" data-end=\"3795\"\u003e\n\u003ctd data-start=\"3757\" data-end=\"3777\" data-col-size=\"sm\"\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3777\" data-end=\"3795\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3796\" data-end=\"3891\"\u003e\n\u003ctd data-start=\"3796\" data-end=\"3824\" data-col-size=\"sm\"\u003eSalinity Measurement Mode\u003c\/td\u003e\n\u003ctd data-start=\"3824\" data-end=\"3891\" data-col-size=\"md\"\u003ePractical Salinity (PSU) or Seawater Measurement Standard (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3892\" data-end=\"3924\"\u003e\n\u003ctd data-start=\"3892\" data-end=\"3912\" data-col-size=\"sm\"\u003eResistivity Range\u003c\/td\u003e\n\u003ctd data-start=\"3912\" data-end=\"3924\" data-col-size=\"md\"\u003e0–100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3925\" data-end=\"3968\"\u003e\n\u003ctd data-start=\"3925\" data-end=\"3950\" data-col-size=\"sm\"\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3950\" data-end=\"3968\" data-col-size=\"md\"\u003e1 \/ 0.1 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3969\" data-end=\"4010\"\u003e\n\u003ctd data-start=\"3969\" data-end=\"3992\" data-col-size=\"sm\"\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3992\" data-end=\"4010\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4011\" data-end=\"4065\"\u003e\n\u003ctd data-start=\"4011\" data-end=\"4022\" data-col-size=\"sm\"\u003eDO Range\u003c\/td\u003e\n\u003ctd data-start=\"4022\" data-end=\"4065\" data-col-size=\"md\"\u003e0.00–20.00 mg\/L \/ 0.0–200.0% Saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4066\" data-end=\"4108\"\u003e\n\u003ctd data-start=\"4066\" data-end=\"4082\" data-col-size=\"sm\"\u003eDO Resolution\u003c\/td\u003e\n\u003ctd data-start=\"4082\" data-end=\"4108\" data-col-size=\"md\"\u003e0.01 \/ 0.1, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4109\" data-end=\"4144\"\u003e\n\u003ctd data-start=\"4109\" data-end=\"4123\" data-col-size=\"sm\"\u003eDO Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"4123\" data-end=\"4144\" data-col-size=\"md\"\u003e±0.2 mg\/L \/ ±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4145\" data-end=\"4179\"\u003e\n\u003ctd data-start=\"4145\" data-end=\"4162\" data-col-size=\"sm\"\u003eDO Calibration\u003c\/td\u003e\n\u003ctd data-start=\"4162\" data-end=\"4179\" data-col-size=\"md\"\u003e1 or 2 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4180\" data-end=\"4243\"\u003e\n\u003ctd data-start=\"4180\" data-end=\"4202\" data-col-size=\"sm\"\u003ePressure Correction\u003c\/td\u003e\n\u003ctd data-start=\"4202\" data-end=\"4243\" data-col-size=\"md\"\u003e60.0–112.5 kPa \/ 450–850 mmHg, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4244\" data-end=\"4286\"\u003e\n\u003ctd data-start=\"4244\" data-end=\"4264\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"4264\" data-end=\"4286\" data-col-size=\"md\"\u003e0–100°C \/ 32–212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4287\" data-end=\"4337\"\u003e\n\u003ctd data-start=\"4287\" data-end=\"4314\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4314\" data-end=\"4337\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4338\" data-end=\"4380\"\u003e\n\u003ctd data-start=\"4338\" data-end=\"4361\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"4361\" data-end=\"4380\" data-col-size=\"md\"\u003e±0.5°C \/ ±0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4381\" data-end=\"4399\"\u003e\n\u003ctd data-start=\"4381\" data-end=\"4392\" data-col-size=\"sm\"\u003eAuto-Off\u003c\/td\u003e\n\u003ctd data-start=\"4392\" data-end=\"4399\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4400\" data-end=\"4427\"\u003e\n\u003ctd data-start=\"4400\" data-end=\"4420\" data-col-size=\"sm\"\u003eReset \/ Auto-Hold\u003c\/td\u003e\n\u003ctd data-start=\"4420\" data-end=\"4427\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4428\" data-end=\"4467\"\u003e\n\u003ctd data-start=\"4428\" data-end=\"4450\" data-col-size=\"sm\"\u003eElectrode Diagnosis\u003c\/td\u003e\n\u003ctd data-start=\"4450\" data-end=\"4467\" data-col-size=\"md\"\u003eSlope, Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4468\" data-end=\"4518\"\u003e\n\u003ctd data-start=\"4468\" data-end=\"4491\" data-col-size=\"sm\"\u003eStability Conditions\u003c\/td\u003e\n\u003ctd data-start=\"4491\" data-end=\"4518\" data-col-size=\"md\"\u003eHigh or Low, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4519\" data-end=\"4571\"\u003e\n\u003ctd data-start=\"4519\" data-end=\"4546\" data-col-size=\"sm\"\u003eCalibration Due Reminder\u003c\/td\u003e\n\u003ctd data-start=\"4546\" data-end=\"4571\" data-col-size=\"md\"\u003e1–30 days, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4572\" data-end=\"4613\"\u003e\n\u003ctd data-start=\"4572\" data-end=\"4581\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"4581\" data-end=\"4613\" data-col-size=\"md\"\u003e500 data sets with Date\/Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4614\" data-end=\"4670\"\u003e\n\u003ctd data-start=\"4614\" data-end=\"4627\" data-col-size=\"sm\"\u003eConnectors\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4627\" data-end=\"4670\"\u003epH BNC; 6-pin connector; Conductivity R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4671\" data-end=\"4714\"\u003e\n\u003ctd data-start=\"4671\" data-end=\"4692\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"4692\" data-end=\"4714\" data-col-size=\"md\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4715\" data-end=\"4738\"\u003e\n\u003ctd data-start=\"4715\" data-end=\"4730\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"4730\" data-end=\"4738\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4739\" data-end=\"4762\"\u003e\n\u003ctd data-start=\"4739\" data-end=\"4750\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"4750\" data-end=\"4762\" data-col-size=\"md\"\u003e90275090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"4764\" data-end=\"4937\"\u003e*The brochure's specification table contains the calibration-solution values as printed; they have been retained without modification. \u003cspan class=\"contents\" data-content-reference-start=\"4893\" data-content-reference-end=\"4924\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"4939\" data-end=\"4956\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"4958\" data-end=\"5033\"\u003eThe LMMP32 is suitable for laboratory water-quality measurements involving:\u003c\/p\u003e\n\u003cul data-start=\"5035\" data-end=\"5255\"\u003e\n\u003cli data-section-id=\"vxg56i\" data-start=\"5035\" data-end=\"5051\"\u003epH measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1jj5gb3\" data-start=\"5052\" data-end=\"5069\"\u003eORP measurement\u003c\/li\u003e\n\u003cli data-section-id=\"bl77dt\" data-start=\"5070\" data-end=\"5097\"\u003eDissolved oxygen analysis\u003c\/li\u003e\n\u003cli data-section-id=\"flwpkt\" data-start=\"5098\" data-end=\"5124\"\u003eConductivity measurement\u003c\/li\u003e\n\u003cli data-section-id=\"t5nhs1\" data-start=\"5125\" data-end=\"5142\"\u003eTDS measurement\u003c\/li\u003e\n\u003cli data-section-id=\"12gyafz\" data-start=\"5143\" data-end=\"5165\"\u003eSalinity measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1ockker\" data-start=\"5166\" data-end=\"5191\"\u003eResistivity measurement\u003c\/li\u003e\n\u003cli data-section-id=\"z8lbht\" data-start=\"5192\" data-end=\"5229\"\u003eIon measurement using suitable ISEs\u003c\/li\u003e\n\u003cli data-section-id=\"27xnfy\" data-start=\"5230\" data-end=\"5255\"\u003eTemperature measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"5257\" data-end=\"5398\"\u003ePotential laboratory applications include routine water-quality testing, chemical analysis, research and educational laboratory measurements.\u003c\/p\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"5400\" data-end=\"5417\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cul data-start=\"5419\" data-end=\"5735\"\u003e\n\u003cli data-section-id=\"6czyvs\" data-start=\"5419\" data-end=\"5447\"\u003eWater-quality laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1iu5xdh\" data-start=\"5448\" data-end=\"5476\"\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"5477\" data-end=\"5500\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"5501\" data-end=\"5524\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"5525\" data-end=\"5554\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1q5aoag\" data-start=\"5555\" data-end=\"5591\"\u003eAcademic and teaching laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"15rdfsd\" data-start=\"5592\" data-end=\"5633\"\u003eIndustrial quality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"11u687v\" data-start=\"5634\" data-end=\"5689\"\u003eLaboratories performing multiparameter water analysis\u003c\/li\u003e\n\u003cli data-section-id=\"12gvppk\" data-start=\"5690\" data-end=\"5735\"\u003eLaboratories using ion-selective electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"8142\" data-end=\"8152\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"hzk6xe\" dir=\"auto\" data-start=\"8154\" data-end=\"8180\"\u003e1. What is the LMMP32?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8182\" data-end=\"8244\"\u003eThe LMMP32 is a \u003cstrong data-start=\"8198\" data-end=\"8243\"\u003e9-in-1 water quality multiparameter meter\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ra3lv6\" dir=\"auto\" data-start=\"8246\" data-end=\"8293\"\u003e2. Which parameters can the LMMP32 measure?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8295\" data-end=\"8392\"\u003eIt provides \u003cstrong data-start=\"8307\" data-end=\"8385\"\u003eIon, DO, Conductivity, pH, ORP, TDS, Salinity, Resistivity and Temperature\u003c\/strong\u003e modes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1i9pfls\" dir=\"auto\" data-start=\"8394\" data-end=\"8434\"\u003e3. What is the pH measurement range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8436\" data-end=\"8476\"\u003eThe pH range is \u003cstrong data-start=\"8452\" data-end=\"8475\"\u003e-2.000 to 20.000 pH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mtllpm\" dir=\"auto\" data-start=\"8478\" data-end=\"8530\"\u003e4. How many pH calibration points are available?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8532\" data-end=\"8619\"\u003eThe LMMP32 supports \u003cstrong data-start=\"8552\" data-end=\"8584\"\u003eup to 5-point pH calibration\u003c\/strong\u003e with automatic buffer recognition.\u003c\/p\u003e\n\u003ch3 data-section-id=\"gkf67k\" dir=\"auto\" data-start=\"8621\" data-end=\"8668\"\u003e5. What conductivity range does it measure?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8670\" data-end=\"8712\"\u003eThe conductivity range is \u003cstrong data-start=\"8696\" data-end=\"8711\"\u003e0–200 mS\/cm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xjl9kc\" dir=\"auto\" data-start=\"8714\" data-end=\"8756\"\u003e6. What is the dissolved oxygen range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8758\" data-end=\"8823\"\u003eThe DO range is \u003cstrong data-start=\"8774\" data-end=\"8793\"\u003e0.00–20.00 mg\/L\u003c\/strong\u003e or \u003cstrong data-start=\"8797\" data-end=\"8822\"\u003e0.0–200.0% saturation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"9sli9h\" dir=\"auto\" data-start=\"8825\" data-end=\"8854\"\u003e7. What is the TDS range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8856\" data-end=\"8955\"\u003eThe specified TDS range is \u003cstrong data-start=\"8883\" data-end=\"8895\"\u003e0–10 ppt\u003c\/strong\u003e, with a maximum of \u003cstrong data-start=\"8915\" data-end=\"8954\"\u003e200 ppt depending on factor setting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13yem1w\" dir=\"auto\" data-start=\"8957\" data-end=\"8991\"\u003e8. What is the salinity range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8993\" data-end=\"9028\"\u003eThe salinity range is \u003cstrong data-start=\"9015\" data-end=\"9027\"\u003e0–80 ppt\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"nunpoi\" dir=\"auto\" data-start=\"9030\" data-end=\"9076\"\u003e9. How much data can the instrument store?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9078\" data-end=\"9142\"\u003eThe LMMP32 can store \u003cstrong data-start=\"9099\" data-end=\"9141\"\u003eup to 500 data sets with date and time\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mt58ps\" dir=\"auto\" data-start=\"9144\" data-end=\"9203\"\u003e10. Does it provide automatic temperature compensation?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9205\" data-end=\"9308\"\u003eYes. ATC is available, and the instrument also allows \u003cstrong data-start=\"9259\" data-end=\"9307\"\u003eautomatic or manual temperature compensation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xf6ycc\" dir=\"auto\" data-start=\"9310\" data-end=\"9346\"\u003e11. Can the LMMP32 measure ions?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9348\" data-end=\"9462\"\u003eYes. The instrument has an \u003cstrong data-start=\"9375\" data-end=\"9387\"\u003eIon mode\u003c\/strong\u003e with a range of \u003cstrong data-start=\"9404\" data-end=\"9421\"\u003e0.00 to 19999\u003c\/strong\u003e, depending on the range of the ISE used.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cpa5cb\" dir=\"auto\" data-start=\"9464\" data-end=\"9511\"\u003e12. What optional electrodes are available?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9513\" data-end=\"9609\"\u003eThe brochure identifies \u003cstrong data-start=\"9537\" data-end=\"9584\"\u003eFluoride ISE, Nitrate ISE and ORP Electrode\u003c\/strong\u003e as optional accessories.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":50204291268905,"sku":"LMMP32","price":60399.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/WaterQualityMultiparameter.jpg?v=1777307593","url":"https:\/\/www.labmart.in\/products\/labmart-lmmp32-water-quality-multiparameter","provider":"Labmart.in","version":"1.0","type":"link"}