{"product_id":"afc100-automatic-fraction-collector","title":"AFC100 Automatic Fraction Collector – 100-Tube Chromatography Fraction Collector","description":"\u003cp dir=\"auto\" data-start=\"138\" data-end=\"497\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"142\" data-end=\"189\"\u003eLabmart AFC100 Automatic Fraction Collector\u003c\/strong\u003e is a microcontroller-based laboratory instrument designed to automate liquid-phase fraction collection during chromatographic analysis. It uses a reliable round-turntable carousel to collect separated fractions into individual vessels, reducing manual handling and supporting efficient laboratory workflows.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"534\" data-end=\"553\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"555\" data-end=\"834\"\u003eThe \u003cstrong data-start=\"559\" data-end=\"598\"\u003eAFC100 Automatic Fraction Collector\u003c\/strong\u003e is designed to streamline sample collection during chromatographic analysis. It automates the collection of liquid-phase components into individual collection vessels, helping reduce manual handling and the risk of cross-contamination.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"836\" data-end=\"998\"\u003eThe system features a \u003cstrong data-start=\"858\" data-end=\"886\"\u003eround turntable carousel\u003c\/strong\u003e with capacity for \u003cstrong data-start=\"905\" data-end=\"918\"\u003e100 tubes\u003c\/strong\u003e, making it suitable for sequential fraction collection in laboratory workflows.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1000\" data-end=\"1170\"\u003eThe AFC100 is described in the supplied catalogue as an advanced, microcontroller-based system particularly suitable for applications including \u003cstrong data-start=\"1144\" data-end=\"1169\"\u003ebiochemistry research\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"5m7ztm\" dir=\"auto\" data-start=\"1172\" data-end=\"1200\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3 data-section-id=\"164obq9\" dir=\"auto\" data-start=\"1202\" data-end=\"1233\"\u003ePrecise Fraction Collection\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1235\" data-end=\"1391\"\u003eThe AFC100 is designed for programmable fraction collection based on \u003cstrong data-start=\"1304\" data-end=\"1339\"\u003etime intervals or drop counting\u003c\/strong\u003e, helping provide uniform collection across samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"itsoat\" dir=\"auto\" data-start=\"1393\" data-end=\"1424\"\u003eSmart Microcomputer Control\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1426\" data-end=\"1553\"\u003eAn intuitive \u003cstrong data-start=\"1439\" data-end=\"1466\"\u003edigital LCD\/LED display\u003c\/strong\u003e is managed by a microcomputer control system for stable and straightforward operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1x2dr9k\" dir=\"auto\" data-start=\"1555\" data-end=\"1576\"\u003e100-Tube Capacity\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1578\" data-end=\"1686\"\u003eThe round carousel accommodates \u003cstrong data-start=\"1610\" data-end=\"1634\"\u003e100 collection tubes\u003c\/strong\u003e, supporting extended fraction-collection sequences.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1tsugvg\" dir=\"auto\" data-start=\"1688\" data-end=\"1705\"\u003eDrop Counting\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1707\" data-end=\"1782\"\u003eThe system provides a specified drop-counting range of \u003cstrong data-start=\"1762\" data-end=\"1781\"\u003e1 to 9999 drops\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1x51imd\" dir=\"auto\" data-start=\"1784\" data-end=\"1812\"\u003eExtended Timed Operation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1814\" data-end=\"1950\"\u003eThe specified timed range is \u003cstrong data-start=\"1843\" data-end=\"1867\"\u003e1 second to 24 hours\u003c\/strong\u003e, allowing fraction collection to be configured for different analytical workflows.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ne2ri6\" dir=\"auto\" data-start=\"1952\" data-end=\"1976\"\u003eContinuous Operation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1978\" data-end=\"2144\"\u003eThe catalogue states that the AFC100 can operate continuously for \u003cstrong data-start=\"2044\" data-end=\"2065\"\u003eup to a full week\u003c\/strong\u003e without drop-loss or manual resets, supporting high-throughput laboratory use.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11do8uq\" dir=\"auto\" data-start=\"2146\" data-end=\"2170\"\u003eDurable Construction\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2172\" data-end=\"2241\"\u003eThe unit uses \u003cstrong data-start=\"2186\" data-end=\"2217\"\u003ehigh-durability ABS plastic\u003c\/strong\u003e for its material build.\u003c\/p\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2243\" data-end=\"2272\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2274\" data-end=\"2810\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2274\" data-end=\"2324\"\u003e\n\u003ctr data-start=\"2274\" data-end=\"2324\"\u003e\n\u003cth data-start=\"2274\" data-end=\"2290\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2290\" data-end=\"2324\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eAFC100 Catalogue Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2335\" data-end=\"2810\"\u003e\n\u003ctr data-start=\"2335\" data-end=\"2382\"\u003e\n\u003ctd data-start=\"2335\" data-end=\"2350\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"2350\" data-end=\"2382\" data-col-size=\"sm\"\u003eAutomatic Fraction Collector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2383\" data-end=\"2401\"\u003e\n\u003ctd data-start=\"2383\" data-end=\"2391\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2391\" data-end=\"2401\" data-col-size=\"sm\"\u003eAFC100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2402\" data-end=\"2449\"\u003e\n\u003ctd data-start=\"2402\" data-end=\"2417\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2417\" data-end=\"2449\" data-col-size=\"sm\"\u003eAutomatic Fraction Collector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2450\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2450\" data-end=\"2474\" data-col-size=\"sm\"\u003eMaximum Tube Capacity\u003c\/td\u003e\n\u003ctd data-start=\"2474\" data-end=\"2492\" data-col-size=\"sm\"\u003e12 ml to 15 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2522\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2509\" data-col-size=\"sm\"\u003eTube Quantity\u003c\/td\u003e\n\u003ctd data-start=\"2509\" data-end=\"2522\" data-col-size=\"sm\"\u003e100 Tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2523\" data-end=\"2558\"\u003e\n\u003ctd data-start=\"2523\" data-end=\"2541\" data-col-size=\"sm\"\u003eCollection Mode\u003c\/td\u003e\n\u003ctd data-start=\"2541\" data-end=\"2558\" data-col-size=\"sm\"\u003eDrop Counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2559\" data-end=\"2594\"\u003e\n\u003ctd data-start=\"2559\" data-end=\"2573\" data-col-size=\"sm\"\u003eTimed Range\u003c\/td\u003e\n\u003ctd data-start=\"2573\" data-end=\"2594\" data-col-size=\"sm\"\u003e1 second to 24 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2595\" data-end=\"2641\"\u003e\n\u003ctd data-start=\"2595\" data-end=\"2617\" data-col-size=\"sm\"\u003eDrop Counting Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2617\" data-end=\"2641\"\u003e1 drop to 9999 drops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2642\" data-end=\"2686\"\u003e\n\u003ctd data-start=\"2642\" data-end=\"2657\" data-col-size=\"sm\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd data-start=\"2657\" data-end=\"2686\" data-col-size=\"sm\"\u003eDigital Display (LCD\/LED)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2687\" data-end=\"2735\"\u003e\n\u003ctd data-start=\"2687\" data-end=\"2704\" data-col-size=\"sm\"\u003eMaterial Build\u003c\/td\u003e\n\u003ctd data-start=\"2704\" data-end=\"2735\" data-col-size=\"sm\"\u003eHigh-durability ABS Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2736\" data-end=\"2762\"\u003e\n\u003ctd data-start=\"2736\" data-end=\"2751\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2751\" data-end=\"2762\" data-col-size=\"sm\"\u003eAC 220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2763\" data-end=\"2810\"\u003e\n\u003ctd data-start=\"2763\" data-end=\"2785\" data-col-size=\"sm\"\u003eWorking Environment\u003c\/td\u003e\n\u003ctd data-start=\"2785\" data-end=\"2810\" data-col-size=\"sm\"\u003eTemperature: 4°C–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"2812\" data-end=\"3067\"\u003eThe catalogue's feature description also states that fraction collection can be automated based on \u003cstrong data-start=\"2911\" data-end=\"2945\"\u003eTime Interval or Drop Counting\u003c\/strong\u003e. The specification table separately lists \u003cstrong data-start=\"2988\" data-end=\"3005\"\u003eDrop Counting\u003c\/strong\u003e under Collection Modes. \u003cspan class=\"contents\" data-content-reference-start=\"3030\" data-content-reference-end=\"3060\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3069\" data-end=\"3086\"\u003e5. Applications\u003c\/h1\u003e\n\u003cul data-start=\"3088\" data-end=\"3389\"\u003e\n\u003cli data-section-id=\"hncf6b\" data-start=\"3088\" data-end=\"3125\"\u003eChromatographic fraction collection\u003c\/li\u003e\n\u003cli data-section-id=\"95a5cv\" data-start=\"3126\" data-end=\"3161\"\u003eLiquid-phase component collection\u003c\/li\u003e\n\u003cli data-section-id=\"lu3xbn\" data-start=\"3162\" data-end=\"3185\"\u003eBiochemistry research\u003c\/li\u003e\n\u003cli data-section-id=\"1grt933\" data-start=\"3186\" data-end=\"3223\"\u003eLaboratory chromatography workflows\u003c\/li\u003e\n\u003cli data-section-id=\"17aqkbo\" data-start=\"3224\" data-end=\"3262\"\u003eAutomated sample fraction collection\u003c\/li\u003e\n\u003cli data-section-id=\"ycyz5s\" data-start=\"3263\" data-end=\"3315\"\u003eSequential collection of chromatographic fractions\u003c\/li\u003e\n\u003cli data-section-id=\"1fc6wrf\" data-start=\"3316\" data-end=\"3350\"\u003eResearch laboratory applications\u003c\/li\u003e\n\u003cli data-section-id=\"13dswpu\" data-start=\"3351\" data-end=\"3389\"\u003eHigh-throughput laboratory workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3391\" data-end=\"3408\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cul data-start=\"3410\" data-end=\"3719\"\u003e\n\u003cli data-section-id=\"11tvf9y\" data-start=\"3410\" data-end=\"3446\"\u003eBiochemistry research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1bzru3d\" data-start=\"3447\" data-end=\"3476\"\u003eChromatography laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1f91tmb\" data-start=\"3477\" data-end=\"3515\"\u003ePharmaceutical research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"9f68h1\" data-start=\"3516\" data-end=\"3541\"\u003eAnalytical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ankfg0\" data-start=\"3542\" data-end=\"3574\"\u003eChemical research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1gsj3qb\" data-start=\"3575\" data-end=\"3625\"\u003eAcademic and institutional research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1o6vihb\" data-start=\"3626\" data-end=\"3680\"\u003eLaboratories requiring automated fraction collection\u003c\/li\u003e\n\u003cli data-section-id=\"1s3n0g9\" data-start=\"3681\" data-end=\"3719\"\u003eHigh-throughput analytical workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"5665\" data-end=\"5675\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"6uirqy\" dir=\"auto\" data-start=\"5677\" data-end=\"5703\"\u003e1. What is the AFC100?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5705\" data-end=\"5849\"\u003eThe AFC100 is an \u003cstrong data-start=\"5722\" data-end=\"5754\"\u003eAutomatic Fraction Collector\u003c\/strong\u003e designed to automate the collection of liquid-phase fractions during chromatographic analysis.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1aexoms\" dir=\"auto\" data-start=\"5851\" data-end=\"5893\"\u003e2. How many tubes can the AFC100 hold?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5895\" data-end=\"5938\"\u003eThe AFC100 has a capacity of \u003cstrong data-start=\"5924\" data-end=\"5937\"\u003e100 tubes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"va8ys\" dir=\"auto\" data-start=\"5940\" data-end=\"5979\"\u003e3. What tube capacity is specified?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5981\" data-end=\"6051\"\u003eThe catalogue specifies a maximum tube capacity of \u003cstrong data-start=\"6032\" data-end=\"6050\"\u003e12 ml to 15 ml\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"x7i2ji\" dir=\"auto\" data-start=\"6053\" data-end=\"6107\"\u003e4. What collection method does the AFC100 support?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6109\" data-end=\"6299\"\u003eThe specification table identifies \u003cstrong data-start=\"6144\" data-end=\"6161\"\u003eDrop Counting\u003c\/strong\u003e as the collection mode. The feature description also states that collection can be automated based on \u003cstrong data-start=\"6264\" data-end=\"6298\"\u003eTime Interval or Drop Counting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1umbr7p\" dir=\"auto\" data-start=\"6301\" data-end=\"6332\"\u003e5. What is the timed range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6334\" data-end=\"6388\"\u003eThe specified timed range is \u003cstrong data-start=\"6363\" data-end=\"6387\"\u003e1 second to 24 hours\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"et43dc\" dir=\"auto\" data-start=\"6390\" data-end=\"6429\"\u003e6. What is the drop-counting range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6431\" data-end=\"6492\"\u003eThe AFC100 has a specified range of \u003cstrong data-start=\"6467\" data-end=\"6491\"\u003e1 drop to 9999 drops\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t0skhc\" dir=\"auto\" data-start=\"6494\" data-end=\"6532\"\u003e7. Does the AFC100 have a display?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6534\" data-end=\"6595\"\u003eYes. The catalogue specifies a \u003cstrong data-start=\"6565\" data-end=\"6594\"\u003eDigital Display (LCD\/LED)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rlyi7o\" dir=\"auto\" data-start=\"6597\" data-end=\"6638\"\u003e8. What type of construction is used?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6640\" data-end=\"6704\"\u003eThe specified material build is \u003cstrong data-start=\"6672\" data-end=\"6703\"\u003ehigh-durability ABS plastic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"oe65ec\" dir=\"auto\" data-start=\"6706\" data-end=\"6755\"\u003e9. What power supply does the AFC100 require?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6757\" data-end=\"6793\"\u003eThe catalogue specifies \u003cstrong data-start=\"6781\" data-end=\"6792\"\u003eAC 220V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1prmm99\" dir=\"auto\" data-start=\"6795\" data-end=\"6841\"\u003e10. What is the working temperature range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6843\" data-end=\"6908\"\u003eThe specified working environment temperature is \u003cstrong data-start=\"6892\" data-end=\"6907\"\u003e4°C to 40°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"dz3kc9\" dir=\"auto\" data-start=\"6910\" data-end=\"6970\"\u003e11. Can the AFC100 be used for chromatographic analysis?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6972\" data-end=\"7069\"\u003eYes. It is specifically designed to automate fraction collection during chromatographic analysis.\u003c\/p\u003e\n\u003ch3 data-section-id=\"nf8dfp\" dir=\"auto\" data-start=\"7071\" data-end=\"7107\"\u003e12. Can it operate continuously?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7109\" data-end=\"7243\"\u003eThe catalogue states that the AFC100 is designed for continuous operation of \u003cstrong data-start=\"7186\" data-end=\"7242\"\u003eup to a full week without drop-loss or manual resets\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":67542054732073,"sku":"AFC100","price":156199.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/AFC100_Clean_White_Background.png?v=1790408574","url":"https:\/\/www.labmart.in\/products\/afc100-automatic-fraction-collector","provider":"Labmart.in","version":"1.0","type":"link"}