{"title":"UV VIS Single Beam Spectrophotometer","description":"\u003ch2 data-section-id=\"18q4yv7\" data-start=\"125\" data-end=\"221\"\u003e🔬 Single Beam Spectrophotometers – Buy Digital Single Beam Spectrophotometer Online in India\u003c\/h2\u003e\n\u003cp data-start=\"223\" data-end=\"808\"\u003eExplore a reliable range of \u003cstrong data-start=\"251\" data-end=\"294\"\u003esingle beam spectrophotometers in India\u003c\/strong\u003e at \u003cstrong data-start=\"298\" data-end=\"309\"\u003eLabmart\u003c\/strong\u003e, designed for \u003cstrong data-start=\"324\" data-end=\"408\"\u003eaccurate absorbance and transmittance measurement in routine laboratory analysis\u003c\/strong\u003e. Our collection includes \u003cstrong data-start=\"434\" data-end=\"636\"\u003edigital single beam spectrophotometers, visible single beam spectrophotometers, microprocessor-based spectrophotometers, compact laboratory spectrophotometers, and entry-level analytical instruments\u003c\/strong\u003e, ideal for \u003cstrong data-start=\"648\" data-end=\"807\"\u003echemical laboratories, pharmaceutical industries, environmental testing labs, food \u0026amp; beverage industries, research institutes, and educational institutions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"810\" data-end=\"1154\"\u003eLabmart offers \u003cstrong data-start=\"825\" data-end=\"879\"\u003ehigh-quality single beam spectrophotometers online\u003c\/strong\u003e that ensure \u003cstrong data-start=\"892\" data-end=\"974\"\u003eprecise optical measurements, stable performance, and cost-effective operation\u003c\/strong\u003e. These instruments are essential for \u003cstrong data-start=\"1012\" data-end=\"1092\"\u003equantitative analysis, concentration determination, and colorimetric testing\u003c\/strong\u003e, making them widely used for routine laboratory applications.\u003c\/p\u003e\n\u003cp data-start=\"1156\" data-end=\"1357\"\u003eWhether you need a \u003cstrong data-start=\"1175\" data-end=\"1279\"\u003ebudget-friendly spectrophotometer for teaching labs or a dependable system for daily analytical work\u003c\/strong\u003e, Labmart provides \u003cstrong data-start=\"1298\" data-end=\"1356\"\u003edurable, user-friendly, and high-performance solutions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1359\" data-end=\"1362\"\u003e\n\u003ch2 data-section-id=\"q1ry0n\" data-start=\"1364\" data-end=\"1438\"\u003e🔑 Why Labmart.in is the Go-To Place for Single Beam Spectrophotometers\u003c\/h2\u003e\n\u003cul data-start=\"1440\" data-end=\"1929\"\u003e\n\u003cli data-section-id=\"j8gndv\" data-start=\"1440\" data-end=\"1514\"\u003e✔ Wide range of \u003cstrong data-start=\"1458\" data-end=\"1512\"\u003edigital and visible single beam spectrophotometers\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b8qxip\" data-start=\"1515\" data-end=\"1584\"\u003e✔ High accuracy for \u003cstrong data-start=\"1537\" data-end=\"1582\"\u003eabsorbance and concentration measurements\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1km1w7u\" data-start=\"1585\" data-end=\"1650\"\u003e✔ Cost-effective solution for \u003cstrong data-start=\"1617\" data-end=\"1648\"\u003eroutine laboratory analysis\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14f9wln\" data-start=\"1651\" data-end=\"1720\"\u003e✔ Compact and easy-to-use systems for \u003cstrong data-start=\"1691\" data-end=\"1718\"\u003eeducational and lab use\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4q565k\" data-start=\"1721\" data-end=\"1798\"\u003e✔ Competitive pricing for \u003cstrong data-start=\"1749\" data-end=\"1796\"\u003elabs, industries, and institutions in India\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dv9f4l\" data-start=\"1799\" data-end=\"1864\"\u003e✔ Trusted supplier of \u003cstrong data-start=\"1823\" data-end=\"1862\"\u003escientific and laboratory equipment\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uu543w\" data-start=\"1865\" data-end=\"1929\"\u003e✔ Reliable support and seamless online purchasing experience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1931\" data-end=\"2088\"\u003eLabmart.in is a \u003cstrong data-start=\"1947\" data-end=\"2024\"\u003etrusted destination to buy single beam spectrophotometers online in India\u003c\/strong\u003e, offering dependable solutions for everyday analytical testing.\u003c\/p\u003e\n\u003chr data-start=\"2090\" data-end=\"2093\"\u003e\n\u003ch2 data-section-id=\"1mz6hso\" data-start=\"2095\" data-end=\"2147\"\u003e🧪 Applications of Single Beam Spectrophotometers\u003c\/h2\u003e\n\u003cp data-start=\"2149\" data-end=\"2199\"\u003eSingle beam spectrophotometers are widely used in:\u003c\/p\u003e\n\u003cul data-start=\"2201\" data-end=\"2723\"\u003e\n\u003cli data-section-id=\"16etfnq\" data-start=\"2201\" data-end=\"2271\"\u003e💊 \u003cstrong data-start=\"2206\" data-end=\"2233\"\u003ePharmaceutical Industry\u003c\/strong\u003e – Drug analysis and quality control\u003c\/li\u003e\n\u003cli data-section-id=\"28cj4u\" data-start=\"2272\" data-end=\"2352\"\u003e🧪 \u003cstrong data-start=\"2277\" data-end=\"2302\"\u003eChemical Laboratories\u003c\/strong\u003e – Routine concentration and absorbance analysis\u003c\/li\u003e\n\u003cli data-section-id=\"yqvbch\" data-start=\"2353\" data-end=\"2416\"\u003e🌱 \u003cstrong data-start=\"2358\" data-end=\"2383\"\u003eEnvironmental Testing\u003c\/strong\u003e – Water and pollutant analysis\u003c\/li\u003e\n\u003cli data-section-id=\"12nnmhb\" data-start=\"2417\" data-end=\"2495\"\u003e🧫 \u003cstrong data-start=\"2422\" data-end=\"2450\"\u003eFood \u0026amp; Beverage Industry\u003c\/strong\u003e – Quality testing and composition analysis\u003c\/li\u003e\n\u003cli data-section-id=\"bcsgva\" data-start=\"2496\" data-end=\"2571\"\u003e🔬 \u003cstrong data-start=\"2501\" data-end=\"2526\"\u003eResearch Laboratories\u003c\/strong\u003e – Basic analytical and biochemical studies\u003c\/li\u003e\n\u003cli data-section-id=\"96kgq2\" data-start=\"2572\" data-end=\"2649\"\u003e🏭 \u003cstrong data-start=\"2577\" data-end=\"2604\"\u003eIndustrial Applications\u003c\/strong\u003e – Process monitoring and quality assurance\u003c\/li\u003e\n\u003cli data-section-id=\"o27231\" data-start=\"2650\" data-end=\"2723\"\u003e🏫 \u003cstrong data-start=\"2655\" data-end=\"2683\"\u003eEducational Institutions\u003c\/strong\u003e – Teaching and laboratory experiments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2725\" data-end=\"2728\"\u003e\n\u003ch2 data-section-id=\"ietzmw\" data-start=\"2730\" data-end=\"2768\"\u003e❓ Frequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003ch3 data-section-id=\"oxydwt\" data-start=\"2770\" data-end=\"2817\"\u003e1. What is a single beam spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"2818\" data-end=\"2945\"\u003eA single beam spectrophotometer is a \u003cstrong data-start=\"2855\" data-end=\"2944\"\u003edevice that measures light absorbance by passing a single light beam through a sample\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1jijcxk\" data-start=\"2947\" data-end=\"3022\"\u003e2. How is a single beam spectrophotometer different from a double beam?\u003c\/h3\u003e\n\u003cp data-start=\"3023\" data-end=\"3162\"\u003eSingle beam spectrophotometers measure \u003cstrong data-start=\"3062\" data-end=\"3086\"\u003eone sample at a time\u003c\/strong\u003e, while double beam systems compare \u003cstrong data-start=\"3122\" data-end=\"3161\"\u003esample and reference simultaneously\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"bld8ai\" data-start=\"3164\" data-end=\"3241\"\u003e3. What types of single beam spectrophotometers are available at Labmart?\u003c\/h3\u003e\n\u003cp data-start=\"3242\" data-end=\"3341\"\u003eLabmart offers \u003cstrong data-start=\"3257\" data-end=\"3340\"\u003edigital, visible range, and microprocessor-based single beam spectrophotometers\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"9qcpuc\" data-start=\"3343\" data-end=\"3399\"\u003e4. What is a single beam spectrophotometer used for?\u003c\/h3\u003e\n\u003cp data-start=\"3400\" data-end=\"3500\"\u003eIt is used for \u003cstrong data-start=\"3415\" data-end=\"3499\"\u003eroutine absorbance measurement, concentration analysis, and colorimetric testing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xvriib\" data-start=\"3502\" data-end=\"3573\"\u003e5. Are single beam spectrophotometers suitable for educational use?\u003c\/h3\u003e\n\u003cp data-start=\"3574\" data-end=\"3652\"\u003eYes, they are widely used in \u003cstrong data-start=\"3603\" data-end=\"3651\"\u003eschools, colleges, and training laboratories\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"126901w\" data-start=\"3654\" data-end=\"3715\"\u003e6. Do single beam spectrophotometers require calibration?\u003c\/h3\u003e\n\u003cp data-start=\"3716\" data-end=\"3788\"\u003eYes, regular calibration ensures \u003cstrong data-start=\"3749\" data-end=\"3787\"\u003eaccurate and reliable measurements\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1fjwk63\" data-start=\"3790\" data-end=\"3861\"\u003e7. Why should I buy single beam spectrophotometers from Labmart.in?\u003c\/h3\u003e\n\u003cp data-start=\"3862\" data-end=\"3995\"\u003eLabmart offers \u003cstrong data-start=\"3877\" data-end=\"3966\"\u003ehigh-quality instruments, competitive pricing, reliable support, and a wide selection\u003c\/strong\u003e, making it a trusted choice.\u003c\/p\u003e\n\u003c!----\u003e","products":[{"product_id":"uv-vis-single-beam-spectrophotometer","title":"UV-VIS Single Beam Spectrophotometer I Automatic Wavelength Setting I With Software","description":"\u003cp\u003eDiscover the UV-VIS Single Beam Spectrophotometer, your essential tool for precise measurements in the ultraviolet and visible spectrum. Analyze absorbance, transmittance, and concentration with ease. Ideal for research, education, and quality control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUnique optical system, 1200 lines\/mm grating.\u003c\/li\u003e\n\u003cli\u003eThe instrument has basic functions of photometric analysis and quantitative analysis.\u003c\/li\u003e\n\u003cli\u003eWith PC software, it expands the applications, such as spectral scanning, kinetics,\u003c\/li\u003e\n\u003cli\u003eDNA\/protein analysis,\u003c\/li\u003e\n\u003cli\u003emulti-wavelength test, etc...\u003c\/li\u003e\n\u003cli\u003eStore 200 test data and 100 standard curves;.\u003c\/li\u003e\n\u003cli\u003eDeuterium and Tungsten lamp can ON \/ OFF individually to increase the shelf life.\u003c\/li\u003e\n\u003cli\u003eLarge sample chamber can accommodate 5-100mm cuvettes.\u003c\/li\u003e\n\u003cli\u003ePhotometric Mode - T, A, C, E.\u003c\/li\u003e\n\u003cli\u003ePC software available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eOptical System : Single Beam, Grating 1200 lines\/mm\u003cbr\u003eSpectral Bandwidth : 2 nm\u003cbr\u003eWavelength Range : 190-1000nm\u003cbr\u003eWavelength Accuracy :  ± 1nm\u003cbr\u003eWavelength Repeatability :  + 0.5nm\u003cbr\u003ePhotometric Range :  0-200%T, -0.3~3A, 0-9999C\u003cbr\u003ePhotometric Accuracy :  ± 0.5%T\u003cbr\u003ePhotometric Repeatability :  ± 0.3%T\u003cbr\u003ePhotometric Mode :  T, A, C, E\u003cbr\u003eStray light :  ± 0.3%T\u003cbr\u003eStability :  ± 0.002A\/h @500nm\u003cbr\u003eBaseline Flatness : ±0.002 A\u003cbr\u003eNoise :  ±0.001 A\u003cbr\u003eWavelength Setting :  Auto\u003cbr\u003eDisplay :  128 x 64 LCD\u003cbr\u003eLight Source :  Deuterium \u0026amp; Tungsten lamp\u003cbr\u003eDetector :  Silicon Photodiode\u003cbr\u003eCell Holder :  4 position 10mm cell holder\u003cbr\u003eOutput :  RS232C\u003cbr\u003ePowersupply : AC 220V\/50Hz\u003cbr\u003ePacking Dimension :  (LxWxH) 700 x 580 x 340mm\u003cbr\u003eGross Weight :  19kg \u003c\/p\u003e\n\u003ch2 data-section-id=\"1xvwnkw\" data-start=\"1363\" data-end=\"1370\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1p5fzz2\" data-start=\"1372\" data-end=\"1435\"\u003e1. What is a UV VIS Single Beam Spectrophotometer used for?\u003c\/h3\u003e\n\u003cp data-start=\"1436\" data-end=\"1652\"\u003eA UV VIS Single Beam Spectrophotometer is used to measure absorbance, transmittance, and concentration of samples in ultraviolet and visible light ranges for laboratory analysis.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1e3vmqa\" data-start=\"1654\" data-end=\"1714\"\u003e2. Which industries commonly use this spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"1715\" data-end=\"1950\"\u003eThe instrument is widely used in pharmaceutical industries, chemical laboratories, environmental testing labs, food testing facilities, biotechnology research centers, and educational institutions.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"95c1cm\" data-start=\"1952\" data-end=\"2009\"\u003e3. What wavelength range does the instrument support?\u003c\/h3\u003e\n\u003cp data-start=\"2010\" data-end=\"2175\"\u003eMost UV-Vis single beam spectrophotometers support a wavelength range between 190–1100 nm for UV and visible spectrum analysis.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"2ph5gr\" data-start=\"2177\" data-end=\"2245\"\u003e4. What analytical modes are available in the spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"2246\" data-end=\"2404\"\u003eThe instrument commonly supports Transmittance (T), Absorbance (A), Concentration (C), and Energy (E) measurement modes.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ur8lfh\" data-start=\"2406\" data-end=\"2470\"\u003e5. Does the spectrophotometer support quantitative analysis?\u003c\/h3\u003e\n\u003cp data-start=\"2471\" data-end=\"2668\"\u003eYes, the system supports quantitative analysis, kinetics testing, spectral scanning, and multi-wavelength analysis through integrated or PC software functions.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"aeqiog\" data-start=\"2670\" data-end=\"2731\"\u003e6. What type of light sources are used in the instrument?\u003c\/h3\u003e\n\u003cp data-start=\"2732\" data-end=\"2880\"\u003eUV-Vis spectrophotometers generally use Deuterium and Tungsten lamps for UV and visible spectrum measurements.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"2d7cev\" data-start=\"2882\" data-end=\"2947\"\u003e7. Is the instrument suitable for routine laboratory testing?\u003c\/h3\u003e\n\u003cp data-start=\"2948\" data-end=\"3115\"\u003eYes, its stable optical system and easy operation make it ideal for routine laboratory analysis and quality control applications.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"16o28v4\" data-start=\"3117\" data-end=\"3183\"\u003e8. What are the advantages of a single beam spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"3184\" data-end=\"3381\"\u003eSingle beam spectrophotometers are cost-effective, compact, easy to maintain, and provide accurate analytical performance for standard laboratory applications.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"jdx4dv\" data-start=\"3383\" data-end=\"3438\"\u003e9. Can the spectrophotometer connect to a computer?\u003c\/h3\u003e\n\u003cp data-start=\"3439\" data-end=\"3596\"\u003eYes, many models support USB or RS232 connectivity for data transfer, spectrum scanning, and software-based analysis.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"wj2tq1\" data-start=\"3598\" data-end=\"3656\"\u003e10. Why choose a UV VIS Single Beam Spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"3657\" data-end=\"3878\"\u003eThe instrument offers reliable analytical accuracy, efficient operation, stable optical performance, and economical laboratory testing solutions for various scientific applications\u003c\/p\u003e","brand":"Labtical","offers":[{"title":"Default Title","offer_id":49259274404137,"sku":"UV-600","price":84999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/Labtical_UV600_UV-Vis_Single_Beam_Spectrophotometer_jpg.png?v=1777308378"},{"product_id":"uv-vis-single-beam-spectrophotometer-advanced","title":"UV-VIS Single Beam Spectrophotometer Advanced I With Software I Wavelength Accuracy 0.5nm","description":"\u003cp\u003eDiscover the UV-VIS Single Beam Spectrophotometer, your essential tool for precise measurements in the ultraviolet and visible spectrum. Analyze absorbance, transmittance, and concentration with ease. Ideal for research, education, and quality control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUnique optical system, 1200 lines\/mm grating.\u003c\/li\u003e\n\u003cli\u003eThe instrument has basic functions of photometric analysis and quantitative analysis.\u003c\/li\u003e\n\u003cli\u003eIt expands the applications, such as spectral scanning, kinetics, DNA\/protein analysis, multi-wavelength test, etc. with PC software.\u003c\/li\u003e\n\u003cli\u003eStore 200 test data and 100 standard curves;\u003c\/li\u003e\n\u003cli\u003eDeuterium and Tungsten lamp can ON \/ OFF individually to increase the shelf life.\u003c\/li\u003e\n\u003cli\u003eLarge sample chamber can accommodate 5-100mm cuvettes.\u003c\/li\u003e\n\u003cli\u003ePhotometric Mode - T, A, C, E.\u003c\/li\u003e\n\u003cli\u003ePC software available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e \u003c\/p\u003e\n\u003cdiv id=\"content_description\" class=\"ty-wysiwyg-content content-description\" data-ab-smc-tab-hide=\"N|N|Y\" data-ab-smc-more=\"More\" data-ab-smc-less=\"Less\" data-ab-smc-height=\"250\" data-ab-smc-tab-override-h=\"N\"\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Name\/Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUV700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eUV-Vis Single Beam Spectrophotometer \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Bandwidth \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2nm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Beam, Grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eWave\u003c\/strong\u003e\u003cstrong\u003elength Range\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e190-1100nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.5 nm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength Repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.2 nm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e 0-200%T, -0.3~3A, 0-9999C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.5%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStray Light\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.1%T \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.0002A\/h @500nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.001 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 x 64 LCD \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeuterium \u0026amp; Tungsten lamp \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCell Holder \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 position 10mm cell holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 220V\/50Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 data-section-id=\"1xvwnkw\" data-start=\"1436\" data-end=\"1443\"\u003e\u003c\/h2\u003e\n\u003ch2 data-section-id=\"1xvwnkw\" data-start=\"1436\" data-end=\"1443\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-section-id=\"lbwddk\" data-start=\"1445\" data-end=\"1519\"\u003e1. What is the UV VIS Single Beam Spectrophotometer Advanced used for?\u003c\/h3\u003e\n\u003cp data-start=\"1520\" data-end=\"1661\"\u003eThe instrument is used for absorbance, transmittance, concentration measurement, and UV-visible spectrum analysis in laboratory applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1e3vmqa\" data-start=\"1663\" data-end=\"1723\"\u003e2. Which industries commonly use this spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"1724\" data-end=\"1909\"\u003eIt is widely used in pharmaceutical laboratories, chemical industries, biotechnology research centers, environmental testing labs, food testing facilities, and educational institutions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mcs7gk\" data-start=\"1911\" data-end=\"1970\"\u003e3. What type of optical system does the instrument use?\u003c\/h3\u003e\n\u003cp data-start=\"1971\" data-end=\"2084\"\u003eThe spectrophotometer uses an advanced single beam optical system for stable and accurate analytical performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"nztnil\" data-start=\"2086\" data-end=\"2142\"\u003e4. Can the instrument perform quantitative analysis?\u003c\/h3\u003e\n\u003cp data-start=\"2143\" data-end=\"2262\"\u003eYes, the system supports quantitative analysis, concentration measurement, and routine laboratory testing applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cle4zg\" data-start=\"2264\" data-end=\"2331\"\u003e5. Is the spectrophotometer suitable for research laboratories?\u003c\/h3\u003e\n\u003cp data-start=\"2332\" data-end=\"2458\"\u003eYes, it is designed for both routine laboratory testing and advanced research applications requiring accurate UV-Vis analysis.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ps7irk\" data-start=\"2460\" data-end=\"2521\"\u003e6. What analytical modes are supported in the instrument?\u003c\/h3\u003e\n\u003cp data-start=\"2522\" data-end=\"2637\"\u003eThe instrument supports absorbance, transmittance, concentration analysis, spectrum scanning, and kinetics testing.\u003c\/p\u003e\n\u003ch3 data-section-id=\"jpqqav\" data-start=\"2639\" data-end=\"2706\"\u003e7. Does the instrument provide accurate wavelength measurement?\u003c\/h3\u003e\n\u003cp data-start=\"2707\" data-end=\"2832\"\u003eYes, the spectrophotometer is designed with high wavelength accuracy and stable photometric performance for reliable results.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1eauail\" data-start=\"2834\" data-end=\"2901\"\u003e8. Why choose an advanced single beam UV-Vis spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"2902\" data-end=\"3069\"\u003eAdvanced single beam spectrophotometers offer reliable analytical accuracy, compact design, cost-effective operation, and easy maintenance for laboratory applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"c9fogg\" data-start=\"3071\" data-end=\"3134\"\u003e9. Is the instrument suitable for educational laboratories?\u003c\/h3\u003e\n\u003cp data-start=\"3135\" data-end=\"3259\"\u003eYes, it is ideal for colleges, universities, and academic laboratories for spectroscopy experiments and analytical training.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ep8s7d\" data-start=\"3261\" data-end=\"3327\"\u003e10. What samples can be analyzed using this spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"3328\" data-end=\"3467\"\u003eThe instrument can analyze pharmaceutical compounds, chemicals, water samples, food products, biological samples, and laboratory solutions.\u003c\/p\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labtical","offers":[{"title":"Default Title","offer_id":49259275223337,"sku":"UV-700","price":94999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/Labtical_UV700_UV-Vis_Single_Beam_Spectrophotometer_jpg.png?v=1777307596"},{"product_id":"advanced-single-beam-uv-vis-spectrophotometer-with-scanning-software","title":"Advanced Single Beam UV-VIS Spectrophotometer With Scanning Software","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Advanced Single Beam Microprocessor UV-VIS Spectrophotometer, Model No. 295, is a sophisticated analytical instrument designed for precision in the measurement of the absorbance and transmittance of light by a sample. It operates in the ultraviolet (UV) and visible (VIS) regions of the electromagnetic spectrum, making it suitable for a wide range of applications in chemical, biological, and environmental research.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSingle Beam Design:\u003c\/strong\u003eUtilizes a single light path through the sample, ensuring simplicity in operation and maintenance. This design is ideal for routine analysis and educational purposes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMicroprocessor Control:\u003c\/strong\u003eIntegrated microprocessor allows for advanced functionality, automation, and improved accuracy. It manages data acquisition, processing, and storage efficiently.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eScanning Software:\u003c\/strong\u003eEquipped with advanced scanning software that facilitates spectral data collection and analysis. The software enables wavelength scanning across the UV-VIS spectrum, providing detailed absorbance spectra.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWavelength Range:\u003c\/strong\u003eCovers a broad wavelength range, typically from 190 nm to 1100 nm, allowing for diverse analytical applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh Resolution and Accuracy:\u003c\/strong\u003eOffers high spectral resolution and precise measurement capabilities. Ideal for both qualitative and quantitative analyses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eUser-Friendly Interface:\u003c\/strong\u003eFeatures an intuitive user interface with easy-to-navigate menus. Often includes a digital display and keypad for convenient operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSample Compartment:\u003c\/strong\u003eDesigned to accommodate standard cuvettes and various sample holders. The compartment is usually temperature-controlled to ensure stable and consistent measurements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eData Connectivity:\u003c\/strong\u003eProvides options for data export and connectivity to external devices, such as computers or printers, via USB or other interfaces. Facilitates easy data management and reporting.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003eConforms to relevant international standards for spectrophotometric measurements, ensuring reliable and reproducible results.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePharmaceutical Analysis:\u003c\/strong\u003eQuantitative analysis of drug compounds and formulations.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Monitoring:\u003c\/strong\u003eDetection and quantification of pollutants in water, air, and soil samples.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eBiological Research:\u003c\/strong\u003eAnalysis of nucleic acids, proteins, and other biomolecules.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eFood and Beverage Industry:\u003c\/strong\u003eQuality control and assurance, including color analysis and concentration measurements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eChemical Analysis:\u003c\/strong\u003eDetermination of chemical concentrations and reaction kinetics.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eSalient Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e* Large LCD screen (128*64) Dots.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e* Can display and save 50 groups of data, 5 groups per screen.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e* Data can be restored after a sudden power cut.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e* Auto-setting Wavelength\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e* Tungsten lamp \u0026amp; deuterium lamp can be turned on\/off individually to extend lifetime.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e* Automatic WL. Calibration and dark current getting. With Scanning\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg decoding=\"async\" class=\"alignnone wp-image-8326 size-full lazyautosizes lazyloaded\" src=\"https:\/\/fitowl.in\/lasany\/wp-content\/uploads\/2023\/03\/li-295-mew-1.png\" alt=\"\" width=\"417\" height=\"377\" data-src=\"https:\/\/fitowl.in\/lasany\/wp-content\/uploads\/2023\/03\/li-295-mew-1.png\" data-srcset=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/li-295-mew-1.png 417w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/li-295-mew-1-300x271.png 300w\" data-sizes=\"auto\" data-eio-rwidth=\"417\" data-eio-rheight=\"377\" sizes=\"417px\" srcset=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/li-295-mew-1.png 417w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/li-295-mew-1-300x271.png 300w\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Lasany","offers":[{"title":"Default Title","offer_id":50448764633385,"sku":"LI-295","price":90000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/li-295.webp?v=1777307885"},{"product_id":"uv-vis-spectrophotometer-with-software","title":"UV-VIS Spectrophotometer with Software","description":"\u003cdiv class=\"woocommerce-product-details__short-description\"\u003e\n\u003cp\u003eUV-VIS Spectrophotometer Single Beam LI-285 Models are designed for reliable continuous operation. It is easy to use, thoroughly reliable and above all low cost.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"woo-multi-currency wmc-price-switcher\" id=\"woocommerce-multi-currency-1\" title=\"Please select your currency\"\u003e\n\u003cdiv class=\"wmc-currency-wrapper\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch4\u003eApplications\u003c\/h4\u003e\n\u003cp\u003e* Medical\/pharmaceutical\u003cbr\u003e* Industry Environmental Monitoring\u003cbr\u003e* Commodity Inspection\u003cbr\u003e* Food Inspection\u003cbr\u003e* Agricultural Chemistry\u003cbr\u003e* Teaching in Colleges \u0026amp; Universities\u003cbr\u003e* Metallurgy\u003cbr\u003e* Geology\u003cbr\u003e* Machine Manufacturing\u003cbr\u003e* Petrochemical Industries\u003cbr\u003e* Water and Wastewater Labs\u003cbr\u003e* Food and Beverage Labs\u003c\/p\u003e\n\u003cp\u003e\u003cimg decoding=\"async\" class=\"alignnone wp-image-8318 size-full lazyautosizes lazyloaded\" src=\"https:\/\/fitowl.in\/lasany\/wp-content\/uploads\/2023\/03\/LI-285-ts.png\" alt=\"\" width=\"739\" height=\"471\" data-src=\"https:\/\/fitowl.in\/lasany\/wp-content\/uploads\/2023\/03\/LI-285-ts.png\" data-srcset=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/LI-285-ts.png 739w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/LI-285-ts-600x382.png 600w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/LI-285-ts-300x191.png 300w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/LI-285-ts-700x446.png 700w\" data-sizes=\"auto\" data-eio-rwidth=\"739\" data-eio-rheight=\"471\" sizes=\"739px\" srcset=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/LI-285-ts.png 739w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/LI-285-ts-600x382.png 600w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/LI-285-ts-300x191.png 300w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/03\/LI-285-ts-700x446.png 700w\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lasany","offers":[{"title":"Default Title","offer_id":50453536080169,"sku":"LI-285","price":70000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/LI-285-e1679852199303.webp?v=1777307357"},{"product_id":"uv-vis-single-beam-spectrophotometer-japanese-technology","title":"UV VIS Single Beam Spectrophotometer (Japanese Technology)","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eUV-300 UV Spectrophotometer is a powerful spectrophotometer based on Japanese technology. It’s Japanese lamps \u0026amp; sensors make the measurement quick \u0026amp; accurate. It’s 22 button key pad makes it easy to use. UV-300 also sports a 128 * 64 display which makes the overall experience much better than a simple LCD display.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eSALIENT FEATURES:\u003c\/strong\u003e\u003cbr\u003e• Imported Lamps: Uses highest quality of imported Deuterium lamp, Tungsten lamp \u0026amp; sensors.\u003cbr\u003e• Low Stray Light: UV-300 is made of high quality components and has perfect design which ensures low stray light.\u003cbr\u003e• Stability \u0026amp; Durability: UV-300 uses die-cast aluminum base which ensures instrument’s stability \u0026amp; durability.\u003cbr\u003e• Multiple Results: UV-300 Can display wavelength, absorption \u0026amp; transmittance. It has a memory of 200 results \u0026amp; 100 standard curves.\u003cbr\u003e• Standard Curve: UV-300 Can set up various standard curves according to customer’s solution and find the concentration of unknown  solutions.\u003cbr\u003e• Auto Setting: User can set wavelength automatically through arrow keys.\u003cbr\u003e• Data Output: UV-300 is equipped with USB port to connect to computer software.\u003cbr\u003e• Wide functionality: Software enables Photometric analysis, Quantitative analysis, Spectral scanning, Kinetics, DNA\/protein analysis,  multi-wavelength test, etc.\u003cbr\u003eThe software is optional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eUV-300\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake\u003c\/td\u003e\n\u003ctd\u003eQuantis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical System\u003c\/td\u003e\n\u003ctd\u003eSingle Beam, Grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e190~1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Bandwidth\u003c\/td\u003e\n\u003ctd\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Setting\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.3 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd\u003e± 0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Holder\u003c\/td\u003e\n\u003ctd\u003e10mm manual 4-cell holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd\u003e-0.3 ~ 3A, 0~200%T, 0~9999C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.05% T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.2% T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e≤0.05%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.002A\/h @500nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Flatness\u003c\/td\u003e\n\u003ctd\u003e±0.002A\/h @500nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 * 64 LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Mode\u003c\/td\u003e\n\u003ctd\u003eT, A, C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eImported Japanese Silicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eImported Japanese D2 \u0026amp; Tungsten Halogen Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eUSB Port \u0026amp; Parallel Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n\u003ctd\u003e700 × 580 × 340 mm \u0026amp; 20 kgs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Quantis","offers":[{"title":"Default Title","offer_id":52382876926249,"sku":"UV-300","price":89999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/UV300-UV-Visible-Spectrophotometer.webp?v=1777056131"},{"product_id":"uv-vis-single-beam-spectrophotometer-manual","title":"UV VIS Single Beam Spectrophotometer Manual I 1 year Warranty","description":"\u003cp data-start=\"24\" data-end=\"660\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003ca data-start=\"28\" data-end=\"215\" rel=\"noopener\" class=\"decorated-link cursor-pointer\"\u003eUV VIS Single Beam Spectrophotometer Manual\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-6d2147a0.svg#304883\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eis a reliable and cost-effective analytical instrument designed for accurate UV and visible spectrum analysis in laboratories, educational institutions, pharmaceutical industries, chemical testing facilities, and research centers. Featuring a single beam optical system with manual wavelength setting, this spectrophotometer provides dependable absorbance, transmittance, and concentration measurements across a wavelength range of 190–1100 nm.\u003c\/p\u003e\n\u003cp data-start=\"662\" data-end=\"1063\"\u003eEquipped with a high-quality grating system, blue light LCD display, silicon photodiode detector, and dual light sources (Deuterium and Tungsten lamps), the instrument ensures stable performance and precise analytical results. The system supports quantitative analysis and kinetics testing through professional PC software, making it suitable for routine laboratory applications and academic research.\u003c\/p\u003e\n\u003cp data-start=\"1065\" data-end=\"1328\"\u003eIts compact structure, low stray light performance, and user-friendly operation make the UV VIS Single Beam Spectrophotometer Manual an ideal choice for laboratories seeking efficient and economical UV-Vis analysis solutions.\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"a-unordered-list a-vertical a-spacing-mini\"\u003e\n\u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003eLABTICAL UV-Vis. Single Beam Spectrophotometer - UV500\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003e70 x 40mm blue light LCD display.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003eQuantitative and Kinetics Test with Professional PC software.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003eAutomatically adjust 0% A and 100% T.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003eStore 50 groups of measuring data.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003e\u003cmeta charset=\"utf-8\"\u003eWavelength Range - 190-1100nm \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eSpectral Bandwidth- 2nm \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eLight Source- Deuterium \u0026amp; Tungsten lamp \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eOptical System Single Beam, \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eGrating -1200 lines\/mm \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eWavelength Accuracy- + 2 nm \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eWavelength Repeatability- + 1nm \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003ePhotometric Accuracy -+ 0.5%T \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003ePhotometric Repeatability- + 0.2%T \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003ePhotometric Mode- T, A, C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003e Stray light -0.15%T @500nm \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eStability- 0.002 A@500nm \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eWavelength Setting- Manual \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eDisplay- 70 x 40mm blue light LCD \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eDetector - Silicon Photodiode \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eCell Holder -4 position 10mm cell holder \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eOutput - RS232 C \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003ePowersupply -AC 220V\/50Hz \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003ePacking Dimension -(LxWxH) 520 x 450 x 320mm \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eGross Weight 10kg\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1xvwnkw\" data-start=\"1335\" data-end=\"1342\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-section-id=\"ox042e\" data-start=\"1344\" data-end=\"1431\"\u003e1. What is the wavelength range of the UV VIS Single Beam Spectrophotometer Manual?\u003c\/h3\u003e\n\u003cp data-start=\"1432\" data-end=\"1582\"\u003eThe instrument operates within a wavelength range of 190–1100 nm, suitable for UV and visible spectrum analysis.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" class=\"flex overflow-hidden rounded-xl text-[9px] font-medium h-4.5 px-2 transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! select-none\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between overflow-hidden\"\u003e\u003cspan class=\"max-w-[15ch] grow truncate overflow-hidden text-center\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ccc1r4\" data-start=\"1584\" data-end=\"1653\"\u003e2. What type of optical system is used in this spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"1654\" data-end=\"1817\"\u003eIt uses a single beam optical system with a 1200 lines\/mm grating for accurate wavelength selection and reliable performance.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" class=\"flex overflow-hidden rounded-xl text-[9px] font-medium h-4.5 px-2 transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! select-none\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between overflow-hidden\"\u003e\u003cspan class=\"max-w-[15ch] grow truncate overflow-hidden text-center\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ugenmt\" data-start=\"1819\" data-end=\"1876\"\u003e3. Does the instrument support quantitative analysis?\u003c\/h3\u003e\n\u003cp data-start=\"1877\" data-end=\"2025\"\u003eYes, the spectrophotometer supports quantitative analysis and kinetics testing using professional PC software.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" class=\"flex overflow-hidden rounded-xl text-[9px] font-medium h-4.5 px-2 transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! select-none\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between overflow-hidden\"\u003e\u003cspan class=\"max-w-[15ch] grow truncate overflow-hidden text-center\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"z04rss\" data-start=\"2027\" data-end=\"2071\"\u003e4. What measurement modes are available?\u003c\/h3\u003e\n\u003cp data-start=\"2072\" data-end=\"2209\"\u003eThe instrument supports Transmittance (T), Absorbance (A), and Concentration (C) measurement modes.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" class=\"flex overflow-hidden rounded-xl text-[9px] font-medium h-4.5 px-2 transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! select-none\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between overflow-hidden\"\u003e\u003cspan class=\"max-w-[15ch] grow truncate overflow-hidden text-center\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1s2aqvq\" data-start=\"2211\" data-end=\"2271\"\u003e5. What type of display does the spectrophotometer have?\u003c\/h3\u003e\n\u003cp data-start=\"2272\" data-end=\"2393\"\u003eIt features a 70 × 40 mm blue light LCD display for clear and convenient operation.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" class=\"flex overflow-hidden rounded-xl text-[9px] font-medium h-4.5 px-2 transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! select-none\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between overflow-hidden\"\u003e\u003cspan class=\"max-w-[15ch] grow truncate overflow-hidden text-center\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"l614l0\" data-start=\"2395\" data-end=\"2462\"\u003e6. Which industries commonly use this UV-Vis spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"2463\" data-end=\"2689\"\u003eThe instrument is widely used in pharmaceutical laboratories, educational institutions, environmental testing labs, chemical industries, food testing laboratories, and research facilities.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.labmart.in\/collections\/single-beam-spectrophotometer?srsltid=AfmBOopowSLI2ytOEUItAIfzn5lCHC5pQJ3mcfZbHiqrxU-jJ47I_yXR\u0026amp;utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.labmart.in\/collections\/single-beam-spectrophotometer?srsltid=AfmBOopowSLI2ytOEUItAIfzn5lCHC5pQJ3mcfZbHiqrxU-jJ47I_yXR\u0026amp;utm_source=chatgpt.com\" class=\"flex overflow-hidden rounded-xl text-[9px] font-medium h-4.5 px-2 transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! select-none\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between\"\u003e\u003cspan class=\"max-w-[15ch] grow truncate overflow-hidden text-center\"\u003eLabmart.in\u003c\/span\u003e\u003cspan class=\"-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]\"\u003e+1\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"qx91gg\" data-start=\"2691\" data-end=\"2744\"\u003e7. What light sources are used in the instrument?\u003c\/h3\u003e\n\u003cp data-start=\"2745\" data-end=\"2873\"\u003eThe spectrophotometer uses Deuterium and Tungsten lamps for UV and visible light analysis.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" class=\"flex overflow-hidden rounded-xl text-[9px] font-medium h-4.5 px-2 transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! select-none\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between overflow-hidden\"\u003e\u003cspan class=\"max-w-[15ch] grow truncate overflow-hidden text-center\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"i3h7cs\" data-start=\"2875\" data-end=\"2941\"\u003e8. Is the instrument suitable for routine laboratory analysis?\u003c\/h3\u003e\n\u003cp data-start=\"2942\" data-end=\"3118\"\u003eYes, its stable optical system, compact design, and easy operation make it ideal for routine laboratory testing and academic applications.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.labmart.in\/blogs\/news\/double-beam-vs-single-beam-spectrophotometer-a-detailed-comparison-for-laboratories?srsltid=AfmBOopAhG__4IwKNDt-vu32NSm57nx4bRq6Y89vgzcNIoXev5Fen44O\u0026amp;utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.labmart.in\/blogs\/news\/double-beam-vs-single-beam-spectrophotometer-a-detailed-comparison-for-laboratories?srsltid=AfmBOopAhG__4IwKNDt-vu32NSm57nx4bRq6Y89vgzcNIoXev5Fen44O\u0026amp;utm_source=chatgpt.com\" class=\"flex overflow-hidden rounded-xl text-[9px] font-medium h-4.5 px-2 transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! select-none\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between overflow-hidden\"\u003e\u003cspan class=\"max-w-[15ch] grow truncate overflow-hidden text-center\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"wszlxl\" data-start=\"3120\" data-end=\"3175\"\u003e9. What detector is used in this spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"3176\" data-end=\"3304\"\u003eThe instrument uses a silicon photodiode detector for accurate photometric measurements.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center select-none relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003ca href=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" rel=\"noopener\" alt=\"https:\/\/www.labmart.in\/products\/uv-vis-single-beam-spectrophotometer-manual?srsltid=AfmBOor4JHBpxWBC1cjsl9CM8rjh_ysNpH8fQNakTy9Tk32n0-KKr8An\u0026amp;utm_source=chatgpt.com\" class=\"flex overflow-hidden rounded-xl text-[9px] font-medium h-4.5 px-2 transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! select-none\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between overflow-hidden\"\u003e\u003cspan class=\"max-w-[15ch] grow truncate overflow-hidden text-center\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"lei10u\" data-start=\"3306\" data-end=\"3371\"\u003e10. Why choose a manual single beam UV-Vis spectrophotometer?\u003c\/h3\u003e\n\u003cp data-start=\"3372\" data-end=\"3574\"\u003eManual single beam spectrophotometers are economical, easy to maintain, simple to operate, and suitable for standard laboratory analysis and educational purposes.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Labtical","offers":[{"title":"Default Title","offer_id":52382908711209,"sku":"UV-500","price":59999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/labtical-uv500-uv-vis-single-beam-spectrophotometer-500x500.webp?v=1778594285"},{"product_id":"labmart-luv1100t-touchscreen-uv-vis-spectrophotometer","title":"LUV1100T Touchscreen UV-Vis Spectrophotometer – 190–1100 nm, 2 nm Bandwidth, 7\" Touch Screen, 32 GB Memory, Free Onsite Installation","description":"\u003cp\u003eThe LABMAN LUV1100T is a touchscreen UV-Vis spectrophotometer covering 190–1100 nm with a 2 nm bandwidth. It has a 7\" touch screen, 32 GB memory and an internal computer for calibration curves, spectral scanning, kinetics and DNA\/protein tests, and exports data to a pen drive or an HP DeskJet printer.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull wavelength scanning 190–1100 nm covering UV, visible and near IR\u003c\/li\u003e\n\u003cli\u003eSingle beam optical system with dual detector\u003c\/li\u003e\n\u003cli\u003e7\" large touch screen with built-in 32 GB memory\u003c\/li\u003e\n\u003cli\u003eFully sealed structure with SiO₂-protected mirrors to reduce stray light from dust and corrosive gas\u003c\/li\u003e\n\u003cli\u003eBuilt-in data analysis: calibration curve, photometric and quantitative measurement, spectral scanning, kinetics, DNA\/protein test, multi-wavelength analysis\u003c\/li\u003e\n\u003cli\u003eTungsten and deuterium lamps with usage-hour monitoring; automatic power-on self test\u003c\/li\u003e\n\u003cli\u003eData export to a pen drive; direct printing to an HP DeskJet 2723 printer; 3D graph display\u003c\/li\u003e\n\u003cli\u003ePC software follows GLP and GMP standards (user management, logging, data tracking, mostly as per 21 CFR Part 11)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLUV1100T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake\u003c\/td\u003e\n\u003ctd\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical system\u003c\/td\u003e\n\u003ctd\u003eSingle beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength range\u003c\/td\u003e\n\u003ctd\u003e190–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003e2.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric range\u003c\/td\u003e\n\u003ctd\u003e0–200%T, –0.3 to 3.0 A, 0–9999 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2%T (0–100%T), ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric repeatability\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1%T (0–100%T), 0.001 Abs (0–0.5 Abs), 0.002 Abs (0.5–1.0 Abs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.001 A\/h at 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray light\u003c\/td\u003e\n\u003ctd\u003e0.05%T at 220 nm, 360 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell holder\u003c\/td\u003e\n\u003ctd\u003e10 mm each, sample and reference cuvette holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eTungsten lamp and deuterium lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7\" touch screen (800 × 480) HD TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eSilicon photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl mode\u003c\/td\u003e\n\u003ctd\u003eStand-alone system \/ PC software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline flatness\u003c\/td\u003e\n\u003ctd\u003e±0.001 A\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData output\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eAC 220 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking dimension (L×W×H)\u003c\/td\u003e\n\u003ctd\u003e645 × 550 × 405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross weight\u003c\/td\u003e\n\u003ctd\u003e25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSN code\u003c\/td\u003e\n\u003ctd\u003e90273020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cp\u003eMain instrument, power cable, 10 mm quartz cuvette, glass cuvette, software pen drive, dongle, dust cover, USB cable, instruction manual, test certificate.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4\u003eWhat wavelength range does the LUV1100T cover?\u003c\/h4\u003e\n\u003cp\u003e190–1100 nm, covering UV, visible and near IR.\u003c\/p\u003e\n\u003ch4\u003eIs it single beam or double beam?\u003c\/h4\u003e\n\u003cp\u003eSingle beam. The LUV2000T series is the double beam range.\u003c\/p\u003e\n\u003ch4\u003eWhat can it do without a computer?\u003c\/h4\u003e\n\u003cp\u003ePhotometric and quantitative measurement, calibration curves, spectral scanning, kinetics, DNA\/protein tests and multi-wavelength analysis on its own touch screen.\u003c\/p\u003e\n\u003ch4\u003eHow do I get the data out?\u003c\/h4\u003e\n\u003cp\u003eExport to a pen drive by USB, or print directly to an HP DeskJet 2723.\u003c\/p\u003e\n\u003ch4\u003eWhat lamps does it use?\u003c\/h4\u003e\n\u003cp\u003eA tungsten lamp and a deuterium lamp, with usage-hour monitoring.\u003c\/p\u003e\n\u003ch4\u003eWhat power supply does it need?\u003c\/h4\u003e\n\u003cp\u003eAC 220 V, 50\/60 Hz.\u003c\/p\u003e\n\u003ch4\u003eWhat is supplied with it?\u003c\/h4\u003e\n\u003cp\u003eMain instrument, power cable, 10 mm quartz cuvette, glass cuvette, software pen drive, dongle, dust cover, USB cable, instruction manual, test certificate.\u003c\/p\u003e\n\u003ch4\u003eWhat are the packing size and weight?\u003c\/h4\u003e\n\u003cp\u003e645 × 550 × 405 mm (L×W×H as per catalogue), gross weight 25 kg.\u003c\/p\u003e\n\u003ch4\u003eCan I get a GST invoice and a bulk or institutional quotation?\u003c\/h4\u003e\n\u003cp\u003eYes. Labmart (Chemlab Equipment) supplies against a GST invoice and provides quotations for colleges, hospitals, pharma companies and government labs, including bulk and tender requirements. Contact us with your requirement for a formal quotation.\u003c\/p\u003e\n\u003ch4\u003eWhat is the warranty and delivery time?\u003c\/h4\u003e\n\u003cp\u003eLABMAN instruments supplied by Labmart carry a standard 13-month warranty. Delivery time depends on your location and stock, so please contact Labmart for a delivery estimate.\u003c\/p\u003e\n","brand":"Labman","offers":[{"title":"Default Title","offer_id":52642943009065,"sku":"LUV1100T","price":197999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/rs_w_720_cg_true_1.webp?v=1770941284"},{"product_id":"single-beam-uv-vis-spectrophotometer-lmspuv1200","title":"LMSPUV1200 Single Beam UV-Vis Spectrophotometer – 190–1100 nm, 2 nm Bandwidth – Free Onsite Installation","description":"\u003cp\u003eThe LABMAN LMSPUV1200 is a microprocessor-controlled single beam UV-Vis spectrophotometer covering 190–1100 nm with a 2 nm bandwidth, 1200 lines\/mm grating, deuterium and tungsten halogen lamps and a USB port for PC software (spectrum scanning, kinetics and multi-wavelength tests).\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFree onsite installation\u003c\/li\u003e\n\u003cli\u003eNumerical keys; automatic wavelength setting through arrow keys\u003c\/li\u003e\n\u003cli\u003eRigid die-cast aluminium optical base for stability\u003c\/li\u003e\n\u003cli\u003eStandard curve function to find the concentration of unknown solutions\u003c\/li\u003e\n\u003cli\u003eImported flanged deuterium lamp with low stray light; tungsten and deuterium lamps can be switched off separately to extend lamp life\u003c\/li\u003e\n\u003cli\u003eUSB port to connect a PC for spectrum scanning, kinetics and multi-wavelength testing\u003c\/li\u003e\n\u003cli\u003eData restored after a sudden power cut\u003c\/li\u003e\n\u003cli\u003eLarge sample compartment; accepts 5–100 mm path-length cuvettes with optional holders\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLMSPUV1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake\u003c\/td\u003e\n\u003ctd\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength range\u003c\/td\u003e\n\u003ctd\u003e190–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical system\u003c\/td\u003e\n\u003ctd\u003eSingle beam, grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength setting\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.2 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric range\u003c\/td\u003e\n\u003ctd\u003e−0.3 to 3 A, 0–200 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.002 A\/h @ 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline flatness\u003c\/td\u003e\n\u003ctd\u003e±0.002 A\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray light\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.05 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData output\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter port\u003c\/td\u003e\n\u003ctd\u003eParallel port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell holder\u003c\/td\u003e\n\u003ctd\u003e10 mm, 4-position cuvette holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eD2 lamp \u0026amp; tungsten halogen (W) lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eSilicon photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eAC 220 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking dimension (L×W×H)\u003c\/td\u003e\n\u003ctd\u003e640 × 550 × 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross weight\u003c\/td\u003e\n\u003ctd\u003e24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSN code\u003c\/td\u003e\n\u003ctd\u003e90273020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cp\u003eMain instrument, 10 mm glass cuvette (4 pcs), 10 mm quartz cuvette (2 pcs), dongle, pen drive, power cable, dust cover, instruction manual, test certificate.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4\u003eWhat wavelength range does the LMSPUV1200 cover?\u003c\/h4\u003e\n\u003cp\u003e190–1100 nm with 2 nm bandwidth and ±0.8 nm accuracy.\u003c\/p\u003e\n\u003ch4\u003eWhich lamps does it use?\u003c\/h4\u003e\n\u003cp\u003eA deuterium (D2) lamp for UV and a tungsten halogen lamp for visible, which can be turned on or off individually.\u003c\/p\u003e\n\u003ch4\u003eCan I use longer path-length cuvettes?\u003c\/h4\u003e\n\u003cp\u003eYes, 5–100 mm path-length cuvettes with optional holders; the standard holder is a 4-position 10 mm holder.\u003c\/p\u003e\n\u003ch4\u003eWhat accessories are optional?\u003c\/h4\u003e\n\u003cp\u003ePeltier \/ sipper system and a multi-cell holder (up to 100 mm).\u003c\/p\u003e\n\u003ch4\u003eCan it connect to a PC?\u003c\/h4\u003e\n\u003cp\u003eYes, through the USB port for spectrum scanning, kinetics and multi-wavelength testing.\u003c\/p\u003e\n\u003ch4\u003eWhat power supply does it need?\u003c\/h4\u003e\n\u003cp\u003eAC 220 V, 50\/60 Hz.\u003c\/p\u003e\n\u003ch4\u003eWhat is supplied with it?\u003c\/h4\u003e\n\u003cp\u003eMain instrument, 10 mm glass cuvette (4 pcs), 10 mm quartz cuvette (2 pcs), dongle, pen drive, power cable, dust cover, instruction manual, test certificate.\u003c\/p\u003e\n\u003ch4\u003eWhat are the packing size and weight?\u003c\/h4\u003e\n\u003cp\u003e640 × 550 × 400 mm (L×W×H as per catalogue), gross weight 24 kg.\u003c\/p\u003e\n\u003ch4\u003eCan I get a GST invoice and a bulk or institutional quotation?\u003c\/h4\u003e\n\u003cp\u003eYes. Labmart (Chemlab Equipment) supplies against a GST invoice and provides quotations for colleges, hospitals, pharma companies and government labs, including bulk and tender requirements. Contact us with your requirement for a formal quotation.\u003c\/p\u003e\n\u003ch4\u003eWhat is the warranty and delivery time?\u003c\/h4\u003e\n\u003cp\u003eLABMAN instruments supplied by Labmart carry a standard 13-month warranty. Delivery time depends on your location and stock, so please contact Labmart for a delivery estimate.\u003c\/p\u003e\n","brand":"Labman","offers":[{"title":"Default Title","offer_id":52643017064745,"sku":"LMSPUV1200","price":134999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/rs_w_720_cg_true_3.webp?v=1777055590"},{"product_id":"single-beam-uv-vis-spectrophotometer-lmspuv1000b","title":"LMSPUV1000B Single Beam UV-Vis Spectrophotometer – 190–1000 nm, 2 nm Bandwidth – Free Onsite Installation","description":"\u003cp\u003eThe LABMAN LMSPUV1000B is a basic single beam UV-Vis spectrophotometer covering 190–1000 nm with 2 nm bandwidth, a 1200 lines\/mm grating and deuterium and tungsten halogen lamps. It stores up to 200 results, shows 5 results per screen and connects to a PC by USB for spectrum scanning, kinetics and multi-wavelength tests.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFree onsite installation\u003c\/li\u003e\n\u003cli\u003eLow stray light from high quality components and a rigid structure\u003c\/li\u003e\n\u003cli\u003eRigid die-cast aluminium optical base for stability and durability\u003c\/li\u003e\n\u003cli\u003eStandard curve function for concentration of unknown solutions\u003c\/li\u003e\n\u003cli\u003eDisplays wavelength, absorbance and transmittance, 5 results per screen; memory of up to 200 results\u003c\/li\u003e\n\u003cli\u003eAutomatic wavelength setting through arrow keys\u003c\/li\u003e\n\u003cli\u003eUSB port to a PC for spectrum scanning, kinetics and multi-wavelength testing\u003c\/li\u003e\n\u003cli\u003eData restored after a sudden power cut\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLMSPUV1000B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake\u003c\/td\u003e\n\u003ctd\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical system\u003c\/td\u003e\n\u003ctd\u003eSingle beam, grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength range\u003c\/td\u003e\n\u003ctd\u003e190–1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength setting\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.3 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric range\u003c\/td\u003e\n\u003ctd\u003e−0.3 to 3 A, 0–200 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray light\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.3 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.002 A\/h @ 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eSilicon photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard cell holder\u003c\/td\u003e\n\u003ctd\u003e4-position 10 mm cell holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eD2 lamp \u0026amp; tungsten halogen (W) lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eUSB port \u0026amp; parallel port (printer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eAC 220 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking dimension (L×W×H)\u003c\/td\u003e\n\u003ctd\u003e640 × 550 × 395 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross weight\u003c\/td\u003e\n\u003ctd\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSN code\u003c\/td\u003e\n\u003ctd\u003e90273020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cp\u003eMain instrument, 10 mm glass cuvette (4 pcs), 10 mm quartz cuvette (2 pcs), dongle, pen drive, power cable, dust cover, instruction manual, test certificate.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4\u003eWhat wavelength range does the LMSPUV1000B cover?\u003c\/h4\u003e\n\u003cp\u003e190–1000 nm with 2 nm bandwidth and ±1 nm wavelength accuracy.\u003c\/p\u003e\n\u003ch4\u003eHow is it different from the LMSPUV1200?\u003c\/h4\u003e\n\u003cp\u003eLMSPUV1000B is the basic model (190–1000 nm, ±1 nm, stray light \u0026lt; 0.3 %T); LMSPUV1200 covers 190–1100 nm with ±0.8 nm and \u0026lt; 0.05 %T.\u003c\/p\u003e\n\u003ch4\u003eHow many results can it store?\u003c\/h4\u003e\n\u003cp\u003eUp to 200 results, with 5 results shown per screen.\u003c\/p\u003e\n\u003ch4\u003eWhat accessories are optional?\u003c\/h4\u003e\n\u003cp\u003ePeltier \/ sipper system and a multi-cell holder (up to 100 mm).\u003c\/p\u003e\n\u003ch4\u003eCan it connect to a PC?\u003c\/h4\u003e\n\u003cp\u003eYes, through the USB port; a parallel port is available for a printer.\u003c\/p\u003e\n\u003ch4\u003eWhat power supply does it need?\u003c\/h4\u003e\n\u003cp\u003eAC 220 V, 50\/60 Hz.\u003c\/p\u003e\n\u003ch4\u003eWhat is supplied with it?\u003c\/h4\u003e\n\u003cp\u003eMain instrument, 10 mm glass cuvette (4 pcs), 10 mm quartz cuvette (2 pcs), dongle, pen drive, power cable, dust cover, instruction manual, test certificate.\u003c\/p\u003e\n\u003ch4\u003eWhat are the packing size and weight?\u003c\/h4\u003e\n\u003cp\u003e640 × 550 × 395 mm (L×W×H as per catalogue), gross weight 22 kg.\u003c\/p\u003e\n\u003ch4\u003eCan I get a GST invoice and a bulk or institutional quotation?\u003c\/h4\u003e\n\u003cp\u003eYes. Labmart (Chemlab Equipment) supplies against a GST invoice and provides quotations for colleges, hospitals, pharma companies and government labs, including bulk and tender requirements. Contact us with your requirement for a formal quotation.\u003c\/p\u003e\n\u003ch4\u003eWhat is the warranty and delivery time?\u003c\/h4\u003e\n\u003cp\u003eLABMAN instruments supplied by Labmart carry a standard 13-month warranty. Delivery time depends on your location and stock, so please contact Labmart for a delivery estimate.\u003c\/p\u003e\n","brand":"Labman","offers":[{"title":"Default Title","offer_id":52655552626985,"sku":"LMSPUV1000B","price":110000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/rs_w_720_cg_true_9.webp?v=1777055661"},{"product_id":"uv-vis-single-beam-spectrophotmeter-economic-model","title":"UV-VIS Single Beam Spectrophotometer, Economic Model,195-1020nm wavelength","description":"\u003cdiv class=\"woocommerce-tabs wc-tabs-wrapper\"\u003e\n\u003cdiv id=\"tab-description\" class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--description panel entry-content wc-tab\" role=\"tabpanel\" aria-labelledby=\"tab-title-description\"\u003e\n\u003cp data-end=\"722\" data-start=\"175\"\u003eThe \u003cstrong data-end=\"214\" data-start=\"179\"\u003eUV Vis Spectrophotometer UV-105\u003c\/strong\u003e is a high-performance analytical instrument engineered to deliver precise and reliable measurement of light absorbance and transmittance across both the \u003cstrong data-end=\"388\" data-start=\"368\"\u003eultraviolet (UV)\u003c\/strong\u003e and \u003cstrong data-end=\"410\" data-start=\"393\"\u003evisible (Vis)\u003c\/strong\u003e regions of the electromagnetic spectrum. Designed to meet the needs of modern laboratories in education, research, environmental testing, pharmaceuticals, biotechnology, and industrial quality control, the UV-100 combines \u003cstrong data-end=\"645\" data-start=\"633\"\u003eaccuracy\u003c\/strong\u003e, \u003cstrong data-end=\"661\" data-start=\"647\"\u003esimplicity\u003c\/strong\u003e, and \u003cstrong data-end=\"682\" data-start=\"667\"\u003eversatility\u003c\/strong\u003e in a compact and user-friendly package.\u003c\/p\u003e\n\u003cp data-end=\"1787\" data-start=\"1282\"\u003eEngineered with the user in mind, the UV-105 features an intuitive interface with a high-resolution digital display and easy-to-navigate controls.\u003c\/p\u003e\n\u003cp data-end=\"3222\" data-start=\"2796\"\u003eDurability and maintenance convenience are hallmarks of the UV-105 design. Long-life lamps and accessible optical components make routine maintenance and service straightforward, keeping total cost of ownership low and maximizing instrument uptime.\u003c\/p\u003e\n\u003cp\u003eSALIENT FEATURES:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely easy to set up \u0026amp; simple to use\u003c\/li\u003e\n\u003cli\u003eMonochromator with a holographic flashing grating\u003c\/li\u003e\n\u003cli\u003eHigh wavelength precision, good monochromatic and low stray light\u003c\/li\u003e\n\u003cli\u003eDirect read out of Absorption(ABS), Transmittance(%T), Concentration(C) \u0026amp; concentration setting function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"woocommerce-tabs wc-tabs-wrapper\"\u003e\n\u003cdiv id=\"tab-specifications\" class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--specifications panel entry-content wc-tab\" role=\"tabpanel\" aria-labelledby=\"tab-title-specifications\"\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUV-105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake\u003c\/td\u003e\n\u003ctd\u003eGalaxy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical System\u003c\/td\u003e\n\u003ctd\u003eCT Single Beam, Grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e195 ~ 1020 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Bandwidth\u003c\/td\u003e\n\u003ctd\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 2 nm\u003c\/td\u003e\n\u003ctd\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd\u003e1 nm\u003c\/td\u003e\n\u003ctd\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.5%T\u003c\/td\u003e\n\u003ctd\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd\u003e0.2%T\u003c\/td\u003e\n\u003ctd\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd\u003e0 – 200%T\u003c\/td\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e≤ 0.3%T @ 340 nm\u003c\/td\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e± 0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay \u0026amp;amp; Photometric Mode\u003c\/td\u003e\n\u003ctd\u003e4 Digit LCD \u0026amp; Mode: T, A, C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eDeuterium \u0026amp; Tungsten Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 220V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n\u003ctd\u003e450 × 520 × 320 mm \u0026amp; 12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSTANDARD ACCESSORIES:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGlass Cell 10mm\u003c\/li\u003e\n\u003cli\u003eQuartz Cell 10mm\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eInstruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"188\" data-start=\"151\" data-section-id=\"1idaiwr\"\u003e❓ Frequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3 data-end=\"258\" data-start=\"190\" data-section-id=\"1cp3v8o\"\u003e1. What is the wavelength range of the UV-105 spectrophotometer?\u003c\/h3\u003e\n\u003cp data-end=\"461\" data-start=\"259\"\u003eThe UV-105 operates in a wavelength range of \u003cstrong data-end=\"325\" data-start=\"304\"\u003e195 nm to 1020 nm\u003c\/strong\u003e, making it suitable for both UV and visible light analysis across a wide range of applications. \u003cbutton class=\"ms-1 relative flex h-[25px] select-none items-center justify-center gap-1 rounded-xl px-2 text-[10px] leading-[13px] corner-superellipse\/1.1 text-token-text-secondary! hover:text-token-text-primary! hover:bg-token-bg-secondary dark:bg-token-main-surface-secondary dark:hover:bg-token-bg-secondary bg-[#f4f4f4]\" type=\"button\"\u003e\u003c\/button\u003e\u003c\/p\u003e\n\u003cp class=\"not-prose mt-0! mb-0! flex-auto truncate\"\u003e \u003c\/p\u003e\n\u003chr data-end=\"466\" data-start=\"463\"\u003e\n\u003ch3 data-end=\"528\" data-start=\"468\" data-section-id=\"b82s56\"\u003e2. What type of optical system does this instrument use?\u003c\/h3\u003e\n\u003cp data-end=\"704\" data-start=\"529\"\u003eIt uses a \u003cstrong data-end=\"598\" data-start=\"539\"\u003esingle beam optical system with a 1200 lines\/mm grating\u003c\/strong\u003e, ensuring accurate wavelength selection and reliable performance. \u003cbutton class=\"ms-1 relative flex h-[25px] select-none items-center justify-center gap-1 rounded-xl px-2 text-[10px] leading-[13px] corner-superellipse\/1.1 text-token-text-secondary! hover:text-token-text-primary! hover:bg-token-bg-secondary dark:bg-token-main-surface-secondary dark:hover:bg-token-bg-secondary bg-[#f4f4f4]\" type=\"button\"\u003e\u003c\/button\u003e\u003c\/p\u003e\n\u003cp class=\"not-prose mt-0! mb-0! flex-auto truncate\"\u003e \u003c\/p\u003e\n\u003chr data-end=\"709\" data-start=\"706\"\u003e\n\u003ch3 data-end=\"755\" data-start=\"711\" data-section-id=\"1tr195n\"\u003e3. What measurement modes are available?\u003c\/h3\u003e\n\u003cp data-end=\"807\" data-start=\"756\"\u003eThe instrument supports multiple photometric modes:\u003c\/p\u003e\n\u003cul data-end=\"879\" data-start=\"808\"\u003e\n\u003cli data-end=\"828\" data-start=\"808\" data-section-id=\"15fjbim\"\u003e\n\u003cp data-end=\"828\" data-start=\"810\"\u003e\u003cstrong data-end=\"828\" data-start=\"810\"\u003eAbsorbance (A)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"853\" data-start=\"829\" data-section-id=\"e2h1nz\"\u003e\n\u003cp data-end=\"853\" data-start=\"831\"\u003e\u003cstrong data-end=\"853\" data-start=\"831\"\u003eTransmittance (%T)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"879\" data-start=\"854\" data-section-id=\"gqcivv\"\u003e\n\u003cp data-end=\"879\" data-start=\"856\"\u003e\u003cstrong data-end=\"877\" data-start=\"856\"\u003eConcentration (C)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"991\" data-start=\"881\"\u003eThis allows flexibility for different laboratory testing requirements. \u003cbutton class=\"ms-1 relative flex h-[25px] select-none items-center justify-center gap-1 rounded-xl px-2 text-[10px] leading-[13px] corner-superellipse\/1.1 text-token-text-secondary! hover:text-token-text-primary! hover:bg-token-bg-secondary dark:bg-token-main-surface-secondary dark:hover:bg-token-bg-secondary bg-[#f4f4f4]\" type=\"button\"\u003e\u003c\/button\u003e\u003c\/p\u003e\n\u003cp class=\"not-prose mt-0! mb-0! flex-auto truncate\"\u003e \u003c\/p\u003e\n\u003chr data-end=\"996\" data-start=\"993\"\u003e\n\u003ch3 data-end=\"1047\" data-start=\"998\" data-section-id=\"1n194qd\"\u003e4. How accurate and stable is the instrument?\u003c\/h3\u003e\n\u003cul data-end=\"1161\" data-start=\"1048\"\u003e\n\u003cli data-end=\"1082\" data-start=\"1048\" data-section-id=\"212g3a\"\u003e\n\u003cp data-end=\"1082\" data-start=\"1050\"\u003eWavelength accuracy: \u003cstrong data-end=\"1080\" data-start=\"1071\"\u003e±2 nm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1119\" data-start=\"1083\" data-section-id=\"1u08yh8\"\u003e\n\u003cp data-end=\"1119\" data-start=\"1085\"\u003ePhotometric accuracy: \u003cstrong data-end=\"1117\" data-start=\"1107\"\u003e±0.5%T\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1161\" data-start=\"1120\" data-section-id=\"9bkh0y\"\u003e\n\u003cp data-end=\"1161\" data-start=\"1122\"\u003eStability: \u003cstrong data-end=\"1159\" data-start=\"1133\"\u003e±0.002 A\/hour @ 500 nm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1291\" data-start=\"1163\"\u003eThese specifications ensure \u003cstrong data-end=\"1225\" data-start=\"1191\"\u003econsistent and precise results\u003c\/strong\u003e for routine lab analysis. \u003cbutton class=\"ms-1 relative flex h-[25px] select-none items-center justify-center gap-1 rounded-xl px-2 text-[10px] leading-[13px] corner-superellipse\/1.1 text-token-text-secondary! hover:text-token-text-primary! hover:bg-token-bg-secondary dark:bg-token-main-surface-secondary dark:hover:bg-token-bg-secondary bg-[#f4f4f4]\" type=\"button\"\u003e\u003c\/button\u003e\u003c\/p\u003e\n\u003cp class=\"not-prose mt-0! mb-0! flex-auto truncate\"\u003e \u003c\/p\u003e\n\u003chr data-end=\"1296\" data-start=\"1293\"\u003e\n\u003ch3 data-end=\"1359\" data-start=\"1298\" data-section-id=\"11qqvb7\"\u003e5. What light sources are used in this spectrophotometer?\u003c\/h3\u003e\n\u003cp data-end=\"1376\" data-start=\"1360\"\u003eThe UV-105 uses:\u003c\/p\u003e\n\u003cul data-end=\"1456\" data-start=\"1377\"\u003e\n\u003cli data-end=\"1414\" data-start=\"1377\" data-section-id=\"c3u5qw\"\u003e\n\u003cp data-end=\"1414\" data-start=\"1379\"\u003e\u003cstrong data-end=\"1397\" data-start=\"1379\"\u003eDeuterium lamp\u003c\/strong\u003e (for UV range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1456\" data-start=\"1415\" data-section-id=\"l0khj\"\u003e\n\u003cp data-end=\"1456\" data-start=\"1417\"\u003e\u003cstrong data-end=\"1434\" data-start=\"1417\"\u003eTungsten lamp\u003c\/strong\u003e (for visible range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1584\" data-start=\"1458\"\u003eThis dual light source enables accurate measurements across the full wavelength range. \u003cbutton class=\"ms-1 relative flex h-[25px] select-none items-center justify-center gap-1 rounded-xl px-2 text-[10px] leading-[13px] corner-superellipse\/1.1 text-token-text-secondary! hover:text-token-text-primary! hover:bg-token-bg-secondary dark:bg-token-main-surface-secondary dark:hover:bg-token-bg-secondary bg-[#f4f4f4]\" type=\"button\"\u003e\u003c\/button\u003e\u003c\/p\u003e\n\u003chr data-end=\"1589\" data-start=\"1586\"\u003e\n\u003ch3 data-end=\"1648\" data-start=\"1591\" data-section-id=\"1t5q5m5\"\u003e6. What accessories are included with the instrument?\u003c\/h3\u003e\n\u003cp data-end=\"1678\" data-start=\"1649\"\u003eStandard accessories include:\u003c\/p\u003e\n\u003cul data-end=\"1763\" data-start=\"1679\"\u003e\n\u003cli data-end=\"1701\" data-start=\"1679\" data-section-id=\"q4iv9g\"\u003e\n\u003cp data-end=\"1701\" data-start=\"1681\"\u003eGlass cell (10 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1725\" data-start=\"1702\" data-section-id=\"1o8fbav\"\u003e\n\u003cp data-end=\"1725\" data-start=\"1704\"\u003eQuartz cell (10 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1740\" data-start=\"1726\" data-section-id=\"18cmsjx\"\u003e\n\u003cp data-end=\"1740\" data-start=\"1728\"\u003ePower cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1763\" data-start=\"1741\" data-section-id=\"1578cq\"\u003e\n\u003cp data-end=\"1763\" data-start=\"1743\"\u003eInstruction manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Spectrix","offers":[{"title":"Default Title","offer_id":52980718436649,"sku":"UV-105","price":59999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/uv-visible-spectrometer.jpg?v=1777054813"},{"product_id":"dlab-sp-uv1000-uv-vis-spectrophotometer","title":"DLAB SP-UV1000 UV-Vis Spectrophotometer, 200–1000 nm, 4 nm","description":"\u003cp\u003eThe DLAB SP-UV1000 is a single-beam UV-Vis spectrophotometer (200–1000 nm, tungsten and deuterium lamps) for absorbance and transmittance, quantitative analysis, kinetics and DNA\/protein detection in medicine, clinical testing, biochemistry, petrochemical, environmental and food testing, and for teaching.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProfessional, compact design with an easy-to-operate interface\u003c\/li\u003e\n\u003cli\u003eStores up to 128 sets of standard curves and 4000 test results; data saved in real time to prevent loss on power failure\u003c\/li\u003e\n\u003cli\u003eAutomatic wavelength calibration and dark-current correction\u003c\/li\u003e\n\u003cli\u003eAutomatically switches the light source and turns off the unused lamp to extend lamp life\u003c\/li\u003e\n\u003cli\u003ePhotometry, quantitation, kinetics, multi-wavelength and time scanning, DNA\/protein detection\u003c\/li\u003e\n\u003cli\u003eUSB and print ports; PC software for data handling\u003c\/li\u003e\n\u003cli\u003eOptional accessories: automatic cell holder, film holder, constant-temperature cell holder, reflectivity accessory, variable-path sample holder\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTungsten and deuterium lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.3–3.0 A, 0–200 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.003 A\/0.5 A, ±0.006 A\/1.0 A, ±0.5 %T\/100 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.0015 A\/0.5 A, ≤0.003 A\/1.0 A, ≤0.25 %T\/100 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.002 A\/h at 500 nm (after 2 h preheat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStray light\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.2 %T\/360 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample room\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-connected cell, 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB port, print port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\/220 V AC, 50\/60 Hz, 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L×W×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e490 × 360 × 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelivery period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eSupplied with\u003c\/h3\u003e\u003cp\u003eMain unit with 4 glass square cuvettes and 2 quartz square cuvettes (as listed in the DLAB price list); other contents to confirm.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDelivery Period – 10 days.\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the DLAB SP-UV1000 used for?\u003c\/h4\u003e\u003cp\u003eThe DLAB SP-UV1000 is a single-beam UV-Vis spectrophotometer (200–1000 nm, tungsten and deuterium lamps) for absorbance and transmittance, quantitative analysis, kinetics and DNA\/protein detection in medicine, clinical testing, biochemistry, petrochemical, environmental and food testing, and for teaching.\u003c\/p\u003e\u003ch4\u003eWhat is supplied with the SP-UV1000?\u003c\/h4\u003e\u003cp\u003eMain unit with 4 glass square cuvettes and 2 quartz square cuvettes (as listed in the DLAB price list); other contents to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Labmart provide a GST invoice and bulk or institutional quotation for the DLAB SP-UV1000?\u003c\/h4\u003e\u003cp\u003eYes. GST invoice and bulk or institutional quotations are available; contact us with your quantity.\u003c\/p\u003e\u003ch4\u003eWhat is the HSN code?\u003c\/h4\u003e\u003cp\u003eConfirmed on your quotation and invoice.\u003c\/p\u003e\u003ch4\u003eWhat warranty does it carry?\u003c\/h4\u003e\u003cp\u003eConfirmed in your quotation; please ask before ordering.\u003c\/p\u003e\u003ch4\u003eWhat is the delivery period?\u003c\/h4\u003e\u003cp\u003eDelivery Period – 10 days.\u003c\/p\u003e\u003ch4\u003eCan I order accessories separately?\u003c\/h4\u003e\u003cp\u003eYes, cuvettes, cell holders, lamps, filters and software are supplied separately. Contact Labmart with your requirement.\u003c\/p\u003e\u003ch4\u003eWhich voltage does it work on?\u003c\/h4\u003e\u003cp\u003e110\/220 V AC, 50\/60 Hz.\u003c\/p\u003e\u003ch4\u003eIs installation or training available?\u003c\/h4\u003e\u003cp\u003ePlease contact Labmart; confirmed in your quotation.\u003c\/p\u003e\u003ch4\u003eIs it a genuine DLAB product?\u003c\/h4\u003e\u003cp\u003eYes, supplied under the DLAB brand per the DLAB price list FY26-27.\u003c\/p\u003e","brand":"DLAB","offers":[{"title":"Unit","offer_id":67724422578473,"sku":"4010110101","price":324599.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/DLAB-SP-UV1000.jpg?v=1793597361"},{"product_id":"dlab-sp-uv1100-uv-vis-spectrophotometer","title":"DLAB SP-UV1100 UV-Vis Spectrophotometer, 190–1100 nm, 2 nm","description":"\u003cp\u003eThe DLAB SP-UV1100 is a single-beam UV-Vis spectrophotometer (190–1100 nm, tungsten and deuterium lamps, 2 nm bandwidth) for absorbance and transmittance, quantitative analysis, kinetics and DNA\/protein detection in medicine, clinical testing, biochemistry, petrochemical, environmental and food testing, and for teaching.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProfessional, compact design with an easy-to-operate interface\u003c\/li\u003e\n\u003cli\u003eStores up to 128 sets of standard curves and 4000 test results; data saved in real time to prevent loss on power failure\u003c\/li\u003e\n\u003cli\u003eAutomatic wavelength calibration and dark-current correction\u003c\/li\u003e\n\u003cli\u003eAutomatically switches the light source and turns off the unused lamp to extend lamp life\u003c\/li\u003e\n\u003cli\u003ePhotometry, quantitation, kinetics, multi-wavelength and time scanning, DNA\/protein detection\u003c\/li\u003e\n\u003cli\u003eUSB and print ports; PC software for data handling\u003c\/li\u003e\n\u003cli\u003eOptional accessories: automatic cell holder, film holder, constant-temperature cell holder, reflectivity accessory, variable-path sample holder\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTungsten and deuterium lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.3 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.3–3.0 A, 0–200 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.002 A\/0.5 A, ±0.004 A\/1.0 A, ±0.3 %T\/100 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.001 A\/0.5 A, ≤0.002 A\/1.0 A, ≤0.15 %T\/100 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.002 A\/h at 500 nm (after 2 h preheat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStray light\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.05 %T\/(220–360 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample room\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-connected cell, 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB port, print port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\/220 V AC, 50\/60 Hz, 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L×W×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e490 × 360 × 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelivery period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eSupplied with\u003c\/h3\u003e\u003cp\u003eMain unit with 4 glass square cuvettes and 2 quartz square cuvettes (as listed in the DLAB price list); other contents to confirm.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDelivery Period – 10 days.\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the DLAB SP-UV1100 used for?\u003c\/h4\u003e\u003cp\u003eThe DLAB SP-UV1100 is a single-beam UV-Vis spectrophotometer (190–1100 nm, tungsten and deuterium lamps, 2 nm bandwidth) for absorbance and transmittance, quantitative analysis, kinetics and DNA\/protein detection in medicine, clinical testing, biochemistry, petrochemical, environmental and food testing, and for teaching.\u003c\/p\u003e\u003ch4\u003eWhat is supplied with the SP-UV1100?\u003c\/h4\u003e\u003cp\u003eMain unit with 4 glass square cuvettes and 2 quartz square cuvettes (as listed in the DLAB price list); other contents to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Labmart provide a GST invoice and bulk or institutional quotation for the DLAB SP-UV1100?\u003c\/h4\u003e\u003cp\u003eYes. GST invoice and bulk or institutional quotations are available; contact us with your quantity.\u003c\/p\u003e\u003ch4\u003eWhat is the HSN code?\u003c\/h4\u003e\u003cp\u003eConfirmed on your quotation and invoice.\u003c\/p\u003e\u003ch4\u003eWhat warranty does it carry?\u003c\/h4\u003e\u003cp\u003eConfirmed in your quotation; please ask before ordering.\u003c\/p\u003e\u003ch4\u003eWhat is the delivery period?\u003c\/h4\u003e\u003cp\u003eDelivery Period – 10 days.\u003c\/p\u003e\u003ch4\u003eCan I order accessories separately?\u003c\/h4\u003e\u003cp\u003eYes, cuvettes, cell holders, lamps, filters and software are supplied separately. Contact Labmart with your requirement.\u003c\/p\u003e\u003ch4\u003eWhich voltage does it work on?\u003c\/h4\u003e\u003cp\u003e110\/220 V AC, 50\/60 Hz.\u003c\/p\u003e\u003ch4\u003eIs installation or training available?\u003c\/h4\u003e\u003cp\u003ePlease contact Labmart; confirmed in your quotation.\u003c\/p\u003e\u003ch4\u003eIs it a genuine DLAB product?\u003c\/h4\u003e\u003cp\u003eYes, supplied under the DLAB brand per the DLAB price list FY26-27.\u003c\/p\u003e","brand":"DLAB","offers":[{"title":"Unit","offer_id":67724422611241,"sku":"4010120102","price":425799.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/DLAB-SP-UV1100.png?v=1793597370"},{"product_id":"dlab-sp-uv2101-touch-screen-single-beam-uv-vis-spectrophotometer","title":"DLAB SP-UV2101 Touch Screen Single Beam UV-Vis Spectrophotometer, 190–1100 nm, 1 nm","description":"\u003cp\u003eThe DLAB SP-UV2101 is a touch-screen single-beam UV-Vis spectrophotometer (190–1100 nm, 1 nm bandwidth) with a 10.1-inch colour display, for photometric and quantitative measurement, kinetics, spectrum scan and DNA\/protein tests.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e10.1-inch high-resolution TFT capacitive touch screen (1024×600) with Windows-style graphic interface\u003c\/li\u003e\n\u003cli\u003ePhotometric and quantitative measurement, kinetics, spectrum scan, DNA\/protein test and multi-wavelength test\u003c\/li\u003e\n\u003cli\u003eBuilt-in memory of up to 1024 MB for test data and working curves\u003c\/li\u003e\n\u003cli\u003eUSB storage; data can be exported to Excel for further processing, analysis and storage\u003c\/li\u003e\n\u003cli\u003eSocket-type lamps allow lamp replacement without optical realignment\u003c\/li\u003e\n\u003cli\u003eGLP\/GMP support: user management, logging, data tracking and export\u003c\/li\u003e\n\u003cli\u003eOptional accessories: automatic cell holder, thermostatic automatic sampler, adjustable micro-cell holder, reflection accessory, integrating sphere\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle beam, grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 nm at 656.1 nm, ±0.3 nm overall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 %T (0–100 %T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.15 %T (0–100 %T), 0.001 A (0–0.5 A), 0.002 A (0.5–1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–200 %T, -0.3–3 A, 0–9999 C (0–9999 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStray light\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.03 %T at 220 nm, 360 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.0003 A\/h at 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseline flatness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.001 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0005 A at 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT, A, C, E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScanning speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh, medium, low (max. 3000 nm\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1\" TFT colour capacitive touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeuterium and tungsten lamps (imported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImported silicon photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCuvette holder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mm manual 4-cell holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB drive, USB host, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 220 V\/50 Hz or AC 110 V\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e810 × 660 × 390 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelivery period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eSupplied with\u003c\/h3\u003e\u003cp\u003eMain unit with 4 × 10 mm glass cuvettes, 2 × 10 mm quartz cuvettes, power cord, user's manual and PC software (as listed in the catalogue).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDelivery Period – 10 days.\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the DLAB SP-UV2101 used for?\u003c\/h4\u003e\u003cp\u003eThe DLAB SP-UV2101 is a touch-screen single-beam UV-Vis spectrophotometer (190–1100 nm, 1 nm bandwidth) with a 10.1-inch colour display, for photometric and quantitative measurement, kinetics, spectrum scan and DNA\/protein tests.\u003c\/p\u003e\u003ch4\u003eWhat is supplied with the SP-UV2101?\u003c\/h4\u003e\u003cp\u003eMain unit with 4 × 10 mm glass cuvettes, 2 × 10 mm quartz cuvettes, power cord, user's manual and PC software (as listed in the catalogue).\u003c\/p\u003e\u003ch4\u003eDoes Labmart provide a GST invoice and bulk or institutional quotation for the DLAB SP-UV2101?\u003c\/h4\u003e\u003cp\u003eYes. GST invoice and bulk or institutional quotations are available; contact us with your quantity.\u003c\/p\u003e\u003ch4\u003eWhat is the HSN code?\u003c\/h4\u003e\u003cp\u003eConfirmed on your quotation and invoice.\u003c\/p\u003e\u003ch4\u003eWhat warranty does it carry?\u003c\/h4\u003e\u003cp\u003eConfirmed in your quotation; please ask before ordering.\u003c\/p\u003e\u003ch4\u003eWhat is the delivery period?\u003c\/h4\u003e\u003cp\u003eDelivery Period – 10 days.\u003c\/p\u003e\u003ch4\u003eCan I order accessories separately?\u003c\/h4\u003e\u003cp\u003eYes, cuvettes, cell holders, lamps, filters and software are supplied separately. Contact Labmart with your requirement.\u003c\/p\u003e\u003ch4\u003eWhich voltage does it work on?\u003c\/h4\u003e\u003cp\u003eAC 220 V\/50 Hz or AC 110 V\/60 Hz.\u003c\/p\u003e\u003ch4\u003eIs installation or training available?\u003c\/h4\u003e\u003cp\u003ePlease contact Labmart; confirmed in your quotation.\u003c\/p\u003e\u003ch4\u003eIs it a genuine DLAB product?\u003c\/h4\u003e\u003cp\u003eYes, supplied under the DLAB brand per the DLAB price list FY26-27.\u003c\/p\u003e","brand":"DLAB","offers":[{"title":"Unit","offer_id":67724423430441,"sku":"4010330202","price":489699.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/DLAB-SP-UV2101.jpg?v=1793597375"},{"product_id":"dlab-sp-uv2102-touch-screen-single-beam-uv-vis-spectrophotometer","title":"DLAB SP-UV2102 Touch Screen Single Beam UV-Vis Spectrophotometer, 190–1100 nm, 2 nm","description":"\u003cp\u003eThe DLAB SP-UV2102 is a touch-screen single-beam UV-Vis spectrophotometer (190–1100 nm, 2 nm bandwidth) with a 10.1-inch colour display, for photometric and quantitative measurement, kinetics, spectrum scan and DNA\/protein tests.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e10.1-inch high-resolution TFT capacitive touch screen (1024×600) with Windows-style graphic interface\u003c\/li\u003e\n\u003cli\u003ePhotometric and quantitative measurement, kinetics, spectrum scan, DNA\/protein test and multi-wavelength test\u003c\/li\u003e\n\u003cli\u003eBuilt-in memory of up to 1024 MB for test data and working curves\u003c\/li\u003e\n\u003cli\u003eUSB storage; data can be exported to Excel for further processing, analysis and storage\u003c\/li\u003e\n\u003cli\u003eSocket-type lamps allow lamp replacement without optical realignment\u003c\/li\u003e\n\u003cli\u003eGLP\/GMP support: user management, logging, data tracking and export\u003c\/li\u003e\n\u003cli\u003eOptional accessories: automatic cell holder, thermostatic automatic sampler, adjustable micro-cell holder, reflection accessory, integrating sphere\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle beam, grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 nm at 656.1 nm, ±0.3 nm overall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 %T (0–100 %T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.15 %T (0–100 %T), 0.001 A (0–0.5 A), 0.002 A (0.5–1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhotometric range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–200 %T, -0.3–3 A, 0–9999 C (0–9999 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStray light\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.03 %T at 220 nm, 360 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.0003 A\/h at 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseline flatness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.001 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0005 A at 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT, A, C, E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScanning speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh, medium, low (max. 3000 nm\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1\" TFT colour capacitive touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeuterium and tungsten lamps (imported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImported silicon photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCuvette holder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mm manual 4-cell holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB drive, USB host, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 220 V\/50 Hz or AC 110 V\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e810 × 660 × 390 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelivery period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eSupplied with\u003c\/h3\u003e\u003cp\u003eMain unit with 4 × 10 mm glass cuvettes, 2 × 10 mm quartz cuvettes, power cord, user's manual and PC software (as listed in the catalogue).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDelivery Period – 10 days.\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is the DLAB SP-UV2102 used for?\u003c\/h4\u003e\u003cp\u003eThe DLAB SP-UV2102 is a touch-screen single-beam UV-Vis spectrophotometer (190–1100 nm, 2 nm bandwidth) with a 10.1-inch colour display, for photometric and quantitative measurement, kinetics, spectrum scan and DNA\/protein tests.\u003c\/p\u003e\u003ch4\u003eWhat is supplied with the SP-UV2102?\u003c\/h4\u003e\u003cp\u003eMain unit with 4 × 10 mm glass cuvettes, 2 × 10 mm quartz cuvettes, power cord, user's manual and PC software (as listed in the catalogue).\u003c\/p\u003e\u003ch4\u003eDoes Labmart provide a GST invoice and bulk or institutional quotation for the DLAB SP-UV2102?\u003c\/h4\u003e\u003cp\u003eYes. GST invoice and bulk or institutional quotations are available; contact us with your quantity.\u003c\/p\u003e\u003ch4\u003eWhat is the HSN code?\u003c\/h4\u003e\u003cp\u003eConfirmed on your quotation and invoice.\u003c\/p\u003e\u003ch4\u003eWhat warranty does it carry?\u003c\/h4\u003e\u003cp\u003eConfirmed in your quotation; please ask before ordering.\u003c\/p\u003e\u003ch4\u003eWhat is the delivery period?\u003c\/h4\u003e\u003cp\u003eDelivery Period – 10 days.\u003c\/p\u003e\u003ch4\u003eCan I order accessories separately?\u003c\/h4\u003e\u003cp\u003eYes, cuvettes, cell holders, lamps, filters and software are supplied separately. Contact Labmart with your requirement.\u003c\/p\u003e\u003ch4\u003eWhich voltage does it work on?\u003c\/h4\u003e\u003cp\u003eAC 220 V\/50 Hz or AC 110 V\/60 Hz.\u003c\/p\u003e\u003ch4\u003eIs installation or training available?\u003c\/h4\u003e\u003cp\u003ePlease contact Labmart; confirmed in your quotation.\u003c\/p\u003e\u003ch4\u003eIs it a genuine DLAB product?\u003c\/h4\u003e\u003cp\u003eYes, supplied under the DLAB brand per the DLAB price list FY26-27.\u003c\/p\u003e","brand":"DLAB","offers":[{"title":"Unit","offer_id":67724423463209,"sku":"4010320202","price":454799.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/DLAB-SP-UV2102.jpg?v=1793597380"},{"product_id":"uv-vis-spectrophotometer-single-beam-190-1000nm-2nm","title":"UV-Vis Spectrophotometer, Single Beam, 190–1000nm, 2nm Bandwidth, USB I Automatic Scanning","description":"\u003cp\u003e\u003cstrong\u003eModel UV-205\u003c\/strong\u003e – This single beam UV-Vis spectrophotometer covers 190 to 1000 nm with 2 nm bandwidth, using deuterium and tungsten halogen lamps and a silicon photodiode detector. Automatic wavelength setting and a 4-cell holder suit routine absorbance, transmittance and concentration work in teaching, QC and research labs.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWavelength range 190–1000 nm, 2 nm bandwidth\u003c\/li\u003e\n\u003cli\u003eDeuterium and tungsten halogen lamps with silicon photodiode detector\u003c\/li\u003e\n\u003cli\u003eLow stray-light design on a die-cast aluminium base with injection-moulded inner compartments\u003c\/li\u003e\n\u003cli\u003eDisplays wavelength, absorbance, transmittance and energy (T, A, C, E modes)\u003c\/li\u003e\n\u003cli\u003eAutomatic wavelength setting using arrow keys\u003c\/li\u003e\n\u003cli\u003e10 mm manual 4-cell holder\u003c\/li\u003e\n\u003cli\u003eUSB port for PC connection; wavelength scanning to find lambda max with the PC software\u003c\/li\u003e\n\u003cli\u003ePC software supports photometric and quantitative analysis, spectral scanning, kinetics, DNA\/protein analysis and multi-wavelength tests\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUV-205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical system\u003c\/td\u003e\n\u003ctd\u003eSingle beam, 1200 lines\/mm grating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength range\u003c\/td\u003e\n\u003ctd\u003e190 to 1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength repeatability\u003c\/td\u003e\n\u003ctd\u003e± 0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength setting\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric range\u003c\/td\u003e\n\u003ctd\u003e-0.3 to 3 A, 0 to 200 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.5 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric repeatability\u003c\/td\u003e\n\u003ctd\u003e± 0.3 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e± 0.002 A\/h at 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline flatness\u003c\/td\u003e\n\u003ctd\u003e± 0.002 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement modes\u003c\/td\u003e\n\u003ctd\u003eT, A, C, E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eSilicon photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eDeuterium (D2) and tungsten halogen lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell holder\u003c\/td\u003e\n\u003ctd\u003e10 mm manual 4-cell holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eUSB and parallel port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eAC 220 V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \u0026amp; weight\u003c\/td\u003e\n\u003ctd\u003e650 x 520 x 340 mm, 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eSupplied With\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain instrument\u003c\/li\u003e\n\u003cli\u003e10 mm glass cuvette\u003c\/li\u003e\n\u003cli\u003e10 mm quartz cuvette\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003ePC software\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDelivery Period – 10 days\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch4\u003eDo you provide a GST invoice and bulk or institutional quotation?\u003c\/h4\u003e\u003cp\u003eYes. A GST invoice is provided with every order, and quotations for colleges, hospitals, pharma companies and government labs, including bulk orders, are available on request.\u003c\/p\u003e\u003ch4\u003eWhat is the HSN code?\u003c\/h4\u003e\u003cp\u003eTo confirm. Please contact us and we will share the applicable HSN code on your quotation.\u003c\/p\u003e\u003ch4\u003eWhat is the wavelength range?\u003c\/h4\u003e\u003cp\u003e190 to 1000 nm, covering both UV and visible regions.\u003c\/p\u003e\u003ch4\u003eIs PC software included?\u003c\/h4\u003e\u003cp\u003eYes. PC software is supplied with the instrument.\u003c\/p\u003e\u003ch4\u003eWhat warranty is provided?\u003c\/h4\u003e\u003cp\u003e12 months from the date of dispatch against manufacturing defects. Fragile parts and third-party parts are excluded.\u003c\/p\u003e\u003ch4\u003eWhat is the delivery time?\u003c\/h4\u003e\u003cp\u003eDelivery period is 10 days. Freight is charged extra.\u003c\/p\u003e\u003ch4\u003eWhat is supplied with the product?\u003c\/h4\u003e\u003cp\u003eSee the Supplied With list above.\u003c\/p\u003e\u003ch4\u003eWhat are the power requirements?\u003c\/h4\u003e\u003cp\u003eAC 220 V, 50 Hz.\u003c\/p\u003e\u003ch4\u003eIs installation support available?\u003c\/h4\u003e\u003cp\u003eYes. Online installation and operating guidance is provided.\u003c\/p\u003e\u003ch4\u003eCan your team help me choose the right model?\u003c\/h4\u003e\u003cp\u003eYes. Our technical team can help you compare models and choose the right capacity or class for your application.\u003c\/p\u003e","brand":"Spectrix","offers":[{"title":"Default Title","offer_id":67747040919849,"sku":"UV-205","price":87999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/UV-205.jpg?v=1793779237"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/collections\/Single_Beam_LMSPV325_Spectrophotometer-3986380.jpg?v=1775814771","url":"https:\/\/www.labmart.in\/collections\/single-beam-spectrophotometer.oembed?page=3","provider":"Labmart.in","version":"1.0","type":"link"}