{"title":"Water Testing Meters","description":null,"products":[{"product_id":"hanna-hi98303-dist3-waterproof-low-range-ec-tester","title":"Hanna HI98303 DiST 3 Waterproof Low Range EC Tester, 0-2000 µS\/cm","description":"\u003cp\u003eThe Hanna HI98303 DiST 3 is a pocket-sized, waterproof low-range EC tester measuring up to 2000 µS\/cm, for drinking water, water conditioning, irrigation water and environmental monitoring in the lab or field.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMeasures up to 2000 µS\/cm\u003c\/li\u003e\n\u003cli\u003eWaterproof casing designed to float\u003c\/li\u003e\n\u003cli\u003eGraphite sensor that reduces polarization and does not oxidise\u003c\/li\u003e\n\u003cli\u003eAutomatic one-point calibration at 1413 µS\/cm with one button\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature compensation; °C or °F display\u003c\/li\u003e\n\u003cli\u003eLarge multi-level LCD with stability indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic shut-off (three user settings); Battery Error Prevention System (BEPS)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC range\u003c\/th\u003e\n\u003ctd\u003e0 to 2000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC resolution\u003c\/th\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 1413 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, 0.0 to 50.0 °C (32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature coefficient\u003c\/th\u003e\n\u003ctd\u003e1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e0.0 to 50.0 °C (32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature resolution \/ accuracy\u003c\/th\u003e\n\u003ctd\u003e0.1 °C \/ ±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic shut-off\u003c\/th\u003e\n\u003ctd\u003e8 minutes, 60 minutes or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003eCR2032 3V (1 pc.), approx. 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e160 x 40 x 17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e68 g without battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cli\u003e1413 µS\/cm calibration solution sachets (4)\u003c\/li\u003e\n\u003cli\u003eCR2032 battery\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the EC range and accuracy?\u003c\/h4\u003e\u003cp\u003e0 to 2000 µS\/cm with 1 µS\/cm resolution and ±2% F.S. accuracy.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eAutomatically, at one point (1413 µS\/cm), with a single button press.\u003c\/p\u003e\u003ch4\u003eDoes it compensate for temperature?\u003c\/h4\u003e\u003cp\u003eYes, automatically from 0.0 to 50.0 °C, with a 1.9%\/°C coefficient. Temperature can be shown in °C or °F.\u003c\/p\u003e\u003ch4\u003eWhat battery does it use and how long does it last?\u003c\/h4\u003e\u003cp\u003eOne CR2032 3V battery, approximately 250 hours of continuous use.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eHanna describes the casing as waterproof and designed to float. No IP rating is stated - to confirm.\u003c\/p\u003e\u003ch4\u003eWhere can it be used?\u003c\/h4\u003e\u003cp\u003eDrinking water, water conditioning, irrigation water and environmental monitoring, in the lab or field.\u003c\/p\u003e\u003ch4\u003eDoes it shut off automatically?\u003c\/h4\u003e\u003cp\u003eYes, after 8 minutes or 60 minutes, or it can be disabled.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eProtective cap, four 1413 µS\/cm calibration solution sachets, CR2032 battery, instrument quality certificate and instruction manual.\u003c\/p\u003e\u003ch4\u003eCan it measure TDS?\u003c\/h4\u003e\u003cp\u003eNo, this model measures EC and temperature. For TDS see the DiST 1 (HI98301) and DiST 2 (HI98302).\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836492677417,"sku":"HI98303","price":6699.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi98303_angle.jpg?v=1795084675"},{"product_id":"hanna-hi98303p-conductivity-tester-atc-1999-us-cm","title":"Hanna HI98303P Conductivity Tester with ATC, 0-1999 µS\/cm","description":"\u003cp\u003eThe Hanna HI98303P is a pocket-sized, rugged conductivity tester with manual one-point calibration, measuring up to 1999 µS\/cm. It belongs to Hanna's DiST family used for monitoring EC in drinking water, reverse osmosis and aquaculture.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGraphite electrodes, non-oxidising\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature compensation (ATC)\u003c\/li\u003e\n\u003cli\u003eSimple one-point manual calibration with a side trimmer\u003c\/li\u003e\n\u003cli\u003eEasy to use and economical\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98303P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC range\u003c\/th\u003e\n\u003ctd\u003e0 to 1999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC resolution\u003c\/th\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC calibration\u003c\/th\u003e\n\u003ctd\u003eManual, one point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, 0 to 50 °C (32 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCell type\u003c\/th\u003e\n\u003ctd\u003eAmperometric graphite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e4 x 1.5V alkaline, approx. 200 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e175 x 41 x 23 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e95 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cli\u003eScrewdriver\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the EC range?\u003c\/h4\u003e\u003cp\u003e0 to 1999 µS\/cm with 1 µS\/cm resolution and ±2% F.S. accuracy.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eManually at one point: put the electrode in 1413 µS\/cm calibration solution and adjust the side trimmer.\u003c\/p\u003e\u003ch4\u003eDoes it compensate for temperature?\u003c\/h4\u003e\u003cp\u003eYes, automatic compensation from 0 to 50 °C.\u003c\/p\u003e\u003ch4\u003eWhat batteries does it use?\u003c\/h4\u003e\u003cp\u003eFour 1.5V alkaline batteries, approximately 200 hours of continuous use.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eThe page does not describe this model as waterproof. The HI98303 (DiST 3) is the waterproof version.\u003c\/p\u003e\u003ch4\u003eDoes it measure TDS?\u003c\/h4\u003e\u003cp\u003eThe specifications list EC only; no TDS range is given.\u003c\/p\u003e\u003ch4\u003eWhat electrode does it use?\u003c\/h4\u003e\u003cp\u003eAn amperometric graphite electrode, which Hanna says does not oxidise.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eProtective cap, screwdriver, batteries and instructions.\u003c\/p\u003e\u003ch4\u003eIs a calibration solution included?\u003c\/h4\u003e\u003cp\u003eNot listed in the supplied items - to confirm. Hanna sells the 1413 µS\/cm standard separately.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836492841257,"sku":"HI98303P","price":1899.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/HI98303P.jpg?v=1795084699"},{"product_id":"hanna-hi98301-dist1-waterproof-tds-tester-0-2000-ppm","title":"Hanna HI98301 DiST 1 Waterproof TDS Tester, 0-2000 ppm","description":"\u003cp\u003eThe Hanna HI98301 DiST 1 is a pocket-sized, rugged, low-range TDS tester measuring up to 2000 ppm (mg\/L) with a 0.5 EC-to-TDS conversion factor, for water conditioning, environmental monitoring, education and general lab use.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSlim, ergonomic case, 17 mm thick\u003c\/li\u003e\n\u003cli\u003eLarge multi-level LCD showing TDS and temperature together\u003c\/li\u003e\n\u003cli\u003eExposed temperature sensor; automatic temperature compensation; °C or °F\u003c\/li\u003e\n\u003cli\u003eGraphite amperometric electrode that resists oxidation\u003c\/li\u003e\n\u003cli\u003eAutomatic one-point calibration at 1382 ppm with one button\u003c\/li\u003e\n\u003cli\u003eStability indicator; battery percentage at start-up; low-battery indicator\u003c\/li\u003e\n\u003cli\u003eAuto shut-off: 8 min, 60 min or disabled\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS range\u003c\/th\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS resolution\u003c\/th\u003e\n\u003ctd\u003e1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 1382 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, 0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature coefficient\u003c\/th\u003e\n\u003ctd\u003e1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC to TDS conversion factor\u003c\/th\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e0.0 to 50.0 °C (32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature resolution \/ accuracy\u003c\/th\u003e\n\u003ctd\u003e0.1 °C \/ ±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic shut-off\u003c\/th\u003e\n\u003ctd\u003e8 minutes, 60 minutes or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003eCR2032 3V (1 pc.), approx. 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e160 x 40 x 17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e68 g without battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cli\u003e1382 ppm calibration solution sachets (4)\u003c\/li\u003e\n\u003cli\u003eCR2032 battery\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003cli\u003eInstructional manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the TDS range and accuracy?\u003c\/h4\u003e\u003cp\u003e0 to 2000 ppm (mg\/L), 1 ppm resolution, ±2% F.S. accuracy.\u003c\/p\u003e\u003ch4\u003eWhat conversion factor does it use?\u003c\/h4\u003e\u003cp\u003eAn EC-to-TDS conversion factor of 0.5.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eAutomatically at one point, 1382 ppm, using a dedicated button.\u003c\/p\u003e\u003ch4\u003eDoes it compensate for temperature?\u003c\/h4\u003e\u003cp\u003eYes, automatically from 0 to 50 °C with a 1.9%\/°C coefficient.\u003c\/p\u003e\u003ch4\u003eWhat battery and how long does it last?\u003c\/h4\u003e\u003cp\u003eOne CR2032 3V battery, approximately 250 hours of continuous use.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eHanna describes it as waterproof. No IP rating is stated - to confirm.\u003c\/p\u003e\u003ch4\u003eDoes it shut off automatically?\u003c\/h4\u003e\u003cp\u003eYes, after 8 minutes or 60 minutes, or the feature can be disabled.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eProtective cap, four 1382 ppm calibration sachets, CR2032 battery, quality certificate and manual.\u003c\/p\u003e\u003ch4\u003eIs it available now?\u003c\/h4\u003e\u003cp\u003eTo confirm: Hanna's page shows 'pre-order, ships in 5 to 6 weeks' together with an Add to cart button.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836492874025,"sku":"HI98301","price":6699.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi98301-new-cover-on_1.jpg?v=1795084700"},{"product_id":"hanna-hi98302-dist2-waterproof-high-range-tds-tester","title":"Hanna HI98302 DiST 2 Waterproof High Range TDS Tester, 0-10 ppt","description":"\u003cp\u003eThe Hanna HI98302 DiST 2 is a pocket-sized, waterproof high-range TDS tester measuring up to 10.00 ppt (g\/L), for cooling towers, laboratories and agriculture.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLarge multi-level LCD with TDS, temperature, calibration tag, battery level and stability indicator\u003c\/li\u003e\n\u003cli\u003eExposed temperature probe for fast, stable readings\u003c\/li\u003e\n\u003cli\u003eTwo-button operation (on\/off and calibration)\u003c\/li\u003e\n\u003cli\u003eWaterproof casing designed to float\u003c\/li\u003e\n\u003cli\u003eGraphite sensor that reduces polarization and does not oxidise\u003c\/li\u003e\n\u003cli\u003eOne-push automatic calibration at 6.44 ppt\u003c\/li\u003e\n\u003cli\u003eAutomatic shut-off with three settings; BEPS and low-battery indicator\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS range\u003c\/th\u003e\n\u003ctd\u003e0.00 to 10.00 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 6.44 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, 0.0 to 50.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature coefficient\u003c\/th\u003e\n\u003ctd\u003e1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC to TDS conversion factor\u003c\/th\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e0.0 to 50.0 °C (32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature resolution \/ accuracy\u003c\/th\u003e\n\u003ctd\u003e0.1 °C \/ ±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic shut-off\u003c\/th\u003e\n\u003ctd\u003e8 minutes, 60 minutes or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003eCR2032 3V (1 pc.), approx. 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e160 x 40 x 17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e68 g without battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cli\u003e6.44 ppt calibration solution sachets (4)\u003c\/li\u003e\n\u003cli\u003eCR2032 battery\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003cli\u003eInstructional manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the TDS range?\u003c\/h4\u003e\u003cp\u003e0.00 to 10.00 ppt (g\/L) with 0.01 ppt resolution and ±2% F.S. accuracy.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eAutomatically at one point, 6.44 ppt, with one push.\u003c\/p\u003e\u003ch4\u003eWhat is the EC-to-TDS factor?\u003c\/h4\u003e\u003cp\u003e0.5.\u003c\/p\u003e\u003ch4\u003eDoes it compensate for temperature?\u003c\/h4\u003e\u003cp\u003eYes, automatically from 0.0 to 50.0 °C.\u003c\/p\u003e\u003ch4\u003eWhat battery and how long does it last?\u003c\/h4\u003e\u003cp\u003eOne CR2032 3V battery, approximately 250 hours of continuous use.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eHanna describes the casing as waterproof and floating. No IP rating is stated - to confirm.\u003c\/p\u003e\u003ch4\u003eWhere is it used?\u003c\/h4\u003e\u003cp\u003eHanna lists cooling towers, laboratories and agriculture.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eProtective cap, four 6.44 ppt calibration sachets, CR2032 battery, quality certificate and manual.\u003c\/p\u003e\u003ch4\u003eDoes it shut off automatically?\u003c\/h4\u003e\u003cp\u003eYes, after 8 minutes or 60 minutes, or disabled.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836492939561,"sku":"HI98302","price":6699.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi98302-new-cover-on_1.jpg?v=1795084725"},{"product_id":"hanna-hi98318-groline-waterproof-ec-tds-tester","title":"Hanna HI98318 GroLine Waterproof EC\/TDS Tester for Hydroponics","description":"\u003cp\u003eThe Hanna HI98318 GroLine is a pocket-style, waterproof EC\/TDS tester for hydroponic nutrient solutions, measuring fertiliser concentration as EC up to 6.00 mS\/cm or TDS.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWaterproof\u003c\/li\u003e\n\u003cli\u003eFast automatic temperature compensation with exposed temperature probe\u003c\/li\u003e\n\u003cli\u003eGraphite sensors that reduce polarization effects\u003c\/li\u003e\n\u003cli\u003eSelectable EC-to-TDS conversion factor: 0.5 (500 ppm) or 0.7 (700 ppm)\u003c\/li\u003e\n\u003cli\u003eSingle-point automatic calibration (Quick Cal standard or 1.41 mS\/cm)\u003c\/li\u003e\n\u003cli\u003eCalibration, stability and low-battery indicators\u003c\/li\u003e\n\u003cli\u003eSupplied with a rugged plastic carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98318\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC range\u003c\/th\u003e\n\u003ctd\u003e0.00 to 6.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, single point (1.41 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS range\u003c\/th\u003e\n\u003ctd\u003e0 to 3000 ppm (0.5 factor); 0 to 4000 ppm (0.7 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS resolution\u003c\/th\u003e\n\u003ctd\u003e10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS calibration\u003c\/th\u003e\n\u003ctd\u003eThrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, 0.0 to 50.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e0.0 to 50.0 °C (32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature resolution \/ accuracy\u003c\/th\u003e\n\u003ctd\u003e0.1 °C \/ ±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic shut-off\u003c\/th\u003e\n\u003ctd\u003e8 min, 60 min or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003eCR2032 3V (1 pc.), approx. 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH 100% max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e68 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eQuick Cal pH and EC one-point calibration solution sachets (4)\u003c\/li\u003e\n\u003cli\u003eCR2032 battery\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003cli\u003eQuality certificate\u003c\/li\u003e\n\u003cli\u003eRugged plastic carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat does it measure?\u003c\/h4\u003e\u003cp\u003eEC (0.00 to 6.00 mS\/cm) and TDS (0 to 3000 ppm at factor 0.5, 0 to 4000 ppm at factor 0.7), plus temperature.\u003c\/p\u003e\u003ch4\u003eCan I change the TDS conversion factor?\u003c\/h4\u003e\u003cp\u003eYes, you can select 0.5 or 0.7.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eSingle-point automatic calibration using the Quick Cal standard or the 1.41 mS\/cm standard.\u003c\/p\u003e\u003ch4\u003eDoes it compensate for temperature?\u003c\/h4\u003e\u003cp\u003eYes, automatically from 0.0 to 50.0 °C.\u003c\/p\u003e\u003ch4\u003eWhat battery does it use?\u003c\/h4\u003e\u003cp\u003eOne CR2032 3V battery, approximately 250 hours of continuous use.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eHanna describes it as waterproof. No IP rating is stated - to confirm.\u003c\/p\u003e\u003ch4\u003eWhat is it designed for?\u003c\/h4\u003e\u003cp\u003eHydroponic nutrient solutions.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eFour Quick Cal calibration sachets, CR2032 battery, instruction manual, quality certificate and a rugged plastic carrying case.\u003c\/p\u003e\u003ch4\u003eDoes it shut off automatically?\u003c\/h4\u003e\u003cp\u003eYes: selectable 8 minutes, 60 minutes or disabled.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836492972329,"sku":"HI98318","price":8099.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi98318-cap-on.jpg?v=1795084726"},{"product_id":"hanna-hi98312-dist6-ec-tds-temperature-tester","title":"Hanna HI98312 DiST 6 EC\/TDS\/Temperature Tester, 0-20 mS\/cm","description":"\u003cp\u003eThe Hanna HI98312 DiST 6 is a waterproof, floating 3-in-1 tester for EC, TDS and temperature, with a replaceable graphite conductivity electrode and an EC range up to 20.00 mS\/cm.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWaterproof and designed to float\u003c\/li\u003e\n\u003cli\u003eReplaceable graphite electrode, resistant to salt-deposit contamination\u003c\/li\u003e\n\u003cli\u003eAdjustable EC-to-TDS conversion factor and adjustable temperature coefficient (β)\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration; HOLD button to freeze the display\u003c\/li\u003e\n\u003cli\u003e°C or °F readout; exposed temperature probe\u003c\/li\u003e\n\u003cli\u003eBattery level indicator, BEPS low-battery alert, stability indicator, automatic shut-off\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98312\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC range\u003c\/th\u003e\n\u003ctd\u003e0.00 to 20.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 12.88 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS range\u003c\/th\u003e\n\u003ctd\u003e0.00 to 10.00 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 6.44 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, β adjustable 0.0 to 2.4%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC to TDS conversion factor\u003c\/th\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC\/TDS probe\u003c\/th\u003e\n\u003ctd\u003eHI73311 replaceable graphite electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e1.5V (4 pcs.), approx. 100 hours of continuous use; auto-off after 8 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e163 x 40 x 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHI73311 EC\/TDS probe\u003c\/li\u003e\n\u003cli\u003eHI73128 probe removal tool\u003c\/li\u003e\n\u003cli\u003eBatteries (4 x 1.5V)\u003c\/li\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat does it measure?\u003c\/h4\u003e\u003cp\u003eEC (0.00 to 20.00 mS\/cm), TDS (0.00 to 10.00 ppt) and temperature.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eAutomatically at one point: 12.88 mS\/cm for EC or 6.44 ppt for TDS.\u003c\/p\u003e\u003ch4\u003eCan I change the TDS conversion factor?\u003c\/h4\u003e\u003cp\u003eYes, from 0.45 to 1.00.\u003c\/p\u003e\u003ch4\u003eCan I adjust temperature compensation?\u003c\/h4\u003e\u003cp\u003eYes, β is adjustable from 0.0 to 2.4%\/°C.\u003c\/p\u003e\u003ch4\u003eIs the electrode replaceable?\u003c\/h4\u003e\u003cp\u003eYes, the HI73311 graphite electrode is replaceable and included.\u003c\/p\u003e\u003ch4\u003eWhat batteries does it use?\u003c\/h4\u003e\u003cp\u003eFour 1.5V batteries, approximately 100 hours of continuous use.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eHanna describes it as waterproof and floating. No IP rating is stated - to confirm.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eHI73311 probe, HI73128 probe removal tool, batteries and instructions.\u003c\/p\u003e\u003ch4\u003eDoes it have a HOLD function?\u003c\/h4\u003e\u003cp\u003eYes, a HOLD button freezes the display.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836493660457,"sku":"HI98312","price":13399.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi98312_1.jpg?v=1795084758"},{"product_id":"hanna-hi98304-dist4-waterproof-ec-tester-0-20-ms-cm","title":"Hanna HI98304 DiST 4 Waterproof EC Tester, 0-20 mS\/cm","description":"\u003cp\u003eThe Hanna HI98304 DiST 4 is a pocket-sized, waterproof high-range EC tester measuring up to 20.00 mS\/cm, for water treatment, boilers and cooling towers, agriculture including hydroponics, and general lab use.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLarge multi-level LCD with EC, temperature, calibration tag, battery level and stability indicator\u003c\/li\u003e\n\u003cli\u003eExposed temperature probe for fast compensated readings\u003c\/li\u003e\n\u003cli\u003eTwo-button operation (on\/off and calibration)\u003c\/li\u003e\n\u003cli\u003eGraphite amperometric electrode that resists oxidation\u003c\/li\u003e\n\u003cli\u003eAutomatic one-point calibration at 12.88 mS\/cm\u003c\/li\u003e\n\u003cli\u003eUser-selectable auto shut-off (8 min, 60 min, disabled)\u003c\/li\u003e\n\u003cli\u003eLow-battery indicator; battery percentage at start-up; °C or °F\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC range\u003c\/th\u003e\n\u003ctd\u003e0.00 to 20.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 12.88 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, 0.0 to 50.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature coefficient\u003c\/th\u003e\n\u003ctd\u003e1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e0.0 to 50.0 °C (32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature resolution \/ accuracy\u003c\/th\u003e\n\u003ctd\u003e0.1 °C \/ ±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic shut-off\u003c\/th\u003e\n\u003ctd\u003e8 minutes, 60 minutes or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003eCR2032 3V (1 pc.), approx. 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e160 x 40 x 17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e68 g without battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cli\u003e12.88 mS\/cm calibration solution sachets (4)\u003c\/li\u003e\n\u003cli\u003eCR2032 battery\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003cli\u003eInstructional manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the EC range and accuracy?\u003c\/h4\u003e\u003cp\u003e0.00 to 20.00 mS\/cm, 0.01 mS\/cm resolution, ±2% F.S.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eAutomatically at one point, 12.88 mS\/cm.\u003c\/p\u003e\u003ch4\u003eDoes it compensate for temperature?\u003c\/h4\u003e\u003cp\u003eYes, automatically from 0.0 to 50.0 °C with a 1.9%\/°C coefficient.\u003c\/p\u003e\u003ch4\u003eWhat battery does it use?\u003c\/h4\u003e\u003cp\u003eOne CR2032 3V battery, approximately 250 hours of continuous use.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eHanna describes it as waterproof. No IP rating is stated - to confirm.\u003c\/p\u003e\u003ch4\u003eWhere is it used?\u003c\/h4\u003e\u003cp\u003eWater treatment, boilers and cooling towers, agriculture including hydroponics, and general lab use.\u003c\/p\u003e\u003ch4\u003eDoes it measure TDS?\u003c\/h4\u003e\u003cp\u003eNo, this model measures EC and temperature.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eProtective cap, four 12.88 mS\/cm calibration sachets, CR2032 battery, quality certificate and manual.\u003c\/p\u003e\u003ch4\u003eDoes it shut off automatically?\u003c\/h4\u003e\u003cp\u003eYes, after 8 minutes or 60 minutes, or disabled.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836493693225,"sku":"HI98304","price":6699.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi98304-new-cover-on_1.jpg?v=1795084760"},{"product_id":"hanna-hi98308-pure-water-tester-0-99-9-us-cm","title":"Hanna HI98308 Pure Water Tester, 0-99.9 µS\/cm","description":"\u003cp\u003eThe Hanna HI98308 is a rugged, pocket-sized conductivity tester for pure, distilled and demineralised water, with a 0.0 to 99.9 µS\/cm range and 0.1 µS\/cm resolution.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVery low range EC: 0.0 to 99.9 µS\/cm\u003c\/li\u003e\n\u003cli\u003eExposed temperature sensor for fast response\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature compensation from 0 to 50 °C\u003c\/li\u003e\n\u003cli\u003eSingle-point manual calibration with an 84 µS\/cm solution\u003c\/li\u003e\n\u003cli\u003eGraphite electrodes with reduced polarization effects\u003c\/li\u003e\n\u003cli\u003eCasing designed for harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC range\u003c\/th\u003e\n\u003ctd\u003e0.0 to 99.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC calibration\u003c\/th\u003e\n\u003ctd\u003eManual, one point (84 µS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, 0 to 50 °C (32 to 122 °F), β = 2%\/°C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e1.5V (4 pcs.), approx. 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e175 x 41 x 23 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e95 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cli\u003eCalibration screwdriver\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the measuring range?\u003c\/h4\u003e\u003cp\u003e0.0 to 99.9 µS\/cm with 0.1 µS\/cm resolution and ±2% F.S. accuracy.\u003c\/p\u003e\u003ch4\u003eWhat water is it for?\u003c\/h4\u003e\u003cp\u003eHanna lists distilled, demineralised and other pure water, including PCB washing, laundry, steam cleaning and car battery water checks.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eManually at one point: immerse the tip in 84 µS\/cm solution and adjust the side trimmer with the screwdriver.\u003c\/p\u003e\u003ch4\u003eDoes it compensate for temperature?\u003c\/h4\u003e\u003cp\u003eYes, automatically from 0 to 50 °C.\u003c\/p\u003e\u003ch4\u003eWhat batteries does it use?\u003c\/h4\u003e\u003cp\u003eFour 1.5V batteries, approximately 250 hours of continuous use.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eThe page does not describe it as waterproof.\u003c\/p\u003e\u003ch4\u003eIs calibration solution included?\u003c\/h4\u003e\u003cp\u003eNot listed in the supplied items - to confirm.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eProtective cap, calibration screwdriver, batteries and instructions.\u003c\/p\u003e\u003ch4\u003eWhich model is for ultra pure water?\u003c\/h4\u003e\u003cp\u003eThe HI98309 UPW tester measures 0.000 to 1.999 µS\/cm.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836493725993,"sku":"HI98308","price":8599.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi98308-pwt_1.jpg?v=1795084761"},{"product_id":"hanna-hi98309-ultra-pure-water-tester-0-1-999-us-cm","title":"Hanna HI98309 Ultra Pure Water (UPW) Tester, 0-1.999 µS\/cm","description":"\u003cp\u003eThe Hanna HI98309 is a pocket-sized, factory-calibrated conductivity tester for ultra pure water, aimed at electronics and semiconductor users, with 0.001 µS\/cm resolution over 0.000 to 1.999 µS\/cm.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFactory-calibrated with freshly prepared low-conductivity solutions\u003c\/li\u003e\n\u003cli\u003eReads 0.000 to 1.999 µS\/cm in 0.001 µS\/cm steps\u003c\/li\u003e\n\u003cli\u003eExposed temperature probe for fast response\u003c\/li\u003e\n\u003cli\u003eGraphite electrodes with reduced polarization effects\u003c\/li\u003e\n\u003cli\u003eCasing designed for harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eCalibration can be adjusted with a side trimmer\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC range\u003c\/th\u003e\n\u003ctd\u003e0.000 to 1.999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC resolution\u003c\/th\u003e\n\u003ctd\u003e0.001 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC calibration\u003c\/th\u003e\n\u003ctd\u003eFactory calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e1.5V (4 pcs.), approx. 200 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e175 x 41 x 23 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e95 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the measuring range?\u003c\/h4\u003e\u003cp\u003e0.000 to 1.999 µS\/cm with 0.001 µS\/cm resolution and ±2% F.S. accuracy.\u003c\/p\u003e\u003ch4\u003eWho is it for?\u003c\/h4\u003e\u003cp\u003eHanna aims it mainly at electronics and semiconductor users checking ultra pure water.\u003c\/p\u003e\u003ch4\u003eIs it calibrated?\u003c\/h4\u003e\u003cp\u003eYes, it is factory calibrated; calibration can be adjusted with the side trimmer using calibration solution.\u003c\/p\u003e\u003ch4\u003eDoes it list temperature compensation?\u003c\/h4\u003e\u003cp\u003eThe specifications do not list it - to confirm.\u003c\/p\u003e\u003ch4\u003eWhat batteries does it use?\u003c\/h4\u003e\u003cp\u003eFour 1.5V batteries, approximately 200 hours of continuous use.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eThe page does not describe it as waterproof.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eProtective cap, batteries and instructions.\u003c\/p\u003e\u003ch4\u003eWhich model is for less pure water?\u003c\/h4\u003e\u003cp\u003eThe HI98308 Pure Water Tester measures 0.0 to 99.9 µS\/cm.\u003c\/p\u003e\u003ch4\u003eWhat are the operating conditions?\u003c\/h4\u003e\u003cp\u003e0 to 50 °C, RH max 95% non-condensing.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836493988137,"sku":"HI98309","price":8599.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi98309-upw.jpg?v=1795084803"},{"product_id":"hanna-hi983124-pool-line-ec-tds-tester-high-range","title":"Hanna HI983124 Pool Line EC\/TDS Tester, High Range","description":"\u003cp\u003eThe Hanna HI983124 is a handheld, lightweight, waterproof high-range EC\/TDS and temperature tester for measuring salt levels in swimming pools, hot tubs and spas. It is designed to float.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWaterproof and designed to float\u003c\/li\u003e\n\u003cli\u003eReplaceable amperometric graphite EC\/TDS electrode (HI73311)\u003c\/li\u003e\n\u003cli\u003eSelectable EC-to-TDS conversion factor (0.45 to 1.00)\u003c\/li\u003e\n\u003cli\u003eUser-selectable temperature compensation coefficient (β)\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature compensation; °C or °F\u003c\/li\u003e\n\u003cli\u003eLarge LCD with stability, low-battery and calibration tags\u003c\/li\u003e\n\u003cli\u003eBEPS with battery percentage at start-up; auto-off after 8 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI983124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC range\u003c\/th\u003e\n\u003ctd\u003e0.00 to 20.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 12.88 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS range\u003c\/th\u003e\n\u003ctd\u003e0.00 to 10.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 6.44 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, β = 0.0 to 2.4%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC to TDS conversion factor\u003c\/th\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e0.0 to 60.0 °C (32.0 to 140.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature resolution \/ accuracy\u003c\/th\u003e\n\u003ctd\u003e0.1 °C \/ ±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrode\u003c\/th\u003e\n\u003ctd\u003eHI73311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e1.5V (4 pcs.), approx. 100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e171 x 41 x 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e85 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHI700304 12880 µS\/cm conductivity standard (3 x 20 mL sachets)\u003c\/li\u003e\n\u003cli\u003eHI700384 6.44 ppt TDS standard (3 x 20 mL sachets)\u003c\/li\u003e\n\u003cli\u003eHI73311 EC\/TDS electrode\u003c\/li\u003e\n\u003cli\u003eHI73128 electrode extraction tool\u003c\/li\u003e\n\u003cli\u003eStorage \/ protective cap\u003c\/li\u003e\n\u003cli\u003eBatteries (4 x 1.5V)\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is it used for?\u003c\/h4\u003e\u003cp\u003eMeasuring salt levels in swimming pools, hot tubs and spas.\u003c\/p\u003e\u003ch4\u003eWhat is the EC and TDS range?\u003c\/h4\u003e\u003cp\u003eEC 0.00 to 20.00 mS\/cm and TDS 0.00 to 10.00 ppt, both with ±2% of full scale accuracy.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eAutomatically at one point: 12.88 mS\/cm for EC or 6.44 ppt for TDS. Calibration sachets are supplied.\u003c\/p\u003e\u003ch4\u003eCan I change the conversion factor?\u003c\/h4\u003e\u003cp\u003eYes, the EC-to-TDS factor is selectable from 0.45 to 1.00.\u003c\/p\u003e\u003ch4\u003eIs the electrode replaceable?\u003c\/h4\u003e\u003cp\u003eYes, the HI73311 electrode is replaceable and an extraction tool is supplied.\u003c\/p\u003e\u003ch4\u003eWhat batteries does it use?\u003c\/h4\u003e\u003cp\u003eFour 1.5V batteries, approximately 100 hours.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eHanna describes it as waterproof and floating. No IP rating is stated - to confirm.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eCalibration sachets (12880 µS\/cm and 6.44 ppt), HI73311 electrode, HI73128 extraction tool, protective cap, batteries, quality certificate and manual.\u003c\/p\u003e\u003ch4\u003eDoes it shut off automatically?\u003c\/h4\u003e\u003cp\u003eYes, after 8 minutes of non-use.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836494020905,"sku":"HI983124","price":13399.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi983124.jpg?v=1795084805"},{"product_id":"hanna-hi98311-dist5-ec-tds-temperature-tester","title":"Hanna HI98311 DiST 5 EC\/TDS\/Temperature Tester, 0-3999 µS\/cm","description":"\u003cp\u003eThe Hanna HI98311 DiST 5 is a waterproof, floating 3-in-1 tester for EC (0 to 3999 µS\/cm), TDS (0 to 2000 ppm) and temperature, with a replaceable graphite electrode.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWaterproof and designed to float\u003c\/li\u003e\n\u003cli\u003eReplaceable graphite electrode, resistant to salt-deposit contamination\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature compensation with adjustable β; adjustable TDS ratio\u003c\/li\u003e\n\u003cli\u003eSwitchable °C \/ °F; HOLD button to freeze the display\u003c\/li\u003e\n\u003cli\u003eBattery level indicator with BEPS low-battery alert; stability indicator\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration and automatic shut-off\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC range\u003c\/th\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC resolution\u003c\/th\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 1413 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS range\u003c\/th\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS resolution\u003c\/th\u003e\n\u003ctd\u003e1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 1382 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, β adjustable 0.0 to 2.4%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC to TDS conversion factor\u003c\/th\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e0.0 to 60.0 °C (32.0 to 140.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature resolution \/ accuracy\u003c\/th\u003e\n\u003ctd\u003e0.1 °C \/ ±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC\/TDS probe\u003c\/th\u003e\n\u003ctd\u003eHI73311 replaceable graphite electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic shut-off\u003c\/th\u003e\n\u003ctd\u003eAfter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e1.5V (4 pcs.), approx. 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e163 x 40 x 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHI73311 EC\/TDS probe\u003c\/li\u003e\n\u003cli\u003eHI73128 probe removal tool\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat does it measure?\u003c\/h4\u003e\u003cp\u003eEC (0 to 3999 µS\/cm), TDS (0 to 2000 ppm) and temperature.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eAutomatically at one point: 1413 µS\/cm for EC or 1382 ppm for TDS.\u003c\/p\u003e\u003ch4\u003eCan I adjust the TDS ratio?\u003c\/h4\u003e\u003cp\u003eYes, the EC-to-TDS factor is adjustable from 0.45 to 1.00.\u003c\/p\u003e\u003ch4\u003eCan I adjust temperature compensation?\u003c\/h4\u003e\u003cp\u003eYes, β is adjustable from 0.0 to 2.4%\/°C.\u003c\/p\u003e\u003ch4\u003eIs the electrode replaceable?\u003c\/h4\u003e\u003cp\u003eYes, the HI73311 graphite electrode is replaceable and included.\u003c\/p\u003e\u003ch4\u003eWhat batteries does it use?\u003c\/h4\u003e\u003cp\u003eFour 1.5V batteries, approximately 100 hours of continuous use.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eHanna describes it as waterproof and floating. No IP rating is stated - to confirm.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eHI73311 probe, HI73128 probe removal tool, batteries and instructions.\u003c\/p\u003e\u003ch4\u003eDoes it shut off automatically?\u003c\/h4\u003e\u003cp\u003eYes, after 8 minutes of non-use.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836494053673,"sku":"HI98311","price":13399.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi98311.jpg?v=1795084806"},{"product_id":"hanna-hi98331-soil-test-direct-soil-ec-tester","title":"Hanna HI98331 Soil Test Direct Soil EC Tester","description":"\u003cp\u003eThe Hanna HI98331 Soil Test is a pocket-sized tester that measures soil electrical conductivity (EC) and temperature directly in the soil, so no soil slurry is needed. It has single-button operation and automatic calibration.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDirect soil EC measurement without a slurry\u003c\/li\u003e\n\u003cli\u003e114 mm (4.5 in) stainless steel penetration electrode\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature compensation (fixed 2%\/°C coefficient)\u003c\/li\u003e\n\u003cli\u003eOne-point automatic calibration to a 1413 µS\/cm standard\u003c\/li\u003e\n\u003cli\u003eDescribed by Hanna as waterproof\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eHI98331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC range\u003c\/th\u003e\n\u003ctd\u003e0 to 4000 µS\/cm; 0.00 to 4.00 mS\/cm (dS\/m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC resolution\u003c\/th\u003e\n\u003ctd\u003e1 µS\/cm; 0.01 mS\/cm (dS\/m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC accuracy\u003c\/th\u003e\n\u003ctd\u003e±50 µS\/cm (0 to 2000 µS\/cm), ±300 µS\/cm (2000 to 4000 µS\/cm); ±0.05 mS\/cm (0.00 to 2.00 mS\/cm), ±0.30 mS\/cm (2.00 to 4.00 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEC calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, one point at 1.41 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, β fixed at 2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e0.0 to 50.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature resolution \/ accuracy\u003c\/th\u003e\n\u003ctd\u003e0.1 °C \/ ±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProbe\u003c\/th\u003e\n\u003ctd\u003e114 mm (4.5 in) stainless steel penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003eCR2032, approx. 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C; RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e50 x 196 x 21 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e74 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSupplied in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStainless steel penetration probe\u003c\/li\u003e\n\u003cli\u003eBatteries (quantity to confirm)\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat does it measure?\u003c\/h4\u003e\u003cp\u003eSoil EC and temperature, directly in the soil.\u003c\/p\u003e\u003ch4\u003eWhat is the EC range?\u003c\/h4\u003e\u003cp\u003e0 to 4000 µS\/cm (0.00 to 4.00 mS\/cm).\u003c\/p\u003e\u003ch4\u003eDo I need a soil slurry?\u003c\/h4\u003e\u003cp\u003eNo, the penetration electrode measures directly in the soil.\u003c\/p\u003e\u003ch4\u003eHow is it calibrated?\u003c\/h4\u003e\u003cp\u003eAutomatically at one point with a 1413 µS\/cm standard, by submerging the tip in the solution.\u003c\/p\u003e\u003ch4\u003eDoes it compensate for temperature?\u003c\/h4\u003e\u003cp\u003eYes, automatically with a fixed 2%\/°C coefficient.\u003c\/p\u003e\u003ch4\u003eHow long is the probe?\u003c\/h4\u003e\u003cp\u003e114 mm (4.5 inches), stainless steel.\u003c\/p\u003e\u003ch4\u003eIs it waterproof?\u003c\/h4\u003e\u003cp\u003eHanna describes it as waterproof. No IP rating is stated - to confirm.\u003c\/p\u003e\u003ch4\u003eWhat is supplied in the box?\u003c\/h4\u003e\u003cp\u003eStainless steel penetration probe, batteries and an instrument quality certificate. Calibration solution is not listed.\u003c\/p\u003e\u003ch4\u003eDoes it measure TDS?\u003c\/h4\u003e\u003cp\u003eHanna describes it as an EC and temperature tester; TDS is not listed.\u003c\/p\u003e\u003ch4\u003eWill I get a GST invoice, and can I get a bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. Labmart (Chemlab Equipment) issues a GST invoice with every order. For colleges, hospitals, pharma and government labs we provide quotations for bulk and institutional purchases; send us your requirement on WhatsApp or email.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":67836494086441,"sku":"HI98331","price":12199.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/hi98331-groline-2017.jpg?v=1795084807"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/collections\/hi98128_phep5.jpg?v=1795085301","url":"https:\/\/www.labmart.in\/collections\/water-testing-meters.oembed","provider":"Labmart.in","version":"1.0","type":"link"}