{"product_id":"labmart-lmdo4p-portable-dissolved-oxygen-meter","title":"Portable Dissolved Oxygen Meter LMDO4P","description":"\u003cp dir=\"auto\" data-start=\"152\" data-end=\"545\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"156\" data-end=\"206\"\u003eLabmart LMDO4P Portable Dissolved Oxygen Meter\u003c\/strong\u003e is designed for measuring dissolved oxygen concentration and oxygen saturation in liquid samples. It features a \u003cstrong data-start=\"319\" data-end=\"544\"\u003e0.00–20.00 mg\/L measurement range, 0.01 mg\/L resolution, polarographic DO electrode, automatic temperature compensation, manual salinity and pressure correction, 100-data memory, USB connectivity and a backlit LCD display\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"547\" data-end=\"580\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"582\" data-end=\"601\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"603\" data-end=\"899\"\u003eThe \u003cstrong data-start=\"607\" data-end=\"649\"\u003eLMDO4P Portable Dissolved Oxygen Meter\u003c\/strong\u003e is a handheld laboratory instrument for measuring \u003cstrong data-start=\"700\" data-end=\"725\"\u003edissolved oxygen (DO)\u003c\/strong\u003e in liquid samples. The system uses a \u003cstrong data-start=\"763\" data-end=\"807\"\u003epolarographic dissolved oxygen electrode\u003c\/strong\u003e and provides measurements in both dissolved oxygen concentration and percentage saturation.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"901\" data-end=\"1246\"\u003eThe meter supports \u003cstrong data-start=\"920\" data-end=\"949\"\u003e1- or 2-point calibration\u003c\/strong\u003e using air-saturated water or a zero-oxygen solution. Automatic temperature compensation is provided across the specified temperature range, while \u003cstrong data-start=\"1096\" data-end=\"1151\"\u003emanual salinity and barometric-pressure corrections\u003c\/strong\u003e allow compensation for environmental conditions that can affect dissolved oxygen measurements.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1248\" data-end=\"1461\"\u003eThe LMDO4P includes a \u003cstrong data-start=\"1270\" data-end=\"1419\"\u003ebacklit LCD display, selectable manual or automatic measurement hold, 100-data memory, USB communication, automatic power-off and reset functions\u003c\/strong\u003e. A carrying case is supplied as standard.\u003c\/p\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"1463\" data-end=\"1492\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1494\" data-end=\"2670\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1494\" data-end=\"1520\"\u003e\n\u003ctr data-start=\"1494\" data-end=\"1520\"\u003e\n\u003cth data-start=\"1494\" data-end=\"1510\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1510\" data-end=\"1520\" data-col-size=\"md\" class=\"last:pe-10\"\u003eLMDO4P\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1531\" data-end=\"2670\"\u003e\n\u003ctr data-start=\"1531\" data-end=\"1581\"\u003e\n\u003ctd data-start=\"1531\" data-end=\"1546\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"1546\" data-end=\"1581\" data-col-size=\"md\"\u003ePortable Dissolved Oxygen Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1582\" data-end=\"1600\"\u003e\n\u003ctd data-start=\"1582\" data-end=\"1590\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1590\" data-end=\"1600\" data-col-size=\"md\"\u003eLMDO4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1601\" data-end=\"1620\"\u003e\n\u003ctd data-start=\"1601\" data-end=\"1609\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"1609\" data-end=\"1620\" data-col-size=\"md\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1621\" data-end=\"1671\"\u003e\n\u003ctd data-start=\"1621\" data-end=\"1646\" data-col-size=\"sm\"\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd data-start=\"1646\" data-end=\"1671\" data-col-size=\"md\"\u003e0.00–20.00 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1672\" data-end=\"1721\"\u003e\n\u003ctd data-start=\"1672\" data-end=\"1702\" data-col-size=\"sm\"\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd data-start=\"1702\" data-end=\"1721\" data-col-size=\"md\"\u003e0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1722\" data-end=\"1769\"\u003e\n\u003ctd data-start=\"1722\" data-end=\"1750\" data-col-size=\"sm\"\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1750\" data-end=\"1769\" data-col-size=\"md\"\u003e±0.5 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1770\" data-end=\"1803\"\u003e\n\u003ctd data-start=\"1770\" data-end=\"1789\" data-col-size=\"sm\"\u003eSaturation Range\u003c\/td\u003e\n\u003ctd data-start=\"1789\" data-end=\"1803\" data-col-size=\"md\"\u003e0.0–200.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1804\" data-end=\"1836\"\u003e\n\u003ctd data-start=\"1804\" data-end=\"1828\" data-col-size=\"sm\"\u003eSaturation Resolution\u003c\/td\u003e\n\u003ctd data-start=\"1828\" data-end=\"1836\" data-col-size=\"md\"\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1837\" data-end=\"1868\"\u003e\n\u003ctd data-start=\"1837\" data-end=\"1859\" data-col-size=\"sm\"\u003eSaturation Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1859\" data-end=\"1868\" data-col-size=\"md\"\u003e±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1869\" data-end=\"1900\"\u003e\n\u003ctd data-start=\"1869\" data-end=\"1883\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"1883\" data-end=\"1900\" data-col-size=\"md\"\u003e1 or 2 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1901\" data-end=\"1972\"\u003e\n\u003ctd data-start=\"1901\" data-end=\"1925\" data-col-size=\"sm\"\u003eCalibration Solutions\u003c\/td\u003e\n\u003ctd data-start=\"1925\" data-end=\"1972\" data-col-size=\"md\"\u003eAir-saturated water or zero-oxygen solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1973\" data-end=\"2032\"\u003e\n\u003ctd data-start=\"1973\" data-end=\"2000\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"2000\" data-end=\"2032\" data-col-size=\"md\"\u003e0–50°C \/ 32–122°F, automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2033\" data-end=\"2096\"\u003e\n\u003ctd data-start=\"2033\" data-end=\"2055\" data-col-size=\"sm\"\u003ePressure Correction\u003c\/td\u003e\n\u003ctd data-start=\"2055\" data-end=\"2096\" data-col-size=\"md\"\u003e60.0–113.3 kPa \/ 450–850 mmHg, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2097\" data-end=\"2143\"\u003e\n\u003ctd data-start=\"2097\" data-end=\"2119\" data-col-size=\"sm\"\u003eSalinity Correction\u003c\/td\u003e\n\u003ctd data-start=\"2119\" data-end=\"2143\" data-col-size=\"md\"\u003e0.0–50.0 ppt, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2144\" data-end=\"2169\"\u003e\n\u003ctd data-start=\"2144\" data-end=\"2154\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2154\" data-end=\"2169\" data-col-size=\"md\"\u003eBacklit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2170\" data-end=\"2236\"\u003e\n\u003ctd data-start=\"2170\" data-end=\"2186\" data-col-size=\"sm\"\u003eHold Function\u003c\/td\u003e\n\u003ctd data-start=\"2186\" data-end=\"2236\" data-col-size=\"md\"\u003eManual or automatic after measurement endpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2237\" data-end=\"2282\"\u003e\n\u003ctd data-start=\"2237\" data-end=\"2254\" data-col-size=\"sm\"\u003eAuto Power-Off\u003c\/td\u003e\n\u003ctd data-start=\"2254\" data-end=\"2282\" data-col-size=\"md\"\u003e15 minutes if not in use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2283\" data-end=\"2319\"\u003e\n\u003ctd data-start=\"2283\" data-end=\"2292\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2292\" data-end=\"2319\" data-col-size=\"md\"\u003eUp to 100 data readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2320\" data-end=\"2350\"\u003e\n\u003ctd data-start=\"2320\" data-end=\"2332\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"2332\" data-end=\"2350\" data-col-size=\"md\"\u003e6-pin mini-DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2351\" data-end=\"2384\"\u003e\n\u003ctd data-start=\"2351\" data-end=\"2367\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-start=\"2367\" data-end=\"2384\" data-col-size=\"md\"\u003eUSB Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2385\" data-end=\"2448\"\u003e\n\u003ctd data-start=\"2385\" data-end=\"2400\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2400\" data-end=\"2448\" data-col-size=\"md\"\u003e3 × 1.5V AA batteries or 5V DC power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2449\" data-end=\"2503\"\u003e\n\u003ctd data-start=\"2449\" data-end=\"2464\" data-col-size=\"sm\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd data-start=\"2464\" data-end=\"2503\" data-col-size=\"md\"\u003eApprox. 150 hours without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2504\" data-end=\"2532\"\u003e\n\u003ctd data-start=\"2504\" data-end=\"2520\" data-col-size=\"sm\"\u003eCarrying Case\u003c\/td\u003e\n\u003ctd data-start=\"2520\" data-end=\"2532\" data-col-size=\"md\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2533\" data-end=\"2557\"\u003e\n\u003ctd data-start=\"2533\" data-end=\"2550\" data-col-size=\"sm\"\u003eReset Function\u003c\/td\u003e\n\u003ctd data-start=\"2550\" data-end=\"2557\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2558\" data-end=\"2579\"\u003e\n\u003ctd data-start=\"2558\" data-end=\"2572\" data-col-size=\"sm\"\u003eDate \u0026amp; Time\u003c\/td\u003e\n\u003ctd data-start=\"2572\" data-end=\"2579\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2580\" data-end=\"2622\"\u003e\n\u003ctd data-start=\"2580\" data-end=\"2601\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2601\" data-end=\"2622\" data-col-size=\"md\"\u003e345 × 85 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2623\" data-end=\"2646\"\u003e\n\u003ctd data-start=\"2623\" data-end=\"2638\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"2638\" data-end=\"2646\" data-col-size=\"md\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2647\" data-end=\"2670\"\u003e\n\u003ctd data-start=\"2647\" data-end=\"2658\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"2658\" data-end=\"2670\" data-col-size=\"md\"\u003e90275090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"2672\" data-end=\"2805\"\u003e\u003cstrong data-start=\"2672\" data-end=\"2697\"\u003eStandard Accessories:\u003c\/strong\u003e Main instrument, DO electrode, electrolyte solution, membrane cap, instruction manual and test certificate.\u003c\/p\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"2807\" data-end=\"2824\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"2826\" data-end=\"2885\"\u003eThe LMDO4P is suitable for dissolved oxygen measurement in:\u003c\/p\u003e\n\u003cul data-start=\"2887\" data-end=\"3147\"\u003e\n\u003cli data-section-id=\"qeh43v\" data-start=\"2887\" data-end=\"2910\"\u003eWater-quality testing\u003c\/li\u003e\n\u003cli data-section-id=\"1m89z0c\" data-start=\"2911\" data-end=\"2937\"\u003eEnvironmental monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"170v917\" data-start=\"2938\" data-end=\"2959\"\u003eWastewater analysis\u003c\/li\u003e\n\u003cli data-section-id=\"p02ge8\" data-start=\"2960\" data-end=\"2973\"\u003eAquaculture\u003c\/li\u003e\n\u003cli data-section-id=\"193e381\" data-start=\"2974\" data-end=\"3004\"\u003eWater-treatment laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1iu5xdh\" data-start=\"3005\" data-end=\"3033\"\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"3034\" data-end=\"3057\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"n3djqi\" data-start=\"3058\" data-end=\"3084\"\u003eEducational laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"95ehei\" data-start=\"3085\" data-end=\"3120\"\u003eGeneral laboratory water analysis\u003c\/li\u003e\n\u003cli data-section-id=\"18hf2xm\" data-start=\"3121\" data-end=\"3147\"\u003eDissolved oxygen studies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3149\" data-end=\"3166\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3168\" data-end=\"3195\"\u003eThe LMDO4P is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3197\" data-end=\"3448\"\u003e\n\u003cli data-section-id=\"1iu5xdh\" data-start=\"3197\" data-end=\"3225\"\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ox5wdz\" data-start=\"3226\" data-end=\"3254\"\u003eWater-treatment facilities\u003c\/li\u003e\n\u003cli data-section-id=\"1mnoogc\" data-start=\"3255\" data-end=\"3280\"\u003eWastewater laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"e1fbop\" data-start=\"3281\" data-end=\"3307\"\u003eAquaculture applications\u003c\/li\u003e\n\u003cli data-section-id=\"1t31nfa\" data-start=\"3308\" data-end=\"3331\"\u003eResearch institutions\u003c\/li\u003e\n\u003cli data-section-id=\"167fuah\" data-start=\"3332\" data-end=\"3359\"\u003eUniversities and colleges\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3360\" data-end=\"3390\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"11i7961\" data-start=\"3391\" data-end=\"3420\"\u003eField water-quality testing\u003c\/li\u003e\n\u003cli data-section-id=\"nwepf0\" data-start=\"3421\" data-end=\"3448\"\u003eLaboratory water analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"5988\" data-end=\"5998\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"5m1319\" dir=\"auto\" data-start=\"6000\" data-end=\"6035\"\u003e1. What is the LMDO4P used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6037\" data-end=\"6145\"\u003eThe LMDO4P is used for measuring \u003cstrong data-start=\"6070\" data-end=\"6126\"\u003edissolved oxygen concentration and oxygen saturation\u003c\/strong\u003e in liquid samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"gp5v42\" dir=\"auto\" data-start=\"6147\" data-end=\"6201\"\u003e2. What is the dissolved oxygen measurement range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6203\" data-end=\"6242\"\u003eThe range is \u003cstrong data-start=\"6216\" data-end=\"6241\"\u003e0.00–20.00 mg\/L (ppm)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hzuxl4\" dir=\"auto\" data-start=\"6244\" data-end=\"6277\"\u003e3. What is the DO resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6279\" data-end=\"6317\"\u003eThe resolution is \u003cstrong data-start=\"6297\" data-end=\"6316\"\u003e0.01 mg\/L (ppm)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"9m9hik\" dir=\"auto\" data-start=\"6319\" data-end=\"6364\"\u003e4. What is the dissolved oxygen accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6366\" data-end=\"6412\"\u003eThe specified accuracy is \u003cstrong data-start=\"6392\" data-end=\"6411\"\u003e±0.5 mg\/L (ppm)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"rhz8zj\" dir=\"auto\" data-start=\"6414\" data-end=\"6462\"\u003e5. Can the LMDO4P measure oxygen saturation?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6464\" data-end=\"6534\"\u003eYes. The saturation range is \u003cstrong data-start=\"6493\" data-end=\"6507\"\u003e0.0–200.0%\u003c\/strong\u003e, with \u003cstrong data-start=\"6514\" data-end=\"6533\"\u003e0.1% resolution\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"199faq3\" dir=\"auto\" data-start=\"6536\" data-end=\"6577\"\u003e6. What type of DO electrode is used?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6579\" data-end=\"6642\"\u003eThe LMDO4P uses a \u003cstrong data-start=\"6597\" data-end=\"6641\"\u003epolarographic dissolved oxygen electrode\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"wmsvcv\" dir=\"auto\" data-start=\"6644\" data-end=\"6699\"\u003e7. Does it have automatic temperature compensation?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6701\" data-end=\"6777\"\u003eYes. Automatic temperature compensation operates from \u003cstrong data-start=\"6755\" data-end=\"6776\"\u003e0–50°C \/ 32–122°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"xv0hk4\" dir=\"auto\" data-start=\"6779\" data-end=\"6814\"\u003e8. Can salinity be compensated?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6816\" data-end=\"6897\"\u003eYes. The instrument provides \u003cstrong data-start=\"6845\" data-end=\"6896\"\u003emanual salinity correction from 0.0 to 50.0 ppt\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"b0myt\" dir=\"auto\" data-start=\"6899\" data-end=\"6943\"\u003e9. Can barometric pressure be corrected?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6945\" data-end=\"7029\"\u003eYes. Manual pressure correction is available from \u003cstrong data-start=\"6995\" data-end=\"7028\"\u003e60.0–113.3 kPa \/ 450–850 mmHg\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"a35be4\" dir=\"auto\" data-start=\"7031\" data-end=\"7071\"\u003e10. How many readings can be stored?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7073\" data-end=\"7121\"\u003eThe meter can store up to \u003cstrong data-start=\"7099\" data-end=\"7120\"\u003e100 data readings\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"12fx5t2\" dir=\"auto\" data-start=\"7123\" data-end=\"7169\"\u003e11. Does the LMDO4P have USB connectivity?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7171\" data-end=\"7273\"\u003eYes. It provides a \u003cstrong data-start=\"7190\" data-end=\"7221\"\u003eUSB communication interface\u003c\/strong\u003e for data transfer or connection to a power adapter.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yqezdi\" dir=\"auto\" data-start=\"7275\" data-end=\"7308\"\u003e12. What is the battery life?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7310\" data-end=\"7390\"\u003eThe specified battery life is approximately \u003cstrong data-start=\"7354\" data-end=\"7389\"\u003e150 hours without the backlight\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52659555991849,"sku":"LMDO4P","price":36299.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/rs_w_511_cg_true.webp?v=1777055655","url":"https:\/\/www.labmart.in\/products\/labmart-lmdo4p-portable-dissolved-oxygen-meter","provider":"Labmart.in","version":"1.0","type":"link"}