{"product_id":"hsetin-ht-6896-high-temp-ir-thermometer-type-k","title":"HSETIN HT-6896 HIGH TEMP IR THERMOMETER WITH TYPE K","description":"\u003cp\u003eThe \u003cstrong\u003eHSETIN HT-6896 High Temperature IR Thermometer with Type K\u003c\/strong\u003e is a professional handheld temperature-measuring instrument designed for high-temperature industrial and laboratory applications. It combines \u003cstrong\u003enon-contact infrared measurement up to 1350°C\u003c\/strong\u003e with a \u003cstrong\u003eType K thermocouple input up to 1370°C\u003c\/strong\u003e, providing flexibility for both surface and contact temperature measurement.\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Overview\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eLabmart HSETIN HT-6896\u003c\/strong\u003e is designed for measuring the temperature of surfaces where conventional contact thermometers may be unsuitable, unsafe or impractical.\u003c\/p\u003e\n\u003cp\u003eIts infrared mode provides non-contact measurement across a wide \u003cstrong\u003e-50°C to 1350°C\u003c\/strong\u003e range, while the Type K input extends contact measurement capability to \u003cstrong\u003e-50°C to 1370°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003e50:1 distance-to-spot ratio\u003c\/strong\u003e, adjustable emissivity, fast response, backlit LCD and multiple measurement functions, the HT-6896 is suitable for high-temperature inspection, maintenance, process monitoring and laboratory applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-temperature infrared measurement up to \u003cstrong\u003e1350°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eType K thermocouple measurement up to \u003cstrong\u003e1370°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eNon-contact infrared measurement\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e50:1 distance-to-spot ratio\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAdjustable emissivity from \u003cstrong\u003e0.10 to 1.0\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFast response of \u003cstrong\u003eless than 150 ms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e0.1°C\/°F resolution\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eBacklit LCD display\u003c\/li\u003e\n\u003cli\u003e°C\/°F selection\u003c\/li\u003e\n\u003cli\u003eMaximum, minimum, difference and average functions\u003c\/li\u003e\n\u003cli\u003eAutomatic data hold\u003c\/li\u003e\n\u003cli\u003eAutomatic power-off\u003c\/li\u003e\n\u003cli\u003eLaser targeting\u003c\/li\u003e\n\u003cli\u003eOver-range indication\u003c\/li\u003e\n\u003cli\u003e8–14 µm spectral response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh Temperature Infrared Thermometer with Type K Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHT-6896\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eLabmart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOriginal Series\u003c\/td\u003e\n\u003ctd\u003eHSETIN HT-6896\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eNon-contact infrared + Type K contact measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR Temperature Range\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e-50°C to 1350°C\u003c\/strong\u003e (-58°F to 2462°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K Temperature Range\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e-50°C to 1370°C\u003c\/strong\u003e (-58°F to 2498°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1° up to 2000°F; 1° above 2000°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;150 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Resolution \/ D:S Ratio\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50:1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd\u003eAdjustable 0.10–1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Response\u003c\/td\u003e\n\u003ctd\u003e8–14 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eBacklit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser Targeting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Units\u003c\/td\u003e\n\u003ctd\u003e°C \/ °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Functions\u003c\/td\u003e\n\u003ctd\u003eMAX \/ MIN \/ DIF \/ AVG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-Range Indication\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Power-Off\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e260 × 155 × 54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 295 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eABS\/plastic housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial \/ Laboratory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K Probe\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripod Support\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrying Case\u003c\/td\u003e\n\u003ctd\u003eSupplied configuration may include carrying bag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eNot specified by the manufacturer in the available product information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003e5. Applications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-temperature industrial inspection\u003c\/li\u003e\n\u003cli\u003eFurnace and kiln temperature monitoring\u003c\/li\u003e\n\u003cli\u003eMetal processing\u003c\/li\u003e\n\u003cli\u003eFoundry applications\u003c\/li\u003e\n\u003cli\u003eWelding and fabrication\u003c\/li\u003e\n\u003cli\u003eHeat-treatment processes\u003c\/li\u003e\n\u003cli\u003eElectrical equipment inspection\u003c\/li\u003e\n\u003cli\u003eMachinery maintenance\u003c\/li\u003e\n\u003cli\u003eHVAC and heating-system inspection\u003c\/li\u003e\n\u003cli\u003eChemical and process industries\u003c\/li\u003e\n\u003cli\u003eLaboratory temperature measurement\u003c\/li\u003e\n\u003cli\u003eIndustrial preventive maintenance\u003c\/li\u003e\n\u003cli\u003eHot-surface inspection\u003c\/li\u003e\n\u003cli\u003eProcess troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003e6. Suitable For\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturing industries\u003c\/li\u003e\n\u003cli\u003eFoundries and metal-processing facilities\u003c\/li\u003e\n\u003cli\u003eEngineering workshops\u003c\/li\u003e\n\u003cli\u003eElectrical maintenance teams\u003c\/li\u003e\n\u003cli\u003eMechanical maintenance departments\u003c\/li\u003e\n\u003cli\u003eLaboratories\u003c\/li\u003e\n\u003cli\u003eResearch and development facilities\u003c\/li\u003e\n\u003cli\u003eQuality-control departments\u003c\/li\u003e\n\u003cli\u003eHVAC technicians\u003c\/li\u003e\n\u003cli\u003eFurnace and kiln operators\u003c\/li\u003e\n\u003cli\u003eIndustrial service engineers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003e7. Product Benefits\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVery high temperature capability:\u003c\/strong\u003e IR measurement up to 1350°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual measurement technology:\u003c\/strong\u003e Combines infrared and Type K measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe non-contact inspection:\u003c\/strong\u003e Allows measurement of hot or difficult-to-reach surfaces from a distance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50:1 optical ratio:\u003c\/strong\u003e Supports measurement of relatively small targets from greater distances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVery fast response:\u003c\/strong\u003e Less than 150 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable emissivity:\u003c\/strong\u003e Allows settings to be adapted to different surface characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple statistical functions:\u003c\/strong\u003e MAX, MIN, DIF and AVG assist with temperature analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBacklit display:\u003c\/strong\u003e Convenient for industrial working environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable design:\u003c\/strong\u003e Suitable for field maintenance and inspection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hsetin","offers":[{"title":"Default Title","offer_id":54008942592297,"sku":"HT-6896","price":12799.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/1_90cdbc50-312d-4719-a6a1-353a6823509d.jpg?v=1789362643","url":"https:\/\/www.labmart.in\/products\/hsetin-ht-6896-high-temp-ir-thermometer-type-k","provider":"Labmart.in","version":"1.0","type":"link"}