{"product_id":"labmart-lmdo50-dissolved-oxygen-meter","title":"Dissolved Oxygen Meter LMDO50","description":"\u003cp dir=\"auto\" data-start=\"153\" data-end=\"573\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"157\" data-end=\"208\"\u003eLabmart LMDO50 Bench Top Dissolved Oxygen Meter\u003c\/strong\u003e is a professional laboratory instrument for measuring dissolved oxygen concentration and oxygen saturation in water. It features a \u003cstrong data-start=\"340\" data-end=\"572\"\u003epolarographic DO sensor, 0.00–20.00 mg\/L or ppm range, 0–200% oxygen saturation, automatic temperature compensation, salinity and barometric-pressure correction, 1- or 2-point calibration, USB connectivity and 500-reading memory\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"575\" data-end=\"608\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"610\" data-end=\"629\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"631\" data-end=\"812\"\u003eThe \u003cstrong data-start=\"635\" data-end=\"668\"\u003eLMDO50 Dissolved Oxygen Meter\u003c\/strong\u003e is a professional benchtop instrument designed for laboratory measurement of \u003cstrong data-start=\"746\" data-end=\"811\"\u003edissolved oxygen concentration and oxygen saturation in water\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"814\" data-end=\"1111\"\u003eThe instrument uses a \u003cstrong data-start=\"836\" data-end=\"877\"\u003epolarographic dissolved oxygen sensor\u003c\/strong\u003e and provides selectable readout in \u003cstrong data-start=\"913\" data-end=\"942\"\u003eppm, mg\/L or % saturation\u003c\/strong\u003e. Automatic temperature compensation helps maintain measurement accuracy, while manual entry of salinity and barometric pressure enables correction for these parameters.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1113\" data-end=\"1348\"\u003eThe LMDO50 supports \u003cstrong data-start=\"1133\" data-end=\"1162\"\u003e1- or 2-point calibration\u003c\/strong\u003e, including calibration at 100% in saturated air or air-saturated water and 0% in a zero-oxygen solution. An automatic endpoint function freezes stable readings for convenient recording.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1350\" data-end=\"1530\"\u003eThe meter also provides \u003cstrong data-start=\"1374\" data-end=\"1412\"\u003e500-data memory with date and time\u003c\/strong\u003e, a real-time clock for stored data, calibration reminders, user-configurable stability settings and USB connectivity.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1532\" data-end=\"1558\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1560\" data-end=\"2306\"\u003e\n\u003cli data-section-id=\"isdqfu\" data-start=\"1560\" data-end=\"1611\"\u003eProfessional \u003cstrong data-start=\"1575\" data-end=\"1611\"\u003ebench top dissolved oxygen meter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gtef8s\" data-start=\"1612\" data-end=\"1651\"\u003ePolarographic dissolved oxygen sensor\u003c\/li\u003e\n\u003cli data-section-id=\"1mfjh72\" data-start=\"1652\" data-end=\"1701\"\u003eDO measurement range \u003cstrong data-start=\"1675\" data-end=\"1701\"\u003e0.00–20.00 mg\/L or ppm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19v2kzh\" data-start=\"1702\" data-end=\"1742\"\u003eOxygen saturation range \u003cstrong data-start=\"1728\" data-end=\"1742\"\u003e0.0–200.0%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"r7xgfg\" data-start=\"1743\" data-end=\"1790\"\u003eSelectable ppm, mg\/L and % saturation readout\u003c\/li\u003e\n\u003cli data-section-id=\"uv5oh9\" data-start=\"1791\" data-end=\"1832\"\u003e\u003cstrong data-start=\"1793\" data-end=\"1832\"\u003e1- or 2-point automatic calibration\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"7gdkz1\" data-start=\"1833\" data-end=\"1869\"\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cli data-section-id=\"196pz9d\" data-start=\"1870\" data-end=\"1904\"\u003eSalinity correction \u003cstrong data-start=\"1892\" data-end=\"1904\"\u003e0–50 g\/L\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bl1jfd\" data-start=\"1905\" data-end=\"1956\"\u003eBarometric pressure correction \u003cstrong data-start=\"1938\" data-end=\"1956\"\u003e60.0–112.5 kPa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1k6wqgk\" data-start=\"1957\" data-end=\"1986\"\u003eAutomatic endpoint function\u003c\/li\u003e\n\u003cli data-section-id=\"174n6mt\" data-start=\"1987\" data-end=\"2013\"\u003eCalibration-due reminder\u003c\/li\u003e\n\u003cli data-section-id=\"1k5f9kg\" data-start=\"2014\" data-end=\"2034\"\u003eUser help messages\u003c\/li\u003e\n\u003cli data-section-id=\"fgk8b4\" data-start=\"2035\" data-end=\"2080\"\u003eAdjustable measurement stability conditions\u003c\/li\u003e\n\u003cli data-section-id=\"14o01xl\" data-start=\"2081\" data-end=\"2121\"\u003e\u003cstrong data-start=\"2083\" data-end=\"2121\"\u003e500-data memory with date and time\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"uefnfy\" data-start=\"2122\" data-end=\"2148\"\u003eBuilt-in real-time clock\u003c\/li\u003e\n\u003cli data-section-id=\"9p0sex\" data-start=\"2149\" data-end=\"2162\"\u003eLCD display\u003c\/li\u003e\n\u003cli data-section-id=\"1qwluud\" data-start=\"2163\" data-end=\"2178\"\u003eHold function\u003c\/li\u003e\n\u003cli data-section-id=\"9xuscp\" data-start=\"2179\" data-end=\"2194\"\u003eUSB interface\u003c\/li\u003e\n\u003cli data-section-id=\"1mfphco\" data-start=\"2195\" data-end=\"2225\"\u003eLow\/High stability selection\u003c\/li\u003e\n\u003cli data-section-id=\"1s8plun\" data-start=\"2226\" data-end=\"2306\"\u003eSupplied with DO probe, membrane cap, electrolyte solution and electrode stand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2308\" data-end=\"2337\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2339\" data-end=\"3421\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2339\" data-end=\"2365\"\u003e\n\u003ctr data-start=\"2339\" data-end=\"2365\"\u003e\n\u003cth data-start=\"2339\" data-end=\"2355\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2355\" data-end=\"2365\" data-col-size=\"md\" class=\"last:pe-10\"\u003eLMDO50\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2376\" data-end=\"3421\"\u003e\n\u003ctr data-start=\"2376\" data-end=\"2427\"\u003e\n\u003ctd data-start=\"2376\" data-end=\"2391\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2391\" data-end=\"2427\" data-col-size=\"md\"\u003eBench Top Dissolved Oxygen Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2428\" data-end=\"2446\"\u003e\n\u003ctd data-start=\"2428\" data-end=\"2436\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2436\" data-end=\"2446\" data-col-size=\"md\"\u003eLMDO50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2447\" data-end=\"2466\"\u003e\n\u003ctd data-start=\"2447\" data-end=\"2455\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2455\" data-end=\"2466\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2467\" data-end=\"2508\"\u003e\n\u003ctd data-start=\"2467\" data-end=\"2481\" data-col-size=\"sm\"\u003eSensor Type\u003c\/td\u003e\n\u003ctd data-start=\"2481\" data-end=\"2508\" data-col-size=\"md\"\u003ePolarographic DO Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2509\" data-end=\"2560\"\u003e\n\u003ctd data-start=\"2509\" data-end=\"2534\" data-col-size=\"sm\"\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2534\" data-end=\"2560\"\u003e0.00–20.00 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2561\" data-end=\"2607\"\u003e\n\u003ctd data-start=\"2561\" data-end=\"2577\" data-col-size=\"sm\"\u003eDO Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2577\" data-end=\"2607\"\u003e0.1 \/ 0.01 ppm, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2608\" data-end=\"2642\"\u003e\n\u003ctd data-start=\"2608\" data-end=\"2622\" data-col-size=\"sm\"\u003eDO Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2622\" data-end=\"2642\" data-col-size=\"md\"\u003e±0.2 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2643\" data-end=\"2683\"\u003e\n\u003ctd data-start=\"2643\" data-end=\"2669\" data-col-size=\"sm\"\u003eOxygen Saturation Range\u003c\/td\u003e\n\u003ctd data-start=\"2669\" data-end=\"2683\" data-col-size=\"md\"\u003e0.0–200.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2684\" data-end=\"2732\"\u003e\n\u003ctd data-start=\"2684\" data-end=\"2708\" data-col-size=\"sm\"\u003eSaturation Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2708\" data-end=\"2732\"\u003e0.1 \/ 1%, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2733\" data-end=\"2764\"\u003e\n\u003ctd data-start=\"2733\" data-end=\"2755\" data-col-size=\"sm\"\u003eSaturation Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2755\" data-end=\"2764\"\u003e±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2765\" data-end=\"2799\"\u003e\n\u003ctd data-start=\"2765\" data-end=\"2785\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2785\" data-end=\"2799\"\u003e0.0–50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2800\" data-end=\"2833\"\u003e\n\u003ctd data-start=\"2800\" data-end=\"2823\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2823\" data-end=\"2833\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2834\" data-end=\"2882\"\u003e\n\u003ctd data-start=\"2834\" data-end=\"2861\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2861\" data-end=\"2882\"\u003eAutomatic, 0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2883\" data-end=\"2917\"\u003e\n\u003ctd data-start=\"2883\" data-end=\"2905\" data-col-size=\"sm\"\u003eSalinity Correction\u003c\/td\u003e\n\u003ctd data-start=\"2905\" data-end=\"2917\" data-col-size=\"md\"\u003e0–50 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2918\" data-end=\"2984\"\u003e\n\u003ctd data-start=\"2918\" data-end=\"2951\" data-col-size=\"sm\"\u003eBarometric Pressure Correction\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2951\" data-end=\"2984\"\u003e60.0–112.5 kPa \/ 450–850 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2985\" data-end=\"3016\"\u003e\n\u003ctd data-start=\"2985\" data-end=\"2999\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2999\" data-end=\"3016\"\u003e1 or 2 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3017\" data-end=\"3101\"\u003e\n\u003ctd data-start=\"3017\" data-end=\"3038\" data-col-size=\"sm\"\u003eCalibration Points\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3038\" data-end=\"3101\"\u003e100% in air\/air-saturated water; 0% in zero-oxygen solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3102\" data-end=\"3145\"\u003e\n\u003ctd data-start=\"3102\" data-end=\"3111\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3111\" data-end=\"3145\" data-col-size=\"md\"\u003e500 data sets with date \u0026amp; time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3146\" data-end=\"3163\"\u003e\n\u003ctd data-start=\"3146\" data-end=\"3156\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3156\" data-end=\"3163\" data-col-size=\"md\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3164\" data-end=\"3193\"\u003e\n\u003ctd data-start=\"3164\" data-end=\"3180\" data-col-size=\"sm\"\u003eHold Function\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3180\" data-end=\"3193\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3194\" data-end=\"3230\"\u003e\n\u003ctd data-start=\"3194\" data-end=\"3216\" data-col-size=\"sm\"\u003eStability Selection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3216\" data-end=\"3230\"\u003eLow \/ High\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3231\" data-end=\"3250\"\u003e\n\u003ctd data-start=\"3231\" data-end=\"3243\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3243\" data-end=\"3250\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3251\" data-end=\"3281\"\u003e\n\u003ctd data-start=\"3251\" data-end=\"3263\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3263\" data-end=\"3281\"\u003e6-pin Mini-DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3282\" data-end=\"3329\"\u003e\n\u003ctd data-start=\"3282\" data-end=\"3297\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3297\" data-end=\"3329\"\u003eDC Adapter, AC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3330\" data-end=\"3373\"\u003e\n\u003ctd data-start=\"3330\" data-end=\"3351\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3351\" data-end=\"3373\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3374\" data-end=\"3397\"\u003e\n\u003ctd data-start=\"3374\" data-end=\"3389\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3389\" data-end=\"3397\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3398\" data-end=\"3421\"\u003e\n\u003ctd data-start=\"3398\" data-end=\"3409\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"3409\" data-end=\"3421\" data-col-size=\"md\"\u003e90275090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3423\" data-end=\"3440\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3442\" data-end=\"3501\"\u003eThe LMDO50 is suitable for dissolved oxygen measurement in:\u003c\/p\u003e\n\u003cul data-start=\"3503\" data-end=\"3777\"\u003e\n\u003cli data-section-id=\"12ualtb\" data-start=\"3503\" data-end=\"3527\"\u003eWater-quality analysis\u003c\/li\u003e\n\u003cli data-section-id=\"z6v1hv\" data-start=\"3528\" data-end=\"3557\"\u003eEnvironmental water testing\u003c\/li\u003e\n\u003cli data-section-id=\"169mrkp\" data-start=\"3558\" data-end=\"3580\"\u003eAquaculture research\u003c\/li\u003e\n\u003cli data-section-id=\"1mnoogc\" data-start=\"3581\" data-end=\"3606\"\u003eWastewater laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3607\" data-end=\"3630\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"129jawa\" data-start=\"3631\" data-end=\"3656\"\u003eBiological laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"kh6azt\" data-start=\"3657\" data-end=\"3683\"\u003eResearch and development\u003c\/li\u003e\n\u003cli data-section-id=\"n3djqi\" data-start=\"3684\" data-end=\"3710\"\u003eEducational laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3711\" data-end=\"3741\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"95ehei\" data-start=\"3742\" data-end=\"3777\"\u003eGeneral laboratory water analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3779\" data-end=\"3796\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3798\" data-end=\"3825\"\u003eThe LMDO50 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3827\" data-end=\"4133\"\u003e\n\u003cli data-section-id=\"1iu5xdh\" data-start=\"3827\" data-end=\"3855\"\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1fs6tb7\" data-start=\"3856\" data-end=\"3884\"\u003eWater-testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"hiegzp\" data-start=\"3885\" data-end=\"3911\"\u003eAquaculture laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1t31nfa\" data-start=\"3912\" data-end=\"3935\"\u003eResearch institutions\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3936\" data-end=\"3959\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"129jawa\" data-start=\"3960\" data-end=\"3985\"\u003eBiological laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"167fuah\" data-start=\"3986\" data-end=\"4013\"\u003eUniversities and colleges\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"4014\" data-end=\"4044\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10vtoei\" data-start=\"4045\" data-end=\"4070\"\u003eIndustrial laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"15fddvh\" data-start=\"4071\" data-end=\"4133\"\u003eLaboratories requiring benchtop dissolved oxygen measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"6542\" data-end=\"6552\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1at0fks\" dir=\"auto\" data-start=\"6554\" data-end=\"6589\"\u003e1. What is the LMDO50 used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6591\" data-end=\"6687\"\u003eThe LMDO50 is used to measure \u003cstrong data-start=\"6621\" data-end=\"6686\"\u003edissolved oxygen concentration and oxygen saturation in water\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"gp5v42\" dir=\"auto\" data-start=\"6689\" data-end=\"6743\"\u003e2. What is the dissolved oxygen measurement range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6745\" data-end=\"6785\"\u003eThe range is \u003cstrong data-start=\"6758\" data-end=\"6784\"\u003e0.00–20.00 mg\/L or ppm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mc2s4a\" dir=\"auto\" data-start=\"6787\" data-end=\"6835\"\u003e3. Can the LMDO50 display oxygen saturation?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6837\" data-end=\"6897\"\u003eYes. Oxygen saturation can be displayed from \u003cstrong data-start=\"6882\" data-end=\"6896\"\u003e0.0–200.0%\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"o7mhss\" dir=\"auto\" data-start=\"6899\" data-end=\"6930\"\u003e4. What is the DO accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6932\" data-end=\"6996\"\u003eThe specified dissolved oxygen accuracy is \u003cstrong data-start=\"6975\" data-end=\"6995\"\u003e±0.2 mg\/L or ppm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5xybnr\" dir=\"auto\" data-start=\"6998\" data-end=\"7048\"\u003e5. Does the LMDO50 compensate for temperature?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7050\" data-end=\"7118\"\u003eYes. It provides \u003cstrong data-start=\"7067\" data-end=\"7117\"\u003eautomatic temperature compensation from 0–50°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"u3ruco\" dir=\"auto\" data-start=\"7120\" data-end=\"7153\"\u003e6. Can salinity be corrected?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7155\" data-end=\"7211\"\u003eYes. Salinity correction is available from \u003cstrong data-start=\"7198\" data-end=\"7210\"\u003e0–50 g\/L\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"bsctrm\" dir=\"auto\" data-start=\"7213\" data-end=\"7270\"\u003e7. Does the meter compensate for barometric pressure?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7272\" data-end=\"7361\"\u003eYes. Barometric-pressure correction is available from \u003cstrong data-start=\"7326\" data-end=\"7360\"\u003e60.0–112.5 kPa or 450–850 mmHg\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"114iw66\" dir=\"auto\" data-start=\"7363\" data-end=\"7412\"\u003e8. How many calibration points are available?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7414\" data-end=\"7464\"\u003eThe LMDO50 supports \u003cstrong data-start=\"7434\" data-end=\"7463\"\u003e1- or 2-point calibration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"nunpoi\" dir=\"auto\" data-start=\"7466\" data-end=\"7512\"\u003e9. How much data can the instrument store?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7514\" data-end=\"7577\"\u003eThe meter can store up to \u003cstrong data-start=\"7540\" data-end=\"7576\"\u003e500 data sets with date and time\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"147h4cr\" dir=\"auto\" data-start=\"7579\" data-end=\"7624\"\u003e10. Does the LMDO50 have a hold function?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7626\" data-end=\"7699\"\u003eYes. A \u003cstrong data-start=\"7633\" data-end=\"7650\"\u003ehold function\u003c\/strong\u003e is provided for retaining the displayed reading.\u003c\/p\u003e\n\u003ch3 data-section-id=\"imaskd\" dir=\"auto\" data-start=\"7701\" data-end=\"7751\"\u003e11. Does the instrument have USB connectivity?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7753\" data-end=\"7798\"\u003eYes. The LMDO50 provides a \u003cstrong data-start=\"7780\" data-end=\"7797\"\u003eUSB interface\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13myqh8\" dir=\"auto\" data-start=\"7800\" data-end=\"7838\"\u003e12. What accessories are supplied?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7840\" data-end=\"8016\"\u003eStandard accessories include the \u003cstrong data-start=\"7873\" data-end=\"8015\"\u003emain instrument, DO probe, probe membrane cap, USB adaptor, electrode stand, electrolyte solution, instruction manual and test certificate\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52659453690153,"sku":"LMDO50","price":60299.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/rs_w_720_cg_true_12.webp?v=1777055656","url":"https:\/\/www.labmart.in\/products\/labmart-lmdo50-dissolved-oxygen-meter","provider":"Labmart.in","version":"1.0","type":"link"}