{"product_id":"labmart-dbi15sh-dry-bath-incubator","title":"Dry Bath Incubator – DBI15SH","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLabmart DBI15SH Dry Bath Incubator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an automated laboratory dry bath combining \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estirring and heating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in a single instrument. It features microprocessor technology, a holographic projection display, multipoint cycle operation with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e9-stage programmable control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, continuous operation at irregular intervals, timing and alarm functions, and built-in over-temperature protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe DBI15SH provides a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200–2000 RPM stirring range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, heating from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eroom temperature +5°C to 100°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and a standard \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35-hole × 2 mL block\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Optional interchangeable blocks are available for different tube formats. \u003c\/span\u003e\u003cspan\u003e DBI15SH\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan\u003e3. Detailed Product Description\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDBI15SH Dry Bath Incubator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed as an automated and intelligent laboratory tool for processes involving \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esample incubation, catalysis, mixing and other reaction processes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike a conventional dry bath that only provides heating, the DBI15SH combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtrolled heating with stirring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing samples to be mixed while being maintained at the selected temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe catalogue specifies a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200–2000 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e stirring range and a heating temperature range of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eR.T. +5°C to 100°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The standard block has \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35 holes for 2 mL tubes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while several optional blocks allow the instrument to accommodate tube formats ranging from 0.2 mL tubes through 50 mL tubes. \u003c\/span\u003e\u003cspan\u003e DBI15SH\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e DBI15SH\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe product images on pages 1–2 show the DBI15SH as a compact benchtop instrument with a top-mounted sample block, protective cover and front digital\/holographic display.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan\u003e4. Key Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStirring + Heating Operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Combines sample mixing and controlled heating.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e200–2000 RPM Stirring Range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Provides adjustable stirring speed.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeating up to 100°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Temperature range from R.T. +5°C to 100°C.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHolographic Projection Display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Modern digital display interface.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e9-Stage Programmable Operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Supports multipoint cycle operation with 9-stage programming.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMicroprocessor Technology\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Provides automated control of operating parameters.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIrregular-Interval Continuous Operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Allows continuous operation at irregular intervals.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e35-Hole × 2 mL Standard Block\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Suitable for standard 2 mL sample tubes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInterchangeable Block Modules\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Optional blocks can be selected and replaced for different tube sizes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTiming Function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Supports timed operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAlarm Function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Built-in alarm functionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOver-Temperature Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Helps protect the system during excessive-temperature conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh Temperature Uniformity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Metal cabinet design with high temperature uniformity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMultiple Sample Formats\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Optional blocks accommodate a broad range of tube sizes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eABS Protection Cover\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Supplied as a standard accessory.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe salient-features section specifically identifies the holographic display, 9-stage programming, microprocessor technology, timing, alarm and over-temperature protection. \u003c\/span\u003e\u003cspan\u003e DBI15SH\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan\u003e5. Technical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDBI15SH\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDry Bath Incubator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDBI15SH\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMake\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLABMAN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStirring \u0026amp; Heating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStirring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e200–2000 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eR.T. +5°C to 100°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e140 W\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTiming Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWhite LED Display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Block\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e35 holes × 2 mL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Temperature Stability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e≤ ±0.3°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOver-Temperature Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e0.1°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeating Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e5–10 min\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e10°C–30°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC 220 V \/ 50–60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePacking Dimensions (L × W × H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e330 × 280 × 280 mm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGross Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e9 kg\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHSN Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e84798200\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThe above values are taken from the dedicated DBI15SH\/DBI16SC specification table on page 3. \u003c\/span\u003e\u003cspan\u003e DBI15SH\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan\u003e6. Optional Block Modules\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eOne of the major advantages of the DBI15SH is its optional interchangeable block system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eBlock\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eTube Configuration\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHole Size\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBlock A\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 mL × 96\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.7 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBlock H\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 mL × 32 + 0.5 mL × 10 + 1.5 mL × 15\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.1 \/ 8 \/ 10.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBlock B\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 mL × 54\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBlock D\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mL × 35\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBlock F\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 mL × 24\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBlock K\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mL × 24\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBlock L\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 mL × 12\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16.9 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBlock M\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mL × 6\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThese configurations and hole sizes are specified in the optional-block table on page 3. \u003c\/span\u003e\u003cspan\u003e DBI15SH\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant Shopify Listing Note\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35 × 2 mL block is the standard block\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The other block configurations should be presented as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoptional accessories\/modules\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not as included standard accessories. \u003c\/span\u003e\u003cspan\u003e DBI15SH\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan\u003e7. Applications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe catalogue describes the DBI15SH\/DBI16SC series as suitable for laboratory processes including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eSample incubation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eCatalysis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eMixing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eOther reaction processes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor the DBI15SH specifically, the relevant operating function is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estirring and heating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e DBI15SH\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePractical applications can include laboratory sample preparation and temperature-controlled mixing where the required sample volume and tube format are compatible with the selected block.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan\u003e8. Suitable For\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eResearch laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBiotechnology laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMolecular biology laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEducational laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSample preparation laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLaboratories requiring simultaneous heating and mixing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReaction-process laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLaboratories working with multiple tube sizes\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003e9. FAQs\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003e1. What is the Labmart DBI15SH?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe DBI15SH is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDry Bath Incubator with stirring and heating functions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e2. What is the difference between DBI15SH and DBI16SC?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDBI15SH provides stirring and heating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDBI16SC provides stirring, heating and cooling\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e DBI15SH\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e3. What is the stirring speed range?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe DBI15SH has a stirring range of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200–2000 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e4. What is the heating temperature range?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe heating range is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eR.T. +5°C to 100°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e5. What is the standard block capacity?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe standard block has \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35 holes × 2 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e6. Can different tube sizes be used?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. Optional interchangeable block modules are available for different tube sizes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e7. What is the largest optional tube configuration?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe listed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBlock M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e accommodates \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50 mL × 6\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e tubes with a 29.5 mm hole size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e8. Does the DBI15SH have programmable operation?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. The catalogue specifies \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e9-stage programmable multipoint cycle operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e9. Does it have an alarm?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. An alarm function is specified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e10. Does it have over-temperature protection?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. Built-in over-temperature protection is specified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e11. What is the temperature stability of the module?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe specified module temperature stability is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e≤ ±0.3°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e12. What is the display accuracy?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe specified display accuracy is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.1°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e13. What is the heating time?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe catalogue specifies a heating time of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5–10 minutes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e14. What is the power consumption?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe specified power is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e140 W\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e15. What power supply is required?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAC 220 V \/ 50–60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e16. What is the weight?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe listed gross weight is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e9 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e17. Is the block included?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estandard block\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is included. Additional block configurations are optional.\u003c\/span\u003e\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":51959553556777,"sku":"DBI15SH","price":594599.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/61duiIzF-aL._AC_UF1000_1000_QL80.jpg?v=1777306564","url":"https:\/\/www.labmart.in\/products\/labmart-dbi15sh-dry-bath-incubator","provider":"Labmart.in","version":"1.0","type":"link"}