You need to choose options for product.
-
files/qt_q_60jpg.jpg
SALIENT FEATURES
Models
-
AAS4M – 4 Lamps Option
-
AAS8A – 8 Lamps Option
Flame System
-
AAS4M – Flame, Fuel Gas C₂H₂ (Acetylene + Air)
-
AAS8A – Flame & Graphite Furnace (Auto sampler and RCB can be attached – Optional)
Gas Requirements
-
Graphite Furnace requires Argon (Ar) gas
Gas Control
-
Automatic control and optimization (flow/pressure)
Lamps
-
Hollow Cathode Lamp – Copper (Cu) supplied as standard
-
Other lamps available as optional accessories
Software
-
Standard software supplied with the instrument
-
Computer not included with the instrument
-
User must connect their own computer
ESSENTIAL ACCESSORIES (ADDITIONAL COST)
-
Air Compressor (Oil Free) – ACOF30
-
Graphite Furnace – GF3000
-
Auto Sampler for Graphite Furnace – ASG85
-
Refrigerated Circulating Bath – RCB
Hollow Cathode Lamps Available
-
Copper (Cu)
-
Zinc (Zn)
-
Iron (Fe)
-
Manganese (Mn)
-
Lead (Pb)
-
Magnesium (Mg)
-
Nickel (Ni)
-
Cadmium (Cd)
-
Calcium (Ca)
-
Chromium (Cr)
-
Lithium (Li)
-
Cobalt (Co)
ABOUT ATOMIC ABSORPTION SPECTROPHOTOMETER
Atomic Absorption Spectrophotometer is an analytical instrument used to quantitatively determine metal elements in a sample by measuring the absorption of light by free atoms.
When a sample is heated (flame or graphite furnace), the metal atoms absorb light at element-specific wavelengths. The amount of light absorbed is directly proportional to the concentration of that element in the sample.
AAS is widely used in laboratories for elemental analysis, especially in:
-
Research & Development laboratories
-
Educational institutions
-
Analytical laboratories
| Parameter | AAS4M | AAS8A |
|---|---|---|
| Operation Setting | Manual / Automatic | Manual / Automatic |
| Lamp Socket Options | 4 Lamps | 8 Lamps |
| Make | LABMAN | LABMAN |
| Wavelength Range | 190 – 900 nm | 190 – 900 nm |
| Scintillation Wavelength | 250 nm | 250 nm |
| Grating System | 1800 line/mm | 1800 line/mm |
| Wavelength Repeatability | ±0.1 nm | ±0.1 nm |
| Wavelength Accuracy | ±0.2 nm | ±0.2 nm |
| Optical System | Czerny-Turner integrated optical bench | Same |
| Spectral Bandwidth | 0.2 nm | 0.2 nm |
| Slit | 6-gear automatic switching | Same |
| Photometric Range | 0–125%, −0.1–3.00 A | Same |
| Baseline Drift | ≤0.002 ABS / 30 min | Same |
| Background Correction | BGC-SR / BGC-D2 | Same |
| Combustion Head | Air-Acetylene flame | Same |
| Sprayer | High efficiency glass sprayer | Same |
| Ignition Baseline Drift | ≤0.004 ABS / 30 min | Same |
| Characteristic Concentration (Cu) | 0.025 µg/ml / 1% | Same |
| Detection Limit (Cu) | ≤0.008 µg/ml | ≤0.004 µg/ml |
| Measurement Repeatability | RSD < 0.5% | RSD < 0.5% |
| Ambient Temperature | 10–30°C | 10–30°C |
| Standard Lamp | Copper | Copper |
| Software | Available | Available |
| Power Supply | AC 220V / 50–60Hz | Same |
| Machine Dimensions | 710 × 560 × 420 mm | Same |
| Net Weight | 62 kg | 58 kg |
| Gross Weight | 96 kg | 93 kg |
| Packing Type | Wooden packing | Wooden packing |
ACCESSORIES SPECIFICATIONS
Air Compressor (Oil Free) – ACOF30
| Parameter | Specification |
|---|---|
| Tank Capacity | 30 L |
| Flow Rate | 80 L/min |
| Noise Level | 56 dB |
| Speed | 1400 rpm |
| High Pressure | 0.8 MPa (100 PSI) |
| Power | 550 W |
| Machine Dimensions | 390 × 390 × 590 mm |
| Packing Dimensions | 460 × 460 × 640 mm |
| Net Weight | 24 kg |
| Gross Weight | 31 kg |
Graphite Furnace – GF3000
| Parameter | Specification |
|---|---|
| Temperature Range | Up to 3000°C |
| Characteristic Mass | Cd ≤ 1 pg, Cu ≤ 10 pg |
| Relative Standard Deviation | Cd ≤ 3%, Cu ≤ 3% |
| Heating Mode | Longitudinal Heating |
| Internal Gas Flow Rate | Automatic adjustment |
| Operation | Windows based software |
| Machine Dimensions | 280 × 500 × 430 mm |
| Packing Dimensions | 745 × 640 × 725 mm |
| Net Weight | 56 kg |
| Gross Weight | 88 kg |
Auto Sampler – ASG85
| Parameter | Specification |
|---|---|
| Sample Position Capacity | 85 |
| Calibration Curve | Automatic |
| Dilution Function | Automatic dilution |
| Operation | Windows based software |
| Rinse Solution Bottle | Available |
| Communication Port | USB & RS232C |
| Machine Dimensions | 305 × 205 × 165 mm |
| Packing Dimensions | 455 × 405 × 350 mm |
| Net Weight | 6 kg |
| Gross Weight | 8 kg |
OTHER LABMAN PRODUCTS (2026)
Examples from the product range:
-
Blue Light Transilluminator
-
Infrared Sterilizer
-
Automatic ELISA Plate Washer
-
pH Meters
-
HPLC
-
Gas Chromatography
-
Microwave Digestion System
-
Spectrophotometers
-
Turbidity Meter
-
Freeze Dryer
-
Karl Fischer Titrator
-
Rotary Evaporator
-
Conductivity Meter
-
Atomic Absorption Spectrophotometer
-
Graphite Furnace
-
CO₂ Incubator
-
Magnetic Stirrers
- Regular price
- Rs.0.00
SALIENT FEATURES
Models
-
AAS4M – 4 Lamps Option
-
AAS8A – 8 Lamps Option
Flame System
-
AAS4M – Flame, Fuel Gas C₂H₂ (Acetylene + Air)
-
AAS8A – Flame & Graphite Furnace (Auto sampler and RCB can be attached – Optional)
Gas Requirements
-
Graphite Furnace requires Argon (Ar) gas
Gas Control
-
Automatic control and optimization (flow/pressure)
Lamps
-
Hollow Cathode Lamp – Copper (Cu) supplied as standard
-
Other lamps available as optional accessories
Software
-
Standard software supplied with the instrument
-
Computer not included with the instrument
-
User must connect their own computer
ESSENTIAL ACCESSORIES (ADDITIONAL COST)
-
Air Compressor (Oil Free) – ACOF30
-
Graphite Furnace – GF3000
-
Auto Sampler for Graphite Furnace – ASG85
-
Refrigerated Circulating Bath – RCB
Hollow Cathode Lamps Available
-
Copper (Cu)
-
Zinc (Zn)
-
Iron (Fe)
-
Manganese (Mn)
-
Lead (Pb)
-
Magnesium (Mg)
-
Nickel (Ni)
-
Cadmium (Cd)
-
Calcium (Ca)
-
Chromium (Cr)
-
Lithium (Li)
-
Cobalt (Co)
ABOUT ATOMIC ABSORPTION SPECTROPHOTOMETER
Atomic Absorption Spectrophotometer is an analytical instrument used to quantitatively determine metal elements in a sample by measuring the absorption of light by free atoms.
When a sample is heated (flame or graphite furnace), the metal atoms absorb light at element-specific wavelengths. The amount of light absorbed is directly proportional to the concentration of that element in the sample.
AAS is widely used in laboratories for elemental analysis, especially in:
-
Research & Development laboratories
-
Educational institutions
-
Analytical laboratories
| Parameter | AAS4M | AAS8A |
|---|---|---|
| Operation Setting | Manual / Automatic | Manual / Automatic |
| Lamp Socket Options | 4 Lamps | 8 Lamps |
| Make | LABMAN | LABMAN |
| Wavelength Range | 190 – 900 nm | 190 – 900 nm |
| Scintillation Wavelength | 250 nm | 250 nm |
| Grating System | 1800 line/mm | 1800 line/mm |
| Wavelength Repeatability | ±0.1 nm | ±0.1 nm |
| Wavelength Accuracy | ±0.2 nm | ±0.2 nm |
| Optical System | Czerny-Turner integrated optical bench | Same |
| Spectral Bandwidth | 0.2 nm | 0.2 nm |
| Slit | 6-gear automatic switching | Same |
| Photometric Range | 0–125%, −0.1–3.00 A | Same |
| Baseline Drift | ≤0.002 ABS / 30 min | Same |
| Background Correction | BGC-SR / BGC-D2 | Same |
| Combustion Head | Air-Acetylene flame | Same |
| Sprayer | High efficiency glass sprayer | Same |
| Ignition Baseline Drift | ≤0.004 ABS / 30 min | Same |
| Characteristic Concentration (Cu) | 0.025 µg/ml / 1% | Same |
| Detection Limit (Cu) | ≤0.008 µg/ml | ≤0.004 µg/ml |
| Measurement Repeatability | RSD < 0.5% | RSD < 0.5% |
| Ambient Temperature | 10–30°C | 10–30°C |
| Standard Lamp | Copper | Copper |
| Software | Available | Available |
| Power Supply | AC 220V / 50–60Hz | Same |
| Machine Dimensions | 710 × 560 × 420 mm | Same |
| Net Weight | 62 kg | 58 kg |
| Gross Weight | 96 kg | 93 kg |
| Packing Type | Wooden packing | Wooden packing |
ACCESSORIES SPECIFICATIONS
Air Compressor (Oil Free) – ACOF30
| Parameter | Specification |
|---|---|
| Tank Capacity | 30 L |
| Flow Rate | 80 L/min |
| Noise Level | 56 dB |
| Speed | 1400 rpm |
| High Pressure | 0.8 MPa (100 PSI) |
| Power | 550 W |
| Machine Dimensions | 390 × 390 × 590 mm |
| Packing Dimensions | 460 × 460 × 640 mm |
| Net Weight | 24 kg |
| Gross Weight | 31 kg |
Graphite Furnace – GF3000
| Parameter | Specification |
|---|---|
| Temperature Range | Up to 3000°C |
| Characteristic Mass | Cd ≤ 1 pg, Cu ≤ 10 pg |
| Relative Standard Deviation | Cd ≤ 3%, Cu ≤ 3% |
| Heating Mode | Longitudinal Heating |
| Internal Gas Flow Rate | Automatic adjustment |
| Operation | Windows based software |
| Machine Dimensions | 280 × 500 × 430 mm |
| Packing Dimensions | 745 × 640 × 725 mm |
| Net Weight | 56 kg |
| Gross Weight | 88 kg |
Auto Sampler – ASG85
| Parameter | Specification |
|---|---|
| Sample Position Capacity | 85 |
| Calibration Curve | Automatic |
| Dilution Function | Automatic dilution |
| Operation | Windows based software |
| Rinse Solution Bottle | Available |
| Communication Port | USB & RS232C |
| Machine Dimensions | 305 × 205 × 165 mm |
| Packing Dimensions | 455 × 405 × 350 mm |
| Net Weight | 6 kg |
| Gross Weight | 8 kg |
OTHER LABMAN PRODUCTS (2026)
Examples from the product range:
-
Blue Light Transilluminator
-
Infrared Sterilizer
-
Automatic ELISA Plate Washer
-
pH Meters
-
HPLC
-
Gas Chromatography
-
Microwave Digestion System
-
Spectrophotometers
-
Turbidity Meter
-
Freeze Dryer
-
Karl Fischer Titrator
-
Rotary Evaporator
-
Conductivity Meter
-
Atomic Absorption Spectrophotometer
-
Graphite Furnace
-
CO₂ Incubator
-
Magnetic Stirrers
- Regular price
- Rs.0.00
Couldn't load pickup availability
- Delivery Period :5-7 Working Days
- Replacement :3 Days Replacement as standard, Free of Cost
- Dedicated Support :Support from 9:30 AM to 6:00 PM everyday
Product Description
SALIENT FEATURES
Models
-
AAS4M – 4 Lamps Option
-
AAS8A – 8 Lamps Option
Flame System
-
AAS4M – Flame, Fuel Gas C₂H₂ (Acetylene + Air)
-
AAS8A – Flame & Graphite Furnace (Auto sampler and RCB can be attached – Optional)
Gas Requirements
-
Graphite Furnace requires Argon (Ar) gas
Gas Control
-
Automatic control and optimization (flow/pressure)
Lamps
-
Hollow Cathode Lamp – Copper (Cu) supplied as standard
-
Other lamps available as optional accessories
Software
-
Standard software supplied with the instrument
-
Computer not included with the instrument
-
User must connect their own computer
ESSENTIAL ACCESSORIES (ADDITIONAL COST)
-
Air Compressor (Oil Free) – ACOF30
-
Graphite Furnace – GF3000
-
Auto Sampler for Graphite Furnace – ASG85
-
Refrigerated Circulating Bath – RCB
Hollow Cathode Lamps Available
-
Copper (Cu)
-
Zinc (Zn)
-
Iron (Fe)
-
Manganese (Mn)
-
Lead (Pb)
-
Magnesium (Mg)
-
Nickel (Ni)
-
Cadmium (Cd)
-
Calcium (Ca)
-
Chromium (Cr)
-
Lithium (Li)
-
Cobalt (Co)
ABOUT ATOMIC ABSORPTION SPECTROPHOTOMETER
Atomic Absorption Spectrophotometer is an analytical instrument used to quantitatively determine metal elements in a sample by measuring the absorption of light by free atoms.
When a sample is heated (flame or graphite furnace), the metal atoms absorb light at element-specific wavelengths. The amount of light absorbed is directly proportional to the concentration of that element in the sample.
AAS is widely used in laboratories for elemental analysis, especially in:
-
Research & Development laboratories
-
Educational institutions
-
Analytical laboratories
| Parameter | AAS4M | AAS8A |
|---|---|---|
| Operation Setting | Manual / Automatic | Manual / Automatic |
| Lamp Socket Options | 4 Lamps | 8 Lamps |
| Make | LABMAN | LABMAN |
| Wavelength Range | 190 – 900 nm | 190 – 900 nm |
| Scintillation Wavelength | 250 nm | 250 nm |
| Grating System | 1800 line/mm | 1800 line/mm |
| Wavelength Repeatability | ±0.1 nm | ±0.1 nm |
| Wavelength Accuracy | ±0.2 nm | ±0.2 nm |
| Optical System | Czerny-Turner integrated optical bench | Same |
| Spectral Bandwidth | 0.2 nm | 0.2 nm |
| Slit | 6-gear automatic switching | Same |
| Photometric Range | 0–125%, −0.1–3.00 A | Same |
| Baseline Drift | ≤0.002 ABS / 30 min | Same |
| Background Correction | BGC-SR / BGC-D2 | Same |
| Combustion Head | Air-Acetylene flame | Same |
| Sprayer | High efficiency glass sprayer | Same |
| Ignition Baseline Drift | ≤0.004 ABS / 30 min | Same |
| Characteristic Concentration (Cu) | 0.025 µg/ml / 1% | Same |
| Detection Limit (Cu) | ≤0.008 µg/ml | ≤0.004 µg/ml |
| Measurement Repeatability | RSD < 0.5% | RSD < 0.5% |
| Ambient Temperature | 10–30°C | 10–30°C |
| Standard Lamp | Copper | Copper |
| Software | Available | Available |
| Power Supply | AC 220V / 50–60Hz | Same |
| Machine Dimensions | 710 × 560 × 420 mm | Same |
| Net Weight | 62 kg | 58 kg |
| Gross Weight | 96 kg | 93 kg |
| Packing Type | Wooden packing | Wooden packing |
ACCESSORIES SPECIFICATIONS
Air Compressor (Oil Free) – ACOF30
| Parameter | Specification |
|---|---|
| Tank Capacity | 30 L |
| Flow Rate | 80 L/min |
| Noise Level | 56 dB |
| Speed | 1400 rpm |
| High Pressure | 0.8 MPa (100 PSI) |
| Power | 550 W |
| Machine Dimensions | 390 × 390 × 590 mm |
| Packing Dimensions | 460 × 460 × 640 mm |
| Net Weight | 24 kg |
| Gross Weight | 31 kg |
Graphite Furnace – GF3000
| Parameter | Specification |
|---|---|
| Temperature Range | Up to 3000°C |
| Characteristic Mass | Cd ≤ 1 pg, Cu ≤ 10 pg |
| Relative Standard Deviation | Cd ≤ 3%, Cu ≤ 3% |
| Heating Mode | Longitudinal Heating |
| Internal Gas Flow Rate | Automatic adjustment |
| Operation | Windows based software |
| Machine Dimensions | 280 × 500 × 430 mm |
| Packing Dimensions | 745 × 640 × 725 mm |
| Net Weight | 56 kg |
| Gross Weight | 88 kg |
Auto Sampler – ASG85
| Parameter | Specification |
|---|---|
| Sample Position Capacity | 85 |
| Calibration Curve | Automatic |
| Dilution Function | Automatic dilution |
| Operation | Windows based software |
| Rinse Solution Bottle | Available |
| Communication Port | USB & RS232C |
| Machine Dimensions | 305 × 205 × 165 mm |
| Packing Dimensions | 455 × 405 × 350 mm |
| Net Weight | 6 kg |
| Gross Weight | 8 kg |
OTHER LABMAN PRODUCTS (2026)
Examples from the product range:
-
Blue Light Transilluminator
-
Infrared Sterilizer
-
Automatic ELISA Plate Washer
-
pH Meters
-
HPLC
-
Gas Chromatography
-
Microwave Digestion System
-
Spectrophotometers
-
Turbidity Meter
-
Freeze Dryer
-
Karl Fischer Titrator
-
Rotary Evaporator
-
Conductivity Meter
-
Atomic Absorption Spectrophotometer
-
Graphite Furnace
-
CO₂ Incubator
-
Magnetic Stirrers
Similar Products
-
Vendor: Labman
HPLC I Liquid chromatography I Isocratic System
No reviewsRegular price Rs.0.00 -
Vendor: Labman
Graphite Furnace for AAS
No reviewsRegular price Rs.0.00 -
Vendor: Labman
Auto Sampler for Graphite Furnace
No reviewsRegular price Rs.0.00 -
Vendor: Labman
Air Compressor (Oil Free)
No reviewsRegular price Rs.0.00
-
Free Shipping
Orders above Rs. 1000.
-
On Time Delivery
Within 7 days.
-
Money Back Guarantee
14 day Return*
-
Service Support
Online Installation Support.