{"title":"Gas Chromatography","description":"\u003cp data-end=\"91\" data-start=\"0\"\u003e\u003cstrong data-end=\"91\" data-start=\"0\"\u003eGas Chromatography (GC) – High-Precision Analytical Instruments for Modern Laboratories\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"455\" data-start=\"93\"\u003eGas Chromatography (GC) is an essential analytical technique used for the separation, identification, and quantification of volatile compounds in a sample. Widely used across industries such as pharmaceuticals, environmental testing, food safety, petrochemicals, and research laboratories, GC systems deliver unmatched accuracy, sensitivity, and reproducibility.\u003c\/p\u003e\n\u003cp data-end=\"685\" data-start=\"457\"\u003eAt\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e, we offer a comprehensive range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"597\" data-start=\"533\"\u003eGas Chromatography instruments, accessories, and consumables\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to meet the needs of both routine analysis and advanced research applications.\u003c\/p\u003e\n\u003chr data-end=\"690\" data-start=\"687\"\u003e\n\u003ch2 data-end=\"725\" data-start=\"692\" data-section-id=\"mb2a2i\"\u003e🔬 What is Gas Chromatography?\u003c\/h2\u003e\n\u003cp data-end=\"1089\" data-start=\"727\"\u003eGas Chromatography works by vaporizing a sample and passing it through a column with an inert carrier gas. Different compounds in the sample travel at different speeds, allowing precise separation and analysis. GC systems are often paired with detectors such as Flame Ionization Detectors (FID) or Mass Spectrometers (GC-MS) for enhanced analytical capabilities.\u003c\/p\u003e\n\u003chr data-end=\"1094\" data-start=\"1091\"\u003e\n\u003ch2 data-end=\"1125\" data-start=\"1096\" data-section-id=\"1nk59ey\"\u003e🚀 Key Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-end=\"1497\" data-start=\"1127\"\u003e\n\u003cli data-end=\"1198\" data-start=\"1127\" data-section-id=\"itq13o\"\u003e\n\u003cp data-end=\"1198\" data-start=\"1129\"\u003e\u003cstrong data-end=\"1160\" data-start=\"1129\"\u003eHigh Sensitivity \u0026amp; Accuracy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Detect even trace-level compounds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1258\" data-start=\"1199\" data-section-id=\"rqctyv\"\u003e\n\u003cp data-end=\"1258\" data-start=\"1201\"\u003e\u003cstrong data-end=\"1223\" data-start=\"1201\"\u003eFast Analysis Time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Ideal for high-throughput labs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1344\" data-start=\"1259\" data-section-id=\"16itbi0\"\u003e\n\u003cp data-end=\"1344\" data-start=\"1261\"\u003e\u003cstrong data-end=\"1287\" data-start=\"1261\"\u003eWide Application Range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Suitable for gases, solvents, hydrocarbons, and more\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1418\" data-start=\"1345\" data-section-id=\"1y1x4ft\"\u003e\n\u003cp data-end=\"1418\" data-start=\"1347\"\u003e\u003cstrong data-end=\"1370\" data-start=\"1347\"\u003eAutomated Operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Improves efficiency and reduces human error\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1497\" data-start=\"1419\" data-section-id=\"orv8a2\"\u003e\n\u003cp data-end=\"1497\" data-start=\"1421\"\u003e\u003cstrong data-end=\"1456\" data-start=\"1421\"\u003eReliable \u0026amp; Reproducible Results\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Critical for compliance and research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1502\" data-start=\"1499\"\u003e\n\u003ch2 data-end=\"1551\" data-start=\"1504\" data-section-id=\"1wpnz25\"\u003e🧪 Common Applications of Gas Chromatography\u003c\/h2\u003e\n\u003cul data-end=\"1917\" data-start=\"1553\"\u003e\n\u003cli data-end=\"1627\" data-start=\"1553\" data-section-id=\"am7rqk\"\u003e\n\u003cp data-end=\"1627\" data-start=\"1555\"\u003e\u003cstrong data-end=\"1582\" data-start=\"1555\"\u003ePharmaceutical Analysis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Drug purity and residual solvent testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1703\" data-start=\"1628\" data-section-id=\"1qeh8hm\"\u003e\n\u003cp data-end=\"1703\" data-start=\"1630\"\u003e\u003cstrong data-end=\"1655\" data-start=\"1630\"\u003eEnvironmental Testing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Air, water, and soil contamination analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1784\" data-start=\"1704\" data-section-id=\"1v4n3z8\"\u003e\n\u003cp data-end=\"1784\" data-start=\"1706\"\u003e\u003cstrong data-end=\"1734\" data-start=\"1706\"\u003eFood \u0026amp; Beverage Industry\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Flavor profiling, pesticide residue detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1850\" data-start=\"1785\" data-section-id=\"1tsj6zs\"\u003e\n\u003cp data-end=\"1850\" data-start=\"1787\"\u003e\u003cstrong data-end=\"1813\" data-start=\"1787\"\u003ePetrochemical Industry\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Hydrocarbon composition analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1917\" data-start=\"1851\" data-section-id=\"1j9iv92\"\u003e\n\u003cp data-end=\"1917\" data-start=\"1853\"\u003e\u003cstrong data-end=\"1873\" data-start=\"1853\"\u003eForensic Science\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Toxicology and substance identification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1922\" data-start=\"1919\"\u003e\n\u003ch2 data-section-id=\"1etv3qy\" data-start=\"119\" data-end=\"188\"\u003e🧪 Gas Chromatography Systems – Buy GC Instruments Online in India\u003c\/h2\u003e\n\u003cp data-start=\"190\" data-end=\"731\"\u003eExplore a premium range of \u003cstrong data-start=\"217\" data-end=\"256\"\u003egas chromatography systems in India\u003c\/strong\u003e at \u003cstrong data-start=\"260\" data-end=\"271\"\u003eLabmart\u003c\/strong\u003e, designed for \u003cstrong data-start=\"286\" data-end=\"379\"\u003eaccurate separation, identification, and analysis of volatile and semi-volatile compounds\u003c\/strong\u003e. Our collection includes \u003cstrong data-start=\"405\" data-end=\"559\"\u003egas chromatography (GC) instruments, GC analyzers, capillary gas chromatographs, GC detectors (FID, TCD), autosamplers, and chromatography accessories\u003c\/strong\u003e, ideal for \u003cstrong data-start=\"571\" data-end=\"730\"\u003epharmaceutical industries, chemical laboratories, environmental testing labs, food \u0026amp; beverage industries, petrochemical industries, and research institutes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"733\" data-end=\"1077\"\u003eLabmart offers \u003cstrong data-start=\"748\" data-end=\"800\"\u003ehigh-quality gas chromatography equipment online\u003c\/strong\u003e that ensures \u003cstrong data-start=\"814\" data-end=\"891\"\u003ehigh sensitivity, precise separation, and reliable analytical performance\u003c\/strong\u003e. These systems are essential for \u003cstrong data-start=\"925\" data-end=\"1015\"\u003etrace analysis, impurity detection, quality control, and chemical composition analysis\u003c\/strong\u003e, making them indispensable in modern analytical laboratories.\u003c\/p\u003e\n\u003cp data-start=\"1079\" data-end=\"1287\"\u003eWhether you need a \u003cstrong data-start=\"1098\" data-end=\"1213\"\u003ecompact GC system for routine testing or an advanced gas chromatograph for research and industrial applications\u003c\/strong\u003e, Labmart provides \u003cstrong data-start=\"1232\" data-end=\"1286\"\u003edurable, efficient, and high-performance solutions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1289\" data-end=\"1292\"\u003e\n\u003ch2 data-section-id=\"sxzlft\" data-start=\"1294\" data-end=\"1364\"\u003e🔑 Why Labmart.in is the Go-To Place for Gas Chromatography Systems\u003c\/h2\u003e\n\u003cul data-start=\"1366\" data-end=\"1888\"\u003e\n\u003cli data-section-id=\"1y57zwv\" data-start=\"1366\" data-end=\"1432\"\u003e✔ Wide range of \u003cstrong data-start=\"1384\" data-end=\"1430\"\u003egas chromatography systems and accessories\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fvn3po\" data-start=\"1433\" data-end=\"1488\"\u003e✔ High precision for \u003cstrong data-start=\"1456\" data-end=\"1486\"\u003evolatile compound analysis\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ejdvm\" data-start=\"1489\" data-end=\"1594\"\u003e✔ Advanced detectors like \u003cstrong data-start=\"1517\" data-end=\"1592\"\u003eFID (Flame Ionization Detector) and TCD (Thermal Conductivity Detector)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ipwgnn\" data-start=\"1595\" data-end=\"1679\"\u003e✔ Suitable for \u003cstrong data-start=\"1612\" data-end=\"1677\"\u003epharmaceutical, petrochemical, and environmental applications\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4q565k\" data-start=\"1680\" data-end=\"1757\"\u003e✔ Competitive pricing for \u003cstrong data-start=\"1708\" data-end=\"1755\"\u003elabs, industries, and institutions in India\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dv9f4l\" data-start=\"1758\" data-end=\"1823\"\u003e✔ Trusted supplier of \u003cstrong data-start=\"1782\" data-end=\"1821\"\u003escientific and laboratory equipment\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uu543w\" data-start=\"1824\" data-end=\"1888\"\u003e✔ Reliable support and seamless online purchasing experience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1890\" data-end=\"2052\"\u003eLabmart.in is a \u003cstrong data-start=\"1906\" data-end=\"1979\"\u003etrusted destination to buy gas chromatography systems online in India\u003c\/strong\u003e, offering dependable solutions for analytical and research laboratories.\u003c\/p\u003e\n\u003chr data-start=\"2054\" data-end=\"2057\"\u003e\n\u003ch2 data-section-id=\"r4kvty\" data-start=\"2059\" data-end=\"2107\"\u003e🧪 Applications of Gas Chromatography Systems\u003c\/h2\u003e\n\u003cp data-start=\"2109\" data-end=\"2155\"\u003eGas chromatography systems are widely used in:\u003c\/p\u003e\n\u003cul data-start=\"2157\" data-end=\"2696\"\u003e\n\u003cli data-section-id=\"u58t5g\" data-start=\"2157\" data-end=\"2230\"\u003e💊 \u003cstrong data-start=\"2162\" data-end=\"2189\"\u003ePharmaceutical Industry\u003c\/strong\u003e – Drug analysis and impurity detection\u003c\/li\u003e\n\u003cli data-section-id=\"1xoxfss\" data-start=\"2231\" data-end=\"2317\"\u003e🧪 \u003cstrong data-start=\"2236\" data-end=\"2261\"\u003eChemical Laboratories\u003c\/strong\u003e – Separation and identification of volatile compounds\u003c\/li\u003e\n\u003cli data-section-id=\"2cdghi\" data-start=\"2318\" data-end=\"2403\"\u003e🌱 \u003cstrong data-start=\"2323\" data-end=\"2348\"\u003eEnvironmental Testing\u003c\/strong\u003e – Detection of pollutants and air\/water contaminants\u003c\/li\u003e\n\u003cli data-section-id=\"6nimg7\" data-start=\"2404\" data-end=\"2478\"\u003e🛢️ \u003cstrong data-start=\"2410\" data-end=\"2436\"\u003ePetrochemical Industry\u003c\/strong\u003e – Hydrocarbon analysis and fuel testing\u003c\/li\u003e\n\u003cli data-section-id=\"1te8m8a\" data-start=\"2479\" data-end=\"2548\"\u003e🧫 \u003cstrong data-start=\"2484\" data-end=\"2512\"\u003eFood \u0026amp; Beverage Industry\u003c\/strong\u003e – Flavor and contaminant analysis\u003c\/li\u003e\n\u003cli data-section-id=\"18xznss\" data-start=\"2549\" data-end=\"2618\"\u003e🔬 \u003cstrong data-start=\"2554\" data-end=\"2579\"\u003eResearch Laboratories\u003c\/strong\u003e – Analytical and biochemical studies\u003c\/li\u003e\n\u003cli data-section-id=\"96kgq2\" data-start=\"2619\" data-end=\"2696\"\u003e🏭 \u003cstrong data-start=\"2624\" data-end=\"2651\"\u003eIndustrial Applications\u003c\/strong\u003e – Process monitoring and quality assurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2698\" data-end=\"2701\"\u003e\n\u003ch2 data-section-id=\"ietzmw\" data-start=\"2703\" data-end=\"2741\"\u003e❓ Frequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1wvb5f6\" data-start=\"2743\" data-end=\"2782\"\u003e1. What is gas chromatography (GC)?\u003c\/h3\u003e\n\u003cp data-start=\"2783\" data-end=\"2893\"\u003eGas chromatography is an \u003cstrong data-start=\"2808\" data-end=\"2892\"\u003eanalytical technique used to separate and analyze volatile compounds in a sample\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1uo935q\" data-start=\"2895\" data-end=\"2946\"\u003e2. What are the main components of a GC system?\u003c\/h3\u003e\n\u003cp data-start=\"2947\" data-end=\"3034\"\u003eKey components include \u003cstrong data-start=\"2970\" data-end=\"3033\"\u003einjector, column, detector (FID\/TCD), oven, and data system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"4so5rr\" data-start=\"3036\" data-end=\"3082\"\u003e3. What types of detectors are used in GC?\u003c\/h3\u003e\n\u003cp data-start=\"3083\" data-end=\"3184\"\u003eCommon detectors include \u003cstrong data-start=\"3108\" data-end=\"3183\"\u003eFlame Ionization Detector (FID) and Thermal Conductivity Detector (TCD)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1e2sevi\" data-start=\"3186\" data-end=\"3229\"\u003e4. What is gas chromatography used for?\u003c\/h3\u003e\n\u003cp data-start=\"3230\" data-end=\"3313\"\u003eIt is used for \u003cstrong data-start=\"3245\" data-end=\"3312\"\u003echemical analysis, impurity detection, and composition analysis\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1y1cds2\" data-start=\"3315\" data-end=\"3372\"\u003e5. Are GC systems suitable for environmental testing?\u003c\/h3\u003e\n\u003cp data-start=\"3373\" data-end=\"3445\"\u003eYes, they are widely used for \u003cstrong data-start=\"3403\" data-end=\"3444\"\u003edetecting pollutants and contaminants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xzu2uc\" data-start=\"3447\" data-end=\"3514\"\u003e6. Why should I buy gas chromatography systems from Labmart.in?\u003c\/h3\u003e\n\u003cp data-start=\"3515\" data-end=\"3646\"\u003eLabmart offers \u003cstrong data-start=\"3530\" data-end=\"3617\"\u003ehigh-quality equipment, competitive pricing, reliable support, and a wide selection\u003c\/strong\u003e, making it a trusted choice.\u003c\/p\u003e\n\u003ch3 data-section-id=\"qzl2ll\" data-start=\"3648\" data-end=\"3689\"\u003e7. Do GC systems require maintenance?\u003c\/h3\u003e\n\u003cp data-start=\"3690\" data-end=\"3763\"\u003eYes, regular maintenance ensures \u003cstrong data-start=\"3723\" data-end=\"3762\"\u003eaccurate and consistent performance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-end=\"3639\" data-start=\"3636\"\u003e","products":[{"product_id":"gas-chromatography","title":"Gas chromatography","description":"\u003cp data-section-id=\"1wdow7c\" data-start=\"239\" data-end=\"266\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eThe GC10CI Gas Chromatography system is engineered for high-resolution compound separation and trace-level detection, making it a preferred choice for pharmaceutical labs, environmental testing facilities, and chemical industries. With GLP\/FDA 21 CFR Part 11 compliant software, it ensures data integrity, regulatory compliance, and reliable reporting.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1vgskwa\" data-start=\"268\" data-end=\"287\"\u003eSalient Features\u003c\/h2\u003e\n\u003cul data-start=\"288\" data-end=\"1207\"\u003e\n\u003cli data-section-id=\"1g71si7\" data-start=\"288\" data-end=\"380\"\u003e\n\u003cp data-start=\"290\" data-end=\"380\"\u003e\u003cstrong data-start=\"290\" data-end=\"309\"\u003eControl system:\u003c\/strong\u003e Designed for monitoring and controlling the instrument via computer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xnl3cw\" data-start=\"381\" data-end=\"540\"\u003e\n\u003cp data-start=\"383\" data-end=\"540\"\u003e\u003cstrong data-start=\"383\" data-end=\"411\"\u003eColumn compartment\/oven:\u003c\/strong\u003e Superior thermal performance with multistage (10 ramps) programmed temperature control function (supported by control system).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qhp5re\" data-start=\"541\" data-end=\"685\"\u003e\n\u003cp data-start=\"543\" data-end=\"685\"\u003e\u003cstrong data-start=\"543\" data-end=\"589\"\u003eAdvanced built-in data acquisition system:\u003c\/strong\u003e Supports real-time instrument status monitoring, detection signal acquisition and PC control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18q16un\" data-start=\"686\" data-end=\"819\"\u003e\n\u003cp data-start=\"688\" data-end=\"819\"\u003e\u003cstrong data-start=\"688\" data-end=\"704\"\u003eColumn oven:\u003c\/strong\u003e Accommodates 1 capillary column and supports quick heat-up and rapid cool-down with automated back-door opening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nnuggv\" data-start=\"820\" data-end=\"886\"\u003e\n\u003cp data-start=\"822\" data-end=\"886\"\u003e\u003cstrong data-start=\"822\" data-end=\"853\"\u003eSample introduction system:\u003c\/strong\u003e One sample injector installed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rspe5v\" data-start=\"887\" data-end=\"1018\"\u003e\n\u003cp data-start=\"889\" data-end=\"919\"\u003e\u003cstrong data-start=\"889\" data-end=\"917\"\u003eSample detection system:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"922\" data-end=\"1018\"\u003e\n\u003cli data-section-id=\"ji096q\" data-start=\"922\" data-end=\"1018\"\u003e\n\u003cp data-start=\"924\" data-end=\"1018\"\u003e1 high sensitivity and stability \u003cstrong data-start=\"957\" data-end=\"973\"\u003eFID detector\u003c\/strong\u003e for various organic compound applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16ic2ii\" data-start=\"1019\" data-end=\"1066\"\u003e\n\u003cp data-start=\"1021\" data-end=\"1066\"\u003e\u003cstrong data-start=\"1021\" data-end=\"1046\"\u003eAnalog signal output:\u003c\/strong\u003e 1 output channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rerrvl\" data-start=\"1067\" data-end=\"1207\"\u003e\n\u003cp data-start=\"1069\" data-end=\"1207\"\u003e\u003cstrong data-start=\"1069\" data-end=\"1096\"\u003eSoftware compatibility:\u003c\/strong\u003e Compatible with \u003cstrong data-start=\"1113\" data-end=\"1141\"\u003eGLP \/ FDA-21 CFR Part 11\u003c\/strong\u003e requirements and regulations (electronic records and signatures).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1209\" data-end=\"1212\"\u003e\n\u003ch3 data-section-id=\"1lrs84y\" data-start=\"1214\" data-end=\"1240\"\u003eFID General Applications\u003c\/h3\u003e\n\u003cul data-start=\"1241\" data-end=\"1626\"\u003e\n\u003cli data-section-id=\"1n4wzqt\" data-start=\"1241\" data-end=\"1307\"\u003e\n\u003cp data-start=\"1243\" data-end=\"1267\"\u003eNitrobenzene compounds\u003c\/p\u003e\n\u003cul data-start=\"1270\" data-end=\"1307\"\u003e\n\u003cli data-section-id=\"1kllvkr\" data-start=\"1270\" data-end=\"1286\"\u003e\n\u003cp data-start=\"1272\" data-end=\"1286\"\u003eNitrobenzene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xpkllz\" data-start=\"1289\" data-end=\"1307\"\u003e\n\u003cp data-start=\"1291\" data-end=\"1307\"\u003eDinitrotoluene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13omysf\" data-start=\"1309\" data-end=\"1401\"\u003e\n\u003cp data-start=\"1311\" data-end=\"1336\"\u003eChlorobenzene compounds\u003c\/p\u003e\n\u003cul data-start=\"1339\" data-end=\"1401\"\u003e\n\u003cli data-section-id=\"1bij6v4\" data-start=\"1339\" data-end=\"1356\"\u003e\n\u003cp data-start=\"1341\" data-end=\"1356\"\u003eChlorobenzene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19totd9\" data-start=\"1359\" data-end=\"1378\"\u003e\n\u003cp data-start=\"1361\" data-end=\"1378\"\u003eDichlorobenzene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ayohjj\" data-start=\"1381\" data-end=\"1401\"\u003e\n\u003cp data-start=\"1383\" data-end=\"1401\"\u003eTrichlorobenzene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tlw3z3\" data-start=\"1403\" data-end=\"1526\"\u003e\n\u003cp data-start=\"1405\" data-end=\"1421\"\u003eBenzene series\u003c\/p\u003e\n\u003cul data-start=\"1424\" data-end=\"1526\"\u003e\n\u003cli data-section-id=\"lq6tlw\" data-start=\"1424\" data-end=\"1435\"\u003e\n\u003cp data-start=\"1426\" data-end=\"1435\"\u003eToluene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wo7d5l\" data-start=\"1438\" data-end=\"1454\"\u003e\n\u003cp data-start=\"1440\" data-end=\"1454\"\u003eEthylbenzene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"180v2mh\" data-start=\"1457\" data-end=\"1469\"\u003e\n\u003cp data-start=\"1459\" data-end=\"1469\"\u003eO-Xylene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4k58ej\" data-start=\"1472\" data-end=\"1484\"\u003e\n\u003cp data-start=\"1474\" data-end=\"1484\"\u003eM-Xylene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"bna22e\" data-start=\"1487\" data-end=\"1499\"\u003e\n\u003cp data-start=\"1489\" data-end=\"1499\"\u003eP-Xylene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"149bdd6\" data-start=\"1502\" data-end=\"1513\"\u003e\n\u003cp data-start=\"1504\" data-end=\"1513\"\u003eStyrene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gqm9gd\" data-start=\"1516\" data-end=\"1526\"\u003e\n\u003cp data-start=\"1518\" data-end=\"1526\"\u003eCumene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"glpmdk\" data-start=\"1528\" data-end=\"1575\"\u003e\n\u003cp data-start=\"1530\" data-end=\"1575\"\u003e\u003cstrong data-start=\"1530\" data-end=\"1573\"\u003eTVOC (Total Volatile Organic Compounds)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hjqkok\" data-start=\"1576\" data-end=\"1626\"\u003e\n\u003cp data-start=\"1578\" data-end=\"1600\"\u003e\u003cstrong data-start=\"1578\" data-end=\"1600\"\u003ePhenolic compounds\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1603\" data-end=\"1626\"\u003e\n\u003cli data-section-id=\"1m6eqjc\" data-start=\"1603\" data-end=\"1613\"\u003e\n\u003cp data-start=\"1605\" data-end=\"1613\"\u003ePhenol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xontf0\" data-start=\"1616\" data-end=\"1626\"\u003e\n\u003cp data-start=\"1618\" data-end=\"1626\"\u003eCresol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1628\" data-end=\"1736\"\u003eNote: Depending on test circumstances, \u003cstrong data-start=\"1667\" data-end=\"1719\"\u003eheadspace sampler or thermal analysis instrument\u003c\/strong\u003e may be required.\u003c\/p\u003e\n\u003chr data-start=\"1738\" data-end=\"1741\"\u003e\n\u003ch3 data-section-id=\"8hqlwo\" data-start=\"1743\" data-end=\"1787\"\u003eSoftware: Advanced Computer Control System\u003c\/h3\u003e\n\u003cul data-start=\"1788\" data-end=\"2213\"\u003e\n\u003cli data-section-id=\"sjs0ci\" data-start=\"1788\" data-end=\"1869\"\u003e\n\u003cp data-start=\"1790\" data-end=\"1869\"\u003eSuperior performance with advanced computer-based temperature control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1uiny8h\" data-start=\"1870\" data-end=\"1922\"\u003e\n\u003cp data-start=\"1872\" data-end=\"1922\"\u003eHigh temperature accuracy \u003cstrong data-start=\"1898\" data-end=\"1919\"\u003e(±0.02°C optimum)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ctvhum\" data-start=\"1923\" data-end=\"1978\"\u003e\n\u003cp data-start=\"1925\" data-end=\"1978\"\u003eHigh reliability with anti-interference protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zo1oie\" data-start=\"1979\" data-end=\"2094\"\u003e\n\u003cp data-start=\"1981\" data-end=\"2041\"\u003e\u003cstrong data-start=\"1981\" data-end=\"2029\"\u003eSelf-diagnosis and self-protection functions\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"2044\" data-end=\"2094\"\u003e\n\u003cli data-section-id=\"1ivqwvx\" data-start=\"2044\" data-end=\"2067\"\u003e\n\u003cp data-start=\"2046\" data-end=\"2067\"\u003eOverheat protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t6wn92\" data-start=\"2070\" data-end=\"2094\"\u003e\n\u003cp data-start=\"2072\" data-end=\"2094\"\u003ePower-off protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gtjmjd\" data-start=\"2095\" data-end=\"2213\"\u003e\n\u003cp data-start=\"2097\" data-end=\"2123\"\u003eIntuitive display showing:\u003c\/p\u003e\n\u003cul data-start=\"2126\" data-end=\"2213\"\u003e\n\u003cli data-section-id=\"p586k\" data-start=\"2126\" data-end=\"2144\"\u003e\n\u003cp data-start=\"2128\" data-end=\"2144\"\u003eTiming program\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4zpuva\" data-start=\"2147\" data-end=\"2166\"\u003e\n\u003cp data-start=\"2149\" data-end=\"2166\"\u003eDetector status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"189ryot\" data-start=\"2169\" data-end=\"2190\"\u003e\n\u003cp data-start=\"2171\" data-end=\"2190\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"30gmn8\" data-start=\"2193\" data-end=\"2213\"\u003e\n\u003cp data-start=\"2195\" data-end=\"2213\"\u003eCurrent settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2215\" data-end=\"2320\"\u003e\u003cstrong data-start=\"2215\" data-end=\"2224\"\u003eNote:\u003c\/strong\u003e Computer is not included with the instrument. User must provide a computer to run the software.\u003c\/p\u003e\n\u003chr data-start=\"2322\" data-end=\"2325\"\u003e\n\u003ch3 data-section-id=\"1spgaq0\" data-start=\"2327\" data-end=\"2343\"\u003eSpecifications\u003c\/h3\u003e\n\u003cp data-start=\"2345\" data-end=\"2389\"\u003e\u003cstrong data-start=\"2345\" data-end=\"2355\"\u003eModel:\u003c\/strong\u003e GC10CI\u003cbr data-start=\"2362\" data-end=\"2365\"\u003e\u003cstrong data-start=\"2365\" data-end=\"2378\"\u003eHSN Code:\u003c\/strong\u003e 90272000\u003c\/p\u003e\n\u003ch3 data-section-id=\"16umh3v\" data-start=\"2391\" data-end=\"2415\"\u003eStandard Accessories\u003c\/h3\u003e\n\u003cul data-start=\"2416\" data-end=\"2498\"\u003e\n\u003cli data-section-id=\"1t4gtg4\" data-start=\"2416\" data-end=\"2439\"\u003e\n\u003cp data-start=\"2418\" data-end=\"2439\"\u003eMain instrument set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18cmsjx\" data-start=\"2440\" data-end=\"2454\"\u003e\n\u003cp data-start=\"2442\" data-end=\"2454\"\u003ePower cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1578cq\" data-start=\"2455\" data-end=\"2477\"\u003e\n\u003cp data-start=\"2457\" data-end=\"2477\"\u003eInstruction manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hg2otn\" data-start=\"2478\" data-end=\"2498\"\u003e\n\u003cp data-start=\"2480\" data-end=\"2498\"\u003eTest certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2500\" data-end=\"2503\"\u003e\n\u003ch3 data-section-id=\"8o5s9t\" data-start=\"2505\" data-end=\"2519\"\u003eColumn Oven\u003c\/h3\u003e\n\u003cul data-start=\"2520\" data-end=\"2829\"\u003e\n\u003cli data-section-id=\"cna36t\" data-start=\"2520\" data-end=\"2580\"\u003e\n\u003cp data-start=\"2522\" data-end=\"2580\"\u003e\u003cstrong data-start=\"2522\" data-end=\"2544\"\u003eTemperature Range:\u003c\/strong\u003e RT +7°C to 400°C (1°C increments)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6u3k9p\" data-start=\"2581\" data-end=\"2618\"\u003e\n\u003cp data-start=\"2583\" data-end=\"2618\"\u003e\u003cstrong data-start=\"2583\" data-end=\"2608\"\u003eTemperature Accuracy:\u003c\/strong\u003e ±0.02°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1px1oay\" data-start=\"2619\" data-end=\"2688\"\u003e\n\u003cp data-start=\"2621\" data-end=\"2688\"\u003e\u003cstrong data-start=\"2621\" data-end=\"2638\"\u003eCooling Time:\u003c\/strong\u003e 400°C to 50°C in 8–10 minutes (at 25°C ambient)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"b7305c\" data-start=\"2689\" data-end=\"2760\"\u003e\n\u003cp data-start=\"2691\" data-end=\"2760\"\u003e\u003cstrong data-start=\"2691\" data-end=\"2723\"\u003eProgrammed Temperature Rate:\u003c\/strong\u003e 0.1°C to 40°C\/min (1°C increments)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q4c1us\" data-start=\"2761\" data-end=\"2829\"\u003e\n\u003cp data-start=\"2763\" data-end=\"2829\"\u003e\u003cstrong data-start=\"2763\" data-end=\"2781\"\u003eProgram Ramps:\u003c\/strong\u003e 7 ramps standard (up to 10 ramps with software)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"2831\" data-end=\"2845\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2846\" data-end=\"2950\"\u003e\n\u003cli data-section-id=\"xyrg16\" data-start=\"2846\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2848\" data-end=\"2897\"\u003e\u003cstrong data-start=\"2848\" data-end=\"2876\"\u003eInside Size (L × W × H):\u003c\/strong\u003e 284 × 280 × 241 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2go6ku\" data-start=\"2898\" data-end=\"2950\"\u003e\n\u003cp data-start=\"2900\" data-end=\"2950\"\u003e\u003cstrong data-start=\"2900\" data-end=\"2929\"\u003eOutside Size (L × W × H):\u003c\/strong\u003e 340 × 345 × 281 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2952\" data-end=\"2955\"\u003e\n\u003ch3 data-section-id=\"ilb2ut\" data-start=\"2957\" data-end=\"2974\"\u003eDetector (FID)\u003c\/h3\u003e\n\u003cul data-start=\"2975\" data-end=\"3084\"\u003e\n\u003cli data-section-id=\"ozss9u\" data-start=\"2975\" data-end=\"3015\"\u003e\n\u003cp data-start=\"2977\" data-end=\"3015\"\u003e\u003cstrong data-start=\"2977\" data-end=\"2997\"\u003eDetection Limit:\u003c\/strong\u003e ≤ 3 × 10⁻¹² g\/s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2pmxpp\" data-start=\"3016\" data-end=\"3053\"\u003e\n\u003cp data-start=\"3018\" data-end=\"3053\"\u003e\u003cstrong data-start=\"3018\" data-end=\"3028\"\u003eDrift:\u003c\/strong\u003e ≤ 6 × 10⁻¹³ A \/ 30 min\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16k2fdy\" data-start=\"3054\" data-end=\"3084\"\u003e\n\u003cp data-start=\"3056\" data-end=\"3084\"\u003e\u003cstrong data-start=\"3056\" data-end=\"3076\"\u003eLinearity Range:\u003c\/strong\u003e ≥ 10⁶\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3086\" data-end=\"3089\"\u003e\n\u003ch3 data-section-id=\"4u3vl2\" data-start=\"3091\" data-end=\"3120\"\u003eSample Introduction System\u003c\/h3\u003e\n\u003cul data-start=\"3121\" data-end=\"3143\"\u003e\n\u003cli data-section-id=\"e1w0gr\" data-start=\"3121\" data-end=\"3143\"\u003e\n\u003cp data-start=\"3123\" data-end=\"3143\"\u003eCapillary injector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3145\" data-end=\"3148\"\u003e\n\u003ch3 data-section-id=\"1ptu1li\" data-start=\"3150\" data-end=\"3171\"\u003ePower Requirements\u003c\/h3\u003e\n\u003cul data-start=\"3172\" data-end=\"3229\"\u003e\n\u003cli data-section-id=\"eflijc\" data-start=\"3172\" data-end=\"3193\"\u003e\n\u003cp data-start=\"3174\" data-end=\"3193\"\u003e\u003cstrong data-start=\"3174\" data-end=\"3184\"\u003ePower:\u003c\/strong\u003e 2000 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wppeww\" data-start=\"3194\" data-end=\"3229\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3229\"\u003e\u003cstrong data-start=\"3196\" data-end=\"3213\"\u003ePower Supply:\u003c\/strong\u003e 220 V \/ 50 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3231\" data-end=\"3234\"\u003e\n\u003ch3 data-section-id=\"1fltwr4\" data-start=\"3236\" data-end=\"3258\"\u003ePacking Information\u003c\/h3\u003e\n\u003cul data-start=\"3259\" data-end=\"3337\"\u003e\n\u003cli data-section-id=\"uqh0z7\" data-start=\"3259\" data-end=\"3299\"\u003e\n\u003cp data-start=\"3261\" data-end=\"3299\"\u003e\u003cstrong data-start=\"3261\" data-end=\"3278\"\u003ePacking Size:\u003c\/strong\u003e 830 × 680 × 855 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kt2hlt\" data-start=\"3300\" data-end=\"3337\"\u003e\n\u003cp data-start=\"3302\" data-end=\"3337\"\u003e\u003cstrong data-start=\"3302\" data-end=\"3329\"\u003eGross Weight (Approx.):\u003c\/strong\u003e 79 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3339\" data-end=\"3342\"\u003e\n\u003ch3 data-section-id=\"uoahhp\" data-start=\"3344\" data-end=\"3367\"\u003eOptional Accessories\u003c\/h3\u003e\n\u003cul data-start=\"3368\" data-end=\"3440\"\u003e\n\u003cli data-section-id=\"x00mvz\" data-start=\"3368\" data-end=\"3396\"\u003e\n\u003cp data-start=\"3370\" data-end=\"3396\"\u003e\u003cstrong data-start=\"3370\" data-end=\"3387\"\u003eAuto Sampler:\u003c\/strong\u003e ASGC22\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xicf9r\" data-start=\"3397\" data-end=\"3440\"\u003e\n\u003cp data-start=\"3399\" data-end=\"3440\"\u003e\u003cstrong data-start=\"3399\" data-end=\"3440\"\u003eAir source \/ flow rate control device\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52797919985961,"sku":"GC10CI","price":489000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/GC10CI.jpg?v=1777055111"},{"product_id":"gas-chromatography-1","title":"Gas chromatography I Advanced GC System with EPC \u0026 FID Detector I GLP\/FDA\/CFR Part 11 Complaint","description":"\u003cp data-end=\"501\" data-start=\"75\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"108\" data-start=\"79\"\u003eGas Chromatography GC99SI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eavailable at\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analytical instrument designed for precise separation and analysis of volatile organic compounds (VOCs). Built with advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"345\" data-start=\"307\"\u003eElectronic Pneumatic Control (EPC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"404\" data-start=\"352\"\u003ehigh-sensitivity Flame Ionization Detector (FID)\u003c\/strong\u003e, this system is ideal for laboratories requiring accuracy, compliance, and reliable performance.\u003c\/p\u003e\n\u003ch2 data-end=\"367\" data-start=\"349\" data-section-id=\"iy0zl5\"\u003eSALIENT FEATURES\u003c\/h2\u003e\n\u003cul data-end=\"1186\" data-start=\"368\"\u003e\n\u003cli data-end=\"413\" data-start=\"368\" data-section-id=\"1l7yvpt\"\u003e\n\u003cp data-end=\"413\" data-start=\"370\"\u003eEPC – Electronic Pneumatic Control system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"445\" data-start=\"414\" data-section-id=\"puu1k0\"\u003e\n\u003cp data-end=\"445\" data-start=\"416\"\u003e7 inch touch screen display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"536\" data-start=\"446\" data-section-id=\"15tkyce\"\u003e\n\u003cp data-end=\"536\" data-start=\"448\"\u003eControl system designed for monitoring and controlling the instrument through computer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"642\" data-start=\"537\" data-section-id=\"dkcyz2\"\u003e\n\u003cp data-end=\"582\" data-start=\"539\"\u003eMultistage programmed temperature control\u003c\/p\u003e\n\u003cul data-end=\"642\" data-start=\"585\"\u003e\n\u003cli data-end=\"613\" data-start=\"585\" data-section-id=\"w48kqo\"\u003e\n\u003cp data-end=\"613\" data-start=\"587\"\u003e20 ramps with instrument\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"642\" data-start=\"616\" data-section-id=\"1xbgqmw\"\u003e\n\u003cp data-end=\"642\" data-start=\"618\"\u003e99 ramps with software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"776\" data-start=\"643\" data-section-id=\"djguxl\"\u003e\n\u003cp data-end=\"776\" data-start=\"645\"\u003eAdvanced built-in data acquisition system supporting real-time instrument monitoring, detection signal acquisition and PC control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"875\" data-start=\"777\" data-section-id=\"f0ay70\"\u003e\n\u003cp data-end=\"875\" data-start=\"779\"\u003eColumn oven supports quick heat-up and rapid cool-down with automated inside back-door opening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"935\" data-start=\"876\" data-section-id=\"1f3qx2c\"\u003e\n\u003cp data-end=\"935\" data-start=\"878\"\u003eSample introduction system: 1 sample injector installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1054\" data-start=\"936\" data-section-id=\"fjojmz\"\u003e\n\u003cp data-end=\"1054\" data-start=\"938\"\u003eSample detection system: High sensitivity and stability \u003cstrong data-end=\"1010\" data-start=\"994\"\u003eFID detector\u003c\/strong\u003e for various organic compound applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1083\" data-start=\"1055\" data-section-id=\"1jbqbk7\"\u003e\n\u003cp data-end=\"1083\" data-start=\"1057\"\u003eOne analog signal output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1186\" data-start=\"1084\" data-section-id=\"yyh1p3\"\u003e\n\u003cp data-end=\"1186\" data-start=\"1086\"\u003eSoftware compatible with \u003cstrong data-end=\"1137\" data-start=\"1111\"\u003eGLP\/FDA-21 CFR Part 11\u003c\/strong\u003e requirements (electronic records and signatures)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1191\" data-start=\"1188\"\u003e\n\u003ch1 data-end=\"1220\" data-start=\"1193\" data-section-id=\"1wduzrt\"\u003eGas Chromatography GC99SI\u003c\/h1\u003e\n\u003cp data-end=\"1289\" data-start=\"1221\"\u003eMicroprocessor technology with EPC system and touchscreen interface.\u003c\/p\u003e\n\u003cp data-end=\"1300\" data-start=\"1291\"\u003eIncludes:\u003c\/p\u003e\n\u003cul data-end=\"1362\" data-start=\"1301\"\u003e\n\u003cli data-end=\"1327\" data-start=\"1301\" data-section-id=\"6aqgph\"\u003e\n\u003cp data-end=\"1327\" data-start=\"1303\"\u003eCapillary column inlet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1344\" data-start=\"1328\" data-section-id=\"1odkyft\"\u003e\n\u003cp data-end=\"1344\" data-start=\"1330\"\u003eFID detector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1362\" data-start=\"1345\" data-section-id=\"171po2q\"\u003e\n\u003cp data-end=\"1362\" data-start=\"1347\"\u003eSoftware system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1374\" data-start=\"1364\"\u003eFunctions:\u003c\/p\u003e\n\u003cul data-end=\"1755\" data-start=\"1375\"\u003e\n\u003cli data-end=\"1423\" data-start=\"1375\" data-section-id=\"or8wtx\"\u003e\n\u003cp data-end=\"1423\" data-start=\"1377\"\u003eInstrument monitoring and control through PC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1510\" data-start=\"1424\" data-section-id=\"j4neaj\"\u003e\n\u003cp data-end=\"1510\" data-start=\"1426\"\u003eColumn oven with superior thermal performance and programmable temperature control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1601\" data-start=\"1511\" data-section-id=\"10dyclw\"\u003e\n\u003cp data-end=\"1601\" data-start=\"1513\"\u003eBuilt-in data acquisition system for instrument status monitoring and signal detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1671\" data-start=\"1602\" data-section-id=\"199e8ro\"\u003e\n\u003cp data-end=\"1671\" data-start=\"1604\"\u003eQuick heat-up and cool-down oven with automated back-door opening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1702\" data-start=\"1672\" data-section-id=\"4uj0do\"\u003e\n\u003cp data-end=\"1702\" data-start=\"1674\"\u003eDual analog output signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1755\" data-start=\"1703\" data-section-id=\"104r2p5\"\u003e\n\u003cp data-end=\"1755\" data-start=\"1705\"\u003ePC software compatible with GLP\/FDA-21 CFR Part 11\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1760\" data-start=\"1757\"\u003e\n\u003ch1 data-end=\"1799\" data-start=\"1762\" data-section-id=\"1sw4p2y\"\u003eElectronic Pneumatic Control System\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2023\" data-start=\"1801\"\u003e\n\u003cthead data-end=\"1822\" data-start=\"1801\"\u003e\n\u003ctr data-end=\"1822\" data-start=\"1801\"\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"1813\" data-start=\"1801\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"1822\" data-start=\"1813\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2023\" data-start=\"1833\"\u003e\n\u003ctr data-end=\"1882\" data-start=\"1833\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1845\" data-start=\"1833\"\u003eFlow rate\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1882\" data-start=\"1845\"\u003e200 ml\/min (N₂), 1000 ml\/min (He)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1911\" data-start=\"1883\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1904\" data-start=\"1883\"\u003eFlow rate accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1911\" data-start=\"1904\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1948\" data-start=\"1912\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1938\" data-start=\"1912\"\u003eFlow rate repeatability\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1948\" data-start=\"1938\"\u003e±0.35%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1991\" data-start=\"1949\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1963\" data-start=\"1949\"\u003eSplit ratio\u003c\/td\u003e\n\u003ctd data-end=\"1991\" data-start=\"1963\" data-col-size=\"sm\"\u003e0–5000 (He), 0–1000 (N₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2023\" data-start=\"1992\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2012\" data-start=\"1992\"\u003eInlet temperature\u003c\/td\u003e\n\u003ctd data-end=\"2023\" data-start=\"2012\" data-col-size=\"sm\"\u003e0–420°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2028\" data-start=\"2025\"\u003e\n\u003ch1 data-end=\"2060\" data-start=\"2030\" data-section-id=\"g5ib4n\"\u003eApplications of FID Detector\u003c\/h1\u003e\n\u003cp data-end=\"2082\" data-start=\"2061\"\u003eUsed for analysis of:\u003c\/p\u003e\n\u003cul data-end=\"2384\" data-start=\"2084\"\u003e\n\u003cli data-end=\"2139\" data-start=\"2084\" data-section-id=\"560b08\"\u003e\n\u003cp data-end=\"2139\" data-start=\"2086\"\u003eNitrobenzene compounds (nitrobenzene, dinitrotoluene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2216\" data-start=\"2140\" data-section-id=\"14os5i1\"\u003e\n\u003cp data-end=\"2216\" data-start=\"2142\"\u003eChlorobenzene compounds (chlorobenzene, dichlorobenzene, trichlorobenzene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2304\" data-start=\"2217\" data-section-id=\"1m9mj15\"\u003e\n\u003cp data-end=\"2304\" data-start=\"2219\"\u003eBenzene series (toluene, ethylbenzene, o-xylene, m-xylene, p-xylene, styrene, cumene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2346\" data-start=\"2305\" data-section-id=\"p48xvs\"\u003e\n\u003cp data-end=\"2346\" data-start=\"2307\"\u003eTVOC (Total Volatile Organic Compounds)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2384\" data-start=\"2347\" data-section-id=\"1fwxk1l\"\u003e\n\u003cp data-end=\"2384\" data-start=\"2349\"\u003ePhenolic compounds (phenol, cresol)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2450\" data-start=\"2386\"\u003eAdditional accessories may be required depending on application:\u003c\/p\u003e\n\u003cul data-end=\"2500\" data-start=\"2451\"\u003e\n\u003cli data-end=\"2470\" data-start=\"2451\" data-section-id=\"b0pdv4\"\u003e\n\u003cp data-end=\"2470\" data-start=\"2453\"\u003eHeadspace sampler\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2500\" data-start=\"2471\" data-section-id=\"lc2t5w\"\u003e\n\u003cp data-end=\"2500\" data-start=\"2473\"\u003eThermal analysis instrument\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2505\" data-start=\"2502\"\u003e\n\u003ch1 data-end=\"2546\" data-start=\"2507\" data-section-id=\"rynrwn\"\u003eAdvanced Microcomputer Control System\u003c\/h1\u003e\n\u003cp data-end=\"2557\" data-start=\"2548\"\u003eFeatures:\u003c\/p\u003e\n\u003cul data-end=\"2908\" data-start=\"2558\"\u003e\n\u003cli data-end=\"2612\" data-start=\"2558\" data-section-id=\"1x9omn7\"\u003e\n\u003cp data-end=\"2612\" data-start=\"2560\"\u003eAdvanced computer-based temperature control system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2652\" data-start=\"2613\" data-section-id=\"2v3n8o\"\u003e\n\u003cp data-end=\"2652\" data-start=\"2615\"\u003eHigh temperature accuracy (±0.02°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2702\" data-start=\"2653\" data-section-id=\"771r6w\"\u003e\n\u003cp data-end=\"2702\" data-start=\"2655\"\u003eHigh reliability and anti-interference design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2804\" data-start=\"2703\" data-section-id=\"jw5p3t\"\u003e\n\u003cp data-end=\"2751\" data-start=\"2705\"\u003eSelf-diagnosis and self-protection functions\u003c\/p\u003e\n\u003cul data-end=\"2804\" data-start=\"2754\"\u003e\n\u003cli data-end=\"2777\" data-start=\"2754\" data-section-id=\"1ivqwvx\"\u003e\n\u003cp data-end=\"2777\" data-start=\"2756\"\u003eOverheat protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2804\" data-start=\"2780\" data-section-id=\"1t6wn92\"\u003e\n\u003cp data-end=\"2804\" data-start=\"2782\"\u003ePower-off protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2908\" data-start=\"2805\" data-section-id=\"1rdwa2a\"\u003e\n\u003cp data-end=\"2818\" data-start=\"2807\"\u003eDisplay of:\u003c\/p\u003e\n\u003cul data-end=\"2908\" data-start=\"2821\"\u003e\n\u003cli data-end=\"2839\" data-start=\"2821\" data-section-id=\"p586k\"\u003e\n\u003cp data-end=\"2839\" data-start=\"2823\"\u003eTiming program\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2861\" data-start=\"2842\" data-section-id=\"4zpuva\"\u003e\n\u003cp data-end=\"2861\" data-start=\"2844\"\u003eDetector status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2885\" data-start=\"2864\" data-section-id=\"189ryot\"\u003e\n\u003cp data-end=\"2885\" data-start=\"2866\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2908\" data-start=\"2888\" data-section-id=\"30gmn8\"\u003e\n\u003cp data-end=\"2908\" data-start=\"2890\"\u003eCurrent settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2962\" data-start=\"2910\"\u003eNote: \u003cstrong data-end=\"2962\" data-start=\"2916\"\u003eComputer not included with the instrument.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"2962\" data-start=\"2910\"\u003e\u003cstrong data-end=\"2962\" data-start=\"2916\"\u003eSPECIFICATIONS.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGC99SI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake\u003c\/td\u003e\n\u003ctd\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSN Code\u003c\/td\u003e\n\u003ctd\u003e90272000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003eEPC (Electronic Pneumatic Control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Introduction\u003c\/td\u003e\n\u003ctd\u003eSplit \/ Splitless Injector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetector – FID\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Limit\u003c\/td\u003e\n\u003ctd\u003e≤ 8 × 10⁻¹² g\/s (n-hexadecane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5 × 10⁻¹³ A\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise\u003c\/td\u003e\n\u003ctd\u003e≤ 3 × 10⁻¹⁴ A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Range\u003c\/td\u003e\n\u003ctd\u003e≥ 10⁶\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Temperature\u003c\/td\u003e\n\u003ctd\u003e400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e≥ 10000 mV·ml\/mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Noise\u003c\/td\u003e\n\u003ctd\u003e≤ 20 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Drift\u003c\/td\u003e\n\u003ctd\u003e≤ 100 µV \/ 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Size\u003c\/td\u003e\n\u003ctd\u003e835 × 770 × 930 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 88 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1 data-end=\"4283\" data-start=\"4261\" data-section-id=\"1ogiurf\"\u003eStandard Accessories\u003c\/h1\u003e\n\u003cul data-end=\"4363\" data-start=\"4285\"\u003e\n\u003cli data-end=\"4304\" data-start=\"4285\" data-section-id=\"1s843km\"\u003e\n\u003cp data-end=\"4304\" data-start=\"4287\"\u003eMain Instrument\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4319\" data-start=\"4305\" data-section-id=\"ouvzcd\"\u003e\n\u003cp data-end=\"4319\" data-start=\"4307\"\u003ePower Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4342\" data-start=\"4320\" data-section-id=\"6icai2\"\u003e\n\u003cp data-end=\"4342\" data-start=\"4322\"\u003eInstruction Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4363\" data-start=\"4343\" data-section-id=\"172qrnv\"\u003e\n\u003cp data-end=\"4363\" data-start=\"4345\"\u003eTest Certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"4368\" data-start=\"4365\"\u003e\n\u003ch3 data-end=\"4392\" data-start=\"4370\" data-section-id=\"yknlu6\"\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"4463\" data-start=\"4394\"\u003e\n\u003cli data-end=\"4421\" data-start=\"4394\" data-section-id=\"1kos1fp\"\u003e\n\u003cp data-end=\"4421\" data-start=\"4396\"\u003eAuto Sampler \u003cstrong data-end=\"4419\" data-start=\"4409\"\u003eASGC22\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4463\" data-start=\"4422\" data-section-id=\"1krnntb\"\u003e\n\u003cp data-end=\"4463\" data-start=\"4424\"\u003eAir source \/ flow rate control device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"4099\" data-start=\"4096\"\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52797977198889,"sku":"GC99SI","price":829999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/qt_q_55.jpg?v=1777055051"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/collections\/GC10CI-3570827.webp?v=1777305670","url":"https:\/\/www.labmart.in\/collections\/gas-chromatography.oembed","provider":"Labmart.in","version":"1.0","type":"link"}