{"product_id":"labmart-lmar1317-digital-abbe-refractometer","title":"Digital Abbe Refractometer LMAR1317","description":"\u003cp dir=\"auto\" data-start=\"133\" data-end=\"504\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"137\" data-end=\"184\"\u003eLabmart LMAR1317 Digital Abbe Refractometer\u003c\/strong\u003e is designed for measuring the refractive index of transparent and translucent liquids and solid substances, as well as Brix of sugar solutions. It features a \u003cstrong data-start=\"343\" data-end=\"503\"\u003e1.3000–1.7000 nD measurement range, 0–100% Brix range, 0.1°C temperature resolution, automatic Brix temperature correction, LCD display and RS232C interface\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"yz0xl2\" dir=\"auto\" data-start=\"506\" data-end=\"539\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"541\" data-end=\"560\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"562\" data-end=\"873\"\u003eThe \u003cstrong data-start=\"566\" data-end=\"605\"\u003eLMAR1317 Digital Abbe Refractometer\u003c\/strong\u003e is a laboratory instrument for measuring the \u003cstrong data-start=\"651\" data-end=\"676\"\u003erefractive index (nD)\u003c\/strong\u003e of transparent or translucent liquids and solid substances. It can also determine the \u003cstrong data-start=\"763\" data-end=\"796\"\u003eBrix value of sugar solutions\u003c\/strong\u003e, with automatic correction for the effect of temperature on the Brix result.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"875\" data-end=\"1086\"\u003eThe instrument uses a \u003cstrong data-start=\"897\" data-end=\"917\"\u003ehard-glass prism\u003c\/strong\u003e, visual aiming system and LCD display. It provides a refractive-index range of \u003cstrong data-start=\"997\" data-end=\"1014\"\u003e1.3000–1.7000\u003c\/strong\u003e, a Brix range of \u003cstrong data-start=\"1032\" data-end=\"1042\"\u003e0–100%\u003c\/strong\u003e, and a temperature resolution of \u003cstrong data-start=\"1076\" data-end=\"1085\"\u003e0.1°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1088\" data-end=\"1287\"\u003eThe instrument also includes an \u003cstrong data-start=\"1120\" data-end=\"1199\"\u003eRS232C interface and printer interface capability for direct data print-out\u003c\/strong\u003e. Sample temperature can optionally be controlled using a refrigerated circulating bath.\u003c\/p\u003e\n\u003ch2 data-section-id=\"939trr\" dir=\"auto\" data-start=\"1289\" data-end=\"1315\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1317\" data-end=\"1917\"\u003e\n\u003cli data-section-id=\"1hzoefp\" data-start=\"1317\" data-end=\"1352\"\u003eDigital Abbe refractometer design\u003c\/li\u003e\n\u003cli data-section-id=\"hash11\" data-start=\"1353\" data-end=\"1413\"\u003eRefractive-index measurement range of \u003cstrong data-start=\"1393\" data-end=\"1413\"\u003e1.3000–1.7000 nD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nbdmqc\" data-start=\"1414\" data-end=\"1443\"\u003e\n\u003cstrong data-start=\"1416\" data-end=\"1431\"\u003e0–100% Brix\u003c\/strong\u003e measurement\u003c\/li\u003e\n\u003cli data-section-id=\"e7v018\" data-start=\"1444\" data-end=\"1488\"\u003e\u003cstrong data-start=\"1446\" data-end=\"1488\"\u003e0.0002 nD or better specified accuracy\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"ehauie\" data-start=\"1489\" data-end=\"1523\"\u003e\u003cstrong data-start=\"1491\" data-end=\"1523\"\u003e0.1°C temperature resolution\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1a507s2\" data-start=\"1524\" data-end=\"1577\"\u003eAutomatic correction of temperature effects on Brix\u003c\/li\u003e\n\u003cli data-section-id=\"728546\" data-start=\"1578\" data-end=\"1630\"\u003eMeasurement of transparent and translucent liquids\u003c\/li\u003e\n\u003cli data-section-id=\"1q6fnsu\" data-start=\"1631\" data-end=\"1673\"\u003eMeasurement of suitable solid substances\u003c\/li\u003e\n\u003cli data-section-id=\"11tr5t1\" data-start=\"1674\" data-end=\"1692\"\u003eHard-glass prism\u003c\/li\u003e\n\u003cli data-section-id=\"1e050t8\" data-start=\"1693\" data-end=\"1715\"\u003eVisual aiming system\u003c\/li\u003e\n\u003cli data-section-id=\"9p0sex\" data-start=\"1716\" data-end=\"1729\"\u003eLCD display\u003c\/li\u003e\n\u003cli data-section-id=\"l5qla7\" data-start=\"1730\" data-end=\"1775\"\u003ePrinter interface for direct data print-out\u003c\/li\u003e\n\u003cli data-section-id=\"vp904c\" data-start=\"1776\" data-end=\"1808\"\u003eRS232C communication interface\u003c\/li\u003e\n\u003cli data-section-id=\"uzfn23\" data-start=\"1809\" data-end=\"1880\"\u003eOptional refrigerated circulating bath for sample-temperature control\u003c\/li\u003e\n\u003cli data-section-id=\"y5vqme\" data-start=\"1881\" data-end=\"1917\"\u003eCompact laboratory benchtop format\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"1919\" data-end=\"1948\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1950\" data-end=\"2737\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1950\" data-end=\"1978\"\u003e\n\u003ctr data-start=\"1950\" data-end=\"1978\"\u003e\n\u003cth data-start=\"1950\" data-end=\"1966\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1966\" data-end=\"1978\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eLMAR1317\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1989\" data-end=\"2737\"\u003e\n\u003ctr data-start=\"1989\" data-end=\"2034\"\u003e\n\u003ctd data-start=\"1989\" data-end=\"2004\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2004\" data-end=\"2034\" data-col-size=\"sm\"\u003eDigital Abbe Refractometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2035\" data-end=\"2055\"\u003e\n\u003ctd data-start=\"2035\" data-end=\"2043\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2043\" data-end=\"2055\" data-col-size=\"sm\"\u003eLMAR1317\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2056\" data-end=\"2075\"\u003e\n\u003ctd data-start=\"2056\" data-end=\"2064\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2064\" data-end=\"2075\" data-col-size=\"sm\"\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2076\" data-end=\"2121\"\u003e\n\u003ctd data-start=\"2076\" data-end=\"2101\" data-col-size=\"sm\"\u003eRefractive Index Range\u003c\/td\u003e\n\u003ctd data-start=\"2101\" data-end=\"2121\" data-col-size=\"sm\"\u003e1.3000–1.7000 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2122\" data-end=\"2166\"\u003e\n\u003ctd data-start=\"2122\" data-end=\"2150\" data-col-size=\"sm\"\u003eRefractive Index Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2150\" data-end=\"2166\" data-col-size=\"sm\"\u003e≤ ±0.0002 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2167\" data-end=\"2209\"\u003e\n\u003ctd data-start=\"2167\" data-end=\"2199\" data-col-size=\"sm\"\u003eBrix \/ Dissolved Solids Range\u003c\/td\u003e\n\u003ctd data-start=\"2199\" data-end=\"2209\" data-col-size=\"sm\"\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2210\" data-end=\"2237\"\u003e\n\u003ctd data-start=\"2210\" data-end=\"2226\" data-col-size=\"sm\"\u003eBrix Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2226\" data-end=\"2237\" data-col-size=\"sm\"\u003e≤ ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2238\" data-end=\"2272\"\u003e\n\u003ctd data-start=\"2238\" data-end=\"2263\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2263\" data-end=\"2272\" data-col-size=\"sm\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2273\" data-end=\"2303\"\u003e\n\u003ctd data-start=\"2273\" data-end=\"2293\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2293\" data-end=\"2303\" data-col-size=\"sm\"\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2304\" data-end=\"2351\"\u003e\n\u003ctd data-start=\"2304\" data-end=\"2340\" data-col-size=\"sm\"\u003eBrix Temperature Correction Range\u003c\/td\u003e\n\u003ctd data-start=\"2340\" data-end=\"2351\" data-col-size=\"sm\"\u003e15–45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2352\" data-end=\"2397\"\u003e\n\u003ctd data-start=\"2352\" data-end=\"2378\" data-col-size=\"sm\"\u003eUsage Temperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2378\" data-end=\"2397\" data-col-size=\"sm\"\u003eAmbient to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2398\" data-end=\"2420\"\u003e\n\u003ctd data-start=\"2398\" data-end=\"2406\" data-col-size=\"sm\"\u003ePrism\u003c\/td\u003e\n\u003ctd data-start=\"2406\" data-end=\"2420\" data-col-size=\"sm\"\u003eHard Glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2421\" data-end=\"2438\"\u003e\n\u003ctd data-start=\"2421\" data-end=\"2431\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2431\" data-end=\"2438\" data-col-size=\"sm\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2439\" data-end=\"2469\"\u003e\n\u003ctd data-start=\"2439\" data-end=\"2455\" data-col-size=\"sm\"\u003eAiming System\u003c\/td\u003e\n\u003ctd data-start=\"2455\" data-end=\"2469\" data-col-size=\"sm\"\u003eVisual Aim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2470\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2470\" data-end=\"2482\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2482\" data-end=\"2492\" data-col-size=\"sm\"\u003eRS232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2552\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2513\" data-col-size=\"sm\"\u003ePrinter Interface\u003c\/td\u003e\n\u003ctd data-start=\"2513\" data-end=\"2552\" data-col-size=\"sm\"\u003eAvailable for direct data print-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2553\" data-end=\"2624\"\u003e\n\u003ctd data-start=\"2553\" data-end=\"2582\" data-col-size=\"sm\"\u003eSample Temperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2582\" data-end=\"2624\" data-col-size=\"sm\"\u003eOptional refrigerated circulating bath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2625\" data-end=\"2660\"\u003e\n\u003ctd data-start=\"2625\" data-end=\"2638\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2638\" data-end=\"2660\" data-col-size=\"sm\"\u003e370 × 240 × 470 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2661\" data-end=\"2694\"\u003e\n\u003ctd data-start=\"2661\" data-end=\"2676\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2676\" data-end=\"2694\" data-col-size=\"sm\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2695\" data-end=\"2713\"\u003e\n\u003ctd data-start=\"2695\" data-end=\"2704\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2704\" data-end=\"2713\" data-col-size=\"sm\"\u003e12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2714\" data-end=\"2737\"\u003e\n\u003ctd data-start=\"2714\" data-end=\"2725\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"2725\" data-end=\"2737\" data-col-size=\"sm\"\u003e90275030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"2739\" data-end=\"2756\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"2758\" data-end=\"2787\"\u003eThe LMAR1317 can be used for:\u003c\/p\u003e\n\u003cul data-start=\"2789\" data-end=\"3161\"\u003e\n\u003cli data-section-id=\"1xjq6vy\" data-start=\"2789\" data-end=\"2819\"\u003eRefractive-index measurement\u003c\/li\u003e\n\u003cli data-section-id=\"pttl3m\" data-start=\"2820\" data-end=\"2857\"\u003eBrix measurement of sugar solutions\u003c\/li\u003e\n\u003cli data-section-id=\"17kuc3i\" data-start=\"2858\" data-end=\"2894\"\u003ePharmaceutical laboratory analysis\u003c\/li\u003e\n\u003cli data-section-id=\"xufp6l\" data-start=\"2895\" data-end=\"2925\"\u003eChemical laboratory analysis\u003c\/li\u003e\n\u003cli data-section-id=\"8s36j1\" data-start=\"2926\" data-end=\"2969\"\u003ePetroleum-related laboratory applications\u003c\/li\u003e\n\u003cli data-section-id=\"76vfpt\" data-start=\"2970\" data-end=\"3009\"\u003eSugar and sugar-refining applications\u003c\/li\u003e\n\u003cli data-section-id=\"ns4i1y\" data-start=\"3010\" data-end=\"3033\"\u003eFood industry testing\u003c\/li\u003e\n\u003cli data-section-id=\"15zomiy\" data-start=\"3034\" data-end=\"3064\"\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"3065\" data-end=\"3088\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"b8bvt5\" data-start=\"3089\" data-end=\"3126\"\u003eCollege and university laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1w3jk51\" data-start=\"3127\" data-end=\"3161\"\u003eScientific research institutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3163\" data-end=\"3180\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\" data-start=\"3182\" data-end=\"3211\"\u003eThe LMAR1317 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3213\" data-end=\"3498\"\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3213\" data-end=\"3242\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"83ik5l\" data-start=\"3243\" data-end=\"3266\"\u003eChemical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ebgev5\" data-start=\"3267\" data-end=\"3299\"\u003eFood and beverage laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1jmiu2h\" data-start=\"3300\" data-end=\"3331\"\u003eSugar-processing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"mccxr8\" data-start=\"3332\" data-end=\"3361\"\u003eSugar-refining laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1knpev4\" data-start=\"3362\" data-end=\"3386\"\u003ePetroleum laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"rlkbyw\" data-start=\"3387\" data-end=\"3416\"\u003eQuality-control departments\u003c\/li\u003e\n\u003cli data-section-id=\"1qoxw4d\" data-start=\"3417\" data-end=\"3435\"\u003eR\u0026amp;D laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"167fuah\" data-start=\"3436\" data-end=\"3463\"\u003eUniversities and colleges\u003c\/li\u003e\n\u003cli data-section-id=\"1w3jk51\" data-start=\"3464\" data-end=\"3498\"\u003eScientific research institutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"5754\" data-end=\"5764\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"aq56bp\" dir=\"auto\" data-start=\"5766\" data-end=\"5803\"\u003e1. What is the LMAR1317 used for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5805\" data-end=\"5967\"\u003eThe LMAR1317 is used to measure the \u003cstrong data-start=\"5841\" data-end=\"5926\"\u003erefractive index of transparent\/translucent liquids and suitable solid substances\u003c\/strong\u003e, as well as the Brix of sugar solutions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1oqd2z3\" dir=\"auto\" data-start=\"5969\" data-end=\"6011\"\u003e2. What is the refractive-index range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6013\" data-end=\"6059\"\u003eThe measurement range is \u003cstrong data-start=\"6038\" data-end=\"6058\"\u003e1.3000–1.7000 nD\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kx7xcp\" dir=\"auto\" data-start=\"6061\" data-end=\"6103\"\u003e3. What is the Brix measurement range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6105\" data-end=\"6145\"\u003eThe instrument measures \u003cstrong data-start=\"6129\" data-end=\"6144\"\u003e0–100% Brix\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1txn9d7\" dir=\"auto\" data-start=\"6147\" data-end=\"6192\"\u003e4. What is the refractive-index accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6194\" data-end=\"6237\"\u003eThe specified accuracy is \u003cstrong data-start=\"6220\" data-end=\"6236\"\u003e≤ ±0.0002 nD\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"rntas7\" dir=\"auto\" data-start=\"6239\" data-end=\"6272\"\u003e5. What is the Brix accuracy?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6274\" data-end=\"6317\"\u003eThe specified Brix accuracy is \u003cstrong data-start=\"6305\" data-end=\"6316\"\u003e≤ ±0.1%\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"4rrnby\" dir=\"auto\" data-start=\"6319\" data-end=\"6387\"\u003e6. Does the LMAR1317 automatically correct Brix for temperature?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6389\" data-end=\"6480\"\u003eYes. The instrument provides \u003cstrong data-start=\"6418\" data-end=\"6479\"\u003eautomatic correction of the effect of temperature on Brix\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"fmq1m\" dir=\"auto\" data-start=\"6482\" data-end=\"6519\"\u003e7. What is the temperature range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6521\" data-end=\"6567\"\u003eThe specified temperature range is \u003cstrong data-start=\"6556\" data-end=\"6566\"\u003e0–50°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ya84k\" dir=\"auto\" data-start=\"6569\" data-end=\"6611\"\u003e8. What is the temperature resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6613\" data-end=\"6653\"\u003eThe temperature resolution is \u003cstrong data-start=\"6643\" data-end=\"6652\"\u003e0.1°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"113nqvo\" dir=\"auto\" data-start=\"6655\" data-end=\"6714\"\u003e9. Can the sample temperature be externally controlled?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6716\" data-end=\"6826\"\u003eYes. A \u003cstrong data-start=\"6723\" data-end=\"6794\"\u003erefrigerated circulating bath is available as an optional accessory\u003c\/strong\u003e for sample-temperature control.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e50fgf\" dir=\"auto\" data-start=\"6828\" data-end=\"6881\"\u003e10. Does the instrument have a printer interface?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6883\" data-end=\"6966\"\u003eYes. The specifications identify a \u003cstrong data-start=\"6918\" data-end=\"6965\"\u003eprinter interface for direct data print-out\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2o9qqj\" dir=\"auto\" data-start=\"6968\" data-end=\"7018\"\u003e11. What communication interface is available?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7020\" data-end=\"7068\"\u003eThe instrument provides an \u003cstrong data-start=\"7047\" data-end=\"7067\"\u003eRS232C interface\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xryumy\" dir=\"auto\" data-start=\"7070\" data-end=\"7111\"\u003e12. What prism does the LMAR1317 use?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7113\" data-end=\"7159\"\u003eThe refractometer uses a \u003cstrong data-start=\"7138\" data-end=\"7158\"\u003ehard-glass prism\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"7183\" data-end=\"7241\"\u003e \u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":67547213922601,"sku":"LMAR1317","price":131699.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/1_a443ff2d-30a7-4c03-8579-f4b55f9b7bb5.png?v=1790594432","url":"https:\/\/www.labmart.in\/products\/labmart-lmar1317-digital-abbe-refractometer","provider":"Labmart.in","version":"1.0","type":"link"}