{"product_id":"emr4-elisa-microplate-reader","title":"EMR4 ELISA Microplate Reader – 96-Well Absorbance Microplate Reader","description":"\u003cp dir=\"auto\" data-start=\"125\" data-end=\"573\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"129\" data-end=\"169\"\u003eLabmart EMR4 ELISA Microplate Reader\u003c\/strong\u003e is a specialized microplate analysis instrument designed for ELISA applications and scientific research requiring accurate and reliable absorbance measurement of samples in \u003cstrong data-start=\"343\" data-end=\"361\"\u003e96-well plates\u003c\/strong\u003e. It features a \u003cstrong data-start=\"377\" data-end=\"534\"\u003e7-inch colour touchscreen, Android operating system, halogen lamp, 8-position filter wheel and built-in software for instrument control and data analysis\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"536\" data-content-reference-end=\"566\"\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"610\" data-end=\"629\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"631\" data-end=\"926\"\u003eThe \u003cstrong data-start=\"635\" data-end=\"667\"\u003eEMR4 ELISA Microplate Reader\u003c\/strong\u003e is designed for enzyme-linked immunosorbent assay applications. The instrument uses a \u003cstrong data-start=\"754\" data-end=\"788\"\u003efixed-wavelength filter system\u003c\/strong\u003e to measure light absorbance in microplates and provides a means to quantify substances through analysis of colour changes in ELISA tests.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"928\" data-end=\"1205\"\u003eThe supplied 2025–26 catalogue specifies an \u003cstrong data-start=\"972\" data-end=\"999\"\u003e8-position filter wheel\u003c\/strong\u003e, with four standard filters included at \u003cstrong data-start=\"1040\" data-end=\"1077\"\u003e405 nm, 450 nm, 492 nm and 630 nm\u003c\/strong\u003e, while allowing up to eight filters to be loaded. The wavelength range is \u003cstrong data-start=\"1152\" data-end=\"1166\"\u003e340–750 nm\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"1161\" data-content-reference-end=\"1191\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1207\" data-end=\"1532\"\u003eThe EMR4 provides both \u003cstrong data-start=\"1230\" data-end=\"1269\"\u003eStandard and Fast measurement modes\u003c\/strong\u003e, with whole-plate detection of a 96-hole plate in less than 6 seconds in fast measurement mode. It also incorporates automatic calibration and positioning, instrument self-diagnostics, built-in software and USB connectivity. \u003cspan class=\"contents\" data-content-reference-start=\"1481\" data-content-reference-end=\"1511\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"5m7ztm\" dir=\"auto\" data-start=\"1534\" data-end=\"1562\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1mowsmp\" dir=\"auto\" data-start=\"1564\" data-end=\"1593\"\u003e7-Inch Colour Touchscreen\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1595\" data-end=\"1690\"\u003eThe EMR4 features a \u003cstrong data-start=\"1615\" data-end=\"1644\"\u003e7-inch colour touchscreen\u003c\/strong\u003e for instrument operation and viewing results.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1lpm3as\" dir=\"auto\" data-start=\"1692\" data-end=\"1719\"\u003eAndroid-Based Operation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1721\" data-end=\"1849\"\u003eThe instrument uses an \u003cstrong data-start=\"1744\" data-end=\"1772\"\u003eAndroid operating system\u003c\/strong\u003e, providing the platform for its built-in software and touchscreen interface.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11vvz89\" dir=\"auto\" data-start=\"1851\" data-end=\"1878\"\u003e8-Position Filter Wheel\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1880\" data-end=\"2013\"\u003eThe filter system provides \u003cstrong data-start=\"1907\" data-end=\"1929\"\u003e8 filter positions\u003c\/strong\u003e, with four standard filters supplied and provision for loading up to eight filters.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1gs79wu\" dir=\"auto\" data-start=\"2015\" data-end=\"2035\"\u003eStandard Filters\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2037\" data-end=\"2070\"\u003eThe standard filter set includes:\u003c\/p\u003e\n\u003cul data-start=\"2072\" data-end=\"2107\"\u003e\n\u003cli data-section-id=\"gti7yy\" data-start=\"2072\" data-end=\"2080\"\u003e405 nm\u003c\/li\u003e\n\u003cli data-section-id=\"gsv0u2\" data-start=\"2081\" data-end=\"2089\"\u003e450 nm\u003c\/li\u003e\n\u003cli data-section-id=\"gq2w1g\" data-start=\"2090\" data-end=\"2098\"\u003e492 nm\u003c\/li\u003e\n\u003cli data-section-id=\"i4vk1q\" data-start=\"2099\" data-end=\"2107\"\u003e630 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"8jeh6n\" dir=\"auto\" data-start=\"2109\" data-end=\"2134\"\u003eWide Wavelength Range\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2136\" data-end=\"2185\"\u003eThe specified wavelength range is \u003cstrong data-start=\"2170\" data-end=\"2184\"\u003e340–750 nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"jv4ssj\" dir=\"auto\" data-start=\"2187\" data-end=\"2228\"\u003eAutomatic Calibration and Positioning\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2230\" data-end=\"2338\"\u003eThe EMR4 incorporates an \u003cstrong data-start=\"2255\" data-end=\"2294\"\u003eAuto Calibration Positioning System\u003c\/strong\u003e for instrument calibration and positioning.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cuzb43\" dir=\"auto\" data-start=\"2340\" data-end=\"2360\"\u003eSelf-Diagnostics\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2362\" data-end=\"2443\"\u003eThe system provides self-checking for the \u003cstrong data-start=\"2404\" data-end=\"2442\"\u003eoptical path and mechanical motion\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1s491d8\" dir=\"auto\" data-start=\"2445\" data-end=\"2484\"\u003eStandard and Fast Measurement Modes\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2486\" data-end=\"2522\"\u003eTwo measurement modes are specified:\u003c\/p\u003e\n\u003cul data-start=\"2524\" data-end=\"2575\"\u003e\n\u003cli data-section-id=\"pp1f8a\" data-start=\"2524\" data-end=\"2551\"\u003eStandard measurement mode\u003c\/li\u003e\n\u003cli data-section-id=\"me3z0h\" data-start=\"2552\" data-end=\"2575\"\u003eFast measurement mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"in5rc8\" dir=\"auto\" data-start=\"2577\" data-end=\"2607\"\u003eFast 96-Well Plate Reading\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2609\" data-end=\"2725\"\u003eThe specified measuring speed is \u003cstrong data-start=\"2642\" data-end=\"2724\"\u003eless than 6 seconds for whole 96-hole plate detection in fast measurement mode\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"av5lgp\" dir=\"auto\" data-start=\"2727\" data-end=\"2755\"\u003eBuilt-In Data Management\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2757\" data-end=\"2837\"\u003eThe system provides memory for \u003cstrong data-start=\"2788\" data-end=\"2836\"\u003e200 programs and 100,000 measurement results\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"19tvldx\" dir=\"auto\" data-start=\"2839\" data-end=\"2860\"\u003eBuilt-In Software\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2862\" data-end=\"2962\"\u003eBuilt-in software supports instrument control and data analysis, with \u003cstrong data-start=\"2932\" data-end=\"2952\"\u003e2 USB interfaces\u003c\/strong\u003e provided.\u003c\/p\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2964\" data-end=\"2993\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2995\" data-end=\"4287\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2995\" data-end=\"3043\"\u003e\n\u003ctr data-start=\"2995\" data-end=\"3043\"\u003e\n\u003cth data-start=\"2995\" data-end=\"3011\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3011\" data-end=\"3043\" data-col-size=\"md\" class=\"last:pe-10\"\u003eEMR4 Catalogue Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3054\" data-end=\"4287\"\u003e\n\u003ctr data-start=\"3054\" data-end=\"3091\"\u003e\n\u003ctd data-start=\"3054\" data-end=\"3064\" data-col-size=\"sm\"\u003eProduct\u003c\/td\u003e\n\u003ctd data-start=\"3064\" data-end=\"3091\" data-col-size=\"md\"\u003eElisa Microplate Reader\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3092\" data-end=\"3108\"\u003e\n\u003ctd data-start=\"3092\" data-end=\"3100\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"3100\" data-end=\"3108\" data-col-size=\"md\"\u003eEMR4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3109\" data-end=\"3139\"\u003e\n\u003ctd data-start=\"3109\" data-end=\"3129\" data-col-size=\"sm\"\u003eMake in Catalogue\u003c\/td\u003e\n\u003ctd data-start=\"3129\" data-end=\"3139\" data-col-size=\"md\"\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3140\" data-end=\"3163\"\u003e\n\u003ctd data-start=\"3140\" data-end=\"3151\" data-col-size=\"sm\"\u003eHSN Code\u003c\/td\u003e\n\u003ctd data-start=\"3151\" data-end=\"3163\" data-col-size=\"md\"\u003e90275090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3164\" data-end=\"3198\"\u003e\n\u003ctd data-start=\"3164\" data-end=\"3180\" data-col-size=\"sm\"\u003eFilter Option\u003c\/td\u003e\n\u003ctd data-start=\"3180\" data-end=\"3198\" data-col-size=\"md\"\u003e8 filter wheel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3199\" data-end=\"3255\"\u003e\n\u003ctd data-start=\"3199\" data-end=\"3218\" data-col-size=\"sm\"\u003eStandard Filters\u003c\/td\u003e\n\u003ctd data-start=\"3218\" data-end=\"3255\" data-col-size=\"md\"\u003e4: 405 nm, 450 nm, 492 nm, 630 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3256\" data-end=\"3300\"\u003e\n\u003ctd data-start=\"3256\" data-end=\"3281\" data-col-size=\"sm\"\u003eMaximum Filter Loading\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3281\" data-end=\"3300\"\u003eUp to 8 filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3301\" data-end=\"3331\"\u003e\n\u003ctd data-start=\"3301\" data-end=\"3320\" data-col-size=\"sm\"\u003eFilter Bandwidth\u003c\/td\u003e\n\u003ctd data-start=\"3320\" data-end=\"3331\" data-col-size=\"md\"\u003e8–10 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3332\" data-end=\"3367\"\u003e\n\u003ctd data-start=\"3332\" data-end=\"3348\" data-col-size=\"sm\"\u003eReading Range\u003c\/td\u003e\n\u003ctd data-start=\"3348\" data-end=\"3367\" data-col-size=\"md\"\u003e0.000–4.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3368\" data-end=\"3401\"\u003e\n\u003ctd data-start=\"3368\" data-end=\"3387\" data-col-size=\"sm\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd data-start=\"3387\" data-end=\"3401\" data-col-size=\"md\"\u003e340–750 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3402\" data-end=\"3461\"\u003e\n\u003ctd data-start=\"3402\" data-end=\"3427\" data-col-size=\"sm\"\u003eLinear Range at 405 nm\u003c\/td\u003e\n\u003ctd data-start=\"3427\" data-end=\"3461\" data-col-size=\"md\"\u003e0–3.0 Abs: ±1%; 3–4.0 Abs: ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3462\" data-end=\"3519\"\u003e\n\u003ctd data-start=\"3462\" data-end=\"3483\" data-col-size=\"sm\"\u003eAccuracy at 405 nm\u003c\/td\u003e\n\u003ctd data-start=\"3483\" data-end=\"3519\" data-col-size=\"md\"\u003eAbs ±1% (0–3 Abs), +2% (3–4 Abs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3520\" data-end=\"3587\"\u003e\n\u003ctd data-start=\"3520\" data-end=\"3546\" data-col-size=\"sm\"\u003eAccuracy at 405 nm – CV\u003c\/td\u003e\n\u003ctd data-start=\"3546\" data-end=\"3587\" data-col-size=\"md\"\u003eCV 0.2% (0–3 Abs), CV ≤1.0% (3–4 Abs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3588\" data-end=\"3676\"\u003e\n\u003ctd data-start=\"3588\" data-end=\"3606\" data-col-size=\"sm\"\u003eMeasuring Speed\u003c\/td\u003e\n\u003ctd data-start=\"3606\" data-end=\"3676\" data-col-size=\"md\"\u003e\u0026lt;6 sec, 96-hole plate whole plate detection, fast measurement mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3677\" data-end=\"3703\"\u003e\n\u003ctd data-start=\"3677\" data-end=\"3690\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"3690\" data-end=\"3703\" data-col-size=\"md\"\u003e0.001 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3704\" data-end=\"3760\"\u003e\n\u003ctd data-start=\"3704\" data-end=\"3724\" data-col-size=\"sm\"\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd data-start=\"3724\" data-end=\"3760\" data-col-size=\"md\"\u003eStandard \u0026amp; Fast measurement mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3761\" data-end=\"3792\"\u003e\n\u003ctd data-start=\"3761\" data-end=\"3776\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"3776\" data-end=\"3792\" data-col-size=\"md\"\u003eHalogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3793\" data-end=\"3848\"\u003e\n\u003ctd data-start=\"3793\" data-end=\"3802\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3802\" data-end=\"3848\"\u003e200 programs \u0026amp; 100,000 measurement results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3849\" data-end=\"3889\"\u003e\n\u003ctd data-start=\"3849\" data-end=\"3859\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3859\" data-end=\"3889\"\u003e7-inch Colour Touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3890\" data-end=\"3911\"\u003e\n\u003ctd data-start=\"3890\" data-end=\"3902\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"3902\" data-end=\"3911\" data-col-size=\"md\"\u003e2 USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3912\" data-end=\"3942\"\u003e\n\u003ctd data-start=\"3912\" data-end=\"3931\" data-col-size=\"sm\"\u003eOperating System\u003c\/td\u003e\n\u003ctd data-start=\"3931\" data-end=\"3942\" data-col-size=\"md\"\u003eAndroid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3943\" data-end=\"3996\"\u003e\n\u003ctd data-start=\"3943\" data-end=\"3957\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"3957\" data-end=\"3996\" data-col-size=\"md\"\u003eAuto Calibration Positioning System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3997\" data-end=\"4029\"\u003e\n\u003ctd data-start=\"3997\" data-end=\"4008\" data-col-size=\"sm\"\u003eSoftware\u003c\/td\u003e\n\u003ctd data-start=\"4008\" data-end=\"4029\" data-col-size=\"md\"\u003eBuilt-In Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4030\" data-end=\"4071\"\u003e\n\u003ctd data-start=\"4030\" data-end=\"4064\" data-col-size=\"sm\"\u003eAdjustable Time \u0026amp; Speed Setting\u003c\/td\u003e\n\u003ctd data-start=\"4064\" data-end=\"4071\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4072\" data-end=\"4087\"\u003e\n\u003ctd data-start=\"4072\" data-end=\"4080\" data-col-size=\"sm\"\u003ePower\u003c\/td\u003e\n\u003ctd data-start=\"4080\" data-end=\"4087\" data-col-size=\"md\"\u003e60W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4088\" data-end=\"4121\"\u003e\n\u003ctd data-start=\"4088\" data-end=\"4103\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"4103\" data-end=\"4121\" data-col-size=\"md\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4122\" data-end=\"4169\"\u003e\n\u003ctd data-start=\"4122\" data-end=\"4147\" data-col-size=\"sm\"\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd data-start=\"4147\" data-end=\"4169\" data-col-size=\"md\"\u003e560 × 400 × 325 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4170\" data-end=\"4194\"\u003e\n\u003ctd data-start=\"4170\" data-end=\"4185\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"4185\" data-end=\"4194\" data-col-size=\"md\"\u003e11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4195\" data-end=\"4287\"\u003e\n\u003ctd data-start=\"4195\" data-end=\"4218\" data-col-size=\"sm\"\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd data-start=\"4218\" data-end=\"4287\" data-col-size=\"md\"\u003eMain Instrument, Power Cord, Instruction Manual, Test Certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"4289\" data-end=\"4415\"\u003eThe above specifications are taken directly from the EMR4 catalogue specification table. \u003cspan class=\"contents\" data-content-reference-start=\"4357\" data-content-reference-end=\"4387\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"4417\" data-end=\"4434\"\u003e5. Applications\u003c\/h1\u003e\n\u003cul data-start=\"4436\" data-end=\"4685\"\u003e\n\u003cli data-section-id=\"jcisx8\" data-start=\"4436\" data-end=\"4451\"\u003eELISA testing\u003c\/li\u003e\n\u003cli data-section-id=\"1qtdzsi\" data-start=\"4452\" data-end=\"4487\"\u003eMicroplate absorbance measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1od4uuq\" data-start=\"4488\" data-end=\"4509\"\u003eScientific research\u003c\/li\u003e\n\u003cli data-section-id=\"pf03eu\" data-start=\"4510\" data-end=\"4534\"\u003e96-well plate analysis\u003c\/li\u003e\n\u003cli data-section-id=\"y57at\" data-start=\"4535\" data-end=\"4597\"\u003eQuantification through colour-change analysis in ELISA tests\u003c\/li\u003e\n\u003cli data-section-id=\"1acvxev\" data-start=\"4598\" data-end=\"4629\"\u003eLaboratory sample measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1dj88fn\" data-start=\"4630\" data-end=\"4685\"\u003eResearch involving absorbance-based microplate assays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"4687\" data-end=\"4704\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cul data-start=\"4706\" data-end=\"4977\"\u003e\n\u003cli data-section-id=\"1muvnq7\" data-start=\"4706\" data-end=\"4726\"\u003eELISA laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1or0uhb\" data-start=\"4727\" data-end=\"4755\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"8e0zqn\" data-start=\"4756\" data-end=\"4783\"\u003eBiochemistry laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1f91tmb\" data-start=\"4784\" data-end=\"4822\"\u003ePharmaceutical research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"18s0osb\" data-start=\"4823\" data-end=\"4855\"\u003eClinical research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1jykneb\" data-start=\"4856\" data-end=\"4888\"\u003eAcademic research institutions\u003c\/li\u003e\n\u003cli data-section-id=\"13iafnb\" data-start=\"4889\" data-end=\"4923\"\u003eScientific research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"wzeqg8\" data-start=\"4924\" data-end=\"4977\"\u003eLaboratories performing 96-well microplate analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"7222\" data-end=\"7232\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"vgffs1\" dir=\"auto\" data-start=\"7234\" data-end=\"7258\"\u003e1. What is the EMR4?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7260\" data-end=\"7354\"\u003eThe EMR4 is an \u003cstrong data-start=\"7275\" data-end=\"7302\"\u003eELISA Microplate Reader\u003c\/strong\u003e designed for absorbance measurement in microplates.\u003c\/p\u003e\n\u003ch3 data-section-id=\"uschn5\" dir=\"auto\" data-start=\"7356\" data-end=\"7408\"\u003e2. What type of assays is the EMR4 designed for?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7410\" data-end=\"7525\"\u003eThe catalogue specifically describes the instrument for \u003cstrong data-start=\"7466\" data-end=\"7511\"\u003eenzyme-linked immunosorbent assay (ELISA)\u003c\/strong\u003e applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1wdry8d\" dir=\"auto\" data-start=\"7527\" data-end=\"7570\"\u003e3. How many wells can the EMR4 measure?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7572\" data-end=\"7665\"\u003eThe catalogue specifies \u003cstrong data-start=\"7596\" data-end=\"7635\"\u003e96-hole plate whole-plate detection\u003c\/strong\u003e in its fast measurement mode.\u003c\/p\u003e\n\u003ch3 data-section-id=\"l77ssh\" dir=\"auto\" data-start=\"7667\" data-end=\"7711\"\u003e4. What is the absorbance reading range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7713\" data-end=\"7754\"\u003eThe reading range is \u003cstrong data-start=\"7734\" data-end=\"7753\"\u003e0.000–4.000 Abs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nekqsl\" dir=\"auto\" data-start=\"7756\" data-end=\"7786\"\u003e5. What is the resolution?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7788\" data-end=\"7830\"\u003eThe specified resolution is \u003cstrong data-start=\"7816\" data-end=\"7829\"\u003e0.001 Abs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"uu3kkq\" dir=\"auto\" data-start=\"7832\" data-end=\"7881\"\u003e6. What wavelength range does the EMR4 cover?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7883\" data-end=\"7932\"\u003eThe specified wavelength range is \u003cstrong data-start=\"7917\" data-end=\"7931\"\u003e340–750 nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1okv7f1\" dir=\"auto\" data-start=\"7934\" data-end=\"7989\"\u003e7. How many filters can the instrument accommodate?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7991\" data-end=\"8110\"\u003eThe EMR4 has an \u003cstrong data-start=\"8007\" data-end=\"8034\"\u003e8-position filter wheel\u003c\/strong\u003e. Four standard filters are included, and up to eight filters can be loaded.\u003c\/p\u003e\n\u003ch3 data-section-id=\"z247bt\" dir=\"auto\" data-start=\"8112\" data-end=\"8154\"\u003e8. What standard filters are supplied?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8156\" data-end=\"8235\"\u003eThe catalogue specifies \u003cstrong data-start=\"8180\" data-end=\"8217\"\u003e405 nm, 450 nm, 492 nm and 630 nm\u003c\/strong\u003e standard filters.\u003c\/p\u003e\n\u003ch3 data-section-id=\"gmf82w\" dir=\"auto\" data-start=\"8237\" data-end=\"8273\"\u003e9. What is the filter bandwidth?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8275\" data-end=\"8321\"\u003eThe specified filter bandwidth is \u003cstrong data-start=\"8309\" data-end=\"8320\"\u003e8–10 nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ebvpvs\" dir=\"auto\" data-start=\"8323\" data-end=\"8369\"\u003e10. How fast can the EMR4 measure a plate?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8371\" data-end=\"8478\"\u003eThe catalogue specifies \u003cstrong data-start=\"8395\" data-end=\"8477\"\u003eless than 6 seconds for whole 96-hole plate detection in fast measurement mode\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"9ebzxg\" dir=\"auto\" data-start=\"8480\" data-end=\"8525\"\u003e11. Does the EMR4 have built-in software?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8527\" data-end=\"8619\"\u003eYes. The catalogue specifies \u003cstrong data-start=\"8556\" data-end=\"8577\"\u003ebuilt-in software\u003c\/strong\u003e for instrument control and data analysis.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15zwokp\" dir=\"auto\" data-start=\"8621\" data-end=\"8674\"\u003e12. How much measurement data can the EMR4 store?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8676\" data-end=\"8749\"\u003eThe specified memory is \u003cstrong data-start=\"8700\" data-end=\"8748\"\u003e200 programs and 100,000 measurement results\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"s61ojo\" dir=\"auto\" data-start=\"8751\" data-end=\"8795\"\u003e13. Does the EMR4 have USB connectivity?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8797\" data-end=\"8847\"\u003eYes. The specification lists \u003cstrong data-start=\"8826\" data-end=\"8846\"\u003e2 USB interfaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1po4555\" dir=\"auto\" data-start=\"8849\" data-end=\"8891\"\u003e14. What type of display does it have?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8893\" data-end=\"8938\"\u003eThe EMR4 has a \u003cstrong data-start=\"8908\" data-end=\"8937\"\u003e7-inch colour touchscreen\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13jn6bs\" dir=\"auto\" data-start=\"8940\" data-end=\"8990\"\u003e15. What light source does the instrument use?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"8992\" data-end=\"9041\"\u003eThe specified light source is a \u003cstrong data-start=\"9024\" data-end=\"9040\"\u003ehalogen lamp\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52795664204073,"sku":"EMR4","price":195599.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/rs_w_730_h_730_cg_true_1.jpg?v=1777054927","url":"https:\/\/www.labmart.in\/products\/emr4-elisa-microplate-reader","provider":"Labmart.in","version":"1.0","type":"link"}