{"product_id":"labmart-ht-tm05k-type-k-pipe-clamp-thermocouple","title":"Type K Pipe Clamp Thermocouple Sensor  HT-TM05K","description":"\u003cp\u003eThe \u003cstrong\u003eLabmart HT-TM05K Type K Pipe Clamp Thermocouple Sensor\u003c\/strong\u003e is designed for direct temperature measurement of pipes and other circular surfaces. Its spring-loaded clamp provides secure contact, while the 1 m polyurethane lead and miniature Type K plug allow connection to compatible thermometers and multimeters.\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Overview\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe HT-TM05K is a \u003cstrong\u003eType K pipe clamp thermocouple sensor\u003c\/strong\u003e intended for measuring the surface temperature of pipes and circular objects. The spring-loaded jaw helps maintain contact with the measurement surface, making it useful for HVAC, heating, plumbing and general process-temperature checks.\u003c\/p\u003e\n\u003cp\u003eThe sensor accommodates pipe diameters up to \u003cstrong\u003e30 mm\u003c\/strong\u003e and incorporates a Type K thermocouple with a \u003cstrong\u003e1 m polyurethane lead\u003c\/strong\u003e terminated with a miniature Type K plug.\u003c\/p\u003e\n\u003cp\u003eThe contact section is constructed from \u003cstrong\u003eBakelite and glass fibre\u003c\/strong\u003e and is rated for contact temperatures up to \u003cstrong\u003e200°C\u003c\/strong\u003e, while the clamp body is rated up to \u003cstrong\u003e100°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType K thermocouple:\u003c\/strong\u003e Compatible with instruments supporting Type K thermocouple input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30 mm jaw opening:\u003c\/strong\u003e Suitable for pipes and circular surfaces up to the specified jaw capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpring-loaded jaw:\u003c\/strong\u003e Helps maintain firm thermal contact during measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 m polyurethane lead:\u003c\/strong\u003e Provides practical reach between the pipe and measuring instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMiniature Type K plug:\u003c\/strong\u003e Designed for connection to compatible thermometers and multimeters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast response:\u003c\/strong\u003e Specified response time is below 2 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy-grip design:\u003c\/strong\u003e Convenient for routine temperature measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePipe Clamp Thermocouple Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHT-TM05K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Type\u003c\/td\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Code\u003c\/td\u003e\n\u003ctd\u003eANSI MC 96.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp Body Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Length\u003c\/td\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Material\u003c\/td\u003e\n\u003ctd\u003ePolyurethane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination\u003c\/td\u003e\n\u003ctd\u003eMini Type K Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Construction\u003c\/td\u003e\n\u003ctd\u003eBakelite and glass fibre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp Mechanism\u003c\/td\u003e\n\u003ctd\u003eSpring-loaded jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Measurement\u003c\/td\u003e\n\u003ctd\u003ePipe and circular-surface temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Instrument\u003c\/td\u003e\n\u003ctd\u003eThermometer or multimeter supporting Type K thermocouple input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003e5. Applications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003ePipe surface temperature measurement\u003c\/li\u003e\n\u003cli\u003eHVAC temperature testing\u003c\/li\u003e\n\u003cli\u003eHeating system inspection\u003c\/li\u003e\n\u003cli\u003eVentilation system testing\u003c\/li\u003e\n\u003cli\u003eAir-conditioning service\u003c\/li\u003e\n\u003cli\u003ePlumbing temperature measurement\u003c\/li\u003e\n\u003cli\u003eProcess pipe monitoring\u003c\/li\u003e\n\u003cli\u003eHot-water pipe testing\u003c\/li\u003e\n\u003cli\u003eEquipment maintenance\u003c\/li\u003e\n\u003cli\u003eLaboratory temperature measurements on compatible surfaces\u003c\/li\u003e\n\u003cli\u003eGeneral industrial temperature inspection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e6. Suitable For\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC technicians\u003c\/li\u003e\n\u003cli\u003ePlumbing professionals\u003c\/li\u003e\n\u003cli\u003eMaintenance engineers\u003c\/li\u003e\n\u003cli\u003eElectrical and instrumentation technicians\u003c\/li\u003e\n\u003cli\u003eIndustrial service engineers\u003c\/li\u003e\n\u003cli\u003eProcess laboratories\u003c\/li\u003e\n\u003cli\u003eQuality-control teams\u003c\/li\u003e\n\u003cli\u003eHeating and ventilation service teams\u003c\/li\u003e\n\u003cli\u003eResearch and educational laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e7. Product Benefits\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eDirect contact measurement on pipes and circular surfaces\u003c\/li\u003e\n\u003cli\u003eSecure grip during measurement\u003c\/li\u003e\n\u003cli\u003eSupports measurement over a broad specified temperature range at the contact point\u003c\/li\u003e\n\u003cli\u003eCompact and easy to handle\u003c\/li\u003e\n\u003cli\u003e1 m cable provides useful working reach\u003c\/li\u003e\n\u003cli\u003eQuick response for routine temperature checks\u003c\/li\u003e\n\u003cli\u003eCompatible with Type K thermocouple-capable instruments\u003c\/li\u003e\n\u003cli\u003eUseful for field service and maintenance applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hsetin","offers":[{"title":"Default Title","offer_id":54037245919529,"sku":"HT-TM05K","price":1199.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/1_0a5f288a-79cd-42d1-ace0-03c833e0c415.webp?v=1789381664","url":"https:\/\/www.labmart.in\/products\/labmart-ht-tm05k-type-k-pipe-clamp-thermocouple","provider":"Labmart.in","version":"1.0","type":"link"}