{"title":"Chromatography instruments","description":"\u003ch2 data-section-id=\"3yl1z7\" data-start=\"122\" data-end=\"201\"\u003e🧪 Chromatography Instruments – Buy Chromatography Equipment Online in India\u003c\/h2\u003e\n\u003cp data-start=\"203\" data-end=\"785\"\u003eExplore a comprehensive range of \u003cstrong data-start=\"236\" data-end=\"275\"\u003echromatography instruments in India\u003c\/strong\u003e at \u003cstrong data-start=\"279\" data-end=\"290\"\u003eLabmart\u003c\/strong\u003e, designed for \u003cstrong data-start=\"305\" data-end=\"391\"\u003eseparation, identification, and analysis of chemical compounds in complex mixtures\u003c\/strong\u003e. Our collection includes \u003cstrong data-start=\"417\" data-end=\"616\"\u003egas chromatography (GC) systems, high-performance liquid chromatography (HPLC) systems, thin layer chromatography (TLC) kits, column chromatography setups, chromatography columns, and accessories\u003c\/strong\u003e, ideal for \u003cstrong data-start=\"628\" data-end=\"784\"\u003epharmaceutical industries, chemical laboratories, research institutes, environmental testing labs, food \u0026amp; beverage industries, and academic institutions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"787\" data-end=\"1134\"\u003eLabmart offers \u003cstrong data-start=\"802\" data-end=\"850\"\u003ehigh-quality chromatography equipment online\u003c\/strong\u003e that ensures \u003cstrong data-start=\"864\" data-end=\"940\"\u003ehigh precision, accurate separation, and reliable analytical performance\u003c\/strong\u003e. These instruments are essential for \u003cstrong data-start=\"978\" data-end=\"1066\"\u003ecompound identification, purity analysis, quality control, and research applications\u003c\/strong\u003e, making them indispensable tools in modern analytical laboratories.\u003c\/p\u003e\n\u003cp data-start=\"1136\" data-end=\"1337\"\u003eWhether you need a \u003cstrong data-start=\"1155\" data-end=\"1263\"\u003ebasic TLC setup for routine analysis or an advanced HPLC system for research and industrial applications\u003c\/strong\u003e, Labmart provides \u003cstrong data-start=\"1282\" data-end=\"1336\"\u003edurable, efficient, and high-performance solutions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1339\" data-end=\"1342\"\u003e\n\u003ch2 data-section-id=\"y865nw\" data-start=\"1344\" data-end=\"1414\"\u003e🔑 Why Labmart.in is the Go-To Place for Chromatography Instruments\u003c\/h2\u003e\n\u003cul data-start=\"1416\" data-end=\"1892\"\u003e\n\u003cli data-section-id=\"1sizg62\" data-start=\"1416\" data-end=\"1478\"\u003e✔ Wide range of \u003cstrong data-start=\"1434\" data-end=\"1476\"\u003echromatography systems and accessories\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ujo8y7\" data-start=\"1479\" data-end=\"1540\"\u003e✔ High precision for \u003cstrong data-start=\"1502\" data-end=\"1538\"\u003ecompound separation and analysis\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nrioi6\" data-start=\"1541\" data-end=\"1615\"\u003e✔ Suitable for \u003cstrong data-start=\"1558\" data-end=\"1613\"\u003epharmaceutical, chemical, and research applications\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j1ohpu\" data-start=\"1616\" data-end=\"1683\"\u003e✔ Advanced technology for \u003cstrong data-start=\"1644\" data-end=\"1681\"\u003eaccurate and reproducible results\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4q565k\" data-start=\"1684\" data-end=\"1761\"\u003e✔ Competitive pricing for \u003cstrong data-start=\"1712\" data-end=\"1759\"\u003elabs, industries, and institutions in India\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dv9f4l\" data-start=\"1762\" data-end=\"1827\"\u003e✔ Trusted supplier of \u003cstrong data-start=\"1786\" data-end=\"1825\"\u003escientific and laboratory equipment\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uu543w\" data-start=\"1828\" data-end=\"1892\"\u003e✔ Reliable support and seamless online purchasing experience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1894\" data-end=\"2056\"\u003eLabmart.in is a \u003cstrong data-start=\"1910\" data-end=\"1983\"\u003etrusted destination to buy chromatography instruments online in India\u003c\/strong\u003e, offering dependable solutions for analytical and research laboratories.\u003c\/p\u003e\n\u003chr data-start=\"2058\" data-end=\"2061\"\u003e\n\u003ch2 data-section-id=\"1xz0ebn\" data-start=\"2063\" data-end=\"2111\"\u003e🧪 Applications of Chromatography Instruments\u003c\/h2\u003e\n\u003cp data-start=\"2113\" data-end=\"2159\"\u003eChromatography instruments are widely used in:\u003c\/p\u003e\n\u003cul data-start=\"2161\" data-end=\"2678\"\u003e\n\u003cli data-section-id=\"1dsqcjr\" data-start=\"2161\" data-end=\"2234\"\u003e💊 \u003cstrong data-start=\"2166\" data-end=\"2193\"\u003ePharmaceutical Industry\u003c\/strong\u003e – Drug development and quality control\u003c\/li\u003e\n\u003cli data-section-id=\"xstpc4\" data-start=\"2235\" data-end=\"2306\"\u003e🧪 \u003cstrong data-start=\"2240\" data-end=\"2265\"\u003eChemical Laboratories\u003c\/strong\u003e – Separation and analysis of compounds\u003c\/li\u003e\n\u003cli data-section-id=\"1c8yk8m\" data-start=\"2307\" data-end=\"2382\"\u003e🌱 \u003cstrong data-start=\"2312\" data-end=\"2337\"\u003eEnvironmental Testing\u003c\/strong\u003e – Detection of pollutants and contaminants\u003c\/li\u003e\n\u003cli data-section-id=\"z9aosr\" data-start=\"2383\" data-end=\"2456\"\u003e🧫 \u003cstrong data-start=\"2388\" data-end=\"2416\"\u003eFood \u0026amp; Beverage Industry\u003c\/strong\u003e – Quality testing and safety analysis\u003c\/li\u003e\n\u003cli data-section-id=\"18xznss\" data-start=\"2457\" data-end=\"2526\"\u003e🔬 \u003cstrong data-start=\"2462\" data-end=\"2487\"\u003eResearch Laboratories\u003c\/strong\u003e – Analytical and biochemical studies\u003c\/li\u003e\n\u003cli data-section-id=\"96kgq2\" data-start=\"2527\" data-end=\"2604\"\u003e🏭 \u003cstrong data-start=\"2532\" data-end=\"2559\"\u003eIndustrial Applications\u003c\/strong\u003e – Process monitoring and quality assurance\u003c\/li\u003e\n\u003cli data-section-id=\"o27231\" data-start=\"2605\" data-end=\"2678\"\u003e🏫 \u003cstrong data-start=\"2610\" data-end=\"2638\"\u003eEducational Institutions\u003c\/strong\u003e – Teaching and laboratory experiments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2680\" data-end=\"2683\"\u003e\n\u003ch2 data-section-id=\"ietzmw\" data-start=\"2685\" data-end=\"2723\"\u003e❓ Frequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1jlvn48\" data-start=\"2725\" data-end=\"2768\"\u003e1. What are chromatography instruments?\u003c\/h3\u003e\n\u003cp data-start=\"2769\" data-end=\"2899\"\u003eChromatography instruments are \u003cstrong data-start=\"2800\" data-end=\"2898\"\u003edevices used to separate and analyze components of mixtures based on their chemical properties\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"xit1w0\" data-start=\"2901\" data-end=\"2970\"\u003e2. What types of chromatography systems are available at Labmart?\u003c\/h3\u003e\n\u003cp data-start=\"2971\" data-end=\"3059\"\u003eLabmart offers \u003cstrong data-start=\"2986\" data-end=\"3058\"\u003eGC systems, HPLC systems, TLC kits, and column chromatography setups\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hjwyqk\" data-start=\"3061\" data-end=\"3100\"\u003e3. What is chromatography used for?\u003c\/h3\u003e\n\u003cp data-start=\"3101\" data-end=\"3177\"\u003eIt is used for \u003cstrong data-start=\"3116\" data-end=\"3176\"\u003ecompound separation, identification, and purity analysis\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"oog8q9\" data-start=\"3179\" data-end=\"3252\"\u003e4. Are chromatography instruments suitable for research laboratories?\u003c\/h3\u003e\n\u003cp data-start=\"3253\" data-end=\"3338\"\u003eYes, they are widely used in \u003cstrong data-start=\"3282\" data-end=\"3337\"\u003epharmaceutical, chemical, and research applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1x28qmz\" data-start=\"3340\" data-end=\"3393\"\u003e5. Do chromatography systems require maintenance?\u003c\/h3\u003e\n\u003cp data-start=\"3394\" data-end=\"3465\"\u003eYes, regular maintenance ensures \u003cstrong data-start=\"3427\" data-end=\"3464\"\u003eaccurate and reliable performance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"747gch\" data-start=\"3467\" data-end=\"3534\"\u003e6. Why should I buy chromatography instruments from Labmart.in?\u003c\/h3\u003e\n\u003cp data-start=\"3535\" data-end=\"3666\"\u003eLabmart offers \u003cstrong data-start=\"3550\" data-end=\"3637\"\u003ehigh-quality equipment, competitive pricing, reliable support, and a wide selection\u003c\/strong\u003e, making it a trusted choice.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1sxa8j5\" data-start=\"3668\" data-end=\"3727\"\u003e7. Can chromatography be used in environmental testing?\u003c\/h3\u003e\n\u003cp data-start=\"3728\" data-end=\"3824\"\u003eYes, it is commonly used for \u003cstrong data-start=\"3757\" data-end=\"3823\"\u003edetecting pollutants and contaminants in environmental samples\u003c\/strong\u003e.\u003c\/p\u003e","products":[{"product_id":"high-performance-liquid-chromatography-hplc-li-6200","title":"High-Performance Liquid Chromatography – HPLC LI-6200","description":"\u003cp\u003e\u003cspan\u003eHigh-Performance Liquid Chromatography (HPLC) is a powerful analytical technique used to separate, identify, and quantify components in a mixture. The LI-6200 is a specific model of an HPLC system, known for its high sensitivity and precision.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHPLC operates by passing a liquid sample through a column filled with a solid adsorbent material. Each component in the sample interacts differently with the adsorbent material, leading to different flow rates for each component and, thus, separation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eComponents of HPLC:\u003c\/span\u003e\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePump\u003c\/strong\u003e: Moves the mobile phase through the column at a high pressure.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInjector\u003c\/strong\u003e: Introduces the liquid sample into the flow stream of the mobile phase.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eColumn\u003c\/strong\u003e: Contains the stationary phase where the separation of components occurs.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDetector\u003c\/strong\u003e: Identifies and quantifies the separated components as they elute from the column.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eData System\u003c\/strong\u003e: Records and analyzes the output from the detector.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e\u003cspan\u003eApplications:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePharmaceutical analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFood and beverage quality control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnvironmental monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBiochemical research\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003eFeatures:\u003c\/span\u003e\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh Sensitivity\u003c\/strong\u003e: The LI-6200 is designed to detect and measure low concentrations of sample components with high precision.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRobust Pump System\u003c\/strong\u003e: Ensures consistent and accurate delivery of the mobile phase, essential for reproducible results.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eVersatile Injector\u003c\/strong\u003e: Capable of handling a wide range of sample types and volumes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEfficient Column Design\u003c\/strong\u003e: Optimizes separation efficiency, providing sharp and well-defined peaks.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eAdvanced Detector\u003c\/strong\u003e: Equipped with multiple detection methods, such as UV, PDA, or fluorescence, enhancing the system’s ability to handle diverse analytical requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eUser-Friendly Software\u003c\/strong\u003e: Facilitates easy control and monitoring of the HPLC process, along with comprehensive data analysis and reporting.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e\u003cspan\u003eBenefits:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh Throughput\u003c\/strong\u003e: Rapid analysis and quick turnaround times for sample processing.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePrecision and Accuracy\u003c\/strong\u003e: Reliable quantification and identification of sample components.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Suitable for a wide range of applications, from simple to complex analyses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDurability\u003c\/strong\u003e: Built to withstand rigorous laboratory environments and continuous operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003eCommon Uses:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eQuality control in pharmaceutical production\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTesting for contaminants in food and water samples\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalyzing biochemical samples in research labs\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003eSalient Features\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e• Self-priming pump head requires no manual priming\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Patented “Floating Pump Seal” designed for extended seal wear\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Available with micro, analytical, semi-prep, and prep pump heads\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Programmable solvent compressibility compensation\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Easy maintenance and service for all wetted parts\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Integral prime\/purge assembly for quick solvent change\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e• Injector\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Micro syringe\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Column C18\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Software CD\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Filter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lasany","offers":[{"title":"Default Title","offer_id":50518367633705,"sku":"LI-6200","price":500000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/li-6200.webp?v=1777307775"},{"product_id":"hplc-system-with-rheodyne-injector-model-no-li-6210","title":"HPLC System With Rheodyne Injector (Model No: LI-6210)","description":"\u003cp\u003e\u003cspan\u003eHPLC (High-Performance Liquid Chromatography) system with a Rheodyne injector (Model No: LI-6210) is a sophisticated analytical instrument widely used in scientific laboratories, particularly in chemistry, biochemistry, pharmaceuticals, and related fields. Here’s a comprehensive description of its components and functionalities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh-Performance Liquid Chromatography (HPLC) System\u003c\/strong\u003e: HPLC is a powerful analytical technique used to separate, identify, and quantify components in a mixture. It utilizes high-pressure pumps to push a liquid solvent (mobile phase) through a column packed with a stationary phase, where the sample components interact differently, leading to separation based on their various properties such as size, polarity, or charge.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRheodyne Injector (Model No: LI-6210)\u003c\/strong\u003e: The Rheodyne injector is a crucial component of the HPLC system responsible for introducing the sample into the chromatographic system. Model LI-6210 is a specific version of the Rheodyne injector, likely with certain specifications and features unique to this model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e: The Rheodyne injector typically features a rotor with multiple ports where samples are loaded. It employs a highly precise mechanism to inject a fixed volume of the sample into the flowing mobile phase without altering its composition or introducing air bubbles.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInjection Precision\u003c\/strong\u003e: The LI-6210 model likely offers exceptional injection precision, ensuring accurate and reproducible results even for trace-level analyses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: It’s designed to be compatible with a wide range of HPLC systems and columns, offering versatility in applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003eKey Components\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePump(s)\u003c\/strong\u003e: The HPLC system includes one or more high-pressure pumps responsible for delivering the mobile phase at a constant flow rate and pressure.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eColumn\u003c\/strong\u003e: The heart of the chromatographic separation, where the actual separation of sample components occurs based on their interaction with the stationary phase.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDetector(s)\u003c\/strong\u003e: These devices monitor the effluent from the column and detect the separated sample components, typically employing techniques such as UV-Vis spectroscopy, fluorescence, or mass spectrometry.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eData Acquisition System\u003c\/strong\u003e: This system records and analyzes the signals from the detector(s), generating chromatograms that represent the separation of sample components over time.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePharmaceutical Analysis\u003c\/strong\u003e: Used for quality control, purity assessment, and quantification of active pharmaceutical ingredients (APIs) and impurities.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Monitoring\u003c\/strong\u003e: Detecting and quantifying pollutants, pesticides, and other contaminants in environmental samples.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eFood and Beverage Analysis\u003c\/strong\u003e: Identifying and quantifying additives, pesticides, and other compounds in food and beverage products.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eBiomedical Research\u003c\/strong\u003e: Studying biomolecules such as proteins, peptides, nucleic acids, and metabolites for various research purposes.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003eFeatures : \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eInfusion Way                           Series dual plunger\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eFlow Rates                             0.001 ~10.000ml\/min\u003cbr\u003epump Pressure Accuracy        ± 2%\u003cbr\u003ePressure                                 0 – 6000 psi\u003cbr\u003ePulsation                              \u0026lt;15psi from 600 to 1,600 psi,  Flow 1mL\/min\u003cbr\u003eDimensions                          170H x 260W x 360D, (mm)\u003cbr\u003eFlow Accuracy                      ≤±1 %(2μL\/min)\u003cbr\u003eFlow Precision                      0.1%\u003cbr\u003eOperating  Temperature        4~40°C\u003cbr\u003eWeight.                                  (6.3 kg)\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications (UV-Detector)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWavelength                               190-700 nm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eWavelength Accuracy              ≤±1 nm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eWavelength Reproducibility    ≤± 0.5 nm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eQualitative Repeatability        RSD ≤ 0.1%\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDimensions                            160H x 260W x 350 D, (mm)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eOperating Temperature          4-40°C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSpectral bandwidth                 6 nm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eFlow pool volume                   10 μ L\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eOptical path                           10 mm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eStatic Noise                          ≤± 1×10 AU (Empty pool, Response time  1 s, 20 °C)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eStatic Drifting ≤± 1×10 AU     (Empty pool,Response time 1 s, 20 °C)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eQuantitative repeatability        RSD ≤ 0.5%\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eWeight.                                    6kg\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMinimum detection concentration    ≤1×10- 8g\/mL(Naphthalene\/methanol solution\u003c\/span\u003e\u003c\/p\u003e","brand":"Lasany","offers":[{"title":"Default Title","offer_id":50518374416681,"sku":"LI-6210","price":635000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/li-6200_1.webp?v=1777307183"},{"product_id":"high-performance-liquid-chromatography-advanced-hplc-li-6300","title":"High-Performance Liquid Chromatography Advanced (HPLC LI-6300)","description":"\u003cp\u003e\u003cspan\u003eHPLC is a technique in analytical chemistry used to separate, identify, and quantify each component in a mixture. It relies on pumps to pass a pressurized liquid solvent containing the sample mixture through a column filled with a solid adsorbent material. Each component in the sample interacts slightly differently with the adsorbent material, causing different flow rates for the different components and leading to their separation as they flow out of the column.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eKey Components\u003c\/span\u003e\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSolvent Reservoirs:\u003c\/strong\u003e Hold the mobile phase solvents.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePump:\u003c\/strong\u003e Delivers the mobile phase at a high pressure to the system.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInjector:\u003c\/strong\u003e Introduces the sample into the mobile phase stream.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eColumn:\u003c\/strong\u003e Packed with stationary phase material where separation occurs.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDetector:\u003c\/strong\u003e Identifies and quantifies the components as they elute from the column.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eData System:\u003c\/strong\u003e Collects and analyzes the data.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e\u003cspan\u003eWorking Principle\u003c\/span\u003e\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInjection:\u003c\/strong\u003e The sample mixture is injected into the mobile phase stream.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSeparation:\u003c\/strong\u003e As the sample flows through the column, components interact with the stationary phase and are separated based on their differing affinities.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDetection:\u003c\/strong\u003e Separated components are detected, and a chromatogram is generated.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHPLC LI-6300 Model\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe LI-6300 is an advanced HPLC system designed for high precision and efficiency. Here are some of its key features:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh-Pressure Capability:\u003c\/strong\u003e The LI-6300 can operate at high pressures, allowing for the use of smaller particle size columns for better separation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePrecise Flow Control:\u003c\/strong\u003e Advanced pump systems ensure consistent and accurate flow rates.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eAutomated Sample Injection:\u003c\/strong\u003e The system can be equipped with an auto-sampler for high-throughput analysis.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMultiple Detectors:\u003c\/strong\u003e Compatible with various detectors (e.g., UV, PDA, fluorescence) for diverse analytical needs.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Control:\u003c\/strong\u003e Column ovens and thermostats maintain optimal conditions for reproducible results.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eData Management:\u003c\/strong\u003e Integrated software for data acquisition, processing, and reporting.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe HPLC LI-6300 is used in various fields, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePharmaceuticals:\u003c\/strong\u003e Quality control, drug development, and stability testing.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eFood and Beverage:\u003c\/strong\u003e Analysis of additives, contaminants, and nutritional content.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Testing:\u003c\/strong\u003e Detection of pollutants and contaminants in water, soil, and air.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eChemical Research:\u003c\/strong\u003e Separation and analysis of complex mixtures.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003eAdvantages\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e Superior separation of complex mixtures.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSpeed:\u003c\/strong\u003e Rapid analysis compared to traditional column chromatography.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity:\u003c\/strong\u003e Capable of detecting low concentrations of analytes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eReproducibility:\u003c\/strong\u003e High precision in repeated analyses.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg decoding=\"async\" class=\"alignnone size-medium wp-image-9290 lazyautosizes lazyloaded\" src=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_-231x300.jpeg\" alt=\"6300 specification\" width=\"231\" height=\"300\" data-src=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_-231x300.jpeg\" data-srcset=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_-231x300.jpeg 231w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_.jpeg 435w\" data-sizes=\"auto\" data-eio-rwidth=\"231\" data-eio-rheight=\"300\" sizes=\"231px\" srcset=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_-231x300.jpeg 231w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_.jpeg 435w\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lasany","offers":[{"title":"Default Title","offer_id":50518404301097,"sku":"LI-6300","price":850000.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/LI-6300-HPLC-1.webp?v=1777306943"},{"product_id":"high-performance-liquid-chromatography-advanced-with-rheodyne-injector","title":"High-Performance Liquid Chromatography Advanced with (Rheodyne Injector)","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHigh-Performance Liquid Chromatography (HPLC)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eHPLC is a technique in analytical chemistry used to separate, identify, and quantify each component in a mixture. It relies on pumps to pass a pressurized liquid solvent containing the sample mixture through a column filled with a solid adsorbent material. Each component in the sample interacts slightly differently with the adsorbent material, causing different flow rates for the different components and leading to their separation as they flow out of the column.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eKey Components\u003c\/span\u003e\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSolvent Reservoirs:\u003c\/strong\u003e Hold the mobile phase solvents.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePump:\u003c\/strong\u003e Delivers the mobile phase at a high pressure to the system.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInjector:\u003c\/strong\u003e Introduces the sample into the mobile phase stream.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eColumn:\u003c\/strong\u003e Packed with stationary phase material where separation occurs.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDetector:\u003c\/strong\u003e Identifies and quantifies the components as they elute from the column.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eData System:\u003c\/strong\u003e Collects and analyzes the data.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e\u003cspan\u003eWorking Principle\u003c\/span\u003e\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInjection:\u003c\/strong\u003e The sample mixture is injected into the mobile phase stream.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSeparation:\u003c\/strong\u003e As the sample flows through the column, components interact with the stationary phase and are separated based on their differing affinities.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDetection:\u003c\/strong\u003e Separated components are detected, and a chromatogram is generated.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHPLC LI-6310 Model\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe LI-6310 is an advanced HPLC system designed for high precision and efficiency. Here are some of its key features:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh-Pressure Capability:\u003c\/strong\u003e The LI-6310 can operate at high pressures, allowing for the use of smaller particle size columns for better separation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePrecise Flow Control:\u003c\/strong\u003e Advanced pump systems ensure consistent and accurate flow rates.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eAutomated Sample Injection:\u003c\/strong\u003e The system can be equipped with an auto-sampler for high-throughput analysis.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMultiple Detectors:\u003c\/strong\u003e Compatible with various detectors (e.g., UV, PDA, fluorescence) for diverse analytical needs.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Control:\u003c\/strong\u003e Column ovens and thermostats maintain optimal conditions for reproducible results.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eData Management:\u003c\/strong\u003e Integrated software for data acquisition, processing, and reporting.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe HPLC LI-6310 is used in various fields, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePharmaceuticals:\u003c\/strong\u003e Quality control, drug development, and stability testing.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eFood and Beverage:\u003c\/strong\u003e Analysis of additives, contaminants, and nutritional content.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Testing:\u003c\/strong\u003e Detection of pollutants and contaminants in water, soil, and air.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eChemical Research:\u003c\/strong\u003e Separation and analysis of complex mixtures.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003eAdvantages\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e Superior separation of complex mixtures.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSpeed:\u003c\/strong\u003e Rapid analysis compared to traditional column chromatography.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity:\u003c\/strong\u003e Capable of detecting low concentrations of analytes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eReproducibility:\u003c\/strong\u003e High precision in repeated analyses.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg decoding=\"async\" class=\"alignnone size-medium wp-image-9290 lazyautosizes ls-is-cached lazyloaded\" src=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_-231x300.jpeg\" alt=\"6300 specification\" width=\"231\" height=\"300\" data-src=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_-231x300.jpeg\" data-srcset=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_-231x300.jpeg 231w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_.jpeg 435w\" data-sizes=\"auto\" data-eio-rwidth=\"231\" data-eio-rheight=\"300\" sizes=\"231px\" srcset=\"https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_-231x300.jpeg 231w, https:\/\/lasany.org\/wp-content\/uploads\/2023\/07\/Web-capture_24-7-2023_105717_.jpeg 435w\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Lasany","offers":[{"title":"Default Title","offer_id":50518408069417,"sku":"LI-6310","price":1000000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/LI-6300-HPLC-1_33faa0f1-d7d8-4f66-a337-02717cb9ece7.webp?v=1777306933"},{"product_id":"gas-chromatography","title":"Gas chromatography","description":"\u003cp data-section-id=\"1wdow7c\" data-start=\"239\" data-end=\"266\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eThe GC10CI Gas Chromatography system is engineered for high-resolution compound separation and trace-level detection, making it a preferred choice for pharmaceutical labs, environmental testing facilities, and chemical industries. With GLP\/FDA 21 CFR Part 11 compliant software, it ensures data integrity, regulatory compliance, and reliable reporting.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1vgskwa\" data-start=\"268\" data-end=\"287\"\u003eSalient Features\u003c\/h2\u003e\n\u003cul data-start=\"288\" data-end=\"1207\"\u003e\n\u003cli data-section-id=\"1g71si7\" data-start=\"288\" data-end=\"380\"\u003e\n\u003cp data-start=\"290\" data-end=\"380\"\u003e\u003cstrong data-start=\"290\" data-end=\"309\"\u003eControl system:\u003c\/strong\u003e Designed for monitoring and controlling the instrument via computer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xnl3cw\" data-start=\"381\" data-end=\"540\"\u003e\n\u003cp data-start=\"383\" data-end=\"540\"\u003e\u003cstrong data-start=\"383\" data-end=\"411\"\u003eColumn compartment\/oven:\u003c\/strong\u003e Superior thermal performance with multistage (10 ramps) programmed temperature control function (supported by control system).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qhp5re\" data-start=\"541\" data-end=\"685\"\u003e\n\u003cp data-start=\"543\" data-end=\"685\"\u003e\u003cstrong data-start=\"543\" data-end=\"589\"\u003eAdvanced built-in data acquisition system:\u003c\/strong\u003e Supports real-time instrument status monitoring, detection signal acquisition and PC control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18q16un\" data-start=\"686\" data-end=\"819\"\u003e\n\u003cp data-start=\"688\" data-end=\"819\"\u003e\u003cstrong data-start=\"688\" data-end=\"704\"\u003eColumn oven:\u003c\/strong\u003e Accommodates 1 capillary column and supports quick heat-up and rapid cool-down with automated back-door opening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nnuggv\" data-start=\"820\" data-end=\"886\"\u003e\n\u003cp data-start=\"822\" data-end=\"886\"\u003e\u003cstrong data-start=\"822\" data-end=\"853\"\u003eSample introduction system:\u003c\/strong\u003e One sample injector installed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rspe5v\" data-start=\"887\" data-end=\"1018\"\u003e\n\u003cp data-start=\"889\" data-end=\"919\"\u003e\u003cstrong data-start=\"889\" data-end=\"917\"\u003eSample detection system:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"922\" data-end=\"1018\"\u003e\n\u003cli data-section-id=\"ji096q\" data-start=\"922\" data-end=\"1018\"\u003e\n\u003cp data-start=\"924\" data-end=\"1018\"\u003e1 high sensitivity and stability \u003cstrong data-start=\"957\" data-end=\"973\"\u003eFID detector\u003c\/strong\u003e for various organic compound applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16ic2ii\" data-start=\"1019\" data-end=\"1066\"\u003e\n\u003cp data-start=\"1021\" data-end=\"1066\"\u003e\u003cstrong data-start=\"1021\" data-end=\"1046\"\u003eAnalog signal output:\u003c\/strong\u003e 1 output channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rerrvl\" data-start=\"1067\" data-end=\"1207\"\u003e\n\u003cp data-start=\"1069\" data-end=\"1207\"\u003e\u003cstrong data-start=\"1069\" data-end=\"1096\"\u003eSoftware compatibility:\u003c\/strong\u003e Compatible with \u003cstrong data-start=\"1113\" data-end=\"1141\"\u003eGLP \/ FDA-21 CFR Part 11\u003c\/strong\u003e requirements and regulations (electronic records and signatures).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1209\" data-end=\"1212\"\u003e\n\u003ch3 data-section-id=\"1lrs84y\" data-start=\"1214\" data-end=\"1240\"\u003eFID General Applications\u003c\/h3\u003e\n\u003cul data-start=\"1241\" data-end=\"1626\"\u003e\n\u003cli data-section-id=\"1n4wzqt\" data-start=\"1241\" data-end=\"1307\"\u003e\n\u003cp data-start=\"1243\" data-end=\"1267\"\u003eNitrobenzene compounds\u003c\/p\u003e\n\u003cul data-start=\"1270\" data-end=\"1307\"\u003e\n\u003cli data-section-id=\"1kllvkr\" data-start=\"1270\" data-end=\"1286\"\u003e\n\u003cp data-start=\"1272\" data-end=\"1286\"\u003eNitrobenzene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xpkllz\" data-start=\"1289\" data-end=\"1307\"\u003e\n\u003cp data-start=\"1291\" data-end=\"1307\"\u003eDinitrotoluene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13omysf\" data-start=\"1309\" data-end=\"1401\"\u003e\n\u003cp data-start=\"1311\" data-end=\"1336\"\u003eChlorobenzene compounds\u003c\/p\u003e\n\u003cul data-start=\"1339\" data-end=\"1401\"\u003e\n\u003cli data-section-id=\"1bij6v4\" data-start=\"1339\" data-end=\"1356\"\u003e\n\u003cp data-start=\"1341\" data-end=\"1356\"\u003eChlorobenzene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19totd9\" data-start=\"1359\" data-end=\"1378\"\u003e\n\u003cp data-start=\"1361\" data-end=\"1378\"\u003eDichlorobenzene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ayohjj\" data-start=\"1381\" data-end=\"1401\"\u003e\n\u003cp data-start=\"1383\" data-end=\"1401\"\u003eTrichlorobenzene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tlw3z3\" data-start=\"1403\" data-end=\"1526\"\u003e\n\u003cp data-start=\"1405\" data-end=\"1421\"\u003eBenzene series\u003c\/p\u003e\n\u003cul data-start=\"1424\" data-end=\"1526\"\u003e\n\u003cli data-section-id=\"lq6tlw\" data-start=\"1424\" data-end=\"1435\"\u003e\n\u003cp data-start=\"1426\" data-end=\"1435\"\u003eToluene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wo7d5l\" data-start=\"1438\" data-end=\"1454\"\u003e\n\u003cp data-start=\"1440\" data-end=\"1454\"\u003eEthylbenzene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"180v2mh\" data-start=\"1457\" data-end=\"1469\"\u003e\n\u003cp data-start=\"1459\" data-end=\"1469\"\u003eO-Xylene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4k58ej\" data-start=\"1472\" data-end=\"1484\"\u003e\n\u003cp data-start=\"1474\" data-end=\"1484\"\u003eM-Xylene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"bna22e\" data-start=\"1487\" data-end=\"1499\"\u003e\n\u003cp data-start=\"1489\" data-end=\"1499\"\u003eP-Xylene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"149bdd6\" data-start=\"1502\" data-end=\"1513\"\u003e\n\u003cp data-start=\"1504\" data-end=\"1513\"\u003eStyrene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gqm9gd\" data-start=\"1516\" data-end=\"1526\"\u003e\n\u003cp data-start=\"1518\" data-end=\"1526\"\u003eCumene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"glpmdk\" data-start=\"1528\" data-end=\"1575\"\u003e\n\u003cp data-start=\"1530\" data-end=\"1575\"\u003e\u003cstrong data-start=\"1530\" data-end=\"1573\"\u003eTVOC (Total Volatile Organic Compounds)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hjqkok\" data-start=\"1576\" data-end=\"1626\"\u003e\n\u003cp data-start=\"1578\" data-end=\"1600\"\u003e\u003cstrong data-start=\"1578\" data-end=\"1600\"\u003ePhenolic compounds\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1603\" data-end=\"1626\"\u003e\n\u003cli data-section-id=\"1m6eqjc\" data-start=\"1603\" data-end=\"1613\"\u003e\n\u003cp data-start=\"1605\" data-end=\"1613\"\u003ePhenol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xontf0\" data-start=\"1616\" data-end=\"1626\"\u003e\n\u003cp data-start=\"1618\" data-end=\"1626\"\u003eCresol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1628\" data-end=\"1736\"\u003eNote: Depending on test circumstances, \u003cstrong data-start=\"1667\" data-end=\"1719\"\u003eheadspace sampler or thermal analysis instrument\u003c\/strong\u003e may be required.\u003c\/p\u003e\n\u003chr data-start=\"1738\" data-end=\"1741\"\u003e\n\u003ch3 data-section-id=\"8hqlwo\" data-start=\"1743\" data-end=\"1787\"\u003eSoftware: Advanced Computer Control System\u003c\/h3\u003e\n\u003cul data-start=\"1788\" data-end=\"2213\"\u003e\n\u003cli data-section-id=\"sjs0ci\" data-start=\"1788\" data-end=\"1869\"\u003e\n\u003cp data-start=\"1790\" data-end=\"1869\"\u003eSuperior performance with advanced computer-based temperature control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1uiny8h\" data-start=\"1870\" data-end=\"1922\"\u003e\n\u003cp data-start=\"1872\" data-end=\"1922\"\u003eHigh temperature accuracy \u003cstrong data-start=\"1898\" data-end=\"1919\"\u003e(±0.02°C optimum)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ctvhum\" data-start=\"1923\" data-end=\"1978\"\u003e\n\u003cp data-start=\"1925\" data-end=\"1978\"\u003eHigh reliability with anti-interference protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zo1oie\" data-start=\"1979\" data-end=\"2094\"\u003e\n\u003cp data-start=\"1981\" data-end=\"2041\"\u003e\u003cstrong data-start=\"1981\" data-end=\"2029\"\u003eSelf-diagnosis and self-protection functions\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"2044\" data-end=\"2094\"\u003e\n\u003cli data-section-id=\"1ivqwvx\" data-start=\"2044\" data-end=\"2067\"\u003e\n\u003cp data-start=\"2046\" data-end=\"2067\"\u003eOverheat protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t6wn92\" data-start=\"2070\" data-end=\"2094\"\u003e\n\u003cp data-start=\"2072\" data-end=\"2094\"\u003ePower-off protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gtjmjd\" data-start=\"2095\" data-end=\"2213\"\u003e\n\u003cp data-start=\"2097\" data-end=\"2123\"\u003eIntuitive display showing:\u003c\/p\u003e\n\u003cul data-start=\"2126\" data-end=\"2213\"\u003e\n\u003cli data-section-id=\"p586k\" data-start=\"2126\" data-end=\"2144\"\u003e\n\u003cp data-start=\"2128\" data-end=\"2144\"\u003eTiming program\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4zpuva\" data-start=\"2147\" data-end=\"2166\"\u003e\n\u003cp data-start=\"2149\" data-end=\"2166\"\u003eDetector status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"189ryot\" data-start=\"2169\" data-end=\"2190\"\u003e\n\u003cp data-start=\"2171\" data-end=\"2190\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"30gmn8\" data-start=\"2193\" data-end=\"2213\"\u003e\n\u003cp data-start=\"2195\" data-end=\"2213\"\u003eCurrent settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2215\" data-end=\"2320\"\u003e\u003cstrong data-start=\"2215\" data-end=\"2224\"\u003eNote:\u003c\/strong\u003e Computer is not included with the instrument. User must provide a computer to run the software.\u003c\/p\u003e\n\u003chr data-start=\"2322\" data-end=\"2325\"\u003e\n\u003ch3 data-section-id=\"1spgaq0\" data-start=\"2327\" data-end=\"2343\"\u003eSpecifications\u003c\/h3\u003e\n\u003cp data-start=\"2345\" data-end=\"2389\"\u003e\u003cstrong data-start=\"2345\" data-end=\"2355\"\u003eModel:\u003c\/strong\u003e GC10CI\u003cbr data-start=\"2362\" data-end=\"2365\"\u003e\u003cstrong data-start=\"2365\" data-end=\"2378\"\u003eHSN Code:\u003c\/strong\u003e 90272000\u003c\/p\u003e\n\u003ch3 data-section-id=\"16umh3v\" data-start=\"2391\" data-end=\"2415\"\u003eStandard Accessories\u003c\/h3\u003e\n\u003cul data-start=\"2416\" data-end=\"2498\"\u003e\n\u003cli data-section-id=\"1t4gtg4\" data-start=\"2416\" data-end=\"2439\"\u003e\n\u003cp data-start=\"2418\" data-end=\"2439\"\u003eMain instrument set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18cmsjx\" data-start=\"2440\" data-end=\"2454\"\u003e\n\u003cp data-start=\"2442\" data-end=\"2454\"\u003ePower cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1578cq\" data-start=\"2455\" data-end=\"2477\"\u003e\n\u003cp data-start=\"2457\" data-end=\"2477\"\u003eInstruction manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hg2otn\" data-start=\"2478\" data-end=\"2498\"\u003e\n\u003cp data-start=\"2480\" data-end=\"2498\"\u003eTest certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2500\" data-end=\"2503\"\u003e\n\u003ch3 data-section-id=\"8o5s9t\" data-start=\"2505\" data-end=\"2519\"\u003eColumn Oven\u003c\/h3\u003e\n\u003cul data-start=\"2520\" data-end=\"2829\"\u003e\n\u003cli data-section-id=\"cna36t\" data-start=\"2520\" data-end=\"2580\"\u003e\n\u003cp data-start=\"2522\" data-end=\"2580\"\u003e\u003cstrong data-start=\"2522\" data-end=\"2544\"\u003eTemperature Range:\u003c\/strong\u003e RT +7°C to 400°C (1°C increments)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6u3k9p\" data-start=\"2581\" data-end=\"2618\"\u003e\n\u003cp data-start=\"2583\" data-end=\"2618\"\u003e\u003cstrong data-start=\"2583\" data-end=\"2608\"\u003eTemperature Accuracy:\u003c\/strong\u003e ±0.02°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1px1oay\" data-start=\"2619\" data-end=\"2688\"\u003e\n\u003cp data-start=\"2621\" data-end=\"2688\"\u003e\u003cstrong data-start=\"2621\" data-end=\"2638\"\u003eCooling Time:\u003c\/strong\u003e 400°C to 50°C in 8–10 minutes (at 25°C ambient)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"b7305c\" data-start=\"2689\" data-end=\"2760\"\u003e\n\u003cp data-start=\"2691\" data-end=\"2760\"\u003e\u003cstrong data-start=\"2691\" data-end=\"2723\"\u003eProgrammed Temperature Rate:\u003c\/strong\u003e 0.1°C to 40°C\/min (1°C increments)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q4c1us\" data-start=\"2761\" data-end=\"2829\"\u003e\n\u003cp data-start=\"2763\" data-end=\"2829\"\u003e\u003cstrong data-start=\"2763\" data-end=\"2781\"\u003eProgram Ramps:\u003c\/strong\u003e 7 ramps standard (up to 10 ramps with software)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"2831\" data-end=\"2845\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2846\" data-end=\"2950\"\u003e\n\u003cli data-section-id=\"xyrg16\" data-start=\"2846\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2848\" data-end=\"2897\"\u003e\u003cstrong data-start=\"2848\" data-end=\"2876\"\u003eInside Size (L × W × H):\u003c\/strong\u003e 284 × 280 × 241 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2go6ku\" data-start=\"2898\" data-end=\"2950\"\u003e\n\u003cp data-start=\"2900\" data-end=\"2950\"\u003e\u003cstrong data-start=\"2900\" data-end=\"2929\"\u003eOutside Size (L × W × H):\u003c\/strong\u003e 340 × 345 × 281 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2952\" data-end=\"2955\"\u003e\n\u003ch3 data-section-id=\"ilb2ut\" data-start=\"2957\" data-end=\"2974\"\u003eDetector (FID)\u003c\/h3\u003e\n\u003cul data-start=\"2975\" data-end=\"3084\"\u003e\n\u003cli data-section-id=\"ozss9u\" data-start=\"2975\" data-end=\"3015\"\u003e\n\u003cp data-start=\"2977\" data-end=\"3015\"\u003e\u003cstrong data-start=\"2977\" data-end=\"2997\"\u003eDetection Limit:\u003c\/strong\u003e ≤ 3 × 10⁻¹² g\/s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2pmxpp\" data-start=\"3016\" data-end=\"3053\"\u003e\n\u003cp data-start=\"3018\" data-end=\"3053\"\u003e\u003cstrong data-start=\"3018\" data-end=\"3028\"\u003eDrift:\u003c\/strong\u003e ≤ 6 × 10⁻¹³ A \/ 30 min\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16k2fdy\" data-start=\"3054\" data-end=\"3084\"\u003e\n\u003cp data-start=\"3056\" data-end=\"3084\"\u003e\u003cstrong data-start=\"3056\" data-end=\"3076\"\u003eLinearity Range:\u003c\/strong\u003e ≥ 10⁶\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3086\" data-end=\"3089\"\u003e\n\u003ch3 data-section-id=\"4u3vl2\" data-start=\"3091\" data-end=\"3120\"\u003eSample Introduction System\u003c\/h3\u003e\n\u003cul data-start=\"3121\" data-end=\"3143\"\u003e\n\u003cli data-section-id=\"e1w0gr\" data-start=\"3121\" data-end=\"3143\"\u003e\n\u003cp data-start=\"3123\" data-end=\"3143\"\u003eCapillary injector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3145\" data-end=\"3148\"\u003e\n\u003ch3 data-section-id=\"1ptu1li\" data-start=\"3150\" data-end=\"3171\"\u003ePower Requirements\u003c\/h3\u003e\n\u003cul data-start=\"3172\" data-end=\"3229\"\u003e\n\u003cli data-section-id=\"eflijc\" data-start=\"3172\" data-end=\"3193\"\u003e\n\u003cp data-start=\"3174\" data-end=\"3193\"\u003e\u003cstrong data-start=\"3174\" data-end=\"3184\"\u003ePower:\u003c\/strong\u003e 2000 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wppeww\" data-start=\"3194\" data-end=\"3229\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3229\"\u003e\u003cstrong data-start=\"3196\" data-end=\"3213\"\u003ePower Supply:\u003c\/strong\u003e 220 V \/ 50 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3231\" data-end=\"3234\"\u003e\n\u003ch3 data-section-id=\"1fltwr4\" data-start=\"3236\" data-end=\"3258\"\u003ePacking Information\u003c\/h3\u003e\n\u003cul data-start=\"3259\" data-end=\"3337\"\u003e\n\u003cli data-section-id=\"uqh0z7\" data-start=\"3259\" data-end=\"3299\"\u003e\n\u003cp data-start=\"3261\" data-end=\"3299\"\u003e\u003cstrong data-start=\"3261\" data-end=\"3278\"\u003ePacking Size:\u003c\/strong\u003e 830 × 680 × 855 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kt2hlt\" data-start=\"3300\" data-end=\"3337\"\u003e\n\u003cp data-start=\"3302\" data-end=\"3337\"\u003e\u003cstrong data-start=\"3302\" data-end=\"3329\"\u003eGross Weight (Approx.):\u003c\/strong\u003e 79 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3339\" data-end=\"3342\"\u003e\n\u003ch3 data-section-id=\"uoahhp\" data-start=\"3344\" data-end=\"3367\"\u003eOptional Accessories\u003c\/h3\u003e\n\u003cul data-start=\"3368\" data-end=\"3440\"\u003e\n\u003cli data-section-id=\"x00mvz\" data-start=\"3368\" data-end=\"3396\"\u003e\n\u003cp data-start=\"3370\" data-end=\"3396\"\u003e\u003cstrong data-start=\"3370\" data-end=\"3387\"\u003eAuto Sampler:\u003c\/strong\u003e ASGC22\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xicf9r\" data-start=\"3397\" data-end=\"3440\"\u003e\n\u003cp data-start=\"3399\" data-end=\"3440\"\u003e\u003cstrong data-start=\"3399\" data-end=\"3440\"\u003eAir source \/ flow rate control device\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52797919985961,"sku":"GC10CI","price":489000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/GC10CI.jpg?v=1777055111"},{"product_id":"gas-chromatography-1","title":"Gas chromatography I Advanced GC System with EPC \u0026 FID Detector I GLP\/FDA\/CFR Part 11 Complaint","description":"\u003cp data-end=\"501\" data-start=\"75\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"108\" data-start=\"79\"\u003eGas Chromatography GC99SI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eavailable at\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eLabmart.in\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analytical instrument designed for precise separation and analysis of volatile organic compounds (VOCs). Built with advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"345\" data-start=\"307\"\u003eElectronic Pneumatic Control (EPC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"404\" data-start=\"352\"\u003ehigh-sensitivity Flame Ionization Detector (FID)\u003c\/strong\u003e, this system is ideal for laboratories requiring accuracy, compliance, and reliable performance.\u003c\/p\u003e\n\u003ch2 data-end=\"367\" data-start=\"349\" data-section-id=\"iy0zl5\"\u003eSALIENT FEATURES\u003c\/h2\u003e\n\u003cul data-end=\"1186\" data-start=\"368\"\u003e\n\u003cli data-end=\"413\" data-start=\"368\" data-section-id=\"1l7yvpt\"\u003e\n\u003cp data-end=\"413\" data-start=\"370\"\u003eEPC – Electronic Pneumatic Control system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"445\" data-start=\"414\" data-section-id=\"puu1k0\"\u003e\n\u003cp data-end=\"445\" data-start=\"416\"\u003e7 inch touch screen display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"536\" data-start=\"446\" data-section-id=\"15tkyce\"\u003e\n\u003cp data-end=\"536\" data-start=\"448\"\u003eControl system designed for monitoring and controlling the instrument through computer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"642\" data-start=\"537\" data-section-id=\"dkcyz2\"\u003e\n\u003cp data-end=\"582\" data-start=\"539\"\u003eMultistage programmed temperature control\u003c\/p\u003e\n\u003cul data-end=\"642\" data-start=\"585\"\u003e\n\u003cli data-end=\"613\" data-start=\"585\" data-section-id=\"w48kqo\"\u003e\n\u003cp data-end=\"613\" data-start=\"587\"\u003e20 ramps with instrument\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"642\" data-start=\"616\" data-section-id=\"1xbgqmw\"\u003e\n\u003cp data-end=\"642\" data-start=\"618\"\u003e99 ramps with software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"776\" data-start=\"643\" data-section-id=\"djguxl\"\u003e\n\u003cp data-end=\"776\" data-start=\"645\"\u003eAdvanced built-in data acquisition system supporting real-time instrument monitoring, detection signal acquisition and PC control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"875\" data-start=\"777\" data-section-id=\"f0ay70\"\u003e\n\u003cp data-end=\"875\" data-start=\"779\"\u003eColumn oven supports quick heat-up and rapid cool-down with automated inside back-door opening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"935\" data-start=\"876\" data-section-id=\"1f3qx2c\"\u003e\n\u003cp data-end=\"935\" data-start=\"878\"\u003eSample introduction system: 1 sample injector installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1054\" data-start=\"936\" data-section-id=\"fjojmz\"\u003e\n\u003cp data-end=\"1054\" data-start=\"938\"\u003eSample detection system: High sensitivity and stability \u003cstrong data-end=\"1010\" data-start=\"994\"\u003eFID detector\u003c\/strong\u003e for various organic compound applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1083\" data-start=\"1055\" data-section-id=\"1jbqbk7\"\u003e\n\u003cp data-end=\"1083\" data-start=\"1057\"\u003eOne analog signal output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1186\" data-start=\"1084\" data-section-id=\"yyh1p3\"\u003e\n\u003cp data-end=\"1186\" data-start=\"1086\"\u003eSoftware compatible with \u003cstrong data-end=\"1137\" data-start=\"1111\"\u003eGLP\/FDA-21 CFR Part 11\u003c\/strong\u003e requirements (electronic records and signatures)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1191\" data-start=\"1188\"\u003e\n\u003ch1 data-end=\"1220\" data-start=\"1193\" data-section-id=\"1wduzrt\"\u003eGas Chromatography GC99SI\u003c\/h1\u003e\n\u003cp data-end=\"1289\" data-start=\"1221\"\u003eMicroprocessor technology with EPC system and touchscreen interface.\u003c\/p\u003e\n\u003cp data-end=\"1300\" data-start=\"1291\"\u003eIncludes:\u003c\/p\u003e\n\u003cul data-end=\"1362\" data-start=\"1301\"\u003e\n\u003cli data-end=\"1327\" data-start=\"1301\" data-section-id=\"6aqgph\"\u003e\n\u003cp data-end=\"1327\" data-start=\"1303\"\u003eCapillary column inlet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1344\" data-start=\"1328\" data-section-id=\"1odkyft\"\u003e\n\u003cp data-end=\"1344\" data-start=\"1330\"\u003eFID detector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1362\" data-start=\"1345\" data-section-id=\"171po2q\"\u003e\n\u003cp data-end=\"1362\" data-start=\"1347\"\u003eSoftware system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1374\" data-start=\"1364\"\u003eFunctions:\u003c\/p\u003e\n\u003cul data-end=\"1755\" data-start=\"1375\"\u003e\n\u003cli data-end=\"1423\" data-start=\"1375\" data-section-id=\"or8wtx\"\u003e\n\u003cp data-end=\"1423\" data-start=\"1377\"\u003eInstrument monitoring and control through PC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1510\" data-start=\"1424\" data-section-id=\"j4neaj\"\u003e\n\u003cp data-end=\"1510\" data-start=\"1426\"\u003eColumn oven with superior thermal performance and programmable temperature control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1601\" data-start=\"1511\" data-section-id=\"10dyclw\"\u003e\n\u003cp data-end=\"1601\" data-start=\"1513\"\u003eBuilt-in data acquisition system for instrument status monitoring and signal detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1671\" data-start=\"1602\" data-section-id=\"199e8ro\"\u003e\n\u003cp data-end=\"1671\" data-start=\"1604\"\u003eQuick heat-up and cool-down oven with automated back-door opening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1702\" data-start=\"1672\" data-section-id=\"4uj0do\"\u003e\n\u003cp data-end=\"1702\" data-start=\"1674\"\u003eDual analog output signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1755\" data-start=\"1703\" data-section-id=\"104r2p5\"\u003e\n\u003cp data-end=\"1755\" data-start=\"1705\"\u003ePC software compatible with GLP\/FDA-21 CFR Part 11\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1760\" data-start=\"1757\"\u003e\n\u003ch1 data-end=\"1799\" data-start=\"1762\" data-section-id=\"1sw4p2y\"\u003eElectronic Pneumatic Control System\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2023\" data-start=\"1801\"\u003e\n\u003cthead data-end=\"1822\" data-start=\"1801\"\u003e\n\u003ctr data-end=\"1822\" data-start=\"1801\"\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"1813\" data-start=\"1801\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"1822\" data-start=\"1813\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2023\" data-start=\"1833\"\u003e\n\u003ctr data-end=\"1882\" data-start=\"1833\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1845\" data-start=\"1833\"\u003eFlow rate\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1882\" data-start=\"1845\"\u003e200 ml\/min (N₂), 1000 ml\/min (He)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1911\" data-start=\"1883\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1904\" data-start=\"1883\"\u003eFlow rate accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1911\" data-start=\"1904\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1948\" data-start=\"1912\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1938\" data-start=\"1912\"\u003eFlow rate repeatability\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1948\" data-start=\"1938\"\u003e±0.35%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1991\" data-start=\"1949\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1963\" data-start=\"1949\"\u003eSplit ratio\u003c\/td\u003e\n\u003ctd data-end=\"1991\" data-start=\"1963\" data-col-size=\"sm\"\u003e0–5000 (He), 0–1000 (N₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2023\" data-start=\"1992\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2012\" data-start=\"1992\"\u003eInlet temperature\u003c\/td\u003e\n\u003ctd data-end=\"2023\" data-start=\"2012\" data-col-size=\"sm\"\u003e0–420°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2028\" data-start=\"2025\"\u003e\n\u003ch1 data-end=\"2060\" data-start=\"2030\" data-section-id=\"g5ib4n\"\u003eApplications of FID Detector\u003c\/h1\u003e\n\u003cp data-end=\"2082\" data-start=\"2061\"\u003eUsed for analysis of:\u003c\/p\u003e\n\u003cul data-end=\"2384\" data-start=\"2084\"\u003e\n\u003cli data-end=\"2139\" data-start=\"2084\" data-section-id=\"560b08\"\u003e\n\u003cp data-end=\"2139\" data-start=\"2086\"\u003eNitrobenzene compounds (nitrobenzene, dinitrotoluene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2216\" data-start=\"2140\" data-section-id=\"14os5i1\"\u003e\n\u003cp data-end=\"2216\" data-start=\"2142\"\u003eChlorobenzene compounds (chlorobenzene, dichlorobenzene, trichlorobenzene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2304\" data-start=\"2217\" data-section-id=\"1m9mj15\"\u003e\n\u003cp data-end=\"2304\" data-start=\"2219\"\u003eBenzene series (toluene, ethylbenzene, o-xylene, m-xylene, p-xylene, styrene, cumene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2346\" data-start=\"2305\" data-section-id=\"p48xvs\"\u003e\n\u003cp data-end=\"2346\" data-start=\"2307\"\u003eTVOC (Total Volatile Organic Compounds)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2384\" data-start=\"2347\" data-section-id=\"1fwxk1l\"\u003e\n\u003cp data-end=\"2384\" data-start=\"2349\"\u003ePhenolic compounds (phenol, cresol)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2450\" data-start=\"2386\"\u003eAdditional accessories may be required depending on application:\u003c\/p\u003e\n\u003cul data-end=\"2500\" data-start=\"2451\"\u003e\n\u003cli data-end=\"2470\" data-start=\"2451\" data-section-id=\"b0pdv4\"\u003e\n\u003cp data-end=\"2470\" data-start=\"2453\"\u003eHeadspace sampler\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2500\" data-start=\"2471\" data-section-id=\"lc2t5w\"\u003e\n\u003cp data-end=\"2500\" data-start=\"2473\"\u003eThermal analysis instrument\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2505\" data-start=\"2502\"\u003e\n\u003ch1 data-end=\"2546\" data-start=\"2507\" data-section-id=\"rynrwn\"\u003eAdvanced Microcomputer Control System\u003c\/h1\u003e\n\u003cp data-end=\"2557\" data-start=\"2548\"\u003eFeatures:\u003c\/p\u003e\n\u003cul data-end=\"2908\" data-start=\"2558\"\u003e\n\u003cli data-end=\"2612\" data-start=\"2558\" data-section-id=\"1x9omn7\"\u003e\n\u003cp data-end=\"2612\" data-start=\"2560\"\u003eAdvanced computer-based temperature control system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2652\" data-start=\"2613\" data-section-id=\"2v3n8o\"\u003e\n\u003cp data-end=\"2652\" data-start=\"2615\"\u003eHigh temperature accuracy (±0.02°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2702\" data-start=\"2653\" data-section-id=\"771r6w\"\u003e\n\u003cp data-end=\"2702\" data-start=\"2655\"\u003eHigh reliability and anti-interference design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2804\" data-start=\"2703\" data-section-id=\"jw5p3t\"\u003e\n\u003cp data-end=\"2751\" data-start=\"2705\"\u003eSelf-diagnosis and self-protection functions\u003c\/p\u003e\n\u003cul data-end=\"2804\" data-start=\"2754\"\u003e\n\u003cli data-end=\"2777\" data-start=\"2754\" data-section-id=\"1ivqwvx\"\u003e\n\u003cp data-end=\"2777\" data-start=\"2756\"\u003eOverheat protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2804\" data-start=\"2780\" data-section-id=\"1t6wn92\"\u003e\n\u003cp data-end=\"2804\" data-start=\"2782\"\u003ePower-off protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2908\" data-start=\"2805\" data-section-id=\"1rdwa2a\"\u003e\n\u003cp data-end=\"2818\" data-start=\"2807\"\u003eDisplay of:\u003c\/p\u003e\n\u003cul data-end=\"2908\" data-start=\"2821\"\u003e\n\u003cli data-end=\"2839\" data-start=\"2821\" data-section-id=\"p586k\"\u003e\n\u003cp data-end=\"2839\" data-start=\"2823\"\u003eTiming program\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2861\" data-start=\"2842\" data-section-id=\"4zpuva\"\u003e\n\u003cp data-end=\"2861\" data-start=\"2844\"\u003eDetector status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2885\" data-start=\"2864\" data-section-id=\"189ryot\"\u003e\n\u003cp data-end=\"2885\" data-start=\"2866\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2908\" data-start=\"2888\" data-section-id=\"30gmn8\"\u003e\n\u003cp data-end=\"2908\" data-start=\"2890\"\u003eCurrent settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2962\" data-start=\"2910\"\u003eNote: \u003cstrong data-end=\"2962\" data-start=\"2916\"\u003eComputer not included with the instrument.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"2962\" data-start=\"2910\"\u003e\u003cstrong data-end=\"2962\" data-start=\"2916\"\u003eSPECIFICATIONS.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGC99SI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake\u003c\/td\u003e\n\u003ctd\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSN Code\u003c\/td\u003e\n\u003ctd\u003e90272000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003eEPC (Electronic Pneumatic Control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Introduction\u003c\/td\u003e\n\u003ctd\u003eSplit \/ Splitless Injector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetector – FID\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Limit\u003c\/td\u003e\n\u003ctd\u003e≤ 8 × 10⁻¹² g\/s (n-hexadecane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5 × 10⁻¹³ A\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise\u003c\/td\u003e\n\u003ctd\u003e≤ 3 × 10⁻¹⁴ A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Range\u003c\/td\u003e\n\u003ctd\u003e≥ 10⁶\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Temperature\u003c\/td\u003e\n\u003ctd\u003e400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e≥ 10000 mV·ml\/mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Noise\u003c\/td\u003e\n\u003ctd\u003e≤ 20 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Drift\u003c\/td\u003e\n\u003ctd\u003e≤ 100 µV \/ 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Size\u003c\/td\u003e\n\u003ctd\u003e835 × 770 × 930 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 88 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1 data-end=\"4283\" data-start=\"4261\" data-section-id=\"1ogiurf\"\u003eStandard Accessories\u003c\/h1\u003e\n\u003cul data-end=\"4363\" data-start=\"4285\"\u003e\n\u003cli data-end=\"4304\" data-start=\"4285\" data-section-id=\"1s843km\"\u003e\n\u003cp data-end=\"4304\" data-start=\"4287\"\u003eMain Instrument\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4319\" data-start=\"4305\" data-section-id=\"ouvzcd\"\u003e\n\u003cp data-end=\"4319\" data-start=\"4307\"\u003ePower Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4342\" data-start=\"4320\" data-section-id=\"6icai2\"\u003e\n\u003cp data-end=\"4342\" data-start=\"4322\"\u003eInstruction Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4363\" data-start=\"4343\" data-section-id=\"172qrnv\"\u003e\n\u003cp data-end=\"4363\" data-start=\"4345\"\u003eTest Certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"4368\" data-start=\"4365\"\u003e\n\u003ch3 data-end=\"4392\" data-start=\"4370\" data-section-id=\"yknlu6\"\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"4463\" data-start=\"4394\"\u003e\n\u003cli data-end=\"4421\" data-start=\"4394\" data-section-id=\"1kos1fp\"\u003e\n\u003cp data-end=\"4421\" data-start=\"4396\"\u003eAuto Sampler \u003cstrong data-end=\"4419\" data-start=\"4409\"\u003eASGC22\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4463\" data-start=\"4422\" data-section-id=\"1krnntb\"\u003e\n\u003cp data-end=\"4463\" data-start=\"4424\"\u003eAir source \/ flow rate control device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"4099\" data-start=\"4096\"\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":52797977198889,"sku":"GC99SI","price":829999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/qt_q_55.jpg?v=1777055051"},{"product_id":"hplc1is-liquid-chromatography-system","title":"HPLC1IS Liquid Chromatography System – Isocratic HPLC","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eLabmart HPLC1IS Liquid Chromatography System\u003c\/strong\u003e is a high-resolution, precision analytical instrument designed for the efficient separation, identification and quantification of complex chemical mixtures. Its reliable \u003cstrong\u003eisocratic configuration\u003c\/strong\u003e, dual-plunger solvent delivery and electronic pressure control support accurate flow delivery and stable chromatographic operation.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 dir=\"auto\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 dir=\"auto\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eHPLC1IS Liquid Chromatography System\u003c\/strong\u003e is an \u003cstrong\u003eIsocratic System\u003c\/strong\u003e designed for high-resolution and precision analytical chromatography. According to the supplied 2025–26 catalogue, the system is engineered for efficient \u003cstrong\u003eseparation, identification and quantification of complex chemical mixtures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe HPLC1IS incorporates an \u003cstrong\u003eadvanced dual-plunger solvent delivery design\u003c\/strong\u003e intended to provide accurate flow rates with minimum baseline noise. Its Electronic Pressure Control technology helps suppress flow pulsations, while the specialized floating-plunger design reduces friction wear on high-pressure seals.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system is particularly positioned for \u003cstrong\u003epharmaceutical analysis, quality control and biochemical research\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3 dir=\"auto\"\u003eIsocratic Liquid Chromatography\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe HPLC1IS operates as an \u003cstrong\u003eIsocratic System\u003c\/strong\u003e, providing a defined liquid chromatography platform for analytical applications.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eAdvanced Dual-Plunger Solvent Delivery\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe dual-plunger solvent delivery design is intended to provide accurate flow rates while minimizing baseline noise.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eLow Flow Pulsation\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eElectronic Pressure Control technology helps suppress flow pulsations, contributing to baseline stability during operation.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eExtended Seal Life\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eA specialized floating-plunger design minimizes friction wear and is designed to prolong the service life of high-pressure seals.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eHigh Flow Repeatability\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eA multi-point flow calibration curve supports precision and reproducibility across the operating range.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eFine Flow Adjustment\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system provides a \u003cstrong\u003e0.001 ml\/min flow increment\u003c\/strong\u003e, allowing fine adjustment of the flow setting.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWide Timed Operating Range\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe specified timed range extends from \u003cstrong\u003e1 second to 24 hours\u003c\/strong\u003e, supporting different analytical timing requirements.\u003c\/p\u003e\n\u003ch1 dir=\"auto\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eHPLC1IS Catalogue Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eLiquid Chromatography\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHPLC1IS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eIsocratic System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Increment\u003c\/td\u003e\n\u003ctd\u003e0.001 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCollection Mode\u003c\/td\u003e\n\u003ctd\u003eDrop Counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Range\u003c\/td\u003e\n\u003ctd\u003e1 second to 24 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0–2 AU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Cell Volume\u003c\/td\u003e\n\u003ctd\u003e10 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Drift\u003c\/td\u003e\n\u003ctd\u003e2 × 10⁻⁴ AU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input Requirement\u003c\/td\u003e\n\u003ctd\u003eAC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolvent Delivery\u003c\/td\u003e\n\u003ctd\u003eAdvanced dual-plunger design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Control\u003c\/td\u003e\n\u003ctd\u003eElectronic Pressure Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Calibration\u003c\/td\u003e\n\u003ctd\u003eMulti-point flow calibration curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal Design\u003c\/td\u003e\n\u003ctd\u003eSpecialized floating plunger design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 dir=\"auto\"\u003e5. Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue specifically identifies the HPLC1IS for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ePharmaceutical analysis\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eQuality control\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBiochemical research\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSeparation of complex chemical mixtures\u003c\/li\u003e\n\u003cli\u003eIdentification of chemical components\u003c\/li\u003e\n\u003cli\u003eQuantification of chemical components\u003c\/li\u003e\n\u003cli\u003eLaboratory analytical chromatography\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 dir=\"auto\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eThe HPLC1IS is suitable for laboratories involved in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePharmaceutical analysis\u003c\/li\u003e\n\u003cli\u003ePharmaceutical quality control\u003c\/li\u003e\n\u003cli\u003eChemical analysis\u003c\/li\u003e\n\u003cli\u003eBiochemical research\u003c\/li\u003e\n\u003cli\u003eAnalytical research\u003c\/li\u003e\n\u003cli\u003eLaboratory quality-control workflows\u003c\/li\u003e\n\u003cli\u003eSeparation and quantification of complex chemical mixtures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 dir=\"auto\"\u003e1. What is the HPLC1IS?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eHPLC1IS is an \u003cstrong\u003eIsocratic Liquid Chromatography System\u003c\/strong\u003e designed for high-resolution and precision analytical applications.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e2. What is the primary application of HPLC1IS?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system is designed for the \u003cstrong\u003eseparation, identification and quantification of complex chemical mixtures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e3. Is HPLC1IS an isocratic HPLC system?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. The catalogue specifically identifies the system type as \u003cstrong\u003eIsocratic System\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e4. What is the flow increment of HPLC1IS?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe specified flow increment is \u003cstrong\u003e0.001 ml\/min\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e5. What is the detection range?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue specifies a detection range of \u003cstrong\u003e0–2 AU\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e6. What is the flow cell volume?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe specified flow cell volume is \u003cstrong\u003e10 µl\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e7. What is the timed operating range?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe specified timed range is \u003cstrong\u003e1 second to 24 hours\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e8. What collection mode does HPLC1IS use?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue specifies \u003cstrong\u003eDrop Counting\u003c\/strong\u003e as the collection mode.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e9. What power supply does HPLC1IS require?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue specifies \u003cstrong\u003eAC 220V, 50\/60Hz\u003c\/strong\u003e as the power input requirement and \u003cstrong\u003eAC 220V\u003c\/strong\u003e as the power supply.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e10. How does the system reduce flow pulsation?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe HPLC1IS uses \u003cstrong\u003eElectronic Pressure Control technology\u003c\/strong\u003e to suppress flow pulsations and support baseline stability.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e11. How is high flow repeatability achieved?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system uses a \u003cstrong\u003emulti-point flow calibration curve\u003c\/strong\u003e to support precision and reproducibility across the operating range.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e12. What is the purpose of the floating-plunger design?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe specialized floating-plunger design minimizes friction wear and is intended to extend the life of high-pressure seals.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":54228746109225,"sku":"HPLC1IS","price":888799.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/HPLC1IS_Actual_Key_Features.png?v=1790399311"},{"product_id":"asgc22-gas-chromatography-autosampler","title":"ASGC22 Gas Chromatography Autosampler – Automatic GC Sample Injector","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eLabmart ASGC22 Autosampler for Gas Chromatography\u003c\/strong\u003e is an automated sample injection system designed to improve the efficiency, precision and reproducibility of GC analysis. It features a \u003cstrong\u003e5-inch interactive touch interface, 22-position sample tray, programmable injection parameters, multiple injection modes and GC software control\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 dir=\"auto\"\u003e3. Detailed Product Description\u003c\/h1\u003e\n\u003ch2 dir=\"auto\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eASGC22 Autosampler for Gas Chromatography\u003c\/strong\u003e is designed to automatically inject samples into a gas chromatography instrument, reducing manual intervention and supporting consistent sample handling.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue describes the ASGC22 as a compact, lightweight and highly universal autosampler with a \u003cstrong\u003e5-inch visual man-machine interactive touch interface\u003c\/strong\u003e. Its powered injection mechanism is designed to provide stable injection speed and accurate injection volume.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system supports \u003cstrong\u003e22 sample positions, 19 sample vials, 2 solvent vials and 1 waste vial\u003c\/strong\u003e. It allows programmable sample injection times, multiple analytical methods and adjustable needle and sample extraction\/injection speeds.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe ASGC22 also supports \u003cstrong\u003ebarcode scanning, sample temperature control, multiple I\/O connection modes and PC\/GC software control\u003c\/strong\u003e, making it suitable for automated GC workflows.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e5-inch visual man-machine interactive touch interface\u003c\/li\u003e\n\u003cli\u003e22-digit sample tray\u003c\/li\u003e\n\u003cli\u003e19 sample vial positions\u003c\/li\u003e\n\u003cli\u003e2 solvent vial positions\u003c\/li\u003e\n\u003cli\u003e1 waste vial position\u003c\/li\u003e\n\u003cli\u003eInjector sizes from \u003cstrong\u003e1 to 500 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSample injection times programmable from \u003cstrong\u003e1 to 99 times\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eUp to \u003cstrong\u003e20 methods\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum interval of \u003cstrong\u003e999 minutes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMinimum sample size of \u003cstrong\u003e0.1 µl\u003c\/strong\u003e using a 1 µl syringe\u003c\/li\u003e\n\u003cli\u003eMaximum sample size of \u003cstrong\u003e250 µl\u003c\/strong\u003e using a 500 µl syringe\u003c\/li\u003e\n\u003cli\u003eFast, slow and user-defined needle speed\u003c\/li\u003e\n\u003cli\u003eFast, slow and user-defined sample extraction\/injection speed\u003c\/li\u003e\n\u003cli\u003eNormal and continuous injection modes\u003c\/li\u003e\n\u003cli\u003eGC software control\u003c\/li\u003e\n\u003cli\u003eBarcode scanning support\u003c\/li\u003e\n\u003cli\u003eSample temperature control function\u003c\/li\u003e\n\u003cli\u003eMultiple I\/O port modes for connection with different kinds of GC\u003c\/li\u003e\n\u003cli\u003ePC control capability\u003c\/li\u003e\n\u003cli\u003eIntelligent step-by-step order entry with prompts\u003c\/li\u003e\n\u003cli\u003eSynchronous sampling time reproducibility of less than \u003cstrong\u003e1\/1000 s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e24-hour uninterrupted automated operation capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue specifically highlights increased productivity through automated sample injection and improved accuracy through precise and consistent injection volumes. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 dir=\"auto\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eASGC22 Catalogue Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eAutosampler for Gas Chromatography\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASGC22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake in Catalogue\u003c\/td\u003e\n\u003ctd\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSN Code\u003c\/td\u003e\n\u003ctd\u003e90272000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjector Size\u003c\/td\u003e\n\u003ctd\u003e1, 5, 10, 25, 50, 100, 250, 500 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Tray\u003c\/td\u003e\n\u003ctd\u003e22-digit sample tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Vial Capacity\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolvent Vial Capacity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaste Vial Capacity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Injection Times of Each Line\u003c\/td\u003e\n\u003ctd\u003e1 to 99 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Interval\u003c\/td\u003e\n\u003ctd\u003e999 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Sample Size\u003c\/td\u003e\n\u003ctd\u003e0.1 µl using 1 µl syringe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Sample Size\u003c\/td\u003e\n\u003ctd\u003e250 µl using 500 µl syringe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e1 to 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Injection Inlet\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Needle Cleaning Times\u003c\/td\u003e\n\u003ctd\u003e99 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Sample Pumping Times\u003c\/td\u003e\n\u003ctd\u003e99 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Sample Pumping Interval\u003c\/td\u003e\n\u003ctd\u003e5000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViscosity Delay\u003c\/td\u003e\n\u003ctd\u003e0–60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDwell Time Before \u0026amp; After Injection\u003c\/td\u003e\n\u003ctd\u003e0–120 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle Speed\u003c\/td\u003e\n\u003ctd\u003eFast, Slow, User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Extraction \u0026amp; Injection Speed\u003c\/td\u003e\n\u003ctd\u003eFast, Slow, User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Mode\u003c\/td\u003e\n\u003ctd\u003eNormal Mode, Continuity Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Mode\u003c\/td\u003e\n\u003ctd\u003eGC Software Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Dimension (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e620 × 325 × 280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd\u003eMain Instrument, Power Cord, Instruction Manual, Test Certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eThese specifications are taken from the ASGC22 specification table in the supplied 2025–26 catalogue. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 dir=\"auto\"\u003e5. Applications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated sample injection for gas chromatography\u003c\/li\u003e\n\u003cli\u003ePharmaceutical GC analysis\u003c\/li\u003e\n\u003cli\u003eChemical analysis\u003c\/li\u003e\n\u003cli\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli\u003eResearch laboratories\u003c\/li\u003e\n\u003cli\u003eRoutine GC sample processing\u003c\/li\u003e\n\u003cli\u003eAutomated analysis of multiple samples\u003c\/li\u003e\n\u003cli\u003eApplications requiring consistent injection volumes\u003c\/li\u003e\n\u003cli\u003eApplications requiring unattended GC operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 dir=\"auto\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eGas chromatography laboratories\u003c\/li\u003e\n\u003cli\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli\u003eChemical testing laboratories\u003c\/li\u003e\n\u003cli\u003eQuality-control laboratories\u003c\/li\u003e\n\u003cli\u003eResearch and development laboratories\u003c\/li\u003e\n\u003cli\u003eAnalytical testing laboratories\u003c\/li\u003e\n\u003cli\u003eLaboratories performing repetitive GC sample analysis\u003c\/li\u003e\n\u003cli\u003eLaboratories seeking automated sample injection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 dir=\"auto\"\u003e1. What is the ASGC22?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eASGC22 is an \u003cstrong\u003eAutosampler for Gas Chromatography\u003c\/strong\u003e designed to automatically inject samples into a GC instrument.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e2. How many samples can the sample tray hold?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe ASGC22 has a \u003cstrong\u003e22-digit sample tray\u003c\/strong\u003e and supports \u003cstrong\u003e19 sample vials\u003c\/strong\u003e according to the catalogue.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e3. How many solvent vials are supported?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system supports \u003cstrong\u003e2 solvent vials\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e4. Is there a waste vial position?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. The specification table provides \u003cstrong\u003e1 waste vial\u003c\/strong\u003e position.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e5. What injector sizes are available?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue specifies injector sizes of \u003cstrong\u003e1, 5, 10, 25, 50, 100, 250 and 500 µl\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e6. What is the minimum sample size?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe minimum specified sample size is \u003cstrong\u003e0.1 µl when using a 1 µl syringe\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e7. What is the maximum sample size?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe maximum specified sample size is \u003cstrong\u003e250 µl when using a 500 µl syringe\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e8. How many methods can be programmed?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe ASGC22 supports \u003cstrong\u003e1 to 20 methods\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e9. Can the injection speed be adjusted?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. Needle speed and sample extraction\/injection speed can each be set to \u003cstrong\u003eFast, Slow or User-defined\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e10. Does the ASGC22 support continuous injection?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. The catalogue specifies \u003cstrong\u003eNormal Mode and Continuity Mode\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e11. Can the autosampler be controlled through GC software?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. The specified control mode is \u003cstrong\u003eGC Software Control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e12. Does it support barcode scanning?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eYes. The catalogue specifically lists \u003cstrong\u003ebarcode scanning support\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e13. Can the system operate without continuous operator intervention?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe catalogue describes a high degree of automation and states that the system can support \u003cstrong\u003e24 hours of uninterrupted work without a person\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e14. What is the power requirement?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe specified power supply is \u003cstrong\u003eAC 220V \/ 50–60Hz\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":67542029369641,"sku":"ASGC22","price":472699.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/ChatGPTImageSep26_2026_12_59_09PM_1.png?v=1790407767"},{"product_id":"afc100-automatic-fraction-collector","title":"AFC100 Automatic Fraction Collector – 100-Tube Chromatography Fraction Collector","description":"\u003cp dir=\"auto\" data-start=\"138\" data-end=\"497\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"142\" data-end=\"189\"\u003eLabmart AFC100 Automatic Fraction Collector\u003c\/strong\u003e is a microcontroller-based laboratory instrument designed to automate liquid-phase fraction collection during chromatographic analysis. It uses a reliable round-turntable carousel to collect separated fractions into individual vessels, reducing manual handling and supporting efficient laboratory workflows.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p927wt\" dir=\"auto\" data-start=\"534\" data-end=\"553\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp dir=\"auto\" data-start=\"555\" data-end=\"834\"\u003eThe \u003cstrong data-start=\"559\" data-end=\"598\"\u003eAFC100 Automatic Fraction Collector\u003c\/strong\u003e is designed to streamline sample collection during chromatographic analysis. It automates the collection of liquid-phase components into individual collection vessels, helping reduce manual handling and the risk of cross-contamination.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"836\" data-end=\"998\"\u003eThe system features a \u003cstrong data-start=\"858\" data-end=\"886\"\u003eround turntable carousel\u003c\/strong\u003e with capacity for \u003cstrong data-start=\"905\" data-end=\"918\"\u003e100 tubes\u003c\/strong\u003e, making it suitable for sequential fraction collection in laboratory workflows.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1000\" data-end=\"1170\"\u003eThe AFC100 is described in the supplied catalogue as an advanced, microcontroller-based system particularly suitable for applications including \u003cstrong data-start=\"1144\" data-end=\"1169\"\u003ebiochemistry research\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"5m7ztm\" dir=\"auto\" data-start=\"1172\" data-end=\"1200\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3 data-section-id=\"164obq9\" dir=\"auto\" data-start=\"1202\" data-end=\"1233\"\u003ePrecise Fraction Collection\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1235\" data-end=\"1391\"\u003eThe AFC100 is designed for programmable fraction collection based on \u003cstrong data-start=\"1304\" data-end=\"1339\"\u003etime intervals or drop counting\u003c\/strong\u003e, helping provide uniform collection across samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"itsoat\" dir=\"auto\" data-start=\"1393\" data-end=\"1424\"\u003eSmart Microcomputer Control\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1426\" data-end=\"1553\"\u003eAn intuitive \u003cstrong data-start=\"1439\" data-end=\"1466\"\u003edigital LCD\/LED display\u003c\/strong\u003e is managed by a microcomputer control system for stable and straightforward operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1x2dr9k\" dir=\"auto\" data-start=\"1555\" data-end=\"1576\"\u003e100-Tube Capacity\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1578\" data-end=\"1686\"\u003eThe round carousel accommodates \u003cstrong data-start=\"1610\" data-end=\"1634\"\u003e100 collection tubes\u003c\/strong\u003e, supporting extended fraction-collection sequences.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1tsugvg\" dir=\"auto\" data-start=\"1688\" data-end=\"1705\"\u003eDrop Counting\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1707\" data-end=\"1782\"\u003eThe system provides a specified drop-counting range of \u003cstrong data-start=\"1762\" data-end=\"1781\"\u003e1 to 9999 drops\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1x51imd\" dir=\"auto\" data-start=\"1784\" data-end=\"1812\"\u003eExtended Timed Operation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1814\" data-end=\"1950\"\u003eThe specified timed range is \u003cstrong data-start=\"1843\" data-end=\"1867\"\u003e1 second to 24 hours\u003c\/strong\u003e, allowing fraction collection to be configured for different analytical workflows.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ne2ri6\" dir=\"auto\" data-start=\"1952\" data-end=\"1976\"\u003eContinuous Operation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1978\" data-end=\"2144\"\u003eThe catalogue states that the AFC100 can operate continuously for \u003cstrong data-start=\"2044\" data-end=\"2065\"\u003eup to a full week\u003c\/strong\u003e without drop-loss or manual resets, supporting high-throughput laboratory use.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11do8uq\" dir=\"auto\" data-start=\"2146\" data-end=\"2170\"\u003eDurable Construction\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2172\" data-end=\"2241\"\u003eThe unit uses \u003cstrong data-start=\"2186\" data-end=\"2217\"\u003ehigh-durability ABS plastic\u003c\/strong\u003e for its material build.\u003c\/p\u003e\n\u003ch1 data-section-id=\"1jn8ke9\" dir=\"auto\" data-start=\"2243\" data-end=\"2272\"\u003e4. Technical Specifications\u003c\/h1\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2274\" data-end=\"2810\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2274\" data-end=\"2324\"\u003e\n\u003ctr data-start=\"2274\" data-end=\"2324\"\u003e\n\u003cth data-start=\"2274\" data-end=\"2290\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2290\" data-end=\"2324\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eAFC100 Catalogue Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2335\" data-end=\"2810\"\u003e\n\u003ctr data-start=\"2335\" data-end=\"2382\"\u003e\n\u003ctd data-start=\"2335\" data-end=\"2350\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"2350\" data-end=\"2382\" data-col-size=\"sm\"\u003eAutomatic Fraction Collector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2383\" data-end=\"2401\"\u003e\n\u003ctd data-start=\"2383\" data-end=\"2391\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2391\" data-end=\"2401\" data-col-size=\"sm\"\u003eAFC100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2402\" data-end=\"2449\"\u003e\n\u003ctd data-start=\"2402\" data-end=\"2417\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2417\" data-end=\"2449\" data-col-size=\"sm\"\u003eAutomatic Fraction Collector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2450\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2450\" data-end=\"2474\" data-col-size=\"sm\"\u003eMaximum Tube Capacity\u003c\/td\u003e\n\u003ctd data-start=\"2474\" data-end=\"2492\" data-col-size=\"sm\"\u003e12 ml to 15 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2522\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2509\" data-col-size=\"sm\"\u003eTube Quantity\u003c\/td\u003e\n\u003ctd data-start=\"2509\" data-end=\"2522\" data-col-size=\"sm\"\u003e100 Tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2523\" data-end=\"2558\"\u003e\n\u003ctd data-start=\"2523\" data-end=\"2541\" data-col-size=\"sm\"\u003eCollection Mode\u003c\/td\u003e\n\u003ctd data-start=\"2541\" data-end=\"2558\" data-col-size=\"sm\"\u003eDrop Counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2559\" data-end=\"2594\"\u003e\n\u003ctd data-start=\"2559\" data-end=\"2573\" data-col-size=\"sm\"\u003eTimed Range\u003c\/td\u003e\n\u003ctd data-start=\"2573\" data-end=\"2594\" data-col-size=\"sm\"\u003e1 second to 24 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2595\" data-end=\"2641\"\u003e\n\u003ctd data-start=\"2595\" data-end=\"2617\" data-col-size=\"sm\"\u003eDrop Counting Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2617\" data-end=\"2641\"\u003e1 drop to 9999 drops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2642\" data-end=\"2686\"\u003e\n\u003ctd data-start=\"2642\" data-end=\"2657\" data-col-size=\"sm\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd data-start=\"2657\" data-end=\"2686\" data-col-size=\"sm\"\u003eDigital Display (LCD\/LED)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2687\" data-end=\"2735\"\u003e\n\u003ctd data-start=\"2687\" data-end=\"2704\" data-col-size=\"sm\"\u003eMaterial Build\u003c\/td\u003e\n\u003ctd data-start=\"2704\" data-end=\"2735\" data-col-size=\"sm\"\u003eHigh-durability ABS Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2736\" data-end=\"2762\"\u003e\n\u003ctd data-start=\"2736\" data-end=\"2751\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2751\" data-end=\"2762\" data-col-size=\"sm\"\u003eAC 220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2763\" data-end=\"2810\"\u003e\n\u003ctd data-start=\"2763\" data-end=\"2785\" data-col-size=\"sm\"\u003eWorking Environment\u003c\/td\u003e\n\u003ctd data-start=\"2785\" data-end=\"2810\" data-col-size=\"sm\"\u003eTemperature: 4°C–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\" data-start=\"2812\" data-end=\"3067\"\u003eThe catalogue's feature description also states that fraction collection can be automated based on \u003cstrong data-start=\"2911\" data-end=\"2945\"\u003eTime Interval or Drop Counting\u003c\/strong\u003e. The specification table separately lists \u003cstrong data-start=\"2988\" data-end=\"3005\"\u003eDrop Counting\u003c\/strong\u003e under Collection Modes. \u003cspan class=\"contents\" data-content-reference-start=\"3030\" data-content-reference-end=\"3060\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"rimtbo\" dir=\"auto\" data-start=\"3069\" data-end=\"3086\"\u003e5. Applications\u003c\/h1\u003e\n\u003cul data-start=\"3088\" data-end=\"3389\"\u003e\n\u003cli data-section-id=\"hncf6b\" data-start=\"3088\" data-end=\"3125\"\u003eChromatographic fraction collection\u003c\/li\u003e\n\u003cli data-section-id=\"95a5cv\" data-start=\"3126\" data-end=\"3161\"\u003eLiquid-phase component collection\u003c\/li\u003e\n\u003cli data-section-id=\"lu3xbn\" data-start=\"3162\" data-end=\"3185\"\u003eBiochemistry research\u003c\/li\u003e\n\u003cli data-section-id=\"1grt933\" data-start=\"3186\" data-end=\"3223\"\u003eLaboratory chromatography workflows\u003c\/li\u003e\n\u003cli data-section-id=\"17aqkbo\" data-start=\"3224\" data-end=\"3262\"\u003eAutomated sample fraction collection\u003c\/li\u003e\n\u003cli data-section-id=\"ycyz5s\" data-start=\"3263\" data-end=\"3315\"\u003eSequential collection of chromatographic fractions\u003c\/li\u003e\n\u003cli data-section-id=\"1fc6wrf\" data-start=\"3316\" data-end=\"3350\"\u003eResearch laboratory applications\u003c\/li\u003e\n\u003cli data-section-id=\"13dswpu\" data-start=\"3351\" data-end=\"3389\"\u003eHigh-throughput laboratory workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"pugzbo\" dir=\"auto\" data-start=\"3391\" data-end=\"3408\"\u003e6. Suitable For\u003c\/h1\u003e\n\u003cul data-start=\"3410\" data-end=\"3719\"\u003e\n\u003cli data-section-id=\"11tvf9y\" data-start=\"3410\" data-end=\"3446\"\u003eBiochemistry research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1bzru3d\" data-start=\"3447\" data-end=\"3476\"\u003eChromatography laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1f91tmb\" data-start=\"3477\" data-end=\"3515\"\u003ePharmaceutical research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"9f68h1\" data-start=\"3516\" data-end=\"3541\"\u003eAnalytical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ankfg0\" data-start=\"3542\" data-end=\"3574\"\u003eChemical research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1gsj3qb\" data-start=\"3575\" data-end=\"3625\"\u003eAcademic and institutional research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1o6vihb\" data-start=\"3626\" data-end=\"3680\"\u003eLaboratories requiring automated fraction collection\u003c\/li\u003e\n\u003cli data-section-id=\"1s3n0g9\" data-start=\"3681\" data-end=\"3719\"\u003eHigh-throughput analytical workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1fcqefg\" dir=\"auto\" data-start=\"5665\" data-end=\"5675\" class=\"PDq2pG_selectionAnchorContainer\"\u003e7. FAQs\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch3 data-section-id=\"6uirqy\" dir=\"auto\" data-start=\"5677\" data-end=\"5703\"\u003e1. What is the AFC100?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5705\" data-end=\"5849\"\u003eThe AFC100 is an \u003cstrong data-start=\"5722\" data-end=\"5754\"\u003eAutomatic Fraction Collector\u003c\/strong\u003e designed to automate the collection of liquid-phase fractions during chromatographic analysis.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1aexoms\" dir=\"auto\" data-start=\"5851\" data-end=\"5893\"\u003e2. How many tubes can the AFC100 hold?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5895\" data-end=\"5938\"\u003eThe AFC100 has a capacity of \u003cstrong data-start=\"5924\" data-end=\"5937\"\u003e100 tubes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"va8ys\" dir=\"auto\" data-start=\"5940\" data-end=\"5979\"\u003e3. What tube capacity is specified?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5981\" data-end=\"6051\"\u003eThe catalogue specifies a maximum tube capacity of \u003cstrong data-start=\"6032\" data-end=\"6050\"\u003e12 ml to 15 ml\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"x7i2ji\" dir=\"auto\" data-start=\"6053\" data-end=\"6107\"\u003e4. What collection method does the AFC100 support?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6109\" data-end=\"6299\"\u003eThe specification table identifies \u003cstrong data-start=\"6144\" data-end=\"6161\"\u003eDrop Counting\u003c\/strong\u003e as the collection mode. The feature description also states that collection can be automated based on \u003cstrong data-start=\"6264\" data-end=\"6298\"\u003eTime Interval or Drop Counting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1umbr7p\" dir=\"auto\" data-start=\"6301\" data-end=\"6332\"\u003e5. What is the timed range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6334\" data-end=\"6388\"\u003eThe specified timed range is \u003cstrong data-start=\"6363\" data-end=\"6387\"\u003e1 second to 24 hours\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"et43dc\" dir=\"auto\" data-start=\"6390\" data-end=\"6429\"\u003e6. What is the drop-counting range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6431\" data-end=\"6492\"\u003eThe AFC100 has a specified range of \u003cstrong data-start=\"6467\" data-end=\"6491\"\u003e1 drop to 9999 drops\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t0skhc\" dir=\"auto\" data-start=\"6494\" data-end=\"6532\"\u003e7. Does the AFC100 have a display?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6534\" data-end=\"6595\"\u003eYes. The catalogue specifies a \u003cstrong data-start=\"6565\" data-end=\"6594\"\u003eDigital Display (LCD\/LED)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rlyi7o\" dir=\"auto\" data-start=\"6597\" data-end=\"6638\"\u003e8. What type of construction is used?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6640\" data-end=\"6704\"\u003eThe specified material build is \u003cstrong data-start=\"6672\" data-end=\"6703\"\u003ehigh-durability ABS plastic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"oe65ec\" dir=\"auto\" data-start=\"6706\" data-end=\"6755\"\u003e9. What power supply does the AFC100 require?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6757\" data-end=\"6793\"\u003eThe catalogue specifies \u003cstrong data-start=\"6781\" data-end=\"6792\"\u003eAC 220V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1prmm99\" dir=\"auto\" data-start=\"6795\" data-end=\"6841\"\u003e10. What is the working temperature range?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6843\" data-end=\"6908\"\u003eThe specified working environment temperature is \u003cstrong data-start=\"6892\" data-end=\"6907\"\u003e4°C to 40°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"dz3kc9\" dir=\"auto\" data-start=\"6910\" data-end=\"6970\"\u003e11. Can the AFC100 be used for chromatographic analysis?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"6972\" data-end=\"7069\"\u003eYes. It is specifically designed to automate fraction collection during chromatographic analysis.\u003c\/p\u003e\n\u003ch3 data-section-id=\"nf8dfp\" dir=\"auto\" data-start=\"7071\" data-end=\"7107\"\u003e12. Can it operate continuously?\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"7109\" data-end=\"7243\"\u003eThe catalogue states that the AFC100 is designed for continuous operation of \u003cstrong data-start=\"7186\" data-end=\"7242\"\u003eup to a full week without drop-loss or manual resets\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":67542054732073,"sku":"AFC100","price":156199.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/files\/AFC100_Clean_White_Background.png?v=1790408574"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/1740\/6249\/collections\/lasany-international-panchkula-panchkula-spectrophotometer-dealers-e3xukge8i5.jpg?v=1771333011","url":"https:\/\/www.labmart.in\/collections\/chromatography-instruments.oembed?page=2","provider":"Labmart.in","version":"1.0","type":"link"}