{"product_id":"dlab-dcd100-benchtop-conductivity-do-meter","title":"DLAB DCD100 Benchtop Conductivity\/DO Meter","description":"\u003cp\u003eThe DLAB DCD100 is a benchtop meter for conductivity and dissolved oxygen measurement.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-resolution display with white backlight\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration, ATC measurement and parameter setup\u003c\/li\u003e\n\u003cli\u003eAutomatic stable-reading and calibration indication\u003c\/li\u003e\n\u003cli\u003eData storage of 450 readings; export to flash disk or optional wireless printer\u003c\/li\u003e\n\u003cli\u003eSupplied with flexible probe holder and standard solutions\u003c\/li\u003e\n\u003cli\u003eIP54 protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto-ranging 0–200.0 mS\/cm: 0–19.99 µS\/cm; 20.0–199.9 µS\/cm; 200–1999 µS\/cm; 2.00–19.99 mS\/cm; 20.00–199.9 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–100.0 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.00 Ω·cm–100.0 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–100 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.0 % F.S ± 1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity ATC range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0–50.0 °C (32.0–122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00–20.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.30 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO saturation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0–200.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic barometric compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–200.0 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO automatic temperature compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0–50.0 °C (32.0–122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManual salinity compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–45 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−9.9 to 130.0 °C (14.1–266 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData export\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlash disk \/ printer (printer optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 12 V (power adaptor supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelivery period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eSupplied with\u003c\/h3\u003e\u003cp\u003eMeter; DCON201TG glass ATC conductivity probe; standard conductivity solutions 84 µS\/cm, 1413 µS\/cm and 12.88 mS\/cm, 50 mL, one of each; DDO01-2M DO probe, cable length 2 m; DDOS-01 membrane refill solution 30 mL, DDOSC sensor caps (3 pcs\/group, 1 pkg); DF01 flexible probe holder; DA01 power adaptor (as listed in the DLAB price list).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDelivery Period – 10 days.\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the DLAB DCD100 used for?\u003c\/h4\u003e\u003cp\u003eThe DLAB DCD100 is a benchtop meter for conductivity and dissolved oxygen measurement.\u003c\/p\u003e\u003ch4\u003eWhat is supplied with the DCD100?\u003c\/h4\u003e\u003cp\u003eMeter; DCON201TG glass ATC conductivity probe; standard conductivity solutions 84 µS\/cm, 1413 µS\/cm and 12.88 mS\/cm, 50 mL, one of each; DDO01-2M DO probe, cable length 2 m; DDOS-01 membrane refill solution 30 mL, DDOSC sensor caps (3 pcs\/group, 1 pkg); DF01 flexible probe holder; DA01 power adaptor (as listed in the DLAB price list).\u003c\/p\u003e\u003ch4\u003eDoes Labmart provide a GST invoice and bulk or institutional quotation for the DLAB DCD100?\u003c\/h4\u003e\u003cp\u003eYes. GST invoice and bulk or institutional quotations are available; contact us with your quantity.\u003c\/p\u003e\u003ch4\u003eWhat is the HSN code?\u003c\/h4\u003e\u003cp\u003eConfirmed on your quotation and invoice.\u003c\/p\u003e\u003ch4\u003eWhat warranty does it carry?\u003c\/h4\u003e\u003cp\u003eConfirmed in your quotation; please ask before ordering.\u003c\/p\u003e\u003ch4\u003eWhat is the delivery period?\u003c\/h4\u003e\u003cp\u003eDelivery Period – 10 days.\u003c\/p\u003e\u003ch4\u003eCan I order probes, solutions and accessories separately?\u003c\/h4\u003e\u003cp\u003eYes, probes, calibration solutions and other accessories are supplied separately. Contact Labmart with your requirement.\u003c\/p\u003e\u003ch4\u003eHow is it powered?\u003c\/h4\u003e\u003cp\u003eDC 12 V through the DA01 power adaptor supplied.\u003c\/p\u003e\u003ch4\u003eIs installation or training available?\u003c\/h4\u003e\u003cp\u003ePlease contact Labmart; confirmed in your quotation.\u003c\/p\u003e\u003ch4\u003eIs it a genuine DLAB product?\u003c\/h4\u003e\u003cp\u003eYes, supplied under the DLAB brand per the DLAB price list FY26-27.\u003c\/p\u003e","brand":"DLAB","offers":[{"title":"Unit","offer_id":67724452757801,"sku":"4090010208","price":97099.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/DLAB-DPH100-Benchtop.png?v=1793601004","url":"https:\/\/www.labmart.in\/products\/dlab-dcd100-benchtop-conductivity-do-meter","provider":"Labmart.in","version":"1.0","type":"link"}