{"product_id":"automatic-karl-fischer-titrator-kft250vc","title":"Automatic Karl Fischer Titrator I Supports Volumetric \u0026 Coulometric Titration I GMP Complaint I FREE ONSITE INSTALLATION","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong data-start=\"62\" data-end=\"103\"\u003eLABMAN KFT250VC Karl Fischer Titrator\u003c\/strong\u003e\u003cspan\u003e is a high-performance moisture analysis system that combines \u003c\/span\u003e\u003cstrong data-start=\"165\" data-end=\"218\"\u003eVolumetric and Coulometric Karl Fischer titration\u003c\/strong\u003e\u003cspan\u003e in a single instrument, making it suitable for both trace and high moisture determination. Designed for laboratories in pharmaceuticals, chemicals, petrochemicals, food, research, and quality control, it delivers accurate, reliable, and repeatable moisture measurements across a wide range of sample types\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1d7mrtu\" data-start=\"196\" data-end=\"207\" class=\"PDq2pG_selectionAnchorContainer\"\u003eFeatures\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"209\" data-end=\"1439\"\u003e\n\u003cli data-section-id=\"193mlzb\" data-start=\"209\" data-end=\"290\"\u003e\n\u003cp data-start=\"211\" data-end=\"290\"\u003eLCD display with detailed presentation of titration methods, curves and results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kmr9u7\" data-start=\"291\" data-end=\"387\"\u003e\n\u003cp data-start=\"293\" data-end=\"387\"\u003eSupports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"307\" data-end=\"321\"\u003eVolumetric\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"326\" data-end=\"364\"\u003eCoulometric Karl Fischer Titration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein a single instrument\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"bcc0o4\" data-start=\"388\" data-end=\"457\"\u003e\n\u003cp data-start=\"390\" data-end=\"457\"\u003eAdvanced data analysis function for reviewing and comparing results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"vp904c\" data-start=\"458\" data-end=\"490\"\u003e\n\u003cp data-start=\"460\" data-end=\"490\"\u003eRS232C communication interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"106u7mu\" data-start=\"491\" data-end=\"526\"\u003e\n\u003cp data-start=\"493\" data-end=\"526\"\u003eReset and Factory Reset functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"998o5z\" data-start=\"527\" data-end=\"604\"\u003e\n\u003cp data-start=\"529\" data-end=\"604\"\u003eStores up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"542\" data-end=\"569\"\u003e200 titration data sets\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith GLP-compliant data management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"127rumq\" data-start=\"605\" data-end=\"689\"\u003e\n\u003cp data-start=\"607\" data-end=\"689\"\u003eMultiple selectable measurement units including\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"655\" data-end=\"689\"\u003emg, mg\/L, %, ppm, μg and μg\/mL\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19fd0wz\" data-start=\"690\" data-end=\"774\"\u003e\n\u003cp data-start=\"692\" data-end=\"774\"\u003eAutomatic and manual background drift correction for improved measurement accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dyokkr\" data-start=\"775\" data-end=\"840\"\u003e\n\u003cp data-start=\"777\" data-end=\"840\"\u003eGenerator cell with diaphragm for coulometric moisture analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"101fbqy\" data-start=\"841\" data-end=\"931\"\u003e\n\u003cp data-start=\"843\" data-end=\"931\"\u003eAutomatic reagent filling, purging and mixing for safe handling of Karl Fischer reagents\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ucyw26\" data-start=\"932\" data-end=\"1148\"\u003e\n\u003cp data-start=\"934\" data-end=\"983\"\u003eUser-configurable operating parameters including:\u003c\/p\u003e\n\u003cul data-start=\"986\" data-end=\"1148\"\u003e\n\u003cli data-section-id=\"1obsx7o\" data-start=\"986\" data-end=\"1004\"\u003e\n\u003cp data-start=\"988\" data-end=\"1004\"\u003eMeasurement unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qdzbgv\" data-start=\"1007\" data-end=\"1029\"\u003e\n\u003cp data-start=\"1009\" data-end=\"1029\"\u003ePolarization current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zkho4h\" data-start=\"1032\" data-end=\"1048\"\u003e\n\u003cp data-start=\"1034\" data-end=\"1048\"\u003eStirring speed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ef7vpo\" data-start=\"1051\" data-end=\"1067\"\u003e\n\u003cp data-start=\"1053\" data-end=\"1067\"\u003eTitration rate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1np2x1u\" data-start=\"1070\" data-end=\"1089\"\u003e\n\u003cp data-start=\"1072\" data-end=\"1089\"\u003eGenerator current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"75jjme\" data-start=\"1092\" data-end=\"1113\"\u003e\n\u003cp data-start=\"1094\" data-end=\"1113\"\u003eEnd-point potential\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ilohgj\" data-start=\"1116\" data-end=\"1132\"\u003e\n\u003cp data-start=\"1118\" data-end=\"1132\"\u003eStop criterion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1x7zae0\" data-start=\"1135\" data-end=\"1148\"\u003e\n\u003cp data-start=\"1137\" data-end=\"1148\"\u003eStop volume\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gf2do1\" data-start=\"1149\" data-end=\"1311\"\u003e\n\u003cp data-start=\"1151\" data-end=\"1184\"\u003eSupports multiple analysis modes:\u003c\/p\u003e\n\u003cul data-start=\"1187\" data-end=\"1311\"\u003e\n\u003cli data-section-id=\"1nrexb4\" data-start=\"1187\" data-end=\"1206\"\u003e\n\u003cp data-start=\"1189\" data-end=\"1206\"\u003eKF Titration Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kvyz87\" data-start=\"1209\" data-end=\"1234\"\u003e\n\u003cp data-start=\"1211\" data-end=\"1234\"\u003eKF Titer Detection Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10szmu6\" data-start=\"1237\" data-end=\"1272\"\u003e\n\u003cp data-start=\"1239\" data-end=\"1272\"\u003eVolumetric Karl Fischer Titration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1es4f7o\" data-start=\"1275\" data-end=\"1311\"\u003e\n\u003cp data-start=\"1277\" data-end=\"1311\"\u003eCoulometric Karl Fischer Titration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rjxc5r\" data-start=\"1312\" data-end=\"1439\"\u003e\n\u003cp data-start=\"1314\" data-end=\"1439\"\u003eSuitable for both\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1332\" data-end=\"1350\"\u003etrace moisture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1355\" data-end=\"1374\"\u003ehigher moisture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edetermination using dedicated coulometric and volumetric systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1441\" data-end=\"1444\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1446\" data-end=\"1473\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1475\" data-end=\"2507\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1475\" data-end=\"1523\"\u003e\n\u003ctr data-start=\"1475\" data-end=\"1523\"\u003e\n\u003cth data-start=\"1475\" data-end=\"1491\" data-col-size=\"md\" class=\"last:pe-10\"\u003e\u003cstrong data-start=\"1477\" data-end=\"1490\"\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1491\" data-end=\"1523\" data-col-size=\"md\" class=\"last:pe-10\"\u003e\u003cstrong data-start=\"1493\" data-end=\"1521\"\u003eSpecification (KFT250VC)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1602\" data-end=\"2507\"\u003e\n\u003ctr data-start=\"1602\" data-end=\"1626\"\u003e\n\u003ctd data-start=\"1602\" data-end=\"1614\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1604\" data-end=\"1613\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1614\" data-end=\"1626\" data-col-size=\"md\"\u003eKFT250VC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1627\" data-end=\"1648\"\u003e\n\u003ctd data-start=\"1627\" data-end=\"1638\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1629\" data-end=\"1637\"\u003eMake\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1638\" data-end=\"1648\" data-col-size=\"md\"\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1649\" data-end=\"1719\"\u003e\n\u003ctd data-start=\"1649\" data-end=\"1671\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1651\" data-end=\"1670\"\u003eOperating Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1671\" data-end=\"1719\" data-col-size=\"md\"\u003eVolumetric Titration \u0026amp; Coulometric Titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1720\" data-end=\"1772\"\u003e\n\u003ctd data-start=\"1720\" data-end=\"1753\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1722\" data-end=\"1752\"\u003eVolumetric Titration Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1753\" data-end=\"1772\" data-col-size=\"md\"\u003e0.1 mg – 250 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1773\" data-end=\"1850\"\u003e\n\u003ctd data-start=\"1773\" data-end=\"1820\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1819\"\u003eVolumetric Polarization Current Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1820\" data-end=\"1850\" data-col-size=\"md\"\u003e1 μA ±0.2 μA, 50 μA ±10 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1851\" data-end=\"1891\"\u003e\n\u003ctd data-start=\"1851\" data-end=\"1882\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1853\" data-end=\"1881\"\u003eVolumetric Repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1882\" data-end=\"1891\" data-col-size=\"md\"\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1892\" data-end=\"1943\"\u003e\n\u003ctd data-start=\"1892\" data-end=\"1926\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1894\" data-end=\"1925\"\u003eCoulometric Titration Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1926\" data-end=\"1943\" data-col-size=\"md\"\u003e10 μg – 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1944\" data-end=\"2023\"\u003e\n\u003ctd data-start=\"1944\" data-end=\"1992\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1946\" data-end=\"1991\"\u003eCoulometric Polarization Current Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1992\" data-end=\"2023\" data-col-size=\"md\"\u003e50 μA; 1 μA ±0.2 μA, ±10 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2024\" data-end=\"2094\"\u003e\n\u003ctd data-start=\"2024\" data-end=\"2063\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2026\" data-end=\"2062\"\u003eCoulometric Electrolytic Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2063\" data-end=\"2094\" data-col-size=\"md\"\u003e10 mA, 20 mA, 50 mA, 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2095\" data-end=\"2159\"\u003e\n\u003ctd data-start=\"2095\" data-end=\"2143\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2097\" data-end=\"2142\"\u003eCoulometric Electrolytic Current Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2143\" data-end=\"2159\" data-col-size=\"md\"\u003e±(5% + 3) μg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2160\" data-end=\"2199\"\u003e\n\u003ctd data-start=\"2160\" data-end=\"2192\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2162\" data-end=\"2191\"\u003eCoulometric Repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2192\" data-end=\"2199\" data-col-size=\"md\"\u003e≤3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2200\" data-end=\"2229\"\u003e\n\u003ctd data-start=\"2200\" data-end=\"2214\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2202\" data-end=\"2213\"\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2214\" data-end=\"2229\" data-col-size=\"md\"\u003eLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2230\" data-end=\"2269\"\u003e\n\u003ctd data-start=\"2230\" data-end=\"2252\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2232\" data-end=\"2251\"\u003eMemory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2252\" data-end=\"2269\" data-col-size=\"md\"\u003e200 Data Sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2270\" data-end=\"2314\"\u003e\n\u003ctd data-start=\"2270\" data-end=\"2294\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2272\" data-end=\"2293\"\u003eMeasurement Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2294\" data-end=\"2314\" data-col-size=\"md\"\u003emg, mg\/L, %, ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2315\" data-end=\"2343\"\u003e\n\u003ctd data-start=\"2315\" data-end=\"2336\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2317\" data-end=\"2335\"\u003eReset Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2336\" data-end=\"2343\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2344\" data-end=\"2384\"\u003e\n\u003ctd data-start=\"2344\" data-end=\"2374\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2346\" data-end=\"2373\"\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2374\" data-end=\"2384\" data-col-size=\"md\"\u003eRS232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2385\" data-end=\"2424\"\u003e\n\u003ctd data-start=\"2385\" data-end=\"2404\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2387\" data-end=\"2403\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2404\" data-end=\"2424\" data-col-size=\"md\"\u003eAC 220 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2425\" data-end=\"2476\"\u003e\n\u003ctd data-start=\"2425\" data-end=\"2454\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2427\" data-end=\"2453\"\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2454\" data-end=\"2476\" data-col-size=\"md\"\u003e540 × 500 × 480 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2477\" data-end=\"2507\"\u003e\n\u003ctd data-start=\"2477\" data-end=\"2496\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2479\" data-end=\"2495\"\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2496\" data-end=\"2507\" data-col-size=\"md\"\u003e12.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"relative h-0 self-end select-none\"\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cbutton aria-label=\"Copy table\" class=\"hover:bg-token-bg-tertiary text-token-text-secondary relative z-10 my-1 rounded-sm p-1 transition-opacity group-[:not(:hover):not(:focus-within)]:pointer-events-none group-[:not(:hover):not(:focus-within)]:opacity-0\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" class=\"icon\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-16f983c9.svg#ce3544\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2509\" data-end=\"2512\"\u003e\n\u003ch2 data-section-id=\"fxuij2\" data-start=\"2514\" data-end=\"2539\"\u003eStandard Configuration\u003c\/h2\u003e\n\u003cul data-start=\"2541\" data-end=\"2799\"\u003e\n\u003cli data-section-id=\"1gvkwc\" data-start=\"2541\" data-end=\"2594\"\u003e\n\u003cp data-start=\"2543\" data-end=\"2594\"\u003eIntegrated Volumetric Karl Fischer Titration System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"flcypi\" data-start=\"2595\" data-end=\"2649\"\u003e\n\u003cp data-start=\"2597\" data-end=\"2649\"\u003eIntegrated Coulometric Karl Fischer Titration System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xqtbhu\" data-start=\"2650\" data-end=\"2725\"\u003e\n\u003cp data-start=\"2652\" data-end=\"2725\"\u003eCoulometric Electrolytic Cell with Diaphragm (for trace moisture samples)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17n3lr7\" data-start=\"2726\" data-end=\"2799\"\u003e\n\u003cp data-start=\"2728\" data-end=\"2799\"\u003eVolumetric Sample Titration Unit (for constant\/higher moisture samples)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":53318290833705,"sku":"KFT250VC","price":469000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/labman-kft250vc-karl-fischer-titrator.jpg?v=1783492379","url":"https:\/\/www.labmart.in\/products\/automatic-karl-fischer-titrator-kft250vc","provider":"Labmart.in","version":"1.0","type":"link"}