{"product_id":"asgc22-gas-chromatography-autosampler","title":"ASGC22 Gas Chromatography Autosampler – Automatic GC Sample Injector","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eLabmart ASGC22 Autosampler for Gas Chromatography\u003c\/strong\u003e is an automated sample injection system designed to improve the efficiency, precision and reproducibility of GC analysis. It features a \u003cstrong\u003e5-inch interactive touch interface, 22-position sample tray, programmable injection parameters, multiple injection modes and GC software control\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 dir=\"auto\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 dir=\"auto\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eASGC22 Autosampler for Gas Chromatography\u003c\/strong\u003e is designed to automatically inject samples into a gas chromatography instrument, reducing manual intervention and supporting consistent sample handling.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue describes the ASGC22 as a compact, lightweight and highly universal autosampler with a \u003cstrong\u003e5-inch visual man-machine interactive touch interface\u003c\/strong\u003e. Its powered injection mechanism is designed to provide stable injection speed and accurate injection volume.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system supports \u003cstrong\u003e22 sample positions, 19 sample vials, 2 solvent vials and 1 waste vial\u003c\/strong\u003e. It allows programmable sample injection times, multiple analytical methods and adjustable needle and sample extraction\/injection speeds.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe ASGC22 also supports \u003cstrong\u003ebarcode scanning, sample temperature control, multiple I\/O connection modes and PC\/GC software control\u003c\/strong\u003e, making it suitable for automated GC workflows.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e5-inch visual man-machine interactive touch interface\u003c\/li\u003e\n\u003cli\u003e22-digit sample tray\u003c\/li\u003e\n\u003cli\u003e19 sample vial positions\u003c\/li\u003e\n\u003cli\u003e2 solvent vial positions\u003c\/li\u003e\n\u003cli\u003e1 waste vial position\u003c\/li\u003e\n\u003cli\u003eInjector sizes from \u003cstrong\u003e1 to 500 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSample injection times programmable from \u003cstrong\u003e1 to 99 times\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eUp to \u003cstrong\u003e20 methods\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum interval of \u003cstrong\u003e999 minutes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMinimum sample size of \u003cstrong\u003e0.1 µl\u003c\/strong\u003e using a 1 µl syringe\u003c\/li\u003e\n\u003cli\u003eMaximum sample size of \u003cstrong\u003e250 µl\u003c\/strong\u003e using a 500 µl syringe\u003c\/li\u003e\n\u003cli\u003eFast, slow and user-defined needle speed\u003c\/li\u003e\n\u003cli\u003eFast, slow and user-defined sample extraction\/injection speed\u003c\/li\u003e\n\u003cli\u003eNormal and continuous injection modes\u003c\/li\u003e\n\u003cli\u003eGC software control\u003c\/li\u003e\n\u003cli\u003eBarcode scanning support\u003c\/li\u003e\n\u003cli\u003eSample temperature control function\u003c\/li\u003e\n\u003cli\u003eMultiple I\/O port modes for connection with different kinds of GC\u003c\/li\u003e\n\u003cli\u003ePC control capability\u003c\/li\u003e\n\u003cli\u003eIntelligent step-by-step order entry with prompts\u003c\/li\u003e\n\u003cli\u003eSynchronous sampling time reproducibility of less than \u003cstrong\u003e1\/1000 s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e24-hour uninterrupted automated operation capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue specifically highlights increased productivity through automated sample injection and improved accuracy through precise and consistent injection volumes. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 dir=\"auto\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eASGC22 Catalogue Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eAutosampler for Gas Chromatography\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASGC22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake in Catalogue\u003c\/td\u003e\n\u003ctd\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSN Code\u003c\/td\u003e\n\u003ctd\u003e90272000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjector Size\u003c\/td\u003e\n\u003ctd\u003e1, 5, 10, 25, 50, 100, 250, 500 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Tray\u003c\/td\u003e\n\u003ctd\u003e22-digit sample tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Vial Capacity\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolvent Vial Capacity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaste Vial Capacity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Injection Times of Each Line\u003c\/td\u003e\n\u003ctd\u003e1 to 99 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Interval\u003c\/td\u003e\n\u003ctd\u003e999 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Sample Size\u003c\/td\u003e\n\u003ctd\u003e0.1 µl using 1 µl syringe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Sample Size\u003c\/td\u003e\n\u003ctd\u003e250 µl using 500 µl syringe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e1 to 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Injection Inlet\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Needle Cleaning Times\u003c\/td\u003e\n\u003ctd\u003e99 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Sample Pumping Times\u003c\/td\u003e\n\u003ctd\u003e99 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Sample Pumping Interval\u003c\/td\u003e\n\u003ctd\u003e5000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViscosity Delay\u003c\/td\u003e\n\u003ctd\u003e0–60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDwell Time Before \u0026amp; After Injection\u003c\/td\u003e\n\u003ctd\u003e0–120 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle Speed\u003c\/td\u003e\n\u003ctd\u003eFast, Slow, User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Extraction \u0026amp; Injection Speed\u003c\/td\u003e\n\u003ctd\u003eFast, Slow, User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Mode\u003c\/td\u003e\n\u003ctd\u003eNormal Mode, Continuity Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Mode\u003c\/td\u003e\n\u003ctd\u003eGC Software Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Dimension (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e620 × 325 × 280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd\u003eMain Instrument, Power Cord, Instruction Manual, Test Certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eThese specifications are taken from the ASGC22 specification table in the supplied 2025–26 catalogue. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 dir=\"auto\"\u003e5. Applications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated sample injection for gas chromatography\u003c\/li\u003e\n\u003cli\u003ePharmaceutical GC analysis\u003c\/li\u003e\n\u003cli\u003eChemical analysis\u003c\/li\u003e\n\u003cli\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli\u003eResearch laboratories\u003c\/li\u003e\n\u003cli\u003eRoutine GC sample processing\u003c\/li\u003e\n\u003cli\u003eAutomated analysis of multiple samples\u003c\/li\u003e\n\u003cli\u003eApplications requiring consistent injection volumes\u003c\/li\u003e\n\u003cli\u003eApplications requiring unattended GC operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 dir=\"auto\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eGas chromatography laboratories\u003c\/li\u003e\n\u003cli\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli\u003eChemical testing laboratories\u003c\/li\u003e\n\u003cli\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli\u003eResearch and development laboratories\u003c\/li\u003e\n\u003cli\u003eAnalytical testing laboratories\u003c\/li\u003e\n\u003cli\u003eLaboratories performing repetitive GC sample analysis\u003c\/li\u003e\n\u003cli\u003eLaboratories seeking automated sample injection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 dir=\"auto\"\u003e1. What is the ASGC22?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eASGC22 is an \u003cstrong\u003eAutosampler for Gas Chromatography\u003c\/strong\u003e designed to automatically inject samples into a GC instrument.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e2. How many samples can the sample tray hold?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe ASGC22 has a \u003cstrong\u003e22-digit sample tray\u003c\/strong\u003e and supports \u003cstrong\u003e19 sample vials\u003c\/strong\u003e according to the catalogue.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e3. How many solvent vials are supported?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system supports \u003cstrong\u003e2 solvent vials\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e4. Is there a waste vial position?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. The specification table provides \u003cstrong\u003e1 waste vial\u003c\/strong\u003e position.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e5. What injector sizes are available?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue specifies injector sizes of \u003cstrong\u003e1, 5, 10, 25, 50, 100, 250 and 500 µl\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e6. What is the minimum sample size?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe minimum specified sample size is \u003cstrong\u003e0.1 µl when using a 1 µl syringe\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e7. What is the maximum sample size?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe maximum specified sample size is \u003cstrong\u003e250 µl when using a 500 µl syringe\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e8. How many methods can be programmed?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe ASGC22 supports \u003cstrong\u003e1 to 20 methods\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e9. Can the injection speed be adjusted?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. Needle speed and sample extraction\/injection speed can each be set to \u003cstrong\u003eFast, Slow or User-defined\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e10. Does the ASGC22 support continuous injection?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. The catalogue specifies \u003cstrong\u003eNormal Mode and Continuity Mode\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e11. Can the autosampler be controlled through GC software?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. The specified control mode is \u003cstrong\u003eGC Software Control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e12. Does it support barcode scanning?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. The catalogue specifically lists \u003cstrong\u003ebarcode scanning support\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e13. Can the system operate without continuous operator intervention?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue describes a high degree of automation and states that the system can support \u003cstrong\u003e24 hours of uninterrupted work without a person\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e14. What is the power requirement?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe specified power supply is \u003cstrong\u003eAC 220V \/ 50–60Hz\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":67542029369641,"sku":"ASGC22","price":472699.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/ChatGPTImageSep26_2026_12_59_09PM_1.png?v=1790407767","url":"https:\/\/www.labmart.in\/products\/asgc22-gas-chromatography-autosampler","provider":"Labmart.in","version":"1.0","type":"link"}