{"product_id":"labmart-lmmp30-water-quality-multiparameter-meter","title":"Multiparameter Water Quality Meter LMMP30","description":"\u003cp dir=\"auto\" data-start=\"173\" data-end=\"556\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"177\" data-end=\"230\"\u003eLabmart LMMP30 Water Quality Multiparameter Meter\u003c\/strong\u003e is a benchtop laboratory analyzer for simultaneous measurement of \u003cstrong data-start=\"297\" data-end=\"366\"\u003epH, ORP, conductivity, TDS, salinity, resistivity and temperature\u003c\/strong\u003e. It features multi-point calibration, automatic temperature compensation, automatic endpoint detection, electrode diagnosis, GLP-oriented data storage and memory for \u003cstrong data-start=\"533\" data-end=\"555\"\u003eup to 500 readings\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"593\" data-end=\"612\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"614\" data-end=\"786\"\u003eThe \u003cstrong data-start=\"618\" data-end=\"663\"\u003eLMMP30 Water Quality Multiparameter Meter\u003c\/strong\u003e is designed for comprehensive laboratory water-quality measurement. It combines seven measurement modes in one instrument:\u003c\/p\u003e\n\u003cul data-start=\"788\" data-end=\"858\"\u003e\n\u003cli data-section-id=\"yhmt8w\" data-start=\"788\" data-end=\"792\"\u003epH\u003c\/li\u003e\n\u003cli data-section-id=\"1o4aqt\" data-start=\"793\" data-end=\"798\"\u003eORP\u003c\/li\u003e\n\u003cli data-section-id=\"1ee4zrr\" data-start=\"799\" data-end=\"813\"\u003eConductivity\u003c\/li\u003e\n\u003cli data-section-id=\"1o4rxn\" data-start=\"814\" data-end=\"819\"\u003eTDS\u003c\/li\u003e\n\u003cli data-section-id=\"53y039\" data-start=\"820\" data-end=\"830\"\u003eSalinity\u003c\/li\u003e\n\u003cli data-section-id=\"ekn3zt\" data-start=\"831\" data-end=\"844\"\u003eResistivity\u003c\/li\u003e\n\u003cli data-section-id=\"1f3vflw\" data-start=\"845\" data-end=\"858\"\u003eTemperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"860\" data-end=\"1134\"\u003eThe meter provides dedicated calibration and measurement functions for each parameter. pH measurement supports up to \u003cstrong data-start=\"977\" data-end=\"1034\"\u003e5-point calibration with automatic buffer recognition\u003c\/strong\u003e, while conductivity also supports up to \u003cstrong data-start=\"1075\" data-end=\"1098\"\u003e5-point calibration\u003c\/strong\u003e with selectable standard solutions.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1136\" data-end=\"1472\"\u003eAutomatic Temperature Compensation (ATC), automatic endpoint detection, customizable stability conditions and electrode diagnosis help simplify routine measurement. The instrument can store \u003cstrong data-start=\"1326\" data-end=\"1368\"\u003eup to 500 data sets with date and time\u003c\/strong\u003e, with a built-in real-time clock for GLP-oriented record keeping. \u003cspan class=\"contents\" data-content-reference-start=\"1435\" data-content-reference-end=\"1465\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1474\" data-end=\"1500\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1502\" data-end=\"2375\"\u003e\n\u003cli data-section-id=\"9neusv\" data-start=\"1502\" data-end=\"1545\"\u003eSeven measurement modes in one instrument\u003c\/li\u003e\n\u003cli data-section-id=\"1vjanki\" data-start=\"1546\" data-end=\"1591\"\u003epH measurement from \u003cstrong data-start=\"1568\" data-end=\"1591\"\u003e-2.000 to 20.000 pH\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dzoknb\" data-start=\"1592\" data-end=\"1634\"\u003eORP measurement from \u003cstrong data-start=\"1615\" data-end=\"1634\"\u003e0 to ±1999.9 mV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d5w0pa\" data-start=\"1635\" data-end=\"1681\"\u003eConductivity measurement up to \u003cstrong data-start=\"1668\" data-end=\"1681\"\u003e200 mS\/cm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1c581ow\" data-start=\"1682\" data-end=\"1772\"\u003eTDS measurement up to \u003cstrong data-start=\"1706\" data-end=\"1716\"\u003e10 ppt\u003c\/strong\u003e, with maximum up to 200 ppt depending on factor setting\u003c\/li\u003e\n\u003cli data-section-id=\"hkjdi5\" data-start=\"1773\" data-end=\"1812\"\u003eSalinity measurement up to \u003cstrong data-start=\"1802\" data-end=\"1812\"\u003e80 ppt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14an1mg\" data-start=\"1813\" data-end=\"1855\"\u003eResistivity measurement up to \u003cstrong data-start=\"1845\" data-end=\"1855\"\u003e100 MΩ\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"voeqpd\" data-start=\"1856\" data-end=\"1901\"\u003eTemperature measurement from \u003cstrong data-start=\"1887\" data-end=\"1901\"\u003e0 to 100°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jm0d1s\" data-start=\"1902\" data-end=\"1936\"\u003eUp to \u003cstrong data-start=\"1910\" data-end=\"1936\"\u003e5-point pH calibration\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19shuwn\" data-start=\"1937\" data-end=\"1981\"\u003eUp to \u003cstrong data-start=\"1945\" data-end=\"1981\"\u003e5-point conductivity calibration\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17lvtm9\" data-start=\"1982\" data-end=\"2019\"\u003eAutomatic buffer recognition for pH\u003c\/li\u003e\n\u003cli data-section-id=\"ykpdpp\" data-start=\"2020\" data-end=\"2056\"\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli data-section-id=\"1k6wqgk\" data-start=\"2057\" data-end=\"2086\"\u003eAutomatic endpoint function\u003c\/li\u003e\n\u003cli data-section-id=\"d9vv7l\" data-start=\"2087\" data-end=\"2142\"\u003eElectrode diagnosis with slope and offset information\u003c\/li\u003e\n\u003cli data-section-id=\"174n6mt\" data-start=\"2143\" data-end=\"2169\"\u003eCalibration-due reminder\u003c\/li\u003e\n\u003cli data-section-id=\"gc1by2\" data-start=\"2170\" data-end=\"2203\"\u003eAdjustable stability conditions\u003c\/li\u003e\n\u003cli data-section-id=\"914nou\" data-start=\"2204\" data-end=\"2244\"\u003eUp to \u003cstrong data-start=\"2212\" data-end=\"2244\"\u003e500 data sets with date\/time\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bdhgrd\" data-start=\"2245\" data-end=\"2283\"\u003eSelectable °C \/ °F temperature units\u003c\/li\u003e\n\u003cli data-section-id=\"10tl87e\" data-start=\"2284\" data-end=\"2315\"\u003eReset and auto-hold functions\u003c\/li\u003e\n\u003cli data-section-id=\"zsi3hv\" data-start=\"2316\" data-end=\"2338\"\u003eUSB adaptor supplied\u003c\/li\u003e\n\u003cli data-section-id=\"znju7u\" data-start=\"2339\" data-end=\"2375\"\u003eDedicated electrode stand supplied\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2377\" data-end=\"2406\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2408\" data-end=\"4499\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2408\" data-end=\"2434\"\u003e\n\u003ctr data-start=\"2408\" data-end=\"2434\"\u003e\n\u003cth data-start=\"2408\" data-end=\"2424\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2424\" data-end=\"2434\" data-col-size=\"md\" class=\"last:pe-10\"\u003eLMMP30\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2445\" data-end=\"4499\"\u003e\n\u003ctr data-start=\"2445\" data-end=\"2498\"\u003e\n\u003ctd data-start=\"2445\" data-end=\"2460\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2460\" data-end=\"2498\" data-col-size=\"md\"\u003eWater Quality Multiparameter Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2499\" data-end=\"2517\"\u003e\n\u003ctd data-start=\"2499\" data-end=\"2507\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2507\" data-end=\"2517\" data-col-size=\"md\"\u003eLMMP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2518\" data-end=\"2537\"\u003e\n\u003ctd data-start=\"2518\" data-end=\"2526\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2526\" data-end=\"2537\" data-col-size=\"md\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2538\" data-end=\"2629\"\u003e\n\u003ctd data-start=\"2538\" data-end=\"2563\" data-col-size=\"sm\"\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd data-start=\"2563\" data-end=\"2629\" data-col-size=\"md\"\u003epH, ORP, Conductivity, TDS, Salinity, Resistivity, Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2630\" data-end=\"2668\"\u003e\n\u003ctd data-start=\"2630\" data-end=\"2645\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2632\" data-end=\"2644\"\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2645\" data-end=\"2668\" data-col-size=\"md\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2669\" data-end=\"2722\"\u003e\n\u003ctd data-start=\"2669\" data-end=\"2685\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2685\" data-end=\"2722\" data-col-size=\"md\"\u003e0.001 \/ 0.01 \/ 0.1 pH, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2723\" data-end=\"2750\"\u003e\n\u003ctd data-start=\"2723\" data-end=\"2737\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2737\" data-end=\"2750\" data-col-size=\"md\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2751\" data-end=\"2786\"\u003e\n\u003ctd data-start=\"2751\" data-end=\"2768\" data-col-size=\"sm\"\u003epH Calibration\u003c\/td\u003e\n\u003ctd data-start=\"2768\" data-end=\"2786\" data-col-size=\"md\"\u003eUp to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2787\" data-end=\"2827\"\u003e\n\u003ctd data-start=\"2787\" data-end=\"2809\" data-col-size=\"sm\"\u003epH Buffer Standards\u003c\/td\u003e\n\u003ctd data-start=\"2809\" data-end=\"2827\" data-col-size=\"md\"\u003eUSA, NIST, DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2828\" data-end=\"2863\"\u003e\n\u003ctd data-start=\"2828\" data-end=\"2844\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2830\" data-end=\"2843\"\u003eORP Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2844\" data-end=\"2863\" data-col-size=\"md\"\u003e0 to ±1999.9 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2864\" data-end=\"2893\"\u003e\n\u003ctd data-start=\"2864\" data-end=\"2882\" data-col-size=\"sm\"\u003eORP Calibration\u003c\/td\u003e\n\u003ctd data-start=\"2882\" data-end=\"2893\" data-col-size=\"md\"\u003e1-point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2894\" data-end=\"2937\"\u003e\n\u003ctd data-start=\"2894\" data-end=\"2911\" data-col-size=\"sm\"\u003eORP Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2911\" data-end=\"2937\" data-col-size=\"md\"\u003e0.1 \/ 1 mV, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2938\" data-end=\"2964\"\u003e\n\u003ctd data-start=\"2938\" data-end=\"2953\" data-col-size=\"sm\"\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2953\" data-end=\"2964\" data-col-size=\"md\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2965\" data-end=\"3013\"\u003e\n\u003ctd data-start=\"2965\" data-end=\"2983\" data-col-size=\"sm\"\u003eORP Measurement\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2983\" data-end=\"3013\"\u003eAbsolute mV or Relative mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3014\" data-end=\"3054\"\u003e\n\u003ctd data-start=\"3014\" data-end=\"3039\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3016\" data-end=\"3038\"\u003eConductivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3039\" data-end=\"3054\" data-col-size=\"md\"\u003e0–200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3055\" data-end=\"3099\"\u003e\n\u003ctd data-start=\"3055\" data-end=\"3081\" data-col-size=\"sm\"\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3081\" data-end=\"3099\" data-col-size=\"md\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3100\" data-end=\"3144\"\u003e\n\u003ctd data-start=\"3100\" data-end=\"3124\" data-col-size=\"sm\"\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3124\" data-end=\"3144\" data-col-size=\"md\"\u003e±0.5% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3145\" data-end=\"3191\"\u003e\n\u003ctd data-start=\"3145\" data-end=\"3161\" data-col-size=\"sm\"\u003eCell Constant\u003c\/td\u003e\n\u003ctd data-start=\"3161\" data-end=\"3191\" data-col-size=\"md\"\u003e0.0 \/ 1 \/ 10, user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3192\" data-end=\"3238\"\u003e\n\u003ctd data-start=\"3192\" data-end=\"3218\" data-col-size=\"sm\"\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd data-start=\"3218\" data-end=\"3238\" data-col-size=\"md\"\u003e0.0–10.0% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3239\" data-end=\"3284\"\u003e\n\u003ctd data-start=\"3239\" data-end=\"3266\" data-col-size=\"sm\"\u003eConductivity Calibration\u003c\/td\u003e\n\u003ctd data-start=\"3266\" data-end=\"3284\" data-col-size=\"md\"\u003eUp to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3285\" data-end=\"3370\"\u003e\n\u003ctd data-start=\"3285\" data-end=\"3310\" data-col-size=\"sm\"\u003eConductivity Standards\u003c\/td\u003e\n\u003ctd data-start=\"3310\" data-end=\"3370\" data-col-size=\"md\"\u003e10 µS\/cm, 84 µS\/cm, 1413 µS\/cm, 12.88 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3371\" data-end=\"3416\"\u003e\n\u003ctd data-start=\"3371\" data-end=\"3392\" data-col-size=\"sm\"\u003eCompensation Modes\u003c\/td\u003e\n\u003ctd data-start=\"3392\" data-end=\"3416\" data-col-size=\"md\"\u003eLinear or Pure Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3417\" data-end=\"3487\"\u003e\n\u003ctd data-start=\"3417\" data-end=\"3433\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3419\" data-end=\"3432\"\u003eTDS Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3433\" data-end=\"3487\" data-col-size=\"md\"\u003e0–10 ppt; max. 200 ppt depending on factor setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3488\" data-end=\"3523\"\u003e\n\u003ctd data-start=\"3488\" data-end=\"3505\" data-col-size=\"sm\"\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3505\" data-end=\"3523\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3524\" data-end=\"3557\"\u003e\n\u003ctd data-start=\"3524\" data-end=\"3539\" data-col-size=\"sm\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3539\" data-end=\"3557\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3558\" data-end=\"3582\"\u003e\n\u003ctd data-start=\"3558\" data-end=\"3571\" data-col-size=\"sm\"\u003eTDS Factor\u003c\/td\u003e\n\u003ctd data-start=\"3571\" data-end=\"3582\" data-col-size=\"md\"\u003e0.0–1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3583\" data-end=\"3616\"\u003e\n\u003ctd data-start=\"3583\" data-end=\"3604\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3585\" data-end=\"3603\"\u003eSalinity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3604\" data-end=\"3616\"\u003e0–80 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3617\" data-end=\"3657\"\u003e\n\u003ctd data-start=\"3617\" data-end=\"3639\" data-col-size=\"sm\"\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3639\" data-end=\"3657\" data-col-size=\"md\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3658\" data-end=\"3696\"\u003e\n\u003ctd data-start=\"3658\" data-end=\"3678\" data-col-size=\"sm\"\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3678\" data-end=\"3696\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3697\" data-end=\"3787\"\u003e\n\u003ctd data-start=\"3697\" data-end=\"3720\" data-col-size=\"sm\"\u003eSalinity Measurement\u003c\/td\u003e\n\u003ctd data-start=\"3720\" data-end=\"3787\" data-col-size=\"md\"\u003ePractical Salinity (PSU) or Seawater Measurement Standard (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3788\" data-end=\"3824\"\u003e\n\u003ctd data-start=\"3788\" data-end=\"3812\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3790\" data-end=\"3811\"\u003eResistivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3812\" data-end=\"3824\" data-col-size=\"md\"\u003e0–100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3825\" data-end=\"3868\"\u003e\n\u003ctd data-start=\"3825\" data-end=\"3850\" data-col-size=\"sm\"\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3850\" data-end=\"3868\" data-col-size=\"md\"\u003e1 \/ 0.1 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3869\" data-end=\"3910\"\u003e\n\u003ctd data-start=\"3869\" data-end=\"3892\" data-col-size=\"sm\"\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3892\" data-end=\"3910\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3911\" data-end=\"3946\"\u003e\n\u003ctd data-start=\"3911\" data-end=\"3935\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3913\" data-end=\"3934\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3935\" data-end=\"3946\" data-col-size=\"md\"\u003e0–100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3947\" data-end=\"3997\"\u003e\n\u003ctd data-start=\"3947\" data-end=\"3974\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"3974\" data-end=\"3997\" data-col-size=\"md\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3998\" data-end=\"4031\"\u003e\n\u003ctd data-start=\"3998\" data-end=\"4021\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"4021\" data-end=\"4031\" data-col-size=\"md\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4032\" data-end=\"4063\"\u003e\n\u003ctd data-start=\"4032\" data-end=\"4052\" data-col-size=\"sm\"\u003eTemperature Units\u003c\/td\u003e\n\u003ctd data-start=\"4052\" data-end=\"4063\" data-col-size=\"md\"\u003e°C \/ °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4064\" data-end=\"4120\"\u003e\n\u003ctd data-start=\"4064\" data-end=\"4075\" data-col-size=\"sm\"\u003eAuto-Off\u003c\/td\u003e\n\u003ctd data-start=\"4075\" data-end=\"4120\" data-col-size=\"md\"\u003e10 \/ 20 \/ 30 minutes after last key press\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4121\" data-end=\"4148\"\u003e\n\u003ctd data-start=\"4121\" data-end=\"4141\" data-col-size=\"sm\"\u003eReset \u0026amp; Auto Hold\u003c\/td\u003e\n\u003ctd data-start=\"4141\" data-end=\"4148\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4149\" data-end=\"4188\"\u003e\n\u003ctd data-start=\"4149\" data-end=\"4171\" data-col-size=\"sm\"\u003eElectrode Diagnosis\u003c\/td\u003e\n\u003ctd data-start=\"4171\" data-end=\"4188\" data-col-size=\"md\"\u003eSlope, Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4189\" data-end=\"4239\"\u003e\n\u003ctd data-start=\"4189\" data-end=\"4212\" data-col-size=\"sm\"\u003eStability Conditions\u003c\/td\u003e\n\u003ctd data-start=\"4212\" data-end=\"4239\" data-col-size=\"md\"\u003eHigh or Low, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4240\" data-end=\"4288\"\u003e\n\u003ctd data-start=\"4240\" data-end=\"4263\" data-col-size=\"sm\"\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4263\" data-end=\"4288\"\u003e1–30 days, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4289\" data-end=\"4330\"\u003e\n\u003ctd data-start=\"4289\" data-end=\"4298\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"4298\" data-end=\"4330\" data-col-size=\"md\"\u003e500 data sets with date\/time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4331\" data-end=\"4369\"\u003e\n\u003ctd data-start=\"4331\" data-end=\"4346\" data-col-size=\"sm\"\u003epH Connector\u003c\/td\u003e\n\u003ctd data-start=\"4346\" data-end=\"4369\" data-col-size=\"md\"\u003eBNC 6-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4370\" data-end=\"4421\"\u003e\n\u003ctd data-start=\"4370\" data-end=\"4395\" data-col-size=\"sm\"\u003eConductivity Connector\u003c\/td\u003e\n\u003ctd data-start=\"4395\" data-end=\"4421\" data-col-size=\"md\"\u003eConductivity connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4422\" data-end=\"4457\"\u003e\n\u003ctd data-start=\"4422\" data-end=\"4435\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"4435\" data-end=\"4457\" data-col-size=\"md\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4458\" data-end=\"4475\"\u003e\n\u003ctd data-start=\"4458\" data-end=\"4467\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"4467\" data-end=\"4475\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4476\" data-end=\"4499\"\u003e\n\u003ctd data-start=\"4476\" data-end=\"4487\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4487\" data-end=\"4499\"\u003e90275090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"4501\" data-end=\"4620\"\u003eThe model-specific specifications are provided in the LMMP30 specification table. \u003cspan class=\"contents\" data-content-reference-start=\"4576\" data-content-reference-end=\"4607\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"4622\" data-end=\"4639\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"4641\" data-end=\"4668\"\u003eThe LMMP30 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"4670\" data-end=\"5036\"\u003e\n\u003cli data-section-id=\"5i1wpu\" data-start=\"4670\" data-end=\"4694\"\u003eWater quality analysis\u003c\/li\u003e\n\u003cli data-section-id=\"e7atm0\" data-start=\"4695\" data-end=\"4721\"\u003eLaboratory water testing\u003c\/li\u003e\n\u003cli data-section-id=\"1r4pg64\" data-start=\"4722\" data-end=\"4746\"\u003eDrinking-water testing\u003c\/li\u003e\n\u003cli data-section-id=\"170v917\" data-start=\"4747\" data-end=\"4768\"\u003eWastewater analysis\u003c\/li\u003e\n\u003cli data-section-id=\"ebqs9x\" data-start=\"4769\" data-end=\"4803\"\u003eEnvironmental laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"4804\" data-end=\"4827\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1rh3zyj\" data-start=\"4828\" data-end=\"4870\"\u003ePharmaceutical laboratory water analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"4871\" data-end=\"4903\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"4904\" data-end=\"4927\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1q5aoag\" data-start=\"4928\" data-end=\"4964\"\u003eAcademic and teaching laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"16gk1fa\" data-start=\"4965\" data-end=\"5002\"\u003eIndustrial water-quality monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"18vt26m\" data-start=\"5003\" data-end=\"5036\"\u003eGeneral aqueous-sample analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"5038\" data-end=\"5055\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"5057\" data-end=\"5084\"\u003eThe LMMP30 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"5086\" data-end=\"5356\"\u003e\n\u003cli data-section-id=\"1iu5xdh\" data-start=\"5086\" data-end=\"5114\"\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1fs6tb7\" data-start=\"5115\" data-end=\"5143\"\u003eWater-testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"5144\" data-end=\"5173\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"5174\" data-end=\"5206\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"5207\" data-end=\"5230\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1t31nfa\" data-start=\"5231\" data-end=\"5254\"\u003eResearch institutions\u003c\/li\u003e\n\u003cli data-section-id=\"167fuah\" data-start=\"5255\" data-end=\"5282\"\u003eUniversities and colleges\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"5283\" data-end=\"5313\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10vtoei\" data-start=\"5314\" data-end=\"5339\"\u003eIndustrial laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"fislkr\" data-start=\"5340\" data-end=\"5356\"\u003eR\u0026amp;D facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"7800\" data-end=\"7810\" class=\"PDq2pG_selectionAnchorContainer\"\u003e10. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1tym7dw\" dir=\"auto\" data-start=\"7812\" data-end=\"7858\"\u003e1. What parameters can the LMMP30 measure?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7860\" data-end=\"7950\"\u003eThe LMMP30 measures \u003cstrong data-start=\"7880\" data-end=\"7949\"\u003epH, ORP, conductivity, TDS, salinity, resistivity and temperature\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxtlr5\" dir=\"auto\" data-start=\"7952\" data-end=\"7992\"\u003e2. What is the pH measurement range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7994\" data-end=\"8034\"\u003eThe pH range is \u003cstrong data-start=\"8010\" data-end=\"8033\"\u003e-2.000 to 20.000 pH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1gwmh71\" dir=\"auto\" data-start=\"8036\" data-end=\"8088\"\u003e3. How many pH calibration points are available?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8090\" data-end=\"8181\"\u003eThe instrument supports \u003cstrong data-start=\"8114\" data-end=\"8146\"\u003eup to 5-point pH calibration\u003c\/strong\u003e with automatic buffer recognition.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xtxibr\" dir=\"auto\" data-start=\"8183\" data-end=\"8228\"\u003e4. What ORP range does the meter provide?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8230\" data-end=\"8267\"\u003eThe ORP range is \u003cstrong data-start=\"8247\" data-end=\"8266\"\u003e0 to ±1999.9 mV\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"javfjf\" dir=\"auto\" data-start=\"8269\" data-end=\"8307\"\u003e5. What is the conductivity range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8309\" data-end=\"8351\"\u003eThe conductivity range is \u003cstrong data-start=\"8335\" data-end=\"8350\"\u003e0–200 mS\/cm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"3zwb90\" dir=\"auto\" data-start=\"8353\" data-end=\"8382\"\u003e6. What is the TDS range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8384\" data-end=\"8496\"\u003eThe specified TDS range is \u003cstrong data-start=\"8411\" data-end=\"8423\"\u003e0–10 ppt\u003c\/strong\u003e, with a maximum of \u003cstrong data-start=\"8443\" data-end=\"8495\"\u003e200 ppt depending on the selected factor setting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1e05le3\" dir=\"auto\" data-start=\"8498\" data-end=\"8532\"\u003e7. What is the salinity range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8534\" data-end=\"8569\"\u003eThe salinity range is \u003cstrong data-start=\"8556\" data-end=\"8568\"\u003e0–80 ppt\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vgfklk\" dir=\"auto\" data-start=\"8571\" data-end=\"8608\"\u003e8. What is the resistivity range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8610\" data-end=\"8648\"\u003eThe resistivity range is \u003cstrong data-start=\"8635\" data-end=\"8647\"\u003e0–100 MΩ\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"9iq3yi\" dir=\"auto\" data-start=\"8650\" data-end=\"8713\"\u003e9. Does the LMMP30 have automatic temperature compensation?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8715\" data-end=\"8884\"\u003eYes. The instrument provides \u003cstrong data-start=\"8744\" data-end=\"8788\"\u003eAutomatic Temperature Compensation (ATC)\u003c\/strong\u003e and also allows automatic or manual temperature compensation depending on the measurement mode.\u003c\/p\u003e\n\u003ch3 data-section-id=\"23yauc\" dir=\"auto\" data-start=\"8886\" data-end=\"8928\"\u003e10. How much data can the meter store?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8930\" data-end=\"9032\"\u003eThe LMMP30 can store \u003cstrong data-start=\"8951\" data-end=\"8993\"\u003eup to 500 data sets with date and time\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"8975\" data-content-reference-end=\"9005\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ji77jl\" dir=\"auto\" data-start=\"9034\" data-end=\"9090\"\u003e11. Does the instrument provide electrode diagnosis?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9092\" data-end=\"9172\"\u003eYes. The electrode diagnosis function provides \u003cstrong data-start=\"9139\" data-end=\"9159\"\u003eslope and offset\u003c\/strong\u003e information.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13myqh8\" dir=\"auto\" data-start=\"9174\" data-end=\"9212\"\u003e12. What accessories are supplied?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"9214\" data-end=\"9461\"\u003eThe standard accessories include the \u003cstrong data-start=\"9251\" data-end=\"9422\"\u003emain instrument, pH electrode, pH buffers, 1K conductivity cell, calibration solution, electrode stand, ATC probe, USB adaptor, instruction manual and test certificate\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49269412593961,"sku":"LMMP30","price":44799.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/lmmp-30.png?v=1777307716","url":"https:\/\/www.labmart.in\/products\/labmart-lmmp30-water-quality-multiparameter-meter","provider":"Labmart.in","version":"1.0","type":"link"}